########################################################################################################

2017-05-26 07:39:42: UNIX HEALTH CHECK FOR AIX

Copyright (c) 2004-2017 UNIX Health Check - All Rights Reserved

www.unixhealthcheck.com

This is confidential and unpublished work of authorship subject to limited use license agreements and 
is a trade secret, which is the property of UNIX Health Check (www.unixhealthcheck.com). All use, 
disclosure and/or reproduction not specifically authorized in writing by UNIX Health Check is strictly 
prohibited.

Any expressed or implied warranties are disclaimed. In no event shall UNIX Health Check be liable for 
any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not 
limited to, loss of use, data, profits, or business interruption) however caused and on any theory of 
liability, whether in contract, strict liability, or tort (including negligence or otherwise) arising 
in any way out of the use of these scripts, even if advised of the possibility of such damage.

This report is generated by UNIX Health Check for AIX. It is an overview of check scripts run on an AIX 
system, and depending on the options selected when the checkall.ksh script was run, it will list each 
check script, the returncode of the check script, the output of the check script and a description. At 
the end of this report is an overview of all scripts run and a score report. 

Any individual implementing changes should completely understand the change and deem each change 
appropriate before it is applied to the system. As a standard rule, please take into consideration the 
impact on other components before implementing the change. Also, we encourage all to conduct a peer 
review of all changes before implementation. Most importantly, if the effect of a change is not fully 
understood, do not implement that change until a satisfactory explanation can be given as to what the 
effects of the change are. We recommend implementation of one change at a time. The application of many 
changes all at once will increase the likelihood of confusion, if issues arise.

For more information, check website http://www.unixhealthcheck.com.
For support, email to support@unixhealthcheck.com. 

########################################################################################################

2017-05-26 07:39:42: OPTIONS SELECTED

2017-05-26 07:39:42: Version:         17.05.25
2017-05-26 07:39:42: Start at:        05/26/2017 07:39:41 PDT
2017-05-26 07:39:42: Options:         -C inventory -v -d
2017-05-26 07:39:42: Output file:     checkall_tsm0001.log
2017-05-26 07:39:42: Width:           104
2017-05-26 07:39:42: Display:         All checks
2017-05-26 07:39:42: Descriptions:    Yes
2017-05-26 07:39:42: Category:        inventory
2017-05-26 07:39:42: Output type:     TEXT
2017-05-26 07:39:42: # Checks:        224

########################################################################################################

2017-05-26 07:39:44: SYSTEM CONFIGURATION

2017-05-26 07:39:44: Hostname:        tsm0001 (tsm0001.unixhealthcheck.com)
2017-05-26 07:39:44: IP Address:      192.18.42.43
2017-05-26 07:39:44: IP Assignment:   Static
2017-05-26 07:39:44: Subnet Mask:     255.255.255.0
2017-05-26 07:39:44: Default Gateway: 192.18.42.1
2017-05-26 07:39:44: Name Server(s):  192.18.42.56 192.18.42.57
2017-05-26 07:39:44: LPAR / VM:       1 TSM0001
2017-05-26 07:39:44: OS Level:        AIX 7.1.4.32 7100-04
2017-05-26 07:39:44: PowerHA Level:   7.1.3.6
2017-05-26 07:39:44: Model:           IBM,8286-42A IBM Power S824
2017-05-26 07:39:44: Serial Number:   21C096X
2017-05-26 07:39:44: Firmware Level:  SV860_082
2017-05-26 07:39:44: Kernel:          64 bit
2017-05-26 07:39:44: Hardware:        64 bit
2017-05-26 07:39:44: Processor Type:  PowerPC_POWER8
2017-05-26 07:39:44: CPU Clock Rate:  3525 MHz
2017-05-26 07:39:44: rPerf:           421.90 rPerf  based on 24.00 Virtual CPU cores
2017-05-26 07:39:44: CPUs:            24
2017-05-26 07:39:44: Logical CPUs:    192
2017-05-26 07:39:44: Capacity:        Min: 1.00 Entitled: 24.00 Max: 24.00 Increment: 1.00
2017-05-26 07:39:44: Physical CPUs:   24
2017-05-26 07:39:44: System type:     mode=Capped type=Dedicated-SMT-8 weight=0 smt=8
2017-05-26 07:39:44: Virtual CPUs:    Desired: 24 Min: 1 Online: 24 Max: 24
2017-05-26 07:39:44: Memory:          255744MB
2017-05-26 07:39:44: Memory Settings: min: 256MB, desired: 255744MB, max: 262144MB, online: 255744MB
2017-05-26 07:39:44: Paging Space:    32768MB (1% in use)
2017-05-26 07:39:44: Uptime:          07:39AM up 10 days, 19:39, 1 user, load average: 4.37, 8.09, 7.93

########################################################################################################

2017-05-26 07:39:45: CHECK SCRIPTS

--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:44: Running check script 1 of 224: checkadapters.ksh

Description:
------------

List all the adapters on the system.

This will run the following commands to display the adapter information.

List the available adapters on the system:

# lsdev -Cc adapters.

Display the configuration information for each adapter. For example, for adapter fcs0, the command 
would be:

# lscfg -vl fcs0

Display the detailed attributes for each adapter. For example, for adapter fcs0, the command would be:

# lsattr -El fcs0

Output:
------------

List of adapters: lsdev -Cc adapter

ent0    Available 04-00 PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
ent1    Available 04-01 PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
ent2    Available 04-02 PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
ent3    Available 04-03 PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
ent4    Available 08-00 PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
ent5    Available 08-01 PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
ent6    Available 08-02 PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
ent7    Available 08-03 PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
ent8    Available       EtherChannel / IEEE 802.3ad Link Aggregation
fcs0    Available 00-00 PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
fcs1    Available 00-01 PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
fcs2    Available 0D-00 PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
fcs3    Available 0D-01 PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
pkcs11  Available       ACF/PKCS#11 Device
sissas0 Available 03-00 PCIe3 x8 SAS RAID Internal Adapter 6Gb
sissas1 Available 09-00 PCIe3 x8 SAS RAID Internal Adapter 6Gb
usbhc0  Available 05-00 Integrated USB 3.0 xHCI Adapter (4c1041821410b204)
vsa0    Available       LPAR Virtual Serial Adapter

List of adapters and their physical locations: lsdev -Cc adapter -F "name status physloc"

ent0    Available U78C9.001.WZS0TLH-P1-C6-T1
ent1    Available U78C9.001.WZS0TLH-P1-C6-T2
ent2    Available U78C9.001.WZS0TLH-P1-C6-T3
ent3    Available U78C9.001.WZS0TLH-P1-C6-T4
ent4    Available U78C9.001.WZS0TLH-P1-C10-T1
ent5    Available U78C9.001.WZS0TLH-P1-C10-T2
ent6    Available U78C9.001.WZS0TLH-P1-C10-T3
ent7    Available U78C9.001.WZS0TLH-P1-C10-T4
ent8    Available 
fcs0    Available U78C9.001.WZS0TLH-P1-C7-T1
fcs1    Available U78C9.001.WZS0TLH-P1-C7-T2
fcs2    Available U78C9.001.WZS0TLH-P1-C3-T1
fcs3    Available U78C9.001.WZS0TLH-P1-C3-T2
pkcs11  Available 
sissas0 Available U78C9.001.WZS0TLH-P1-C14-T1
sissas1 Available U78C9.001.WZS0TLH-P1-C15-T1
usbhc0  Available U78C9.001.WZS0TLH-P1
vsa0    Available U8286.42A.21D086X-V1-C0

Configuration information for adapter ent0: lscfg -vl ent0

  ent0             U78C9.001.WZS0TLH-P1-C6-T1  PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94689598
        Network Address.............98BE94689598
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C6-T1

Configuration information for adapter ent1: lscfg -vl ent1

  ent1             U78C9.001.WZS0TLH-P1-C6-T2  PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94689598
        Network Address.............98BE94689599
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C6-T2

Configuration information for adapter ent2: lscfg -vl ent2

  ent2             U78C9.001.WZS0TLH-P1-C6-T3  PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94689598
        Network Address.............98BE9468959A
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C6-T3

Configuration information for adapter ent3: lscfg -vl ent3

  ent3             U78C9.001.WZS0TLH-P1-C6-T4  PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94689598
        Network Address.............98BE9468959B
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C6-T4

Configuration information for adapter ent4: lscfg -vl ent4

  ent4             U78C9.001.WZS0TLH-P1-C10-T1  PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94688C3C
        Network Address.............98BE94688C3C
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C10-T1

Configuration information for adapter ent5: lscfg -vl ent5

  ent5             U78C9.001.WZS0TLH-P1-C10-T2  PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94688C3C
        Network Address.............98BE94688C3D
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C10-T2

Configuration information for adapter ent6: lscfg -vl ent6

  ent6             U78C9.001.WZS0TLH-P1-C10-T3  PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94688C3C
        Network Address.............98BE94688C3E
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C10-T3

Configuration information for adapter ent7: lscfg -vl ent7

  ent7             U78C9.001.WZS0TLH-P1-C10-T4  PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94688C3C
        Network Address.............98BE94688C3F
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C10-T4

Configuration information for adapter ent8: lscfg -vl ent8


Configuration information for adapter fcs0: lscfg -vl fcs0

  fcs0             U78C9.001.WZS0TLH-P1-C7-T1  PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
        Part Number.................00E3495
        EC Level....................D77535
        Customer Card ID Number.....577F
        Manufacturer................001A
        FRU Number..................00E3496
        Device Specific.(ZM)........3
        ROM Level.(alterable).......100300
        Network Address.............10000088ADF49803
        Device Specific.(Z0)........0000000B
        Device Specific.(Z1)........00000030
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........08090000
        Device Specific.(Z4)........01000001
        Device Specific.(Z5)........2E323532
        Device Specific.(Z6)........2E323532
        Device Specific.(Z7)........C0022B40
        Device Specific.(Z8)........20000088ADF49803
        Device Specific.(Z9)........10.2.252.1919
        Device Specific.(ZA)........10.2.252.1919
        Device Specific.(ZB)........00000000
        Device Specific.(ZC)........00040000
        Device Specific.(ZD)........000000FF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C7-T1

Configuration information for adapter fcs1: lscfg -vl fcs1

  fcs1             U78C9.001.WZS0TLH-P1-C7-T2  PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
        Part Number.................00E3495
        EC Level....................D77535
        Customer Card ID Number.....577F
        Manufacturer................001A
        FRU Number..................00E3496
        Device Specific.(ZM)........3
        ROM Level.(alterable).......100300
        Network Address.............10000088ADF49804
        Device Specific.(Z0)........0000000B
        Device Specific.(Z1)........00000030
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........08090000
        Device Specific.(Z4)........01010001
        Device Specific.(Z5)........2E323532
        Device Specific.(Z6)........2E323532
        Device Specific.(Z7)........C0022B40
        Device Specific.(Z8)........20000088ADF49804
        Device Specific.(Z9)........10.2.252.1919
        Device Specific.(ZA)........10.2.252.1919
        Device Specific.(ZB)........00000000
        Device Specific.(ZC)........00040000
        Device Specific.(ZD)........000000FF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C7-T2

Configuration information for adapter fcs2: lscfg -vl fcs2

  fcs2             U78C9.001.WZS0TLH-P1-C3-T1  PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
        Part Number.................00E3495
        EC Level....................D77535
        Customer Card ID Number.....577F
        Manufacturer................001A
        FRU Number..................00E3496
        Device Specific.(ZM)........3
        ROM Level.(alterable).......100300
        Network Address.............10000088ADF497D0
        Device Specific.(Z0)........0000000B
        Device Specific.(Z1)........00000030
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........08090000
        Device Specific.(Z4)........01000001
        Device Specific.(Z5)........2E323532
        Device Specific.(Z6)........2E323532
        Device Specific.(Z7)........C0022B40
        Device Specific.(Z8)........20000088ADF497D0
        Device Specific.(Z9)........10.2.252.1919
        Device Specific.(ZA)........10.2.252.1919
        Device Specific.(ZB)........00000000
        Device Specific.(ZC)........00040000
        Device Specific.(ZD)........000000FF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C3-T1

Configuration information for adapter fcs3: lscfg -vl fcs3

  fcs3             U78C9.001.WZS0TLH-P1-C3-T2  PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
        Part Number.................00E3495
        EC Level....................D77535
        Customer Card ID Number.....577F
        Manufacturer................001A
        FRU Number..................00E3496
        Device Specific.(ZM)........3
        ROM Level.(alterable).......100300
        Network Address.............10000088ADF497D1
        Device Specific.(Z0)........0000000B
        Device Specific.(Z1)........00000030
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........08090000
        Device Specific.(Z4)........01010001
        Device Specific.(Z5)........2E323532
        Device Specific.(Z6)........2E323532
        Device Specific.(Z7)........C0022B40
        Device Specific.(Z8)........20000088ADF497D1
        Device Specific.(Z9)........10.2.252.1919
        Device Specific.(ZA)........10.2.252.1919
        Device Specific.(ZB)........00000000
        Device Specific.(ZC)........00040000
        Device Specific.(ZD)........000000FF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C3-T2

Configuration information for adapter pkcs11: lscfg -vl pkcs11


Configuration information for adapter sissas0: lscfg -vl sissas0

  sissas0          U78C9.001.WZS0TLH-P1-C14-T1  PCIe3 x8 SAS RAID Internal Adapter 6Gb
      PCIe3 x8 Internal SAS Adapter 6Gb               :
        Part Number.................01DH551
        FRU Number..................01DH550
        Manufacture ID..............00UE
        EC Level....................0
        ROM Level.(alterable).......16519400
        Customer Card ID Number.....57D7
        Product Specific.(Z1).......1
        Product Specific.(Z2).......2D35
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C14-T1

Configuration information for adapter sissas1: lscfg -vl sissas1

  sissas1          U78C9.001.WZS0TLH-P1-C15-T1  PCIe3 x8 SAS RAID Internal Adapter 6Gb
      PCIe3 x8 Internal SAS Adapter 6Gb               :
        Part Number.................01DH551
        FRU Number..................01DH550
        Manufacture ID..............00UE
        EC Level....................0
        ROM Level.(alterable).......16519400
        Customer Card ID Number.....57D7
        Product Specific.(Z1).......1
        Product Specific.(Z2).......2D35
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C15-T1

Configuration information for adapter usbhc0: lscfg -vl usbhc0

  usbhc0           U78C9.001.WZS0TLH-P1  Integrated USB 3.0 xHCI Adapter (4c1041821410b204)
        Hardware Location Code......U78C9.001.WZS0TLH-P1

Configuration information for adapter vsa0: lscfg -vl vsa0

  vsa0             U8286.42A.21C096X-V1-C0  LPAR Virtual Serial Adapter
        Hardware Location Code......U8286.42A.21C096X-V1-C0


Detailed attributes for adapter ent0: lsattr -El ent0

adapter_type    ethernet          Adapter Type                                     False
alt_addr        0x000000000000    Alternate Ethernet address                       True
bar0            0x83800000        Bus memory address 0                             False
bar1            0x83000000        Bus memory address 1                             False
bar2            0x84130000        Bus memory address 2                             False
busintr         2048              Bus interrupt level                              False
chksum_offload  yes               Request checksum offload                         True
cksum_ip        yes               Request IP checksum offload                      True
cksum_rx        yes               Request Rx checksum offload                      True
cksum_tcp       yes               Request TCP checksum offload                     True
cksum_udp       yes               Request UDP checksum offload                     True
delay_open      no                Delay open until link state is known             True
eeh_cfgsp_delay 999               EEH config space delay (miliseconds)             False
eeh_pio_bypass  yes               EEH PIO bypass                                   False
eeh_reset_delay 5                 EEH reset delay (seconds)                        False
eeh_reset_type  fundamental_hot   EEH reset type                                   False
flow_ctrl       yes               Request flow control                             True
flow_ctrl_rx    yes               Receive pause frames                             True
flow_ctrl_tx    yes               Transmit pause frames                            True
intr_priority   3                 Interrupt priority                               False
intr_time       24                Interrupt event coalesce timer (microseconds)    True
ipv6_offload    yes               Request IPV6 stateless offloads                  True
jumbo_frames    yes               Request jumbo frames                             True
jumbo_size      9014              Requested jumbo frame size                       False
large_receive   yes               Request Rx TCP segment aggregation               True
large_send      yes               Request Tx TCP segment offload                   True
link_delay_mode logging           Link status delay mode                           True
link_delay_time 5                 Link status delay timer (seconds)                True
link_reset      yes               Perform link reset during suspend                True
lro_threshold   2                 Rx TCP segment aggregation minimum pkt threshold True
media_speed     10000_Full_Duplex Requested Media speed                            True
mgt_comp_cnt    1                 MGT completions before hardware notification     True
mgt_comp_limit  1                 Max MGT completions processed per RSP event      True
mgt_max_events  256               Management queue maximum event count             False
nic             yes               NIC Enablement                                   False
queues_mgt      1                 Requested number of management queues            False
queues_rx       4                 Requested number of Rx queues                    True
queues_tx       1                 Requested number of Tx queues                    True
rsp_comp_cnt    1                 RSP completions before hardware notification     True
rsp_comp_limit  1000              Response queue entries processed per interrupt   True
rsp_max_events  1                 Max RSP events that can be received              False
rx_chain        16                Rx packets chained for stack processing          True
rx_comp_cnt     128               Rx packets per Rx complete notification          True
rx_comp_limit   256               Response queue entries processed per interrupt   True
rx_lowpct_pkts  25                Percentage where RX buffers is considered low    True
rx_max_pkts     2048              Rx queue maximum packet count                    True
rx_send_cnt     8                 Max Rx buffer writes before hardware send call   True
systrc_enable   no                Enable config debug tracing                      True
timer_eeh       0                 EEH event poll timer (seconds)                   True
timer_error     1                 Error poll timer (seconds)                       True
timer_link      1                 Link poll timer (seconds)                        True
timer_stats     1                 Statistics poll timer (seconds)                  True
tx_comp_cnt     128               Tx completions before hardware notification      True
tx_comp_disc    0                 Response events per Tx completion discovery      True
tx_comp_limit   256               Tx completions processed per event               True
tx_delay_free   no                Delay free of Tx packet mbufs                    True
tx_limit        1024              Tx packets sent per transmit thread              True
tx_max_pkts     1024              Tx queue maximum packet count                    True
tx_notify_cnt   32                Tx completion notification injection interval    True
tx_send_cnt     8                 Tx packets chained for adapter processing        True
tx_swq_max_pkts 8192              Software Tx queue maximum packet count           True
use_alt_addr    no                Request alternate Ethernet address               True
vpd_ready_delay 10                VPD ready delay (microseconds)                   False
vpd_timeout     1600              VPD timeout (microseconds)                       False

Detailed attributes for adapter ent1: lsattr -El ent1

adapter_type    ethernet          Adapter Type                                     False
alt_addr        0x000000000000    Alternate Ethernet address                       True
bar0            0x82800000        Bus memory address 0                             False
bar1            0x82000000        Bus memory address 1                             False
bar2            0x84120000        Bus memory address 2                             False
busintr         2049              Bus interrupt level                              False
chksum_offload  yes               Request checksum offload                         True
cksum_ip        yes               Request IP checksum offload                      True
cksum_rx        yes               Request Rx checksum offload                      True
cksum_tcp       yes               Request TCP checksum offload                     True
cksum_udp       yes               Request UDP checksum offload                     True
delay_open      no                Delay open until link state is known             True
eeh_cfgsp_delay 999               EEH config space delay (miliseconds)             False
eeh_pio_bypass  yes               EEH PIO bypass                                   False
eeh_reset_delay 5                 EEH reset delay (seconds)                        False
eeh_reset_type  fundamental_hot   EEH reset type                                   False
flow_ctrl       yes               Request flow control                             True
flow_ctrl_rx    yes               Receive pause frames                             True
flow_ctrl_tx    yes               Transmit pause frames                            True
intr_priority   3                 Interrupt priority                               False
intr_time       24                Interrupt event coalesce timer (microseconds)    True
ipv6_offload    yes               Request IPV6 stateless offloads                  True
jumbo_frames    yes               Request jumbo frames                             True
jumbo_size      9014              Requested jumbo frame size                       False
large_receive   yes               Request Rx TCP segment aggregation               True
large_send      yes               Request Tx TCP segment offload                   True
link_delay_mode logging           Link status delay mode                           True
link_delay_time 5                 Link status delay timer (seconds)                True
link_reset      yes               Perform link reset during suspend                True
lro_threshold   2                 Rx TCP segment aggregation minimum pkt threshold True
media_speed     10000_Full_Duplex Requested Media speed                            True
mgt_comp_cnt    1                 MGT completions before hardware notification     True
mgt_comp_limit  1                 Max MGT completions processed per RSP event      True
mgt_max_events  256               Management queue maximum event count             False
nic             yes               NIC Enablement                                   False
queues_mgt      1                 Requested number of management queues            False
queues_rx       4                 Requested number of Rx queues                    True
queues_tx       1                 Requested number of Tx queues                    True
rsp_comp_cnt    1                 RSP completions before hardware notification     True
rsp_comp_limit  1000              Response queue entries processed per interrupt   True
rsp_max_events  1                 Max RSP events that can be received              False
rx_chain        16                Rx packets chained for stack processing          True
rx_comp_cnt     128               Rx packets per Rx complete notification          True
rx_comp_limit   256               Response queue entries processed per interrupt   True
rx_lowpct_pkts  25                Percentage where RX buffers is considered low    True
rx_max_pkts     2048              Rx queue maximum packet count                    True
rx_send_cnt     8                 Max Rx buffer writes before hardware send call   True
systrc_enable   no                Enable config debug tracing                      True
timer_eeh       0                 EEH event poll timer (seconds)                   True
timer_error     1                 Error poll timer (seconds)                       True
timer_link      1                 Link poll timer (seconds)                        True
timer_stats     1                 Statistics poll timer (seconds)                  True
tx_comp_cnt     128               Tx completions before hardware notification      True
tx_comp_disc    0                 Response events per Tx completion discovery      True
tx_comp_limit   256               Tx completions processed per event               True
tx_delay_free   no                Delay free of Tx packet mbufs                    True
tx_limit        1024              Tx packets sent per transmit thread              True
tx_max_pkts     1024              Tx queue maximum packet count                    True
tx_notify_cnt   32                Tx completion notification injection interval    True
tx_send_cnt     8                 Tx packets chained for adapter processing        True
tx_swq_max_pkts 8192              Software Tx queue maximum packet count           True
use_alt_addr    no                Request alternate Ethernet address               True
vpd_ready_delay 10                VPD ready delay (microseconds)                   False
vpd_timeout     1600              VPD timeout (microseconds)                       False

Detailed attributes for adapter ent2: lsattr -El ent2

adapter_type    ethernet         Adapter Type                                     False
alt_addr        0x000000000000   Alternate Ethernet address                       True
bar0            0x81800000       Bus memory address 0                             False
bar1            0x81000000       Bus memory address 1                             False
bar2            0x84110000       Bus memory address 2                             False
busintr         2050             Bus interrupt level                              False
chksum_offload  yes              Request checksum offload                         True
cksum_ip        yes              Request IP checksum offload                      True
cksum_rx        yes              Request Rx checksum offload                      True
cksum_tcp       yes              Request TCP checksum offload                     True
cksum_udp       yes              Request UDP checksum offload                     True
delay_open      no               Delay open until link state is known             True
eeh_cfgsp_delay 999              EEH config space delay (miliseconds)             False
eeh_pio_bypass  yes              EEH PIO bypass                                   False
eeh_reset_delay 5                EEH reset delay (seconds)                        False
eeh_reset_type  fundamental_hot  EEH reset type                                   False
flow_ctrl       yes              Request flow control                             True
flow_ctrl_rx    yes              Receive pause frames                             True
flow_ctrl_tx    yes              Transmit pause frames                            True
intr_priority   3                Interrupt priority                               False
intr_time       24               Interrupt event coalesce timer (microseconds)    True
ipv6_offload    yes              Request IPV6 stateless offloads                  True
jumbo_frames    no               Request jumbo frames                             True
jumbo_size      9014             Requested jumbo frame size                       False
large_receive   yes              Request Rx TCP segment aggregation               True
large_send      yes              Request Tx TCP segment offload                   True
link_delay_mode logging          Link status delay mode                           True
link_delay_time 5                Link status delay timer (seconds)                True
link_reset      yes              Perform link reset during suspend                True
lro_threshold   2                Rx TCP segment aggregation minimum pkt threshold True
media_speed     Auto_Negotiation Requested Media speed                            True
mgt_comp_cnt    1                MGT completions before hardware notification     True
mgt_comp_limit  1                Max MGT completions processed per RSP event      True
mgt_max_events  256              Management queue maximum event count             False
nic             yes              NIC Enablement                                   False
queues_mgt      1                Requested number of management queues            False
queues_rx       4                Requested number of Rx queues                    True
queues_tx       1                Requested number of Tx queues                    True
rsp_comp_cnt    1                RSP completions before hardware notification     True
rsp_comp_limit  1000             Response queue entries processed per interrupt   True
rsp_max_events  1                Max RSP events that can be received              False
rx_chain        16               Rx packets chained for stack processing          True
rx_comp_cnt     128              Rx packets per Rx complete notification          True
rx_comp_limit   256              Response queue entries processed per interrupt   True
rx_lowpct_pkts  25               Percentage where RX buffers is considered low    True
rx_max_pkts     2048             Rx queue maximum packet count                    True
rx_send_cnt     8                Max Rx buffer writes before hardware send call   True
systrc_enable   no               Enable config debug tracing                      True
timer_eeh       0                EEH event poll timer (seconds)                   True
timer_error     1                Error poll timer (seconds)                       True
timer_link      1                Link poll timer (seconds)                        True
timer_stats     1                Statistics poll timer (seconds)                  True
tx_comp_cnt     128              Tx completions before hardware notification      True
tx_comp_disc    0                Response events per Tx completion discovery      True
tx_comp_limit   256              Tx completions processed per event               True
tx_delay_free   no               Delay free of Tx packet mbufs                    True
tx_limit        1024             Tx packets sent per transmit thread              True
tx_max_pkts     1024             Tx queue maximum packet count                    True
tx_notify_cnt   32               Tx completion notification injection interval    True
tx_send_cnt     8                Tx packets chained for adapter processing        True
tx_swq_max_pkts 8192             Software Tx queue maximum packet count           True
use_alt_addr    no               Request alternate Ethernet address               True
vpd_ready_delay 10               VPD ready delay (microseconds)                   False
vpd_timeout     1600             VPD timeout (microseconds)                       False

Detailed attributes for adapter ent3: lsattr -El ent3

adapter_type    ethernet         Adapter Type                                     False
alt_addr        0x000000000000   Alternate Ethernet address                       True
bar0            0x80800000       Bus memory address 0                             False
bar1            0x80000000       Bus memory address 1                             False
bar2            0x84100000       Bus memory address 2                             False
busintr         2051             Bus interrupt level                              False
chksum_offload  yes              Request checksum offload                         True
cksum_ip        yes              Request IP checksum offload                      True
cksum_rx        yes              Request Rx checksum offload                      True
cksum_tcp       yes              Request TCP checksum offload                     True
cksum_udp       yes              Request UDP checksum offload                     True
delay_open      no               Delay open until link state is known             True
eeh_cfgsp_delay 999              EEH config space delay (miliseconds)             False
eeh_pio_bypass  yes              EEH PIO bypass                                   False
eeh_reset_delay 5                EEH reset delay (seconds)                        False
eeh_reset_type  fundamental_hot  EEH reset type                                   False
flow_ctrl       yes              Request flow control                             True
flow_ctrl_rx    yes              Receive pause frames                             True
flow_ctrl_tx    yes              Transmit pause frames                            True
intr_priority   3                Interrupt priority                               False
intr_time       24               Interrupt event coalesce timer (microseconds)    True
ipv6_offload    yes              Request IPV6 stateless offloads                  True
jumbo_frames    no               Request jumbo frames                             True
jumbo_size      9014             Requested jumbo frame size                       False
large_receive   yes              Request Rx TCP segment aggregation               True
large_send      yes              Request Tx TCP segment offload                   True
link_delay_mode logging          Link status delay mode                           True
link_delay_time 5                Link status delay timer (seconds)                True
link_reset      yes              Perform link reset during suspend                True
lro_threshold   2                Rx TCP segment aggregation minimum pkt threshold True
media_speed     Auto_Negotiation Requested Media speed                            True
mgt_comp_cnt    1                MGT completions before hardware notification     True
mgt_comp_limit  1                Max MGT completions processed per RSP event      True
mgt_max_events  256              Management queue maximum event count             False
nic             yes              NIC Enablement                                   False
queues_mgt      1                Requested number of management queues            False
queues_rx       4                Requested number of Rx queues                    True
queues_tx       1                Requested number of Tx queues                    True
rsp_comp_cnt    1                RSP completions before hardware notification     True
rsp_comp_limit  1000             Response queue entries processed per interrupt   True
rsp_max_events  1                Max RSP events that can be received              False
rx_chain        16               Rx packets chained for stack processing          True
rx_comp_cnt     128              Rx packets per Rx complete notification          True
rx_comp_limit   256              Response queue entries processed per interrupt   True
rx_lowpct_pkts  25               Percentage where RX buffers is considered low    True
rx_max_pkts     2048             Rx queue maximum packet count                    True
rx_send_cnt     8                Max Rx buffer writes before hardware send call   True
systrc_enable   no               Enable config debug tracing                      True
timer_eeh       0                EEH event poll timer (seconds)                   True
timer_error     1                Error poll timer (seconds)                       True
timer_link      1                Link poll timer (seconds)                        True
timer_stats     1                Statistics poll timer (seconds)                  True
tx_comp_cnt     128              Tx completions before hardware notification      True
tx_comp_disc    0                Response events per Tx completion discovery      True
tx_comp_limit   256              Tx completions processed per event               True
tx_delay_free   no               Delay free of Tx packet mbufs                    True
tx_limit        1024             Tx packets sent per transmit thread              True
tx_max_pkts     1024             Tx queue maximum packet count                    True
tx_notify_cnt   32               Tx completion notification injection interval    True
tx_send_cnt     8                Tx packets chained for adapter processing        True
tx_swq_max_pkts 8192             Software Tx queue maximum packet count           True
use_alt_addr    no               Request alternate Ethernet address               True
vpd_ready_delay 10               VPD ready delay (microseconds)                   False
vpd_timeout     1600             VPD timeout (microseconds)                       False

Detailed attributes for adapter ent4: lsattr -El ent4

adapter_type    ethernet          Adapter Type                                     False
alt_addr        0x000000000000    Alternate Ethernet address                       True
bar0            0xc3800000        Bus memory address 0                             False
bar1            0xc3000000        Bus memory address 1                             False
bar2            0xc4130000        Bus memory address 2                             False
busintr         5344              Bus interrupt level                              False
chksum_offload  yes               Request checksum offload                         True
cksum_ip        yes               Request IP checksum offload                      True
cksum_rx        yes               Request Rx checksum offload                      True
cksum_tcp       yes               Request TCP checksum offload                     True
cksum_udp       yes               Request UDP checksum offload                     True
delay_open      no                Delay open until link state is known             True
eeh_cfgsp_delay 999               EEH config space delay (miliseconds)             False
eeh_pio_bypass  yes               EEH PIO bypass                                   False
eeh_reset_delay 5                 EEH reset delay (seconds)                        False
eeh_reset_type  fundamental_hot   EEH reset type                                   False
flow_ctrl       yes               Request flow control                             True
flow_ctrl_rx    yes               Receive pause frames                             True
flow_ctrl_tx    yes               Transmit pause frames                            True
intr_priority   3                 Interrupt priority                               False
intr_time       24                Interrupt event coalesce timer (microseconds)    True
ipv6_offload    yes               Request IPV6 stateless offloads                  True
jumbo_frames    yes               Request jumbo frames                             True
jumbo_size      9014              Requested jumbo frame size                       False
large_receive   yes               Request Rx TCP segment aggregation               True
large_send      yes               Request Tx TCP segment offload                   True
link_delay_mode logging           Link status delay mode                           True
link_delay_time 5                 Link status delay timer (seconds)                True
link_reset      yes               Perform link reset during suspend                True
lro_threshold   2                 Rx TCP segment aggregation minimum pkt threshold True
media_speed     10000_Full_Duplex Requested Media speed                            True
mgt_comp_cnt    1                 MGT completions before hardware notification     True
mgt_comp_limit  1                 Max MGT completions processed per RSP event      True
mgt_max_events  256               Management queue maximum event count             False
nic             yes               NIC Enablement                                   False
queues_mgt      1                 Requested number of management queues            False
queues_rx       4                 Requested number of Rx queues                    True
queues_tx       1                 Requested number of Tx queues                    True
rsp_comp_cnt    1                 RSP completions before hardware notification     True
rsp_comp_limit  1000              Response queue entries processed per interrupt   True
rsp_max_events  1                 Max RSP events that can be received              False
rx_chain        16                Rx packets chained for stack processing          True
rx_comp_cnt     128               Rx packets per Rx complete notification          True
rx_comp_limit   256               Response queue entries processed per interrupt   True
rx_lowpct_pkts  25                Percentage where RX buffers is considered low    True
rx_max_pkts     2048              Rx queue maximum packet count                    True
rx_send_cnt     8                 Max Rx buffer writes before hardware send call   True
systrc_enable   no                Enable config debug tracing                      True
timer_eeh       0                 EEH event poll timer (seconds)                   True
timer_error     1                 Error poll timer (seconds)                       True
timer_link      1                 Link poll timer (seconds)                        True
timer_stats     1                 Statistics poll timer (seconds)                  True
tx_comp_cnt     128               Tx completions before hardware notification      True
tx_comp_disc    0                 Response events per Tx completion discovery      True
tx_comp_limit   256               Tx completions processed per event               True
tx_delay_free   no                Delay free of Tx packet mbufs                    True
tx_limit        1024              Tx packets sent per transmit thread              True
tx_max_pkts     1024              Tx queue maximum packet count                    True
tx_notify_cnt   32                Tx completion notification injection interval    True
tx_send_cnt     8                 Tx packets chained for adapter processing        True
tx_swq_max_pkts 8192              Software Tx queue maximum packet count           True
use_alt_addr    no                Request alternate Ethernet address               True
vpd_ready_delay 10                VPD ready delay (microseconds)                   False
vpd_timeout     1600              VPD timeout (microseconds)                       False

Detailed attributes for adapter ent5: lsattr -El ent5

adapter_type    ethernet          Adapter Type                                     False
alt_addr        0x000000000000    Alternate Ethernet address                       True
bar0            0xc2800000        Bus memory address 0                             False
bar1            0xc2000000        Bus memory address 1                             False
bar2            0xc4120000        Bus memory address 2                             False
busintr         5345              Bus interrupt level                              False
chksum_offload  yes               Request checksum offload                         True
cksum_ip        yes               Request IP checksum offload                      True
cksum_rx        yes               Request Rx checksum offload                      True
cksum_tcp       yes               Request TCP checksum offload                     True
cksum_udp       yes               Request UDP checksum offload                     True
delay_open      no                Delay open until link state is known             True
eeh_cfgsp_delay 999               EEH config space delay (miliseconds)             False
eeh_pio_bypass  yes               EEH PIO bypass                                   False
eeh_reset_delay 5                 EEH reset delay (seconds)                        False
eeh_reset_type  fundamental_hot   EEH reset type                                   False
flow_ctrl       yes               Request flow control                             True
flow_ctrl_rx    yes               Receive pause frames                             True
flow_ctrl_tx    yes               Transmit pause frames                            True
intr_priority   3                 Interrupt priority                               False
intr_time       24                Interrupt event coalesce timer (microseconds)    True
ipv6_offload    yes               Request IPV6 stateless offloads                  True
jumbo_frames    yes               Request jumbo frames                             True
jumbo_size      9014              Requested jumbo frame size                       False
large_receive   yes               Request Rx TCP segment aggregation               True
large_send      yes               Request Tx TCP segment offload                   True
link_delay_mode logging           Link status delay mode                           True
link_delay_time 5                 Link status delay timer (seconds)                True
link_reset      yes               Perform link reset during suspend                True
lro_threshold   2                 Rx TCP segment aggregation minimum pkt threshold True
media_speed     10000_Full_Duplex Requested Media speed                            True
mgt_comp_cnt    1                 MGT completions before hardware notification     True
mgt_comp_limit  1                 Max MGT completions processed per RSP event      True
mgt_max_events  256               Management queue maximum event count             False
nic             yes               NIC Enablement                                   False
queues_mgt      1                 Requested number of management queues            False
queues_rx       4                 Requested number of Rx queues                    True
queues_tx       1                 Requested number of Tx queues                    True
rsp_comp_cnt    1                 RSP completions before hardware notification     True
rsp_comp_limit  1000              Response queue entries processed per interrupt   True
rsp_max_events  1                 Max RSP events that can be received              False
rx_chain        16                Rx packets chained for stack processing          True
rx_comp_cnt     128               Rx packets per Rx complete notification          True
rx_comp_limit   256               Response queue entries processed per interrupt   True
rx_lowpct_pkts  25                Percentage where RX buffers is considered low    True
rx_max_pkts     2048              Rx queue maximum packet count                    True
rx_send_cnt     8                 Max Rx buffer writes before hardware send call   True
systrc_enable   no                Enable config debug tracing                      True
timer_eeh       0                 EEH event poll timer (seconds)                   True
timer_error     1                 Error poll timer (seconds)                       True
timer_link      1                 Link poll timer (seconds)                        True
timer_stats     1                 Statistics poll timer (seconds)                  True
tx_comp_cnt     128               Tx completions before hardware notification      True
tx_comp_disc    0                 Response events per Tx completion discovery      True
tx_comp_limit   256               Tx completions processed per event               True
tx_delay_free   no                Delay free of Tx packet mbufs                    True
tx_limit        1024              Tx packets sent per transmit thread              True
tx_max_pkts     1024              Tx queue maximum packet count                    True
tx_notify_cnt   32                Tx completion notification injection interval    True
tx_send_cnt     8                 Tx packets chained for adapter processing        True
tx_swq_max_pkts 8192              Software Tx queue maximum packet count           True
use_alt_addr    no                Request alternate Ethernet address               True
vpd_ready_delay 10                VPD ready delay (microseconds)                   False
vpd_timeout     1600              VPD timeout (microseconds)                       False

Detailed attributes for adapter ent6: lsattr -El ent6

adapter_type    ethernet         Adapter Type                                     False
alt_addr        0x000000000000   Alternate Ethernet address                       True
bar0            0xc1800000       Bus memory address 0                             False
bar1            0xc1000000       Bus memory address 1                             False
bar2            0xc4110000       Bus memory address 2                             False
busintr         5346             Bus interrupt level                              False
chksum_offload  yes              Request checksum offload                         True
cksum_ip        yes              Request IP checksum offload                      True
cksum_rx        yes              Request Rx checksum offload                      True
cksum_tcp       yes              Request TCP checksum offload                     True
cksum_udp       yes              Request UDP checksum offload                     True
delay_open      no               Delay open until link state is known             True
eeh_cfgsp_delay 999              EEH config space delay (miliseconds)             False
eeh_pio_bypass  yes              EEH PIO bypass                                   False
eeh_reset_delay 5                EEH reset delay (seconds)                        False
eeh_reset_type  fundamental_hot  EEH reset type                                   False
flow_ctrl       yes              Request flow control                             True
flow_ctrl_rx    yes              Receive pause frames                             True
flow_ctrl_tx    yes              Transmit pause frames                            True
intr_priority   3                Interrupt priority                               False
intr_time       24               Interrupt event coalesce timer (microseconds)    True
ipv6_offload    yes              Request IPV6 stateless offloads                  True
jumbo_frames    no               Request jumbo frames                             True
jumbo_size      9014             Requested jumbo frame size                       False
large_receive   yes              Request Rx TCP segment aggregation               True
large_send      yes              Request Tx TCP segment offload                   True
link_delay_mode logging          Link status delay mode                           True
link_delay_time 5                Link status delay timer (seconds)                True
link_reset      yes              Perform link reset during suspend                True
lro_threshold   2                Rx TCP segment aggregation minimum pkt threshold True
media_speed     Auto_Negotiation Requested Media speed                            True
mgt_comp_cnt    1                MGT completions before hardware notification     True
mgt_comp_limit  1                Max MGT completions processed per RSP event      True
mgt_max_events  256              Management queue maximum event count             False
nic             yes              NIC Enablement                                   False
queues_mgt      1                Requested number of management queues            False
queues_rx       4                Requested number of Rx queues                    True
queues_tx       1                Requested number of Tx queues                    True
rsp_comp_cnt    1                RSP completions before hardware notification     True
rsp_comp_limit  1000             Response queue entries processed per interrupt   True
rsp_max_events  1                Max RSP events that can be received              False
rx_chain        16               Rx packets chained for stack processing          True
rx_comp_cnt     128              Rx packets per Rx complete notification          True
rx_comp_limit   256              Response queue entries processed per interrupt   True
rx_lowpct_pkts  25               Percentage where RX buffers is considered low    True
rx_max_pkts     2048             Rx queue maximum packet count                    True
rx_send_cnt     8                Max Rx buffer writes before hardware send call   True
systrc_enable   no               Enable config debug tracing                      True
timer_eeh       0                EEH event poll timer (seconds)                   True
timer_error     1                Error poll timer (seconds)                       True
timer_link      1                Link poll timer (seconds)                        True
timer_stats     1                Statistics poll timer (seconds)                  True
tx_comp_cnt     128              Tx completions before hardware notification      True
tx_comp_disc    0                Response events per Tx completion discovery      True
tx_comp_limit   256              Tx completions processed per event               True
tx_delay_free   no               Delay free of Tx packet mbufs                    True
tx_limit        1024             Tx packets sent per transmit thread              True
tx_max_pkts     1024             Tx queue maximum packet count                    True
tx_notify_cnt   32               Tx completion notification injection interval    True
tx_send_cnt     8                Tx packets chained for adapter processing        True
tx_swq_max_pkts 8192             Software Tx queue maximum packet count           True
use_alt_addr    no               Request alternate Ethernet address               True
vpd_ready_delay 10               VPD ready delay (microseconds)                   False
vpd_timeout     1600             VPD timeout (microseconds)                       False

Detailed attributes for adapter ent7: lsattr -El ent7

adapter_type    ethernet         Adapter Type                                     False
alt_addr        0x000000000000   Alternate Ethernet address                       True
bar0            0xc0800000       Bus memory address 0                             False
bar1            0xc0000000       Bus memory address 1                             False
bar2            0xc4100000       Bus memory address 2                             False
busintr         5347             Bus interrupt level                              False
chksum_offload  yes              Request checksum offload                         True
cksum_ip        yes              Request IP checksum offload                      True
cksum_rx        yes              Request Rx checksum offload                      True
cksum_tcp       yes              Request TCP checksum offload                     True
cksum_udp       yes              Request UDP checksum offload                     True
delay_open      no               Delay open until link state is known             True
eeh_cfgsp_delay 999              EEH config space delay (miliseconds)             False
eeh_pio_bypass  yes              EEH PIO bypass                                   False
eeh_reset_delay 5                EEH reset delay (seconds)                        False
eeh_reset_type  fundamental_hot  EEH reset type                                   False
flow_ctrl       yes              Request flow control                             True
flow_ctrl_rx    yes              Receive pause frames                             True
flow_ctrl_tx    yes              Transmit pause frames                            True
intr_priority   3                Interrupt priority                               False
intr_time       24               Interrupt event coalesce timer (microseconds)    True
ipv6_offload    yes              Request IPV6 stateless offloads                  True
jumbo_frames    no               Request jumbo frames                             True
jumbo_size      9014             Requested jumbo frame size                       False
large_receive   yes              Request Rx TCP segment aggregation               True
large_send      yes              Request Tx TCP segment offload                   True
link_delay_mode logging          Link status delay mode                           True
link_delay_time 5                Link status delay timer (seconds)                True
link_reset      yes              Perform link reset during suspend                True
lro_threshold   2                Rx TCP segment aggregation minimum pkt threshold True
media_speed     Auto_Negotiation Requested Media speed                            True
mgt_comp_cnt    1                MGT completions before hardware notification     True
mgt_comp_limit  1                Max MGT completions processed per RSP event      True
mgt_max_events  256              Management queue maximum event count             False
nic             yes              NIC Enablement                                   False
queues_mgt      1                Requested number of management queues            False
queues_rx       4                Requested number of Rx queues                    True
queues_tx       1                Requested number of Tx queues                    True
rsp_comp_cnt    1                RSP completions before hardware notification     True
rsp_comp_limit  1000             Response queue entries processed per interrupt   True
rsp_max_events  1                Max RSP events that can be received              False
rx_chain        16               Rx packets chained for stack processing          True
rx_comp_cnt     128              Rx packets per Rx complete notification          True
rx_comp_limit   256              Response queue entries processed per interrupt   True
rx_lowpct_pkts  25               Percentage where RX buffers is considered low    True
rx_max_pkts     2048             Rx queue maximum packet count                    True
rx_send_cnt     8                Max Rx buffer writes before hardware send call   True
systrc_enable   no               Enable config debug tracing                      True
timer_eeh       0                EEH event poll timer (seconds)                   True
timer_error     1                Error poll timer (seconds)                       True
timer_link      1                Link poll timer (seconds)                        True
timer_stats     1                Statistics poll timer (seconds)                  True
tx_comp_cnt     128              Tx completions before hardware notification      True
tx_comp_disc    0                Response events per Tx completion discovery      True
tx_comp_limit   256              Tx completions processed per event               True
tx_delay_free   no               Delay free of Tx packet mbufs                    True
tx_limit        1024             Tx packets sent per transmit thread              True
tx_max_pkts     1024             Tx queue maximum packet count                    True
tx_notify_cnt   32               Tx completion notification injection interval    True
tx_send_cnt     8                Tx packets chained for adapter processing        True
tx_swq_max_pkts 8192             Software Tx queue maximum packet count           True
use_alt_addr    no               Request alternate Ethernet address               True
vpd_ready_delay 10               VPD ready delay (microseconds)                   False
vpd_timeout     1600             VPD timeout (microseconds)                       False

Detailed attributes for adapter ent8: lsattr -El ent8

adapter_names   ent0,ent1,ent4,ent5 EtherChannel Adapters                           True
alt_addr        0x000000000000      Alternate EtherChannel Address                  True
auto_recovery   yes                 Enable automatic recovery after failover        True
backup_adapter  NONE                Adapter used when whole channel fails           True
hash_mode       default             Determines how outgoing adapter is chosen       True
interval        long                Determines interval value for IEEE 802.3ad mode True
mode            standard            EtherChannel mode of operation                  True
netaddr         0                   Address to ping                                 True
noloss_failover yes                 Enable lossless failover after ping failure     True
num_retries     3                   Times to retry ping before failing              True
retry_time      1                   Wait time (in seconds) between pings            True
use_alt_addr    no                  Enable Alternate EtherChannel Address           True
use_jumbo_frame no                  Enable Gigabit Ethernet Jumbo Frames            True

Detailed attributes for adapter fcs0: lsattr -El fcs0

DIF_enabled   no         DIF (T10 protection) enabled                       True
bus_mem_addr  0x80108000 Bus memory address                                 False
init_link     auto       INIT Link flags                                    False
intr_msi_1    8192       Bus interrupt level                                False
intr_priority 3          Interrupt priority                                 False
io_dma        64         IO_DMA                                             True
lg_term_dma   0x800000   Long term DMA                                      True
max_xfer_size 0x100000   Maximum Transfer Size                              True
msi_type      msix       MSI Interrupt type                                 False
num_cmd_elems 500        Maximum number of COMMANDS to queue to the adapter True
num_io_queues 1          Desired number of IO queues                        True

Detailed attributes for adapter fcs1: lsattr -El fcs1

DIF_enabled   no         DIF (T10 protection) enabled                       True
bus_mem_addr  0x80100000 Bus memory address                                 False
init_link     auto       INIT Link flags                                    False
intr_msi_1    8193       Bus interrupt level                                False
intr_priority 3          Interrupt priority                                 False
io_dma        64         IO_DMA                                             True
lg_term_dma   0x800000   Long term DMA                                      True
max_xfer_size 0x100000   Maximum Transfer Size                              True
msi_type      msix       MSI Interrupt type                                 False
num_cmd_elems 500        Maximum number of COMMANDS to queue to the adapter True
num_io_queues 1          Desired number of IO queues                        True

Detailed attributes for adapter fcs2: lsattr -El fcs2

DIF_enabled   no         DIF (T10 protection) enabled                       True
bus_mem_addr  0x80108000 Bus memory address                                 False
init_link     auto       INIT Link flags                                    False
intr_msi_1    6144       Bus interrupt level                                False
intr_priority 3          Interrupt priority                                 False
io_dma        64         IO_DMA                                             True
lg_term_dma   0x800000   Long term DMA                                      True
max_xfer_size 0x100000   Maximum Transfer Size                              True
msi_type      msix       MSI Interrupt type                                 False
num_cmd_elems 500        Maximum number of COMMANDS to queue to the adapter True
num_io_queues 1          Desired number of IO queues                        True

Detailed attributes for adapter fcs3: lsattr -El fcs3

DIF_enabled   no         DIF (T10 protection) enabled                       True
bus_mem_addr  0x80100000 Bus memory address                                 False
init_link     auto       INIT Link flags                                    False
intr_msi_1    6145       Bus interrupt level                                False
intr_priority 3          Interrupt priority                                 False
io_dma        64         IO_DMA                                             True
lg_term_dma   0x800000   Long term DMA                                      True
max_xfer_size 0x100000   Maximum Transfer Size                              True
msi_type      msix       MSI Interrupt type                                 False
num_cmd_elems 500        Maximum number of COMMANDS to queue to the adapter True
num_io_queues 1          Desired number of IO queues                        True

Detailed attributes for adapter pkcs11: lsattr -El pkcs11

comp_trace   no Trace Software Crypto    True
io_threads   8  Trace Memory Allocations True
proc_heap_sz 8  Trace Memory Allocations True
trc_adm      no Trace Software Crypto    True
trc_clic     no Trace Software Crypto    True
trc_context  no Trace Software Crypto    True
trc_dd       no Trace Software Crypto    True
trc_hw       no Trace Software Crypto    True
trc_io       no Trace Software Crypto    True
trc_k_klib   no Trace Software Crypto    True
trc_k_ulib   no Trace Software Crypto    True
trc_malloc   no Trace Software Crypto    True
trc_meta     no Trace Software Crypto    True
trc_mmap     no Trace Software Crypto    True
trc_obj      no Trace Software Crypto    True
trc_req      no Trace Software Crypto    True
trc_sess     no Trace Software Crypto    True
trc_slot     no Trace Software Crypto    True
trc_token    no Trace Software Crypto    True
trc_u_lib    no Trace Software Crypto    True
trc_util     no Trace Software Crypto    True
y4_max_req   16 Trace Memory Allocations True

Detailed attributes for adapter sissas0: lsattr -El sissas0

bus_io_addr    0xc0100000                    Bus IO Address             False
intr_msi       14368                         Bus Interrupt Level        False
intr_priority  3                             Interrupt Priority         False
max_cmd_elems  200,400,16                    Cmd limit (JBOD,RAID,SATA) True
max_devices    512                           Attached devices limit     True
max_dma_window 0x2000000,0x4000000,0x2000000 Total DMA limit in bytes   True
nchan          1                             Number of IO channels      True

Detailed attributes for adapter sissas1: lsattr -El sissas1

bus_io_addr    0xe0100000                    Bus IO Address             False
intr_msi       4128                          Bus Interrupt Level        False
intr_priority  3                             Interrupt Priority         False
max_cmd_elems  200,400,16                    Cmd limit (JBOD,RAID,SATA) True
max_devices    512                           Attached devices limit     True
max_dma_window 0x2000000,0x4000000,0x2000000 Total DMA limit in bytes   True
nchan          1                             Number of IO channels      True

Detailed attributes for adapter usbhc0: lsattr -El usbhc0

bus_mem_addr  0xf0000000 Bus memory address            False
bus_mem_addr2 0xf0010000 Bus memory address            False
intr_msi_1    6048       Bus interrupt level           False
intr_priority 0x4        Interrupt priority            False
io_dma        0x4000000  IO DMA                        True
max_slots     8          Maximum USB Devices Supported True
msi_type      msix       MSI Interrupt type            False

Detailed attributes for adapter vsa0: lsattr -El vsa0

desired_mapmem  I/O memory entitlement reserved for device, in bytes False


2017-05-26 07:39:45: Check checkadapters.ksh completed successfully: returncode 0
2017-05-26 07:39:45: Runtime: 1 second(s)
2017-05-26 07:39:45: 0% complete - 223 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:45: Running check script 2 of 224: checkaiooa.ksh

Description:
------------

List the Asynchronous I/O options.

This check script will only provide any output if Asynchronous I/O is defined.

To check if AIO is defined:

# lsdev -C | grep aio

To display the Asynchronous I/O options:

# /usr/sbin/aioo -a

Output:
------------

Command aioo not found on the system.

2017-05-26 07:39:45: Check checkaiooa.ksh completed successfully: returncode 0
2017-05-26 07:39:45: Runtime: 0 second(s)
2017-05-26 07:39:45: 0% complete - 222 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:45: Running check script 3 of 224: checkamepat.ksh

Description:
------------

Run amepat, the Active Memory Expansion planning and advisory tool to report Active Memory Expansion 
information and statistics.

# /usr/bin/amepat

This command will show you if Active Memory Sharing and/or Active Memory Expansion is enabled.

Output:
------------


Command Invoked                : /usr/bin/amepat 

Date/Time of invocation        : Fri May 26 07:39:45 PDT 2017
Total Monitored time           : NA
Total Samples Collected        : NA

System Configuration:
---------------------
Partition Name                 : tsm0001
Processor Implementation Mode  : POWER8 Mode
Number Of Logical CPUs         : 192
Processor Entitled Capacity    : 24.00
Processor Max. Capacity        : 24.00
True Memory                    : 249.75 GB
SMT Threads                    : 8
Shared Processor Mode          : Disabled
Active Memory Sharing          : Disabled
Active Memory Expansion        : Disabled

System Resource Statistics:               Current
---------------------------          ----------------
CPU Util (Phys. Processors)               0.89 [  4%]
Virtual Memory Size (MB)                124083 [ 49%]
True Memory In-Use (MB)                 210209 [ 82%]
Pinned Memory (MB)                       21498 [  8%]
File Cache Size (MB)                     85987 [ 34%]
Available Memory (MB)                   123898 [ 48%]

2017-05-26 07:39:45: Check checkamepat.ksh completed successfully: returncode 0
2017-05-26 07:39:45: Runtime: 0 second(s)
2017-05-26 07:39:46: 1% complete - 221 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:46: Running check script 4 of 224: checkarchitecture.ksh

Description:
------------

Checks the model architecture.

These are the different possible architectures:

chrp: 64-bit Common Hardware Reference Platform (CHRP) architecture; PCI-bus models.

rs6k: Micro Channel-based uni-processor models; also known as mca; micro-channel architecture.

rs6ksmp: Micro Channel-based symmetric multiprocessor models.

rspc: ISA-bus models.

To determine the architecture or hardware platform type on your machine, run:

# bootinfo -p

This will return rs6k, rs6ksmp, rspc or chrp as output. The rspc architecture is nowadays the most 
common.

Output:
------------

Model architecture: chrp

2017-05-26 07:39:46: Check checkarchitecture.ksh completed successfully: returncode 0
2017-05-26 07:39:46: Runtime: 0 second(s)
2017-05-26 07:39:46: 1% complete - 220 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:46: Running check script 5 of 224: checkaudit.ksh

Description:
------------

Display the status of system auditing.

This will run the following command:

# /usr/sbin/audit query

Output:
------------

Current status of audit subsystem: audit query

auditing off
bin processing off
audit events:
	none

audit objects:
	none

2017-05-26 07:39:46: Check checkaudit.ksh completed successfully: returncode 0
2017-05-26 07:39:46: Runtime: 0 second(s)
2017-05-26 07:39:46: 2% complete - 219 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:46: Running check script 6 of 224: checkbindprocessor.ksh

Description:
------------

This check runs bindprocessor -q and bindprocessor -s 0. The output of bindprocessor -q shows the 
available processors in the system. The output of command bindprocessor -s 0 shows the available 
processors that are primary hardware threads.

For example, for a system with 4 physical or virtual processors and SMT=2 enabled, the system will find 
8 processors (4 times 2 = 8; as shown by bindprocessor -q), and 4 physical or virtual processors (as 
shown by bindprocessor -s 0). This way, this check will provide you information about the number of 
processors and the number of actual cores.

Keep in mind though, that processors can be virtual, and thus the number of processors found in the 
system (as shown by bindprocessor -s 0), can be  virtual processors. You need to take into account the 
entitled capacity, which you can see by running:

# lparstat -i | grep "Entitled Capacity"

Also, keep in mind that some systems have multi-threading, and some don't. And some systems have a 
multi-threading of 2 (running 2 threads on 1 processor at the same time), and Power7 systems have a 
multi-threading of 4. You can see this, by running:

# smtctl

Output:
------------

Available processors (includes SMT): bindprocssor -q

The available processors are:  0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 
27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 
95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 
122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 
148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 
174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191

Available physical/virtual processors: bindprocessor -s 0

The available processors are:  0 8 16 24 32 40 48 56 64 72 80 88 96 104 112 120 128 136 144 152 160 168 
176 184

2017-05-26 07:39:46: Check checkbindprocessor.ksh completed successfully: returncode 0
2017-05-26 07:39:46: Runtime: 0 second(s)
2017-05-26 07:39:46: 2% complete - 218 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:46: Running check script 7 of 224: checkbootdevice.ksh

Description:
------------

Checks the device the system has booted from.

To check the boot device, run:

# bootinfo -b

Output:
------------

hdisk0

2017-05-26 07:39:46: Check checkbootdevice.ksh completed successfully: returncode 0
2017-05-26 07:39:46: Runtime: 0 second(s)
2017-05-26 07:39:46: 3% complete - 217 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:46: Running check script 8 of 224: checkbootptab.ksh

Description:
------------

Check for any entries in /etc/bootptab.

This file is commonly found on any AIX server that acts as a NIM server, for the purpose of booting 
over the network. The bootp protocol requires this configuration file.

This will run the following command:

# grep -v ^# /etc/bootptab

Which will display all active entries in /etc/bootptab.

Output:
------------

No entries found in /etc/bootptab.

2017-05-26 07:39:46: Check checkbootptab.ksh completed successfully: returncode 0
2017-05-26 07:39:46: Runtime: 0 second(s)
2017-05-26 07:39:46: 3% complete - 216 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:46: Running check script 9 of 224: checkbosdebug.ksh

Description:
------------

Displays the status of debugging features of the system.

It will run the following command:

/usr/sbin/bosdebug -L

Output:
------------

Memory debugger           off
Memory sizes              0
Network memory sizes      0
Kernel debugger           off
Real Time Kernel          off
Backtracking fault log    on
Kernext Memory Tracking   off

2017-05-26 07:39:47: Check checkbosdebug.ksh completed successfully: returncode 0
2017-05-26 07:39:47: Runtime: 0 second(s)
2017-05-26 07:39:47: 4% complete - 215 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:47: Running check script 10 of 224: checkcaalscluster.ksh

Description:
------------

Display the output of the lscluster command when a CAA cluster is present.

CAA is short for cluster aware AIX. CAA has been introduced in AIX 7.1 and later versions of AIX 6.1, 
and is a requirement for PowerHA 7.1.

Output:
------------

Cluster configuration (lscluster -c):

Cluster Name: tsm0000_cluster
Cluster UUID: 38a54e9e-bbfa-11e6-8003-fab08625bd9c
Number of nodes in cluster = 2
	Cluster ID for node tsm0001: 1
	Primary IP address for node tsm0001: 192.18.42.43
	Cluster ID for node tsm0002: 2
	Primary IP address for node tsm0002: 192.18.42.44
Number of disks in cluster = 1
	Disk = hdisk26 UUID = d1db6a9c-c36c-c743-0ddc-09d4ee6a1203 cluster_major = 0 cluster_minor = 1
Multicast for site LOCAL: IPv4 228.16.52.43 IPv6 ff05::e410:342b
Communication Mode: unicast
Local node maximum capabilities: CAA_NETMON, AUTO_REPOS_REPLACE, HNAME_CHG, UNICAST, IPV6, SITE
Effective cluster-wide capabilities: CAA_NETMON, AUTO_REPOS_REPLACE, HNAME_CHG, UNICAST, IPV6, SITE
Local node max level: 40000
Effective cluster level: 40000

Cluster node configuration information (lscluster -m):

Calling node query for all nodes...
Node query number of nodes examined: 2

	Node name: tsm0001
	Cluster shorthand id for node: 1
	UUID for node: 387f0e28-bbfa-11e6-8003-fab08625bd9c
	State of node: UP  NODE_LOCAL 
	Smoothed rtt to node: 0
	Mean Deviation in network rtt to node: 0
	Number of clusters node is a member in: 1
	CLUSTER NAME       SHID         UUID                                
	tsm0000_cluster   0            38a54e9e-bbfa-11e6-8003-fab08625bd9c
	SITE NAME          SHID         UUID                                
	LOCAL              1            51735173-5173-5173-5173-517351735173

	Points of contact for node: 0

----------------------------------------------------------------------------

	Node name: tsm0002
	Cluster shorthand id for node: 2
	UUID for node: 387f0e78-bbfa-11e6-8003-fab08625bd9c
	State of node: UP 
	Smoothed rtt to node: 7
	Mean Deviation in network rtt to node: 3
	Number of clusters node is a member in: 1
	CLUSTER NAME       SHID         UUID                                
	tsm0000_cluster   0            38a54e9e-bbfa-11e6-8003-fab08625bd9c
	SITE NAME          SHID         UUID                                
	LOCAL              1            51735173-5173-5173-5173-517351735173

	Points of contact for node: 1
	-----------------------------------------------------------------------
	Interface     State  Protocol    Status     SRC_IP->DST_IP
	-----------------------------------------------------------------------
	tcpsock->02   UP     IPv4         none   192.18.42.43->192.18.42.44

Cluster network configuration (lscluster -i):

Network/Storage Interface Query

Cluster Name: tsm0000_cluster
Cluster UUID: 38a54e9e-bbfa-11e6-8003-fab08625bd9c
Number of nodes reporting = 2
Number of nodes stale = 0
Number of nodes expected = 2

Node tsm0001
Node UUID = 387f0e28-bbfa-11e6-8003-fab08625bd9c
Number of interfaces discovered = 2
	Interface number 1, en8
		IFNET type = 6 (IFT_ETHER)
		NDD type = 7 (NDD_ISO88023)
		MAC address length = 6
		MAC address = 98:BE:94:69:85:98
		Smoothed RTT across interface = 0
		Mean deviation in network RTT across interface = 0
		Probe interval for interface = 990 ms
		IFNET flags for interface = 0x1E084863
		NDD flags for interface = 0x0065081B
		Interface state = UP
		Number of regular addresses configured on interface = 2
		IPv4 ADDRESS: 192.18.42.43 broadcast 192.18.42.255 netmask 255.255.255.0
		IPv4 ADDRESS: 192.18.42.45 broadcast 192.18.42.255 netmask 255.255.255.0
		Number of cluster multicast addresses configured on interface = 1
		IPv4 MULTICAST ADDRESS: 228.16.52.43
	Interface number 2, dpcom
		IFNET type = 0 (none)
		NDD type = 305 (NDD_PINGCOMM)
		Smoothed RTT across interface = 530
		Mean deviation in network RTT across interface = 799
		Probe interval for interface = 13290 ms
		IFNET flags for interface = 0x00000000
		NDD flags for interface = 0x00000009
		Interface state = UP RESTRICTED AIX_CONTROLLED

Node tsm0002
Node UUID = 387f0e78-bbfa-11e6-8003-fab08625bd9c
Number of interfaces discovered = 2
	Interface number 1, en8
		IFNET type = 6 (IFT_ETHER)
		NDD type = 7 (NDD_ISO88023)
		MAC address length = 6
		MAC address = 98:BE:94:69:85:78
		Smoothed RTT across interface = 0
		Mean deviation in network RTT across interface = 0
		Probe interval for interface = 990 ms
		IFNET flags for interface = 0x1E084863
		NDD flags for interface = 0x0065081B
		Interface state = UP
		Number of regular addresses configured on interface = 1
		IPv4 ADDRESS: 192.18.42.44 broadcast 192.18.42.255 netmask 255.255.255.0
		Number of cluster multicast addresses configured on interface = 1
		IPv4 MULTICAST ADDRESS: 228.16.52.43
	Interface number 2, dpcom
		IFNET type = 0 (none)
		NDD type = 305 (NDD_PINGCOMM)
		Smoothed RTT across interface = 472
		Mean deviation in network RTT across interface = 656
		Probe interval for interface = 11280 ms
		IFNET flags for interface = 0x00000000
		NDD flags for interface = 0x00000009
		Interface state = UP RESTRICTED AIX_CONTROLLED

Cluster network statistics (lscluster -s):

Cluster Network Statistics:

pkts seen: 11619739314                passed: 11628425282
IP pkts: 11629170613                  UDP pkts: 155227
gossip pkts sent: 934712              gossip pkts recv: 934723
cluster address pkts: 0               CP pkts: 2505656
bad transmits: 6                      bad posts: 1
Bad transmit (overflow - disk ): 0
Bad transmit (overflow - tcpsock): 0
Bad transmit (host unreachable): 0
Bad transmit (net unreachable): 0
Bad transmit (network down): 0
Bad transmit (no connection): 0
short pkts: 0                         multicast pkts: 189
cluster wide errors: 0                bad pkts: 0
dup pkts: 13                          dropped pkts: 1
pkt fragments: 10473                  fragments queued: 0
fragments freed: 0
pkts pulled: 0                        no memory: 0
rxmit requests recv: 8                requests found: 7
requests missed: 1                    ooo pkts: 0
requests reset sent: 1                reset recv: 0
remote tcpsock send: 2495152          tcpsock recv: 4990095
rxmit requests sent: 1               
alive pkts sent: 0                    alive pkts recv: 0
ahafs pkts sent: 46                   ahafs pkts recv: 3
nodedown pkts sent: 0                 nodedown pkts recv: 0
socket pkts sent: 47515               socket pkts recv: 47512
cwide pkts sent: 372990               cwide pkts recv: 372990
socket pkts no space: 0               pkts recv notforhere: 0
Pseudo socket pkts sent: 0            Pseudo socket pkts recv: 0
Pseudo socket pkts dropped: 0
arp pkts sent: 1                      arp pkts recv: 1
stale pkts recv: 0                    other cluster pkts: 2
storage pkts sent: 0                  storage pkts recv: 0
disk pkts sent: 258                   disk pkts recv: 189
unicast pkts sent: 434775             unicast pkts recv: 72425
out-of-range pkts recv: 0            
IPv6 pkts sent: 0                     IPv6 pkts recv: 0
IPv6 frags sent: 0                    IPv6 frags recv: 0
Unhandled large pkts: 0               
mrxmit overflow     : 0               urxmit overflow: 0
Multicast ping pkts sent: 21726

Cluster storage information (lscluster -d):

Storage Interface Query

Cluster Name: tsm0000_cluster
Cluster UUID: 38a54e9e-bbfa-11e6-8003-fab08625bd9c
Number of nodes reporting = 2
Number of nodes expected = 2

Node tsm0001
Node UUID = 387f0e28-bbfa-11e6-8003-fab08625bd9c
Number of disks discovered = 1
	hdisk26:
	      State : UP
	       uDid : 32110000e8f4-000000030ECompellent Vol08COMPELNTfcp
	       uUid : d1db6a9c-c36c-c743-0ddc-09d4ee6a1203
	  Site uUid : 51735173-5173-5173-5173-517351735173
	       Type : REPDISK

Node tsm0002
Node UUID = 387f0e78-bbfa-11e6-8003-fab08625bd9c
Number of disks discovered = 1
	hdisk26:
	      State : UP
	       uDid : 32110000e8f4-000000030ECompellent Vol08COMPELNTfcp
	       uUid : d1db6a9c-c36c-c743-0ddc-09d4ee6a1203
	  Site uUid : 51735173-5173-5173-5173-517351735173
	       Type : REPDISK

2017-05-26 07:39:47: Check checkcaalscluster.ksh completed successfully: returncode 0
2017-05-26 07:39:47: Runtime: 0 second(s)
2017-05-26 07:39:47: 4% complete - 214 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:47: Running check script 11 of 224: checkchangedfilesinetc.ksh

Description:
------------

Checks for any changed files in /etc within the last 24 hours.

It will run the following command:

# find /etc -ctime 1 -type f -ls

Review any files that have been changed or created within /etc, to make sure the changes are correct.

Output:
------------

The following file(s) have been changed or created in /etc in the last 24 hours:
  149    2 -rw-------  1 root      security      1067 May 26 00:01 /etc/security/passwd
  161   13 -rw-r-----  1 root      security     12978 May 26 00:01 /etc/security/user

2017-05-26 07:39:47: Check checkchangedfilesinetc.ksh completed successfully: returncode 0
2017-05-26 07:39:47: Runtime: 0 second(s)
2017-05-26 07:39:47: 4% complete - 213 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:47: Running check script 12 of 224: checkchdef.ksh

Description:
------------

Check if there are any defaults set for devices using the chdef command.

The chdef command is a useful command that can be used to set attributes of devices to specific default 
values. For example, it can be used to set the hcheck_interval by default to 60 (where the default is 0 
on AIX) for all vscsi devices, using the following command:

# chdef -a hcheck_interval=60  -c disk -s vscsi -t vdisk

To list out any defaults that have been set, you can run the chdev command by itself:

# chdef -H

For more information about the chdef command, check the manual page of the chdef command, or check the 
following URL: 
https://www.ibm.com/developerworks/community/blogs/brian/entry/change_aix_device_default_attributes_with
_chdef_command?lang=en

2017-05-26 07:39:47: Check checkchdef.ksh completed successfully: returncode 0
2017-05-26 07:39:47: Runtime: 0 second(s)
2017-05-26 07:39:47: 5% complete - 212 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:47: Running check script 13 of 224: checkcompellentdellsctune.ksh

Description:
------------

This check script will display the output o the Dell EMC SC / Compellent dellsc_tune command.

This check script only applies to AIX systems that use Dell EMC SC / Compellent storage, and that have 
the Dell Storage Software Suite for AIX installed, version 3.0.1.6 or up.

The dellsc_tune command can be used to tune the system to either the robust or performance profile. 

To view the active profile, run:

# /usr/lpp/DellSC_MPAIX/dellsc_tune active

To change from one profile to another, type the "dellsc_tune profile [profile_name] command, where 
[profile_name] is the profile type you want to switch to. The options are:

- performance: This profile focuses o performance over reliability by removing the pdisk devices from 
the Storage Suite package (as seen by the ls_dellsc command, where pdisk devices are replaced by fscsi 
device references).
- robust: This performance profile focuses on reliability over performance. This is the default option.

Output:
------------

Current active profile is robust

2017-05-26 07:39:47: Check checkcompellentdellsctune.ksh completed successfully: returncode 0
2017-05-26 07:39:47: Runtime: 0 second(s)
2017-05-26 07:39:47: 5% complete - 211 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:47: Running check script 14 of 224: checkcompellentshowwwid.ksh

Description:
------------

Check the output of the Dell EMC SC / Compellent show_wwid command.

The show_wwid command displays a correlation of fcs devices to their respective vFC World Wide Port 
Name (WWPN) identifiers:

# /usr/sbin/show_wwid

Output:
------------

Output of the show_wwid command:
fcs0: 10000088ADF49803
fcs1: 10000088ADF49804
fcs2: 10000088ADF497D0
fcs3: 10000088ADF497D1

2017-05-26 07:39:47: Check checkcompellentshowwwid.ksh completed successfully: returncode 0
2017-05-26 07:39:47: Runtime: 0 second(s)
2017-05-26 07:39:47: 6% complete - 210 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:48: Running check script 15 of 224: checkcorenaming.ksh

Description:
------------

Check if the environment variable CORE_NAMING is set in /etc/environment. This variable can be set to 
create unique core files for each core dump.

This will run the following command:

# grep CORE_NAMING /etc/environment

Before AIX 5L Version 5.1, a core file was always stored in a file named core. If the same or another 
application generated another core file before you renamed the previous one, the original content was 
lost.

Beginning with AIX 5L Version 5.1, you can enable a unique naming of core files, but be aware that the 
default behavior is to name the files core. You apply the new enhancement by setting the environment 
variable CORE_NAMING to a non-NULL value, for example:

CORE_NAMING=yes

After setting CORE_NAMING, you can disable this feature by setting the variable to the NULL value. For 
example, if you are using the Korn shell, do the following:

export CORE_NAMING=

After setting CORE_NAMING, all new core will be stored in files of the format core.pid.ddhhmmss, where:

pid 
 Process ID
dd 
 Day of the month
hh 
 Hours
mm 
 Minutes
ss 
 Seconds
 
In the following example, two core files are generated by a process identified by PID 30480 at 
different times:

$ ls -l core*
-rw-r--r--   1 ausres01 itsores        8179 Jan 28 2003  core.30480.28232347
-rw-r--r--   1 ausres01 itsores        8179 Jan 28 2003  core.30482.28232349

The time stamp used is in GMT [1] and your time zone will not be used.

Output:
------------

Not enabled.

2017-05-26 07:39:48: Check checkcorenaming.ksh completed successfully: returncode 0
2017-05-26 07:39:48: Runtime: 0 second(s)
2017-05-26 07:39:48: 6% complete - 209 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:48: Running check script 16 of 224: checkcoresettings.ksh

Description:
------------

Check the default settings for core files by running lscore.

This will run the following command:

# /usr/bin/lscore

Output:
------------

compression: on
path specification: off
corefile location: not set
naming specification: off

2017-05-26 07:39:48: Check checkcoresettings.ksh completed successfully: returncode 0
2017-05-26 07:39:48: Runtime: 0 second(s)
2017-05-26 07:39:48: 7% complete - 208 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:48: Running check script 17 of 224: checkcpu.ksh

Description:
------------

This script displays the CPU information by running:

# lsdev -Cc processor

And by running for each processor, for example for processor proc1:

# lsattr -El proc1

Output:
------------

proc0   Available 00-00  Processor
proc8   Available 00-08  Processor
proc16  Available 00-16  Processor
proc24  Available 00-24  Processor
proc32  Available 00-32  Processor
proc40  Available 00-40  Processor
proc48  Available 00-48  Processor
proc56  Available 00-56  Processor
proc64  Available 00-64  Processor
proc72  Available 00-72  Processor
proc80  Available 00-80  Processor
proc88  Available 00-88  Processor
proc96  Available 00-96  Processor
proc104 Available 00-104 Processor
proc112 Available 00-112 Processor
proc120 Available 00-120 Processor
proc128 Available 00-128 Processor
proc136 Available 00-136 Processor
proc144 Available 00-144 Processor
proc152 Available 00-152 Processor
proc160 Available 00-160 Processor
proc168 Available 00-168 Processor
proc176 Available 00-176 Processor
proc184 Available 00-184 Processor

proc0

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc8

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc16

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc24

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc32

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc40

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc48

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc56

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc64

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc72

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc80

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc88

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc96

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc104

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc112

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc120

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc128

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc136

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc144

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc152

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc160

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc168

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc176

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False

proc184

frequency   3525000000     Processor Speed       False
smt_enabled true           Processor SMT enabled False
smt_threads 8              Processor SMT threads False
state       enable         Processor state       False
type        PowerPC_POWER8 Processor type        False


2017-05-26 07:39:48: Check checkcpu.ksh completed successfully: returncode 0
2017-05-26 07:39:48: Runtime: 0 second(s)
2017-05-26 07:39:48: 7% complete - 207 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:48: Running check script 18 of 224: checkcpucount.ksh

Description:
------------

Displays the number of CPUs. 

Depending on the type of server, these are either physical CPUs for full system partitions or logical 
CPUs for shared partitions.

It will run the following command:

# lsdev -Cc processor

Output:
------------

24

2017-05-26 07:39:48: Check checkcpucount.ksh completed successfully: returncode 0
2017-05-26 07:39:48: Runtime: 0 second(s)
2017-05-26 07:39:48: 8% complete - 206 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:48: Running check script 19 of 224: checkcpumodel.ksh

Description:
------------

Shows the CPU model.

This script will generate a warning message if the server is a Power5 system or older.

Generally speaking, it is often better to replace very old hardware, then to hold on to it. It's not 
uncommon that the cost for yearly IBM Hardware and Software support is often (much) higher for old 
hardware, compared to the cost to buy new (e.g. Power8) hardware with 3 years of warranty included. 
Also, old hardware is more likely to break down and to cause downtime. 

Power5 hardware has been replaced by IBM in June 2007, meaning that most Power5 hardware nowadays is at 
least 7 years old, well beyond the default 3 year warranty term, and thus it is recommended to replace 
any hardware of type Power5 or older. Note that even for Power6 hardware that exceeds the 3 year 
warranty term, it can be interesting to inquire about replacing the hardware with Power7 hardware, that 
includes a new 3-year warranty, to bring down the cost of hardware and software support - and increase 
the system performance at the same time, due to higher available CPU clock rates.

Output:
------------

PowerPC_POWER8

2017-05-26 07:39:48: Check checkcpumodel.ksh completed successfully: returncode 0
2017-05-26 07:39:48: Runtime: 0 second(s)
2017-05-26 07:39:48: 8% complete - 205 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:48: Running check script 20 of 224: checkcpuspeed.ksh

Description:
------------

Displays the speed of the CPUs in MHz.

The following command is run:

# /usr/sbin/prtconf -s

Output:
------------

3525 MHz

2017-05-26 07:39:49: Check checkcpuspeed.ksh completed successfully: returncode 0
2017-05-26 07:39:49: Runtime: 0 second(s)
2017-05-26 07:39:49: 8% complete - 204 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:49: Running check script 21 of 224: checkcronallowdeny.ksh

Description:
------------

This check script will display the contents of the /var/adm/cron/cron.allow, /var/adm/cron/cron.deny, 
/var/adm/cron/at.allow and /var/adm/cron/at.deny files.

Output:
------------

/var/adm/cron/cron.allow
File /var/adm/cron/cron.allow does not exist.

/var/adm/cron/cron.deny
File /var/adm/cron/cron.deny is empty.

/var/adm/cron/at.allow
File /var/adm/cron/at.allow does not exist.

/var/adm/cron/at.deny
File /var/adm/cron/at.deny is empty.

2017-05-26 07:39:49: Check checkcronallowdeny.ksh completed successfully: returncode 0
2017-05-26 07:39:49: Runtime: 0 second(s)
2017-05-26 07:39:49: 9% complete - 203 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:49: Running check script 22 of 224: checkcronqueuedefs.ksh

Description:
------------

Check if there are any specific Cron queue definitions set.

The /var/adm/cron/queuedefs file can be used to set specific settings for the cron daemon, such as 
which nice value to use when running processes, or how many processes to run concurrently.

The following command is run by this check script:

# grep -v "^#" /var/adm/cron/queuedefs

2017-05-26 07:39:49: Check checkcronqueuedefs.ksh completed successfully: returncode 0
2017-05-26 07:39:49: Runtime: 0 second(s)
2017-05-26 07:39:49: 9% complete - 202 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:49: Running check script 23 of 224: checkcrontab.ksh

Description:
------------

Displays the contents of all the crontab files.

These files can be found in /var/spool/cron/crontabs.

Output:
------------

Crontab for user root:

0 3 * * * /usr/sbin/skulker > /dev/null 2>&1
0 11 * * * /usr/bin/errclear -d S,O 30
0 12 * * * /usr/bin/errclear -d H 90
0,5,10,15,20,25,30,35,40,45,50,55 * * * * /usr/sbin/dumpctrl -k >/dev/null 2>/dev/null
0 15 * * *  /usr/lib/ras/dumpcheck >/dev/null 2>&1
55 23 * * * /var/perf/pm/bin/pmcfg  >/dev/null 2>&1     #Enable PM Data Collection
0 0 * * * /usr/es/sbin/cluster/utilities/clcycle 1>/dev/null 2>/dev/null # PowerHA SystemMirror Logfile 
rotation
10 0 * * * /usr/local/bin/mksysb.ksh 1>/dev/null 2>&1 # Run a local mksysb to /mksysb and copy it to 
the other node.
0 0 * * * /usr/local/bin/collect_nmon.ksh 1>/tmp/collect_nmon.ksh.log 2>&1 # Run nmon and collect nmon 
data.
1 0 * * * /usr/local/bin/fixuser.ksh 1>/dev/null 2>&1 # Fix user accounts for continued root access.
2 0 * * * /usr/local/bin/sync.ksh 1>/dev/null 2>&1 # Synchronize important files between cluster nodes.
0 * * * * /usr/local/bin/checkerrpthour.ksh >/dev/null 2>&1 # Check the error report every hour.
0 3 * * * /usr/local/bin/trimlog.ksh 1>/dev/null 2>&1 # Trim and rotate log files automatically.
9 3 * * * /usr/local/bin/checkcronlogfailed.ksh 1>/dev/null 2>&1 # Check failed cron jobs.
5 4 * * 1 /usr/local/bin/microcodesurvey.ksh 1>/dev/null 2>&1 # Microcode survey script.

2017-05-26 07:39:49: Check checkcrontab.ksh completed successfully: returncode 0
2017-05-26 07:39:49: Runtime: 0 second(s)
2017-05-26 07:39:49: 10% complete - 201 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:49: Running check script 24 of 224: checkdb2folder.ksh

Description:
------------

Displays the installation folder(s) for DB2.

The information about the installation folder can be found in /var/db2/global.reg, if DB2 is installed.

Output:
------------

DB2 installed in: /opt/tivoli/tsm/db2

2017-05-26 07:39:49: Check checkdb2folder.ksh completed successfully: returncode 0
2017-05-26 07:39:49: Runtime: 0 second(s)
2017-05-26 07:39:49: 10% complete - 200 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:49: Running check script 25 of 224: checkdb2level.ksh

Description:
------------

Displays the level(s) of DB2 software installed.

The following command is run by this check script:

# lslpp -l | grep db2

2017-05-26 07:39:49: Check checkdb2level.ksh completed successfully: returncode 0
2017-05-26 07:39:49: Runtime: 0 second(s)
2017-05-26 07:39:49: 11% complete - 199 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:49: Running check script 26 of 224: checkdf.ksh

Description:
------------

This check script will display the output of the df -gv command, which will display the file systems on 
the system, with gigabytes in all columns.

Output:
------------

Filesystem    GB blocks      Used      Free %Used    Iused    Ifree %Iused Mounted on
/dev/hd4           2.00      0.08      1.92    5%     4773   451393     2% /
/dev/hd2          13.00      2.47     10.53   19%    43675  2462290     2% /usr
/dev/hd9var       10.00      0.39      9.61    4%     2264  2245410     1% /var
/dev/hd3          10.00      0.01      9.99    1%      110  2334334     1% /tmp
/dev/hd1          10.00      0.03      9.97    1%      130  2324713     1% /home
/dev/hd11admin      1.00      0.00      1.00    1%        5   232992     1% /admin
/proc                 -         -         -    -        -        -      - /proc
/dev/hd10opt      10.00      5.50      4.50   56%    26281  1053830     3% /opt
/dev/livedump      1.00      0.00      1.00    1%        4   232993     1% /var/adm/ras/livedump
/dev/mksysblv    100.00     72.78     27.22   73%       28  6341950     1% /mksysb
/aha                  -         -         -    -       93    32675     1% /aha
/dev/tsmactloglv    299.50    132.55    166.95   45%      272 38903073     1% /tsmactlog
/dev/tsmappslv     29.50     25.22      4.28   86%     3348   996809     1% /tsmapps
/dev/tsmarchloglv   2044.00     38.21   2005.79    2%       82 467386642     1% /tsmarchlog
/dev/tsmarchlog2lv   2044.00      2.31   2041.69    1%       10 475749141     1% /tsmarchlog2
/dev/tsmdb01lv    250.00     32.48    217.52   13%      115 50686249     1% /tsmdb/tsmdb01
/dev/tsmdb02lv    250.00     32.48    217.52   13%      111 50686257     1% /tsmdb/tsmdb02
/dev/tsmdb03lv    250.00     32.48    217.52   13%      110 50686254     1% /tsmdb/tsmdb03
/dev/tsmdb04lv    250.00     32.48    217.52   13%      111 50686255     1% /tsmdb/tsmdb04
/dev/tsmdb05lv    250.00     32.48    217.52   13%      113 50686251     1% /tsmdb/tsmdb05
/dev/tsmdb06lv    250.00     32.48    217.52   13%      108 50686259     1% /tsmdb/tsmdb06
/dev/tsmdb07lv    250.00     32.48    217.52   13%      111 50686253     1% /tsmdb/tsmdb07
/dev/tsmdb08lv    250.00     32.48    217.52   13%      114 50686249     1% /tsmdb/tsmdb08
/dev/tsmdb09lv    250.00     32.48    217.52   13%      113 50686250     1% /tsmdb/tsmdb09
/dev/tsmdb10lv    250.00     32.48    217.52   13%      115 50686245     1% /tsmdb/tsmdb10
/dev/tsmdb11lv    250.00     32.48    217.52   13%      115 50686249     1% /tsmdb/tsmdb11
/dev/tsmdb12lv    250.00     32.48    217.52   13%      113 50686252     1% /tsmdb/tsmdb12
/dev/tsmdbbkp01lv   7160.00    233.04   6926.96    4%       10 1614098937     1% /tsmdbbkp/tsmdbbkp01
/dev/tsmdbbkp02lv   7160.00    216.22   6943.78    4%       10 1618017751     1% /tsmdbbkp/tsmdbbkp02
/dev/tsmdbbkp03lv   7160.00    261.20   6898.80    4%       10 1607536576     1% /tsmdbbkp/tsmdbbkp03
/dev/tsmdbbkp04lv   7160.00    254.03   6905.97    4%       10 1609207742     1% /tsmdbbkp/tsmdbbkp04
/dev/tsmfs01lv  16352.00   2248.02  14103.98   14%       52 3286464859     1% /tsmfs01/tsmfs01
/dev/tsmfs02lv  16352.00   1961.81  14390.19   12%       48 3353158750     1% /tsmfs01/tsmfs02
/dev/tsmfs03lv  16352.00   2007.40  14344.60   13%       48 3342535288     1% /tsmfs01/tsmfs03
/dev/tsmfs04lv  16352.00   2555.28  13796.72   16%       58 3214868399     1% /tsmfs01/tsmfs04
/dev/tsmfs05lv  16352.00   2315.92  14036.08   15%       53 3270643970     1% /tsmfs01/tsmfs05
/dev/tsmfs06lv  16352.00   2546.02  13805.98   16%       58 3217027842     1% /tsmfs01/tsmfs06
/dev/tsmfs07lv  16352.00   2412.63  13939.37   15%       56 3248108932     1% /tsmfs01/tsmfs07
/dev/tsmfs08lv  16352.00   2355.36  13996.64   15%       54 3261454559     1% /tsmfs01/tsmfs08
/dev/tsmfs09lv  16352.00   1907.25  14444.75   12%       45 3365871998     1% /tsmfs01/tsmfs09
/dev/tsmfs10lv  16352.00   2259.55  14092.45   14%       53 3283779835     1% /tsmfs01/tsmfs10
/dev/tsmfs11lv  16352.00   1757.91  14594.09   11%       44 3400669069     1% /tsmfs01/tsmfs11
/dev/tsmfs12lv  16352.00   2205.27  14146.73   14%       51 3296426403     1% /tsmfs02/tsmfs12
/dev/tsmfs13lv  16352.00   2819.24  13532.76   18%       64 3153362627     1% /tsmfs02/tsmfs13
/dev/tsmfs14lv  16352.00   2056.57  14295.43   13%       48 3331076281     1% /tsmfs02/tsmfs14
/dev/tsmfs15lv  16352.00   2274.87  14077.13   14%       52 3280209708     1% /tsmfs02/tsmfs15
/dev/tsmfs16lv  16352.00   2314.94  14037.06   15%       57 3270871448     1% /tsmfs02/tsmfs16
/dev/tsmfs17lv  16352.00   2526.22  13825.78   16%       58 3221641569     1% /tsmfs02/tsmfs17
/dev/tsmfs18lv  16352.00   2138.01  14213.99   14%       51 3312098900     1% /tsmfs02/tsmfs18
/dev/tsmfs19lv  16352.00   2194.78  14157.22   14%       52 3298872749     1% /tsmfs02/tsmfs19
/dev/tsmfs20lv  16352.00   2555.35  13796.65   16%       58 3214852435     1% /tsmfs02/tsmfs20
/dev/tsmfs21lv  16352.00   2255.12  14096.88   14%       52 3284811301     1% /tsmfs02/tsmfs21
/dev/tsmfs22lv  16352.00   2212.10  14139.90   14%       52 3294835921     1% /tsmfs02/tsmfs22
/dev/tsmhomelv     49.88      0.47     49.41    1%      296 11513127     1% /tsmhome
/dev/tsmrecoverylv    399.50      0.56    398.94    1%       17 92959490     1% /tsmrecovery
/dev/exportlv     20.00      3.15     16.85   16%    21452  3927394     1% /export

2017-05-26 07:39:50: Check checkdf.ksh completed successfully: returncode 0
2017-05-26 07:39:50: Runtime: 1 second(s)
2017-05-26 07:39:50: 11% complete - 198 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:50: Running check script 27 of 224: checkdfsummary.ksh

Description:
------------

Displays a summary of file system space allocated, used and available in gigabytes.

The check script uses the following command to determine the necessary information:

# df -Pk

Output:
------------

 Allocated (GB)       Used (GB)  Available (GB)       Used (%s)
         396427           51517          344909            13.0

2017-05-26 07:39:50: Check checkdfsummary.ksh completed successfully: returncode 0
2017-05-26 07:39:50: Runtime: 0 second(s)
2017-05-26 07:39:50: 12% complete - 197 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:50: Running check script 28 of 224: checkdisks.ksh

Description:
------------

This check script lists all the disks on the system.

The following command is run by this check script:

# /usr/sbin/lsdev -Cc disk

Output:
------------

List disks on the system: lsdev -Cc disk

hdisk0  Available 03-00-00 SAS 4K Disk Drive
hdisk1  Available 09-00-00 SAS 4K Disk Drive
hdisk2  Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk3  Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk4  Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk5  Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk6  Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk7  Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk8  Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk9  Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk10 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk11 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk12 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk13 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk14 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk15 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk16 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk17 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk18 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk19 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk20 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk21 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk22 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk23 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk24 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk25 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk26 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk27 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk28 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk29 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk30 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk31 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk32 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk33 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk34 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk35 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk36 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk37 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk38 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk39 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk40 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk41 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk42 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk43 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk44 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk45 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk46 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive
hdisk47 Available 00-00-01 MPIO Compellent Fibre Channel Disk Drive

List the physical location of all disks: lsdev -Cc disk -F "name status physloc"

hdisk0  Available U78C9.001.WZS0TLH-P2-D7
hdisk1  Available U78C9.001.WZS0TLH-P2-D1
hdisk2  Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L20000000000000
hdisk3  Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L10000000000000
hdisk4  Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L22000000000000
hdisk5  Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L12000000000000
hdisk6  Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2000000000000
hdisk7  Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L24000000000000
hdisk8  Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L14000000000000
hdisk9  Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L4000000000000
hdisk10 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L26000000000000
hdisk11 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L16000000000000
hdisk12 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L6000000000000
hdisk13 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L28000000000000
hdisk14 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L18000000000000
hdisk15 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L8000000000000
hdisk16 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2A000000000000
hdisk17 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1A000000000000
hdisk18 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LA000000000000
hdisk19 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2C000000000000
hdisk20 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1C000000000000
hdisk21 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LC000000000000
hdisk22 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1E000000000000
hdisk23 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LE000000000000
hdisk24 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L21000000000000
hdisk25 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L11000000000000
hdisk26 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1000000000000
hdisk27 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L23000000000000
hdisk28 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L13000000000000
hdisk29 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L3000000000000
hdisk30 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L25000000000000
hdisk31 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L15000000000000
hdisk32 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L5000000000000
hdisk33 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L27000000000000
hdisk34 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L17000000000000
hdisk35 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L7000000000000
hdisk36 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L29000000000000
hdisk37 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L19000000000000
hdisk38 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L9000000000000
hdisk39 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2B000000000000
hdisk40 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1B000000000000
hdisk41 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LB000000000000
hdisk42 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2D000000000000
hdisk43 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1D000000000000
hdisk44 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LD000000000000
hdisk45 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1F000000000000
hdisk46 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LF000000000000
hdisk47 Available U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2E000000000000

2017-05-26 07:39:50: Check checkdisks.ksh completed successfully: returncode 0
2017-05-26 07:39:50: Runtime: 0 second(s)
2017-05-26 07:39:50: 12% complete - 196 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:50: Running check script 29 of 224: checkdst.ksh

Description:
------------

Displays when time changes will occur this year due to daylight saving time (DST).

Note that some time zones may not have DST, in which case this script will show no output.

Output:
------------

Sun Mar 12 01:59:59 PST 2017 --> Sun Mar 12 03:00:00 PDT 2017
Sun Nov 05 01:59:59 PDT 2017 --> Sun Nov 05 01:00:00 PST 2017

2017-05-26 07:39:50: Check checkdst.ksh completed successfully: returncode 0
2017-05-26 07:39:50: Runtime: 0 second(s)
2017-05-26 07:39:50: 12% complete - 195 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:50: Running check script 30 of 224: checkdumpctrl.ksh

Description:
------------

Displays the output of the dumpctrl command (AIX 6 and up).

The following command is run by this check script:

# /usr/sbin/dumpctrl -ql

By default, the livedump location is /var/adm/ras/livedump.

Output:
------------

Live Dump Enabled:			yes
Live Dump Directory:			/var/adm/ras/livedump
Live Dump Free Space Threshold:		25%
Live Dump Global Level:			3
Live Dump Heap Size:			0 MB (0 indicates default heap size)
Live Dump Duplicate Suppression Type:	all
Live Dump Max System Freeze Interval:	100ms

2017-05-26 07:39:51: Check checkdumpctrl.ksh completed successfully: returncode 0
2017-05-26 07:39:51: Runtime: 0 second(s)
2017-05-26 07:39:51: 13% complete - 194 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:51: Running check script 31 of 224: checkemcavamarrmanlevel.ksh

Description:
------------

Check the level installed of EMC Avamar RMAN client.

Output:
------------

EMC Avamar RMAN client not installed.

2017-05-26 07:39:51: Check checkemcavamarrmanlevel.ksh completed successfully: returncode 0
2017-05-26 07:39:51: Runtime: 0 second(s)
2017-05-26 07:39:51: 13% complete - 193 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:51: Running check script 32 of 224: checkemcinq.ksh

Description:
------------

Run the inq utility of EMC, if present on the system.

This utility helps to identify LUN information on EMC provided devices.

2017-05-26 07:39:51: Check checkemcinq.ksh completed successfully: returncode 0
2017-05-26 07:39:51: Runtime: 0 second(s)
2017-05-26 07:39:51: 14% complete - 192 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:51: Running check script 33 of 224: checkemcnetworkerlevel.ksh

Description:
------------

Displays the level installed of EMC Networker.

This check script will run the following command:

# /usr/bin/lslpp -l LGTOnw.clnt.rte

Output:
------------

EMC Networker client not installed.

2017-05-26 07:39:51: Check checkemcnetworkerlevel.ksh completed successfully: returncode 0
2017-05-26 07:39:51: Runtime: 0 second(s)
2017-05-26 07:39:51: 14% complete - 191 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:51: Running check script 34 of 224: checkemcpowermt.ksh

Description:
------------

Run powermt if possible.

The powermt command is part of EMC's PowerPath software, and thus is only relevant when using EMC San 
storage.

2017-05-26 07:39:51: Check checkemcpowermt.ksh completed successfully: returncode 0
2017-05-26 07:39:51: Runtime: 0 second(s)
2017-05-26 07:39:51: 15% complete - 190 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:51: Running check script 35 of 224: checkemcselicense.ksh

Description:
------------

Check the EMC Solution Enabler license keys, if this is installed on the server.

2017-05-26 07:39:51: Check checkemcselicense.ksh completed successfully: returncode 0
2017-05-26 07:39:51: Runtime: 0 second(s)
2017-05-26 07:39:51: 15% complete - 189 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:51: Running check script 36 of 224: checkentcap.ksh

Description:
------------

Check the entitled capacity.

Output:
------------

min_capacity ent_capacity max_capacity inc_capacity   capped weight      type
        1.00        24.00        24.00         1.00   Capped      0Dedicated-8

2017-05-26 07:39:52: Check checkentcap.ksh completed successfully: returncode 0
2017-05-26 07:39:52: Runtime: 1 second(s)
2017-05-26 07:39:52: 16% complete - 188 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:52: Running check script 37 of 224: checkenv.ksh

Description:
------------

Shows the shell environment, by running:

# env

This will display all the shell environment variables defined on the system.

Output:
------------

_=/usr/bin/env
mytime=07:39:41 PDT
LANG=en_US
LOGIN=root
STARTTIME=1495809581
errorsonly=false
MY_HOST_NAME=tsm0001
CLCMD_PASSTHRU=1
PATH=/usr/bin:/etc:/usr/sbin:/usr/ucb:/usr/bin/X11:/sbin:/usr/java6/jre/bin:/usr/java6/bin:/usr/es/sbin/
cluster:/usr/es/sbin/cluster/utilities
OKNR=36
EXTENDED_HISTORY=ON
LC__FASTMSG=true
HISTFILE=//.history.root/.sh_history.root.root.172.22.0.250.pts-0.0629.052617
LogFile=checkall_tsm0001.log
logfileon=true
file=checkenv.ksh
LOGNAME=root
mins=0
TOTALNR=37
WARNNR=0
excludechecks=false
MAIL=/usr/spool/mail/root
LOCPATH=/usr/lib/nls/loc
csvon=false
USER=root
ERRORNR=0
AUTHSTATE=files
htmlon=false
mydate=05/26/2017
basic=false
SHELL=/usr/bin/ksh
ODMDIR=/etc/objrepos
CLUSTER_OVERRIDE=yes
TMOUT=3600
xmlon=false
HOME=/
TERM=xterm
MAILMSG=[YOU HAVE NEW MAIL]
email100=false
categoryList=inventory
verboseon=true
PWD=/uhc
suppressok=false
mywidth=104
TZ=America/Los_Angeles
myoutput=checkall_tsm0001
writedesc=true
mychar=-
A__z=! LOGNAME=*TMOUT
NLSPATH=/usr/lib/nls/msg/%L/%N:/usr/lib/nls/msg/%L/%N.cat:/usr/lib/nls/msg/%l.%c/%N:/usr/lib/nls/msg/%l.
%c/%N.cat

2017-05-26 07:39:52: Check checkenv.ksh completed successfully: returncode 0
2017-05-26 07:39:52: Runtime: 0 second(s)
2017-05-26 07:39:52: 16% complete - 187 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:52: Running check script 38 of 224: checkenvironment.ksh

Description:
------------

Displays the contents of /etc/environment.

This check script will not display any empty lines or comments (lines that start with a hash mark).

Output:
------------

PATH=/usr/bin:/etc:/usr/sbin:/usr/ucb:/usr/bin/X11:/sbin:/usr/java6/jre/bin:/usr/java6/bin:/usr/es/sbin/
cluster:/usr/es/sbin/cluster/utilities
TZ=America/Los_Angeles
LANG=en_US
LOCPATH=/usr/lib/nls/loc
NLSPATH=/usr/lib/nls/msg/%L/%N:/usr/lib/nls/msg/%L/%N.cat:/usr/lib/nls/msg/%l.%c/%N:/usr/lib/nls/msg/%l.
%c/%N.cat
LC__FASTMSG=true
ODMDIR=/etc/objrepos
CLCMD_PASSTHRU=1
CLUSTER_OVERRIDE=yes
EXTENDED_HISTORY=ON

2017-05-26 07:39:52: Check checkenvironment.ksh completed successfully: returncode 0
2017-05-26 07:39:52: Runtime: 0 second(s)
2017-05-26 07:39:52: 16% complete - 186 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:52: Running check script 39 of 224: checketchostsallow.ksh

Description:
------------

Displays the contents of /etc/hosts.allow.

The /etc/hosts.allow file is a file that explicitly allows specific hosts or networks access to the 
system. It is part of the TCP wrappers package, which can be found on the AIX Expansion Pack ISO/DVD, 
and can be installed by installing the netsec.options filesets.

2017-05-26 07:39:52: Check checketchostsallow.ksh completed successfully: returncode 0
2017-05-26 07:39:52: Runtime: 0 second(s)
2017-05-26 07:39:52: 17% complete - 185 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:52: Running check script 40 of 224: checketchostsdeny.ksh

Description:
------------

Displays the contents of /etc/hosts.deny.

The /etc/hosts.deny file is a file that explicitly denies specific hosts or networks access to the 
system. It is part of the TCP wrappers package, which can be found on the AIX Expansion Pack ISO/DVD, 
and can be installed by installing the netsec.options filesets.

2017-05-26 07:39:52: Check checketchostsdeny.ksh completed successfully: returncode 0
2017-05-26 07:39:52: Runtime: 0 second(s)
2017-05-26 07:39:52: 17% complete - 184 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:52: Running check script 41 of 224: checketchostsfile.ksh

Description:
------------

Displays the contents of /etc/hosts.

This check script will not display any empty lines or any lines that are commented out (start with a 
hash mark).

Output:
------------

127.0.0.1		loopback localhost	# loopback (lo0) name/address
192.18.42.43 tsm0001
192.18.42.44 tsm0002 
192.18.42.45 tsm0000

2017-05-26 07:39:52: Check checketchostsfile.ksh completed successfully: returncode 0
2017-05-26 07:39:52: Runtime: 0 second(s)
2017-05-26 07:39:52: 18% complete - 183 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:52: Running check script 42 of 224: checketcirsconf.ksh

Description:
------------

Display the contents of file /etc/irs.conf.

File /etc/irs.conf is used to control the order of mechanisms that the resolver libraries use. For 
detailed information, check 
http://www.ibm.com/support/knowledgecenter/ssw_aix_61/com.ibm.aix.files/irs.conf.htm.

We recommend using DNS for resolving host names, and thus we recommend the use of /etc/resolv.conf 
instead of using /etc/irs.conf. Also, we recommend that the environment variable $NSORDER is not set on 
the system, allowing file /etc/resolv.conf to determine the resolve order.

2017-05-26 07:39:53: Check checketcirsconf.ksh completed successfully: returncode 0
2017-05-26 07:39:53: Runtime: 0 second(s)
2017-05-26 07:39:53: 18% complete - 182 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:53: Running check script 43 of 224: checketcrcshutdown.ksh

Description:
------------

Displays any content of the /etc/rc.shutdown script.

Please validate that the contents of /etc/rc.shutdown is correct. If it's not, it may prevent the 
system from shutting down properly.

This check script will not display any empty lines, or any lines that are commented out (start with a 
hash mark).

Output:
------------

   if [[ -f /opt/rsct/bin/ct_node_runstate ]]
   then
        /opt/rsct/bin/ct_node_runstate -w SHUTDOWN
   fi
/usr/lpp/DellSC_MPAIX/rc_boot_check

2017-05-26 07:39:53: Check checketcrcshutdown.ksh completed successfully: returncode 0
2017-05-26 07:39:53: Runtime: 0 second(s)
2017-05-26 07:39:53: 19% complete - 181 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:53: Running check script 44 of 224: checketcrsyslogconf.ksh

Description:
------------

Displays the contents of /etc/rsyslog.conf.

This check script will not display any empty lines, or any lines that are commented out (start with a 
hash mark).

Review the output of this check script, to ensure that the correct entries are present in 
/etc/rsyslog.conf, so the rsyslog daemon is indeed logging information. As an alternative, you can also 
use syslog-ng or syslog. 

The syslog service is installed by default on AIX. You can download and install a rsyslog RPM through 
the AIX Toolbox for Linux Applications.

2017-05-26 07:39:53: Check checketcrsyslogconf.ksh completed successfully: returncode 0
2017-05-26 07:39:53: Runtime: 0 second(s)
2017-05-26 07:39:53: 19% complete - 180 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:53: Running check script 45 of 224: checketcsyslogconf.ksh

Description:
------------

Displays the contents of /etc/syslog.conf.

This check script will not display any empty lines, or any lines that are commented out (start with a 
hash mark).

Review the output of this check script, to ensure that the correct entries are present in 
/etc/syslog.conf, so the syslog daemon is indeed logging information. As an alternative, you can also 
use syslog-ng or rsyslog.

Output:
------------

aso.notice /var/log/aso/aso.log rotate size 1m files 8 compress
aso.info /var/log/aso/aso_process.log rotate size 1m files 8 compress
aso.debug /var/log/aso/aso_debug.log rotate size 32m files 8 compress
caa.debug /var/adm/ras/syslog.caa rotate size 10m files 10 compress
local0.crit /dev/console
local0.info;user.notice;daemon.notice /var/hacmp/adm/cluster.log rotate size 1m files 8
local1.debug /var/log/sshd.messages rotate time 1d files 10 compress

2017-05-26 07:39:53: Check checketcsyslogconf.ksh completed successfully: returncode 0
2017-05-26 07:39:53: Runtime: 0 second(s)
2017-05-26 07:39:53: 20% complete - 179 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:53: Running check script 46 of 224: checketherchannel.ksh

Description:
------------

Lists the EtherChannels configured on the system.

Output:
------------

ent8

adapter_names   ent0,ent1,ent4,ent5 EtherChannel Adapters                           True
alt_addr        0x000000000000      Alternate EtherChannel Address                  True
auto_recovery   yes                 Enable automatic recovery after failover        True
backup_adapter  NONE                Adapter used when whole channel fails           True
hash_mode       default             Determines how outgoing adapter is chosen       True
interval        long                Determines interval value for IEEE 802.3ad mode True
mode            standard            EtherChannel mode of operation                  True
netaddr         0                   Address to ping                                 True
noloss_failover yes                 Enable lossless failover after ping failure     True
num_retries     3                   Times to retry ping before failing              True
retry_time      1                   Wait time (in seconds) between pings            True
use_alt_addr    no                  Enable Alternate EtherChannel Address           True
use_jumbo_frame no                  Enable Gigabit Ethernet Jumbo Frames            True

2017-05-26 07:39:53: Check checketherchannel.ksh completed successfully: returncode 0
2017-05-26 07:39:53: Runtime: 0 second(s)
2017-05-26 07:39:53: 20% complete - 178 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:53: Running check script 47 of 224: checketherchanneltree.ksh

Description:
------------

Displays the EtherChannel tree.

This check script will show how any EtherChannels are configured on this system.

Output:
------------

ent8 - EtherChannel device
    ent0             U78C9.001.WZS0TLH-P1-C6-T1  PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
    ent1             U78C9.001.WZS0TLH-P1-C6-T2  PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
    ent4             U78C9.001.WZS0TLH-P1-C10-T1  PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
    ent5             U78C9.001.WZS0TLH-P1-C10-T2  PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)

2017-05-26 07:39:53: Check checketherchanneltree.ksh completed successfully: returncode 0
2017-05-26 07:39:53: Runtime: 0 second(s)
2017-05-26 07:39:53: 20% complete - 177 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:53: Running check script 48 of 224: checkexpectrpm.ksh

Description:
------------

Check if the Expect RPM is installed, and if so, what version. It is not necessary to have expect 
installed, but it can be useful.

Expect is a tool that can be used to automate interactive applications. The RPM for Expect can be 
downloaded from:

http://www.perzl.org/aix/index.php?n=Main.Expect

The home page for Expect is:

http://www.nist.gov/el/msid/expect.cfm

Output:
------------

expect-5.42.1-3

2017-05-26 07:39:54: Check checkexpectrpm.ksh completed successfully: returncode 0
2017-05-26 07:39:54: Runtime: 1 second(s)
2017-05-26 07:39:54: 21% complete - 176 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:54: Running check script 49 of 224: checkfastt.ksh

Description:
------------

Check the Fast-T configuration.

Obviously, this script will only show any output, if a Fast-T storage array is connected to this AIX 
system.

The following command is run by this check script:

# /usr/bin/fget_config -vA

2017-05-26 07:39:54: Check checkfastt.ksh completed successfully: returncode 0
2017-05-26 07:39:54: Runtime: 0 second(s)
2017-05-26 07:39:54: 21% complete - 175 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:54: Running check script 50 of 224: checkfcsnetworkaddress.ksh

Description:
------------

A simple inventory of the Network Address of the Fibre Channel adapters.

Output:
------------

fcs0 10000088ADF49803
fcs1 10000088ADF49804
fcs2 10000088ADF497D0
fcs3 10000088ADF497D1

2017-05-26 07:39:54: Check checkfcsnetworkaddress.ksh completed successfully: returncode 0
2017-05-26 07:39:54: Runtime: 0 second(s)
2017-05-26 07:39:54: 22% complete - 174 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:54: Running check script 51 of 224: checkfcstat.ksh

Description:
------------

Check the statistics of the Fibre Channel Adapters by running fcstat.

This script will report an error if a device can't be opened. An error code of 46 means that there is 
no link on the Fibre Channel Adapter.

You can resolve such an error, by either making sure a cable is plugged into the port of the fibre 
channel adapter, or by plugging in a proper loop-back plug (not just the rubbery plug, but a real 
loop-back plug).

Output:
------------

Command: /usr/bin/fcstat -e fcs0
---------------------------------

FIBRE CHANNEL STATISTICS REPORT: fcs0
Device Type: PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103) (adapter/pciex/df1000e21410f10)
ZA: 10.2.252.1919
World Wide Node Name: 0x20000088ADF49803
World Wide Port Name: 0x10000088ADF49803
FC-4 TYPES:
Supported: 0x0000010000000000000000000000000000000000000000000000000000000000
Active:    0x0000010000000000000000000000000000000000000000000000000000000000
FC-4 TYPES (ULP mappings):
Supported ULPs:
Small Computer System Interface (SCSI) Fibre Channel Protocol (FCP)
Active ULPs:
Small Computer System Interface (SCSI) Fibre Channel Protocol (FCP)
Class of Service: 3
Port Speed (supported): 16 GBIT
Port Speed (running):   16 GBIT
Port FC ID: 0x011180
Port Type: Fabric
Attention Type:   Link Up
Topology:  Point to Point or Fabric

Command: /usr/bin/fcstat -e fcs1
---------------------------------

FIBRE CHANNEL STATISTICS REPORT: fcs1
Device Type: PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103) (adapter/pciex/df1000e21410f10)
ZA: 10.2.252.1919
World Wide Node Name: 0x20000088ADF49804
World Wide Port Name: 0x10000088ADF49804
FC-4 TYPES:
Supported: 0x0000010000000000000000000000000000000000000000000000000000000000
Active:    0x0000010000000000000000000000000000000000000000000000000000000000
FC-4 TYPES (ULP mappings):
Supported ULPs:
Small Computer System Interface (SCSI) Fibre Channel Protocol (FCP)
Active ULPs:
Small Computer System Interface (SCSI) Fibre Channel Protocol (FCP)
Class of Service: 3
Port Speed (supported): 16 GBIT
Port Speed (running):   16 GBIT
Port FC ID: 0x011180
Port Type: Fabric
Attention Type:   Link Up
Topology:  Point to Point or Fabric

Command: /usr/bin/fcstat -e fcs2
---------------------------------

FIBRE CHANNEL STATISTICS REPORT: fcs2
Device Type: PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103) (adapter/pciex/df1000e21410f10)
ZA: 10.2.252.1919
World Wide Node Name: 0x20000088ADF497D0
World Wide Port Name: 0x10000088ADF497D0
FC-4 TYPES:
Supported: 0x0000010000000000000000000000000000000000000000000000000000000000
Active:    0x0000010000000000000000000000000000000000000000000000000000000000
FC-4 TYPES (ULP mappings):
Supported ULPs:
Small Computer System Interface (SCSI) Fibre Channel Protocol (FCP)
Active ULPs:
Small Computer System Interface (SCSI) Fibre Channel Protocol (FCP)
Class of Service: 3
Port Speed (supported): 16 GBIT
Port Speed (running):   16 GBIT
Port FC ID: 0x011080
Port Type: Fabric
Attention Type:   Link Up
Topology:  Point to Point or Fabric

Command: /usr/bin/fcstat -e fcs3
---------------------------------

FIBRE CHANNEL STATISTICS REPORT: fcs3
Device Type: PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103) (adapter/pciex/df1000e21410f10)
ZA: 10.2.252.1919
World Wide Node Name: 0x20000088ADF497D1
World Wide Port Name: 0x10000088ADF497D1
FC-4 TYPES:
Supported: 0x0000010000000000000000000000000000000000000000000000000000000000
Active:    0x0000010000000000000000000000000000000000000000000000000000000000
FC-4 TYPES (ULP mappings):
Supported ULPs:
Small Computer System Interface (SCSI) Fibre Channel Protocol (FCP)
Active ULPs:
Small Computer System Interface (SCSI) Fibre Channel Protocol (FCP)
Class of Service: 3
Port Speed (supported): 16 GBIT
Port Speed (running):   16 GBIT
Port FC ID: 0x011080
Port Type: Fabric
Attention Type:   Link Up
Topology:  Point to Point or Fabric

2017-05-26 07:39:55: Check checkfcstat.ksh completed successfully: returncode 0
2017-05-26 07:39:55: Runtime: 1 second(s)
2017-05-26 07:39:55: 22% complete - 173 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:55: Running check script 52 of 224: checkfilesystems.ksh

Description:
------------

Shows the output of /etc/filesystems and the lsfs command.

It will generate an error if a file system can't be found in /etc/filesystems.

Output:
------------

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd4        --         /                      jfs2  4194304 --         yes  no 
  (lv size: 524288, fs size: 4194304, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)

/:
	dev		= /dev/hd4
	vfs		= jfs2
	log		= /dev/hd8
	mount		= automatic
	check		= false
	type		= bootfs
	vol		= root
	free		= true

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd1        --         /home                  jfs2  20971520 --         yes  no 
  (lv size: 2621440, fs size: 20971520, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)

/home:
	dev		= /dev/hd1
	vfs		= jfs2
	log		= /dev/hd8
	mount		= true
	check		= true
	vol		= /home
	free		= false

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd2        --         /usr                   jfs2  27262976 --         yes  no 
  (lv size: 3407872, fs size: 27262976, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)

/usr:
	dev		= /dev/hd2
	vfs		= jfs2
	log		= /dev/hd8
	mount		= automatic
	check		= false
	type		= bootfs
	vol		= /usr
	free		= false

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd9var     --         /var                   jfs2  20971520 --         yes  no 
  (lv size: 2621440, fs size: 20971520, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)

/var:
	dev		= /dev/hd9var
	vfs		= jfs2
	log		= /dev/hd8
	mount		= automatic
	check		= false
	type		= bootfs
	vol		= /var
	free		= false

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd3        --         /tmp                   jfs2  20971520 --         yes  no 
  (lv size: 2621440, fs size: 20971520, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)

/tmp:
	dev		= /dev/hd3
	vfs		= jfs2
	log		= /dev/hd8
	mount		= automatic
	check		= false
	vol		= /tmp
	free		= false

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd11admin  --         /admin                 jfs2  2097152 --         yes  no 
  (lv size: 262144, fs size: 2097152, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)

/admin:
	dev       = /dev/hd11admin
	vol       = /admin
	mount     = true
	check     = false
	free      = false
	vfs       = jfs2
	log       = /dev/hd8

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/proc           --         /proc                  procfs --      --         yes  no 

/proc:
	dev	  = /proc
	vol	  = /proc
	mount	  = true
	check	  = false
	free	  = false
	vfs	  = procfs

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd10opt    --         /opt                   jfs2  20971520 --         yes  no 
  (lv size: 2621440, fs size: 20971520, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)

/opt:
	dev		= /dev/hd10opt
	vfs		= jfs2
	log		= /dev/hd8
	mount		= true
	check		= true
	vol		= /opt
	free		= false

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/livedump   --         /var/adm/ras/livedump  jfs2  2097152 --         yes  no 
  (lv size: 262144, fs size: 2097152, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)

/var/adm/ras/livedump:
	dev		= /dev/livedump
	vfs		= jfs2
	log		= /dev/hd8
	mount		= true
	account		= false

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/mksysblv   --         /mksysb                jfs2  209715200 noatime,rw yes  no 
  (lv size: 26214400, fs size: 209715200, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 400, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: no)

/mksysb:
	dev		= /dev/mksysblv
	vfs		= jfs2
	log		= INLINE
	mount		= true
	options		= noatime,rw
	account		= false

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmhomelv  --         /tsmhome               jfs2  104595456 rbrw,noatime,rw no   no 
  (lv size: 104595456, fs size: 104595456, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 200, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmhome:
	dev		= /dev/tsmhomelv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs01lv  --         /tsmfs01/tsmfs01       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs01:
	dev		= /dev/tsmfs01lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs02lv  --         /tsmfs01/tsmfs02       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs02:
	dev		= /dev/tsmfs02lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmactloglv --         /tsmactlog             jfs2  628097024 rbrw,noatime,rw no   no 
  (lv size: 628097024, fs size: 628097024, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmactlog:
	dev		= /dev/tsmactloglv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs03lv  --         /tsmfs01/tsmfs03       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs03:
	dev		= /dev/tsmfs03lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmarchloglv --         /tsmarchlog            jfs2  4286578688 rbrw,noatime,rw no   no 
  (lv size: 4286578688, fs size: 4286578688, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2044, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmarchlog:
	dev		= /dev/tsmarchloglv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmarchlog2lv --         /tsmarchlog2           jfs2  4286578688 rbrw,noatime,rw no   no 
  (lv size: 4286578688, fs size: 4286578688, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2044, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmarchlog2:
	dev		= /dev/tsmarchlog2lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs04lv  --         /tsmfs01/tsmfs04       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs04:
	dev		= /dev/tsmfs04lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs05lv  --         /tsmfs01/tsmfs05       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs05:
	dev		= /dev/tsmfs05lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdbbkp01lv --         /tsmdbbkp/tsmdbbkp01   jfs2  15015608320 rbrw,noatime,rw no   no 
  (lv size: 15015608320, fs size: 15015608320, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdbbkp/tsmdbbkp01:
	dev		= /dev/tsmdbbkp01lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs06lv  --         /tsmfs01/tsmfs06       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs06:
	dev		= /dev/tsmfs06lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdbbkp02lv --         /tsmdbbkp/tsmdbbkp02   jfs2  15015608320 rbrw,noatime,rw no   no 
  (lv size: 15015608320, fs size: 15015608320, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdbbkp/tsmdbbkp02:
	dev		= /dev/tsmdbbkp02lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb01lv  --         /tsmdb/tsmdb01         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb01:
	dev		= /dev/tsmdb01lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdbbkp03lv --         /tsmdbbkp/tsmdbbkp03   jfs2  15015608320 rbrw,noatime,rw no   no 
  (lv size: 15015608320, fs size: 15015608320, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdbbkp/tsmdbbkp03:
	dev		= /dev/tsmdbbkp03lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs07lv  --         /tsmfs01/tsmfs07       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs07:
	dev		= /dev/tsmfs07lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdbbkp04lv --         /tsmdbbkp/tsmdbbkp04   jfs2  15015608320 rbrw,noatime,rw no   no 
  (lv size: 15015608320, fs size: 15015608320, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdbbkp/tsmdbbkp04:
	dev		= /dev/tsmdbbkp04lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb02lv  --         /tsmdb/tsmdb02         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb02:
	dev		= /dev/tsmdb02lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs08lv  --         /tsmfs01/tsmfs08       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs08:
	dev		= /dev/tsmfs08lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb03lv  --         /tsmdb/tsmdb03         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb03:
	dev		= /dev/tsmdb03lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs09lv  --         /tsmfs01/tsmfs09       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs09:
	dev		= /dev/tsmfs09lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmrecoverylv --         /tsmrecovery           jfs2  837812224 rbrw,noatime,rw no   no 
  (lv size: 837812224, fs size: 837812224, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmrecovery:
	dev		= /dev/tsmrecoverylv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmappslv  --         /tsmapps               jfs2  61865984 rbrw,noatime,rw no   no 
  (lv size: 61865984, fs size: 61865984, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 118, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmapps:
	dev		= /dev/tsmappslv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb04lv  --         /tsmdb/tsmdb04         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb04:
	dev		= /dev/tsmdb04lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs10lv  --         /tsmfs01/tsmfs10       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs10:
	dev		= /dev/tsmfs10lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb05lv  --         /tsmdb/tsmdb05         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb05:
	dev		= /dev/tsmdb05lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs11lv  --         /tsmfs01/tsmfs11       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs01/tsmfs11:
	dev		= /dev/tsmfs11lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb06lv  --         /tsmdb/tsmdb06         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb06:
	dev		= /dev/tsmdb06lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb07lv  --         /tsmdb/tsmdb07         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb07:
	dev		= /dev/tsmdb07lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs12lv  --         /tsmfs02/tsmfs12       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs12:
	dev		= /dev/tsmfs12lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb08lv  --         /tsmdb/tsmdb08         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb08:
	dev		= /dev/tsmdb08lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs13lv  --         /tsmfs02/tsmfs13       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs13:
	dev		= /dev/tsmfs13lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb09lv  --         /tsmdb/tsmdb09         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb09:
	dev		= /dev/tsmdb09lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs14lv  --         /tsmfs02/tsmfs14       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs14:
	dev		= /dev/tsmfs14lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb10lv  --         /tsmdb/tsmdb10         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb10:
	dev		= /dev/tsmdb10lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs15lv  --         /tsmfs02/tsmfs15       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs15:
	dev		= /dev/tsmfs15lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb11lv  --         /tsmdb/tsmdb11         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb11:
	dev		= /dev/tsmdb11lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs16lv  --         /tsmfs02/tsmfs16       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs16:
	dev		= /dev/tsmfs16lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmdb12lv  --         /tsmdb/tsmdb12         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmdb/tsmdb12:
	dev		= /dev/tsmdb12lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs17lv  --         /tsmfs02/tsmfs17       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs17:
	dev		= /dev/tsmfs17lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs18lv  --         /tsmfs02/tsmfs18       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs18:
	dev		= /dev/tsmfs18lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs19lv  --         /tsmfs02/tsmfs19       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs19:
	dev		= /dev/tsmfs19lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs20lv  --         /tsmfs02/tsmfs20       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs20:
	dev		= /dev/tsmfs20lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs21lv  --         /tsmfs02/tsmfs21       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs21:
	dev		= /dev/tsmfs21lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/tsmfs22lv  --         /tsmfs02/tsmfs22       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)

/tsmfs02/tsmfs22:
	dev		= /dev/tsmfs22lv
	vfs		= jfs2
	log		= INLINE
	mount		= false
	check		= false
	type		= tsm
	options		= rbrw,noatime,rw
	account		= false
	mountguard	= yes

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/exportlv   --         /export                jfs2  41943040 rw,noatime yes  no 
  (lv size: 5242880, fs size: 41943040, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 80, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: no)

/export:
	dev		= /dev/exportlv
	vfs		= jfs2
	log		= INLINE
	mount		= true
	options		= rw,noatime
	account		= false


2017-05-26 07:39:56: Check checkfilesystems.ksh completed successfully: returncode 0
2017-05-26 07:39:56: Runtime: 1 second(s)
2017-05-26 07:39:56: 23% complete - 172 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:56: Running check script 53 of 224: checkfipsmode.ksh

Description:
------------

Check if the cryptographic operational mode has been enabled.

Federal Information Processing Standards (FIPS) are standards and guidelines issued by the National 
Institute of Standards and Technology (NIST) for US federal government computer systems. FIPS are 
developed when there are compelling federal government requirements for standards, such as for security 
and interoperability, but acceptable industry standards or solutions do not exist. Government agencies 
and financial institutions use these standards to ensure that the products conform to specified 
security requirements. For more information on these standards, see the National Institute of Standards 
and Technology Web site, at this link: http://csrc.nist.gov/publications/fips/. 

The United States government defines many (several hundred) "Federal Information Processing Standard" 
(FIPS) documents. FIPS documents define rules, regulations, and standards for many aspects of handling 
of information by computers and by people.  They apply to all US government employees and personnel, 
including soldiers in the armed forces. Generally speaking, any use of a computer by US government 
personnel must conform to all the relevant FIPS regulations.  If you're a US government worker, and you 
want to use AIX, you will want to use it in a way that is fully conforming with all the relevant FIPS 
regulations. One of the FIPS regulations, FIPS 140, governs the use of encryption and cryptographic 
services.  It requires that ALL cryptography done by US government personnel MUST be done in "devices" 
that have been independently tested, and certified by NIST, to meet the extensive requirements of that 
document. So, in order for AIX to be usable by people who are subject to the FIPS regulations, AIX 
cryptographic software must be able to operate in a mode that is fully compliant with FIPS 140. To that 
end, AIX offers a "FIPS Mode".

It's possible to enable Cryptographic Operational Mode on AIX, by running:

# /usr/sbin/clic_fipsmode -enable

By default, this is disabled on AIX, showing that the NON_FIPS mode has been enabled. By enabling FIPS, 
you can change this setting in the ODM database. You can change this mode setting at any time, and it 
only takes effect into kernel when the system is rebooted.

Output:
------------

NON_FIPS mode has been enabled.

2017-05-26 07:39:56: Check checkfipsmode.ksh completed successfully: returncode 0
2017-05-26 07:39:56: Runtime: 0 second(s)
2017-05-26 07:39:56: 23% complete - 171 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:56: Running check script 54 of 224: checkfsperms.ksh

Description:
------------

Displays the file system permissions.

This check script uses the lsfs command to display the file systems, and will then run ls -ld for each 
file system to display the file system permissions.

Output:
------------

Known file systems (lsfs):

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd4        --         /                      jfs2  4194304 --         yes  no 
/dev/hd1        --         /home                  jfs2  20971520 --         yes  no 
/dev/hd2        --         /usr                   jfs2  27262976 --         yes  no 
/dev/hd9var     --         /var                   jfs2  20971520 --         yes  no 
/dev/hd3        --         /tmp                   jfs2  20971520 --         yes  no 
/dev/hd11admin  --         /admin                 jfs2  2097152 --         yes  no 
/proc           --         /proc                  procfs --      --         yes  no 
/dev/hd10opt    --         /opt                   jfs2  20971520 --         yes  no 
/dev/livedump   --         /var/adm/ras/livedump  jfs2  2097152 --         yes  no 
/dev/mksysblv   --         /mksysb                jfs2  209715200 noatime,rw yes  no 
/dev/tsmhomelv  --         /tsmhome               jfs2  104595456 rbrw,noatime,rw no   no 
/dev/tsmfs01lv  --         /tsmfs01/tsmfs01       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmfs02lv  --         /tsmfs01/tsmfs02       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmactloglv --         /tsmactlog             jfs2  628097024 rbrw,noatime,rw no   no 
/dev/tsmfs03lv  --         /tsmfs01/tsmfs03       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmarchloglv --         /tsmarchlog            jfs2  4286578688 rbrw,noatime,rw no   no 
/dev/tsmarchlog2lv --         /tsmarchlog2           jfs2  4286578688 rbrw,noatime,rw no   no 
/dev/tsmfs04lv  --         /tsmfs01/tsmfs04       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmfs05lv  --         /tsmfs01/tsmfs05       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdbbkp01lv --         /tsmdbbkp/tsmdbbkp01   jfs2  15015608320 rbrw,noatime,rw no   no 
/dev/tsmfs06lv  --         /tsmfs01/tsmfs06       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdbbkp02lv --         /tsmdbbkp/tsmdbbkp02   jfs2  15015608320 rbrw,noatime,rw no   no 
/dev/tsmdb01lv  --         /tsmdb/tsmdb01         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmdbbkp03lv --         /tsmdbbkp/tsmdbbkp03   jfs2  15015608320 rbrw,noatime,rw no   no 
/dev/tsmfs07lv  --         /tsmfs01/tsmfs07       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdbbkp04lv --         /tsmdbbkp/tsmdbbkp04   jfs2  15015608320 rbrw,noatime,rw no   no 
/dev/tsmdb02lv  --         /tsmdb/tsmdb02         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs08lv  --         /tsmfs01/tsmfs08       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdb03lv  --         /tsmdb/tsmdb03         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs09lv  --         /tsmfs01/tsmfs09       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmrecoverylv --         /tsmrecovery           jfs2  837812224 rbrw,noatime,rw no   no 
/dev/tsmappslv  --         /tsmapps               jfs2  61865984 rbrw,noatime,rw no   no 
/dev/tsmdb04lv  --         /tsmdb/tsmdb04         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs10lv  --         /tsmfs01/tsmfs10       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdb05lv  --         /tsmdb/tsmdb05         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs11lv  --         /tsmfs01/tsmfs11       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdb06lv  --         /tsmdb/tsmdb06         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmdb07lv  --         /tsmdb/tsmdb07         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs12lv  --         /tsmfs02/tsmfs12       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdb08lv  --         /tsmdb/tsmdb08         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs13lv  --         /tsmfs02/tsmfs13       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdb09lv  --         /tsmdb/tsmdb09         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs14lv  --         /tsmfs02/tsmfs14       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdb10lv  --         /tsmdb/tsmdb10         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs15lv  --         /tsmfs02/tsmfs15       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdb11lv  --         /tsmdb/tsmdb11         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs16lv  --         /tsmfs02/tsmfs16       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmdb12lv  --         /tsmdb/tsmdb12         jfs2  524288000 rbrw,noatime,rw no   no 
/dev/tsmfs17lv  --         /tsmfs02/tsmfs17       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmfs18lv  --         /tsmfs02/tsmfs18       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmfs19lv  --         /tsmfs02/tsmfs19       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmfs20lv  --         /tsmfs02/tsmfs20       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmfs21lv  --         /tsmfs02/tsmfs21       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/tsmfs22lv  --         /tsmfs02/tsmfs22       jfs2  34292629504 rbrw,noatime,rw no   no 
/dev/exportlv   --         /export                jfs2  41943040 rw,noatime yes  no 

File system permissions (ls -ld for each file system):

drwxr-xr-x   35 root     system         4096 May 26 06:29 /
drwxr-xr-x    4 root     system          256 May 15 10:11 /admin
drwxr-xr-x    7 root     system          256 May 24 09:58 /export
drwxr-xr-x   10 bin      bin            4096 May 17 09:31 /home
drwxr-xr-x    3 root     system         4096 May 26 00:20 /mksysb
drwxr-xr-x   16 root     system         4096 May 24 14:55 /opt
dr-xr-xr-x    1 root     system            0 May 26 07:39 /proc
drwxrwxrwt   25 bin      bin            8192 May 26 07:39 /tmp
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmactlog
drwxr-xr-x   13 root     system         4096 May 15 10:11 /tsmapps
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmarchlog
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmarchlog2
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb01
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb02
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb03
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb04
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb05
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb06
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb07
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb08
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb09
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb10
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb11
drwxr-xr-x    4 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmdb/tsmdb12
drwxr-xr-x    3 tsmadmin tsmsrvrs       4096 May 26 07:04 /tsmdbbkp/tsmdbbkp01
drwxr-xr-x    3 tsmadmin tsmsrvrs       4096 May 26 07:04 /tsmdbbkp/tsmdbbkp02
drwxr-xr-x    3 tsmadmin tsmsrvrs       4096 May 26 07:03 /tsmdbbkp/tsmdbbkp03
drwxr-xr-x    3 tsmadmin tsmsrvrs       4096 May 26 07:03 /tsmdbbkp/tsmdbbkp04
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs01
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs02
drwxr-xr-x    5 tsmadmin tsmsrvrs       4096 May 15 10:11 /tsmfs01/tsmfs03
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs04
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs05
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs06
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs07
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs08
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs09
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs10
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs01/tsmfs11
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs12
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs13
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs14
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs15
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs16
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs17
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs18
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs19
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs20
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs21
drwxr-xr-x    5 tsmadmin tsmsrvrs        256 May 15 10:11 /tsmfs02/tsmfs22
drwxr-xr-x    4 root     system          256 May 15 10:11 /tsmhome
drwxr-xr-x    4 tsmadmin tsmsrvrs       4096 May 15 10:11 /tsmrecovery
drwxr-xr-x   48 bin      bin            4096 May 15 10:11 /usr
drwxr-xr-x   36 bin      bin            4096 May 26 07:39 /var
drwxr-xr-x    3 root     system          256 May 15 10:11 /var/adm/ras/livedump

2017-05-26 07:39:56: Check checkfsperms.ksh completed successfully: returncode 0
2017-05-26 07:39:56: Runtime: 0 second(s)
2017-05-26 07:39:56: 24% complete - 170 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:56: Running check script 55 of 224: checkftpaccess.ksh

Description:
------------

Displays the contents of file /etc/ftpaccess.ctl.

File /etc/ftpaccess.ctl is a control file that determines who is allowed access to the server. If you 
get "connection refused" messages when using FTP, this is one of the places to look (besides firewall 
settings), to see if connections are denied.

2017-05-26 07:39:56: Check checkftpaccess.ksh completed successfully: returncode 0
2017-05-26 07:39:56: Runtime: 0 second(s)
2017-05-26 07:39:56: 24% complete - 169 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:56: Running check script 56 of 224: checkgangliagmetadconf.ksh

Description:
------------

Check the configuration file for gmetad of Ganglia, if installed.

2017-05-26 07:39:57: Check checkgangliagmetadconf.ksh completed successfully: returncode 0
2017-05-26 07:39:57: Runtime: 1 second(s)
2017-05-26 07:39:57: 25% complete - 168 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:57: Running check script 57 of 224: checkgangliagmondconf.ksh

Description:
------------

Check the configuration file for gmond (Ganglia Monitor Daemon), if Ganglia is installed.

The configuration file for gmond can usually be found at /etc/ganglia/gmond.conf.

2017-05-26 07:39:57: Check checkgangliagmondconf.ksh completed successfully: returncode 0
2017-05-26 07:39:57: Runtime: 0 second(s)
2017-05-26 07:39:57: 25% complete - 167 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:57: Running check script 58 of 224: checkgccversion.ksh

Description:
------------

Check if gcc is installed, and if so, what version.

Output:
------------

Compiler gcc is not installed.

2017-05-26 07:39:57: Check checkgccversion.ksh completed successfully: returncode 0
2017-05-26 07:39:57: Runtime: 0 second(s)
2017-05-26 07:39:57: 25% complete - 166 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:57: Running check script 59 of 224: checkgenkex.ksh

Description:
------------

Runs genkex to display the list of currently loaded kernel extensions.

The following command is run by this check script:

# /usr/bin/genkex

Output:
------------

    Text address     Size File

f1000000c06e6000     f000 /usr/lib/drivers/cfs.ext
         6c20000    20000 /usr/lib/drivers/loopdd
f1000000c06de000     5000 /usr/lib/drivers/phakernmgr
f1000000c06b1000    2d000 /usr/sbin/rsct/bin/haDMS/haDMS_kex
f1000000c0682000    2f000 /usr/lib/drivers/pfcurh
f1000000c0666000    1c000 /usr/lib/drivers/ahafs.ext
f1000000c060e000    58000 /usr/lib/drivers/pfccache
f1000000c0603000     b000 /usr/lib/drivers/pfcreg
f1000000c04ea000   119000 /usr/lib/drivers/pfcdd
         6b80000    20000 /usr/lib/drivers/dpcomdd
f1000000c04ca000    20000 /usr/lib/drivers/random
         6950000   220000 /usr/lib/drivers/nfs.ext
         68f0000    60000 /usr/lib/drivers/krpc.ext
f1000000c04c8000     2000 /usr/lib/drivers/nfs_kdes.ext
f1000000c0431000    97000 /usr/lib/drivers/cluster
f1000000c0426000     b000 /usr/lib/drivers/iocp.ext
         68b0000    20000 /usr/lib/drivers/posix_aiopin
         6890000    20000 /usr/lib/drivers/posix_aio.ext
         6860000    20000 /usr/lib/drivers/aiopin
         6840000    20000 /usr/lib/drivers/aio.ext
f1000000c0424000     2000 /usr/lib/drivers/smt_loadpin
f1000000c041c000     6000 /usr/lib/drivers/smt_load
         67d0000    40000 /usr/pmapi/etc/pmsvcs
         67b0000    20000 /usr/lib/drivers/perfvmmstat
f1000000c0400000    1c000 /usr/lib/drivers/ptydd
         6770000    30000 /usr/lib/perf/perfstat
f1000000c03d2000    2e000 /usr/lib/drivers/ethchandd
         6750000    20000 /usr/lib/drivers/if_en
         6480000   2d0000 /usr/lib/drivers/netinet
f1000000c02a8000   12a000 /usr/lib/drivers/pkcs11
f1000000c0253000    55000 /usr/lib/drivers/crypto/clickext
         6440000    30000 /usr/lib/drivers/usb/usbd
         6410000    30000 /etc/drivers/idecdrompin
         63f0000    20000 /usr/lib/drivers/idecdrom
         6380000    70000 /usr/lib/drivers/pci/xhcidd
         5e10000   570000 /usr/lib/drivers/pci/shientdd
         5df0000    20000 /usr/lib/drivers/eth_demux
f1000000c0251000     2000 /etc/drivers/scsisesddpin
f1000000c0249000     6000 /usr/lib/drivers/scsisesdd
f1000000c022e000    1b000 /usr/lib/drivers/ldterm
f1000000c0225000     9000 /usr/lib/drivers/vconsdd
         5db0000    40000 /usr/lib/drivers/storfwork
f1000000c021d000     5000 /etc/drivers/coreprobe.ext
f1000000c0219000     4000 /usr/lib/drivers/pse/tirdwr
f1000000c0215000     4000 /usr/lib/drivers/pse/timod
f1000000c01f8000    1d000 /usr/lib/drivers/pse/xtiso
f1000000c01f6000     2000 /usr/lib/drivers/pse/stdmod
f1000000c01f2000     3000 /usr/lib/drivers/pse/sc
f1000000c01ee000     3000 /usr/lib/drivers/pse/spx
f1000000c01ea000     3000 /usr/lib/drivers/pse/stddev
f1000000c01e8000     2000 /usr/lib/drivers/ttydbg
f1000000c01e4000     4000 /usr/lib/drivers/ttydbg_pinned
f1000000c018c000    58000 /usr/lib/drivers/pse/pse
         5d50000    50000 /usr/lib/drivers/iscsidd
         5ce0000    70000 /usr/lib/drivers/hd_pin_bot
         5ca0000    40000 /usr/lib/drivers/hd_pin
f1000000c014c000    40000 /usr/lib/drivers/dellscdd
         5c30000    60000 /usr/lib/drivers/aixdiskpcmke
         5bd0000    60000 /etc/drivers/scsidiskpin
         5ba0000    30000 /usr/lib/drivers/scsidisk
         5ac0000    e0000 /usr/lib/drivers/emfscsidd
f1000000c0100000    4c000 /usr/lib/drivers/pci/sischn_dd
         5980000   140000 /usr/lib/drivers/pci/emfcdd
         5950000    30000 /usr/lib/drivers/vdev_busdd
         5900000    50000 /usr/lib/drivers/pci/pci_busdd
         58c0000    40000 /usr/lib/drivers/planar_pal_chrp
         2dc9be8        0 /unix

2017-05-26 07:39:57: Check checkgenkex.ksh completed successfully: returncode 0
2017-05-26 07:39:57: Runtime: 0 second(s)
2017-05-26 07:39:57: 26% complete - 165 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:57: Running check script 60 of 224: checkglvmlsglvm.ksh

Description:
------------

Run lsglvm to display physical disks configured for use in GLVM (Geographic Logical Volume Management). 

GLVM can be used in combination with PowerHA, commonly known as PowerHA/XD for clusters that span large 
distances. GLVM can sync file system data over the network instead of storage fibre.

To display the GLVM disks, run:

# lsglvm

To access GLVM utils, you can also run:

# smitty glvm_utils

2017-05-26 07:39:57: Check checkglvmlsglvm.ksh completed successfully: returncode 0
2017-05-26 07:39:57: Runtime: 0 second(s)
2017-05-26 07:39:57: 26% complete - 164 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:57: Running check script 61 of 224: checkglvmlsrpvclient.ksh

Description:
------------

Check script to run lsrpvclient, to display all remote physical volume clients configured for use in 
GLVM (Geographic Logical Volume Management).

To display all the remote physical volume clients in use for GLVM, run:

# lsrpvclient -H

2017-05-26 07:39:57: Check checkglvmlsrpvclient.ksh completed successfully: returncode 0
2017-05-26 07:39:57: Runtime: 0 second(s)
2017-05-26 07:39:57: 27% complete - 163 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:57: Running check script 62 of 224: checkglvmlsrpvserver.ksh

Description:
------------

Check script to run lsrpvserver, to display all remote physical volume servers configured for use in 
GLVM (Geographic Logical Volume Management).

To display all the remote physical volume servers in use for GLVM, run:

# lsrpvserver -H

2017-05-26 07:39:58: Check checkglvmlsrpvserver.ksh completed successfully: returncode 0
2017-05-26 07:39:58: Runtime: 0 second(s)
2017-05-26 07:39:58: 27% complete - 162 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:58: Running check script 63 of 224: checkglvmrpvstat.ksh

Description:
------------

Check script to run rpvstat, to display Remote Physical Volume statistics for GLVM (Geographic Logical 
Volume Management), if present on the system.

To display the Remote Physical Volume statistics, run:

# rpvstat

2017-05-26 07:39:58: Check checkglvmrpvstat.ksh completed successfully: returncode 0
2017-05-26 07:39:58: Runtime: 0 second(s)
2017-05-26 07:39:58: 28% complete - 161 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:58: Running check script 64 of 224: checkhardwareplatform.ksh

Description:
------------

Checks the value of the hardware platform.

Output:
------------

rspc

2017-05-26 07:39:58: Check checkhardwareplatform.ksh completed successfully: returncode 0
2017-05-26 07:39:58: Runtime: 0 second(s)
2017-05-26 07:39:58: 28% complete - 160 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:58: Running check script 65 of 224: checkhdlmhba.ksh

Description:
------------

Displays any Hitachi Data Link Manager HBAs.

This check script will run the following command, if available on the system:

# /usr/DynamicLinkManager/bin/dlnkmgr view -hba

2017-05-26 07:39:58: Check checkhdlmhba.ksh completed successfully: returncode 0
2017-05-26 07:39:58: Runtime: 0 second(s)
2017-05-26 07:39:58: 29% complete - 159 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:58: Running check script 66 of 224: checkhdlmpath.ksh

Description:
------------

Displays any Hitachi Data Link Manager paths.

This check script will run the following command, if available on the system:

# /usr/DynamicLinkManager/bin/dlnkmgr view -path -srt lu

2017-05-26 07:39:58: Check checkhdlmpath.ksh completed successfully: returncode 0
2017-05-26 07:39:58: Runtime: 0 second(s)
2017-05-26 07:39:58: 29% complete - 158 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:58: Running check script 67 of 224: checkhdlmsys.ksh

Description:
------------

Display Hitachi Data Link Manager status and environment settings.

This check script will run the following command, if available on the system:

# /usr/DynamicLinkManager/bin/dlnkmgr view -sys

2017-05-26 07:39:58: Check checkhdlmsys.ksh completed successfully: returncode 0
2017-05-26 07:39:58: Runtime: 0 second(s)
2017-05-26 07:39:58: 29% complete - 157 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:58: Running check script 68 of 224: checkhphsvpaths.ksh

Description:
------------

Run HP StorageWorks hsvpaths command to provide a summary the HSV IO paths.

This check script will run the following command, if available on the system:

# /opt/hphsv/bin/hsvpaths

2017-05-26 07:39:58: Check checkhphsvpaths.ksh completed successfully: returncode 0
2017-05-26 07:39:58: Runtime: 0 second(s)
2017-05-26 07:39:58: 30% complete - 156 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:58: Running check script 69 of 224: checkhplshba.ksh

Description:
------------

Run HP StorageWorks lshba command to display all HBAs, if installed.

This script runs the following command, if available on the system:

# /opt/hphsv/bin/lshba

2017-05-26 07:39:59: Check checkhplshba.ksh completed successfully: returncode 0
2017-05-26 07:39:59: Runtime: 0 second(s)
2017-05-26 07:39:59: 30% complete - 155 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:59: Running check script 70 of 224: checkhplshsv.ksh

Description:
------------

Run HP StorageWorks lshsv command to display all EVA disks, if installed.

This check script will run the following command, if available on the system:

# /opt/hphsv/bin/lshsv

2017-05-26 07:39:59: Check checkhplshsv.ksh completed successfully: returncode 0
2017-05-26 07:39:59: Runtime: 0 second(s)
2017-05-26 07:39:59: 31% complete - 154 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:59: Running check script 71 of 224: checkhplshsvp.ksh

Description:
------------

Run HP StorageWorks lshsv command to display all IO paths to EVA disks, if installed.

This check script will run the following command, if available on the system:

# /opt/hphsv/bin/lshsv -p

2017-05-26 07:39:59: Check checkhplshsvp.ksh completed successfully: returncode 0
2017-05-26 07:39:59: Runtime: 0 second(s)
2017-05-26 07:39:59: 31% complete - 153 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:59: Running check script 72 of 224: checkhplshsvs.ksh

Description:
------------

Run HP StorageWorks lshsv command to list a summary of all EVA disk arrays connected to the system.

This check script will run the following command, if available on the system:

# /opt/hphsv/bin/lshsv -s

2017-05-26 07:39:59: Check checkhplshsvs.ksh completed successfully: returncode 0
2017-05-26 07:39:59: Runtime: 0 second(s)
2017-05-26 07:39:59: 32% complete - 152 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:59: Running check script 73 of 224: checkifconfig.ksh

Description:
------------

Shows the configuration of the network interfaces.

The output shown is in the following order:

Adapter
Interface
IP address
MAC Address

And the following, if it is applicable:

Network speed
Duplex status (half/full)
Autonegotiate status

Output:
------------

ent8 en8 192.18.42.43 255.255.255.0 98:be:94:69:85:98
ent8 en8 192.18.42.45 255.255.255.0 98:be:94:69:85:98

2017-05-26 07:39:59: Check checkifconfig.ksh completed successfully: returncode 0
2017-05-26 07:39:59: Runtime: 0 second(s)
2017-05-26 07:39:59: 32% complete - 151 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:39:59: Running check script 74 of 224: checkinetd.ksh

Description:
------------

Displays the active inetd services.

This check script will run the following command:

# /usr/bin/lssrc -l -s inetd


Output:
------------

Subsystem         Group            PID          Status 
 inetd            tcpip            5505224      active
Debug         Not active 
Signal        Purpose 
 SIGALRM      Establishes socket connections for failed services. 
 SIGHUP       Rereads the configuration database and reconfigures services. 
 SIGCHLD      Restarts the service in case the service ends abnormally. 
Service       Command                  Description              Status 
 tftp         /usr/sbin/tftpd          tftpd -n                 active
 bootps       /usr/sbin/bootpd         bootpd /etc/bootptab     active
 caa_cfg      /usr/sbin/clusterconf    clusterconf              active

2017-05-26 07:39:59: Check checkinetd.ksh completed successfully: returncode 0
2017-05-26 07:39:59: Runtime: 0 second(s)
2017-05-26 07:39:59: 33% complete - 150 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:00: Running check script 75 of 224: checkinetdconffile.ksh

Description:
------------

Displays the content of /etc/inetd.conf.

This script will not display any lines that are commented out in /etc/inetd.conf.

The check script will run the following command:

# grep -v ^# /etc/inetd.conf

Output:
------------

bootps	dgram   udp     wait    root    /usr/sbin/bootpd       bootpd /etc/bootptab
tftp	 dgram	udp6	SRC	nobody	/usr/sbin/tftpd		tftpd -n
caa_cfg	stream	tcp6	nowait	root	/usr/sbin/clusterconf clusterconf 
>>/var/adm/ras/clusterconf.log 2>&1

2017-05-26 07:40:00: Check checkinetdconffile.ksh completed successfully: returncode 0
2017-05-26 07:40:00: Runtime: 0 second(s)
2017-05-26 07:40:00: 33% complete - 149 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:00: Running check script 76 of 224: checkinittab.ksh

Description:
------------

Displays the contents of /etc/inittab.

This script will not display any lines that are commented out in /etc/inittab. Lines are commented out 
by using a colon.

The /etc/inittab file contains entries that are run during system startup.

This check script will run the following command:

# grep -v ^: /etc/inittab

Output:
------------

init:2:initdefault:
brc::sysinit:/sbin/rc.boot 3 >/dev/console 2>&1 # Phase 3 of system boot
powerfail::powerfail:/etc/rc.powerfail 2>&1 | alog -tboot > /dev/console # Power Failure Detection
mkatmpvc:2:once:/usr/sbin/mkatmpvc >/dev/console 2>&1
atmsvcd:2:once:/usr/sbin/atmsvcd >/dev/console 2>&1
tunables:23456789:wait:/usr/sbin/tunrestore -R > /dev/console 2>&1 # Set tunables
securityboot:2:bootwait:/etc/rc.security.boot > /dev/console 2>&1
rc:23456789:wait:/etc/rc 2>&1 | alog -tboot > /dev/console # Multi-User checks
srcmstr:23456789:respawn:/usr/sbin/srcmstr # System Resource Controller
rctcpip:2:wait:/etc/rc.tcpip > /dev/console 2>&1 # Start TCP/IP daemons
nim:2:wait:/usr/bin/startsrc -g nim >/dev/console 2>&1
harc:2:wait:/usr/es/sbin/cluster/etc/harc.net # HACMP for AIX network startup
hrd:2:once:/usr/bin/startsrc -g hrd > /dev/console 2>&1
aso:23456789:once:/usr/bin/startsrc -s aso
rcnfs:2:wait:/etc/rc.nfs > /dev/console 2>&1 # Start NFS Daemons
fbcheck:23456789:wait:/usr/sbin/fbcheck 2>&1 | alog -tboot > /dev/console # run /etc/firstboot
cron:23456789:respawn:/usr/sbin/cron
clusterconf:23456789:once:/usr/sbin/clusterconf
cons:0123456789:respawn:/usr/sbin/getty /dev/console
shdaemon:2:off:/usr/sbin/shdaemon >/dev/console 2>&1 # High availability daemon
trustedboot:2:wait:/etc/rc.trustedboot > /dev/console 2>&1 # Get trusted log and start TCSD
l2:2:wait:/etc/rc.d/rc 2 
l3:3:wait:/etc/rc.d/rc 3 
l4:4:wait:/etc/rc.d/rc 4 
l5:5:wait:/etc/rc.d/rc 5 
l6:6:wait:/etc/rc.d/rc 6 
l7:7:wait:/etc/rc.d/rc 7 
l8:8:wait:/etc/rc.d/rc 8 
l9:9:wait:/etc/rc.d/rc 9 
rcml:2:once:/usr/ml/aix71/rc.ml > /dev/console 2>&1
rcwpars:2:once:/etc/rc.wpars > /dev/console 2>&1 # Corrals autostart
logsymp:2:once:/usr/lib/ras/logsymptom # for system dumps
pfcdaemon:2:once:/usr/bin/startsrc -s pfcdaemon  > /dev/null 2>&1
perfstat:2:once:/usr/lib/perf/libperfstat_updt_dictionary >/dev/console 2>&1
diagd:2:once:/usr/lpp/diagnostics/bin/diagd >/dev/console 2>&1
pmperfrec:2:once:/var/perf/pm/bin/config_pm_ext.sh -P yes
clcomd:23456789:once:/usr/bin/startsrc -s clcomd
xmdaily:2:once:/usr/bin/topasrec -L -s 300 -R 1 -r 6 -o /var/perf/daily/ -ypersistent=1 2>&1 >/dev/null 
#Start local binary recording
ctrmc:2:once:/usr/bin/startsrc -s ctrmc > /var/ct/ctrmc-inittab.err 2>&1
ha_star:h2:once:/etc/rc.ha_star >/dev/console 2>&1
hacmp:2:once:/usr/es/sbin/cluster/etc/rc.init >/dev/console 2>&1
fmc:2:respawn:/opt/tivoli/tsm/db2/bin/db2fmcd #DB2 Fault Monitor Coordinator

2017-05-26 07:40:00: Check checkinittab.ksh completed successfully: returncode 0
2017-05-26 07:40:00: Runtime: 0 second(s)
2017-05-26 07:40:00: 33% complete - 148 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:00: Running check script 77 of 224: checkinstfix.ksh

Description:
------------

Runs the instfix command to determine the technology levels that are known to the system.

This check script will run the following command:

# instfix -i | grep ML

Output:
------------

All filesets for 7.1.0.0_AIX_ML were found.
All filesets for 7100-00_AIX_ML were found.
All filesets for 7100-01_AIX_ML were found.
All filesets for 7100-02_AIX_ML were found.
All filesets for 7100-03_AIX_ML were found.
All filesets for 7100-04_AIX_ML were found.

2017-05-26 07:40:02: Check checkinstfix.ksh completed successfully: returncode 0
2017-05-26 07:40:02: Runtime: 2 second(s)
2017-05-26 07:40:02: 34% complete - 147 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:02: Running check script 78 of 224: checkiooa.ksh

Description:
------------

Lists the IO options.

This check script will run the following command:

# /usr/sbin/ioo -a

Output:
------------

                    aio_active = 1
                   aio_maxreqs = 131072
                aio_maxservers = 30
                aio_minservers = 3
         aio_server_inactivity = 300
         j2_atimeUpdateSymlink = 0
 j2_dynamicBufferPreallocation = 16
             j2_inodeCacheSize = 200
           j2_maxPageReadAhead = 128
             j2_maxRandomWrite = 0
          j2_metadataCacheSize = 200
           j2_minPageReadAhead = 2
j2_nPagesPerWriteBehindCluster = 32
             j2_nRandomCluster = 0
               j2_recoveryMode = 1
                  j2_syncByVFS = 0
            j2_syncConcurrency = 4
            j2_syncDelayReport = 600
              j2_syncPageCount = 0
              j2_syncPageLimit = 16
                    lvm_bufcnt = 9
                    maxpgahead = 8
                    maxrandwrt = 0
                      numclust = 1
                     numfsbufs = 196
                     pd_npages = 4096
              posix_aio_active = 0
             posix_aio_maxreqs = 131072
          posix_aio_maxservers = 30
          posix_aio_minservers = 3
   posix_aio_server_inactivity = 300
             spec_accessupdate = 0

2017-05-26 07:40:02: Check checkiooa.ksh completed successfully: returncode 0
2017-05-26 07:40:02: Runtime: 0 second(s)
2017-05-26 07:40:02: 34% complete - 146 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:02: Running check script 79 of 224: checkipaddress.ksh

Description:
------------

Retrieves the IP address of the server, by deriving it from the hostname.

If the hostname can't be found in the /etc/hosts file, this check will generate an error.

Output:
------------

192.18.42.43

2017-05-26 07:40:02: Check checkipaddress.ksh completed successfully: returncode 0
2017-05-26 07:40:02: Runtime: 0 second(s)
2017-05-26 07:40:02: 35% complete - 145 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:02: Running check script 80 of 224: checkiplvaryon.ksh

Description:
------------

Run ipl_varyon -i to display which disks are bootable.

This check script will run the following command:

# /usr/sbin/ipl_varyon -i

Output:
------------

PVNAME		BOOT DEVICE	PVID			VOLUME GROUP ID
hdisk0		YES		00fab085b321dc730000000000000000	00fab08500004c00
hdisk1		YES		00fab085bd0bee890000000000000000	00fab08500004c00
hdisk2		NO		00fab085c266b60c0000000000000000	00fab08500004c00
hdisk4		NO		00fab085c266a9d60000000000000000	00fab08500004c00
hdisk7		NO		00fab085c266a46c0000000000000000	00fab08500004c00
hdisk10		NO		00fab085c266bb450000000000000000	00fab08500004c00
hdisk13		NO		00fab085c266b9b10000000000000000	00fab08500004c00
hdisk14		NO		00fab085c266b9300000000000000000	00fab08500004c00
hdisk16		NO		00fab085c266b82b0000000000000000	00fab08500004c00
hdisk17		NO		00fab085c266b79d0000000000000000	00fab08500004c00
hdisk19		NO		00fab085c266b68d0000000000000000	00fab08500004c00
hdisk20		NO		00fab085c266b58a0000000000000000	00fab08500004c00
hdisk22		NO		00fab085c266b4800000000000000000	00fab08500004c00
hdisk3		NO		00fab085c266b01c0000000000000000	00fab08500004c00
hdisk5		NO		00fab085c266a59b0000000000000000	00fab08500004c00
hdisk15		NO		00fab085c266b8a60000000000000000	00fab08500004c00
hdisk18		NO		00fab085c266b7190000000000000000	00fab08500004c00
hdisk21		NO		00fab085c266b50d0000000000000000	00fab08500004c00
hdisk23		NO		00fab085c266b4000000000000000000	00fab08500004c00
hdisk25		NO		00fab085c266b2ed0000000000000000	00fab08500004c00
hdisk35		NO		00fab085c266ac660000000000000000	00fab08500004c00
hdisk38		NO		00fab085c266aad70000000000000000	00fab08500004c00
hdisk41		NO		00fab085c266a8ca0000000000000000	00fab08500004c00
hdisk44		NO		00fab085c266a7240000000000000000	00fab08500004c00
hdisk46		NO		00fab085c266a6210000000000000000	00fab08500004c00
hdisk8		NO		00fab085c266a3de0000000000000000	00fab08500004c00
hdisk11		NO		00fab085c266babc0000000000000000	00fab08500004c00
hdisk28		NO		00fab085c266b1350000000000000000	00fab08500004c00
hdisk31		NO		00fab085c266aefe0000000000000000	00fab08500004c00
hdisk9		NO		00fab085c266a3170000000000000000	00fab08500004c00
hdisk42		NO		00fab085c266a8380000000000000000	00fab08500004c00
hdisk12		NO		00fab085c266ba3a0000000000000000	00fab08500004c00
hdisk32		NO		00fab085c266ae780000000000000000	00fab08500004c00
hdisk24		NO		00fab085c266b36b0000000000000000	00fab08500004c00
hdisk27		NO		00fab085c266b1cc0000000000000000	00fab08500004c00
hdisk30		NO		00fab085c266af8a0000000000000000	00fab08500004c00
hdisk33		NO		00fab085c266adc90000000000000000	00fab08500004c00
hdisk34		NO		00fab085c266ace70000000000000000	00fab08500004c00
hdisk36		NO		00fab085c266abe40000000000000000	00fab08500004c00
hdisk37		NO		00fab085c266ab5a0000000000000000	00fab08500004c00
hdisk39		NO		00fab085c266aa560000000000000000	00fab08500004c00
hdisk40		NO		00fab085c266a94f0000000000000000	00fab08500004c00
hdisk43		NO		00fab085c266a7a10000000000000000	00fab08500004c00
hdisk45		NO		00fab085c266a69e0000000000000000	00fab08500004c00
hdisk26		NO		00fab085c266b25a0000000000000000	00fab08500004c00
hdisk29		NO		00fab085c266b0a20000000000000000	00fab08500004c00
hdisk47		NO		00fab085b5045df10000000000000000	00fab08500004c00

2017-05-26 07:40:07: Check checkiplvaryon.ksh completed successfully: returncode 0
2017-05-26 07:40:07: Runtime: 5 second(s)
2017-05-26 07:40:07: 35% complete - 144 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:07: Running check script 81 of 224: checkjavalevel.ksh

Description:
------------

Displays the Java version installed.

This check script runs the following command:

# java -fullversion

Output:
------------

java full version JRE 1.6.0 IBM AIX build pap3260sr16fp26-20160508_01 (SR16 FP26)

2017-05-26 07:40:07: Check checkjavalevel.ksh completed successfully: returncode 0
2017-05-26 07:40:07: Runtime: 0 second(s)
2017-05-26 07:40:07: 36% complete - 143 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:07: Running check script 82 of 224: checkjfs2snapshots.ksh

Description:
------------

List any external and internal JFS2 snapshots.

For each existing file system, the following command will be run. For example, for the /mount/files 
file system:

# /usr/sbin/snapshot -q /mount/files

2017-05-26 07:40:21: Check checkjfs2snapshots.ksh completed successfully: returncode 0
2017-05-26 07:40:21: Runtime: 14 second(s)
2017-05-26 07:40:21: 36% complete - 142 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:21: Running check script 83 of 224: checkkdriver.ksh

Description:
------------

Check if EMC RecoverPoint software (kdriver) is installed, and if so, what version.

This check script will run the following command:

# lslpp -l kdriver.bin

If this software is no longer needed, these are the steps to uninstall this software from an AIX 
system:

1. Using the RecoverPoint CLI or Management Console:
    a. Detach all volumes from the host.
    b. Remove the host.
2. Login to the host as user root.
3. Use the /kdriver/bin/kutils stop command to stop the KDriver.
4. Run /kdriver/bin/rc.kdrv uninstall.

2017-05-26 07:40:21: Check checkkdriver.ksh completed successfully: returncode 0
2017-05-26 07:40:21: Runtime: 0 second(s)
2017-05-26 07:40:21: 37% complete - 141 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:21: Running check script 84 of 224: checkkernel.ksh

Description:
------------

Displays the kernel in use.

This check script will run the following commands:

# ls -al /unix
# ls -al /usr/lib/boot/uni*

Output:
------------

ls -al /unix
------------------------------
lrwxrwxrwx    1 root     system           21 Nov 29 19:25 /unix -> /usr/lib/boot/unix_64

ls -al /usr/lib/boot/uni*
------------------------------
lrwxrwxrwx    1 root     system           21 Nov 29 19:25 /usr/lib/boot/unix -> /usr/lib/boot/unix_64
-r-xr-xr-x    1 root     system     36745393 Oct 10 2016  /usr/lib/boot/unix_64

2017-05-26 07:40:21: Check checkkernel.ksh completed successfully: returncode 0
2017-05-26 07:40:21: Runtime: 0 second(s)
2017-05-26 07:40:21: 37% complete - 140 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:21: Running check script 85 of 224: checkkrb5conf.ksh

Description:
------------

Display the contents of /etc/krb5.conf for Kerberos authentications, if the file exists.

krb5.conf contains configuration information needed by the Kerberos V5 library. This includes 
information describing the default Kerberos realm, and the location of the Kerberos key distribution 
centers for known realms.

2017-05-26 07:40:21: Check checkkrb5conf.ksh completed successfully: returncode 0
2017-05-26 07:40:21: Runtime: 0 second(s)
2017-05-26 07:40:21: 37% complete - 139 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:21: Running check script 86 of 224: checkl2cachesize.ksh

Description:
------------

Displays the L2 cache size in kilobytes.

It is common for the L2 cache size to be reported as zero (0) on virtual clients.

This check script runs the following command:

# lsattr -El L2cache0 -a size

Output:
------------

512

2017-05-26 07:40:22: Check checkl2cachesize.ksh completed successfully: returncode 0
2017-05-26 07:40:22: Runtime: 0 second(s)
2017-05-26 07:40:22: 38% complete - 138 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:22: Running check script 87 of 224: checklcpucount.ksh

Description:
------------

Shows the amount of logical CPUs defined on the system.

This check script will run the following command:

# vmstat | grep lcpu

A logical CPU is not the same as a physical or virtual CPU. The number of logical CPUs includes any 
symmetric multi-threading on a system. 

If for example, on a Power7 system, 2 virtual CPUs are defined to an LPAR, and the system is capable of 
multi-threading of 4 (use the smtctl command to see the SMT value of a system), this will result in 
having 2 times 4, is 8 logical CPUs.

Output:
------------

192

2017-05-26 07:40:22: Check checklcpucount.ksh completed successfully: returncode 0
2017-05-26 07:40:22: Runtime: 0 second(s)
2017-05-26 07:40:22: 38% complete - 137 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:22: Running check script 88 of 224: checklibpathduplicates.ksh

Description:
------------

Check if duplicate folders in the $LIBPATH variable exist on the server.

Duplicate entries in $LIBPATH may only slow down the system while searching for the correct library or 
libraries to run. Please remove any duplicate entries.

2017-05-26 07:40:22: Check checklibpathduplicates.ksh completed successfully: returncode 0
2017-05-26 07:40:22: Runtime: 0 second(s)
2017-05-26 07:40:22: 39% complete - 136 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:22: Running check script 89 of 224: checklibpathstatements.ksh

Description:
------------

Display the $LIBPATH statements in /etc/profile and /etc/environment.

The system variable $LIBPATH is set in either /etc/profile and/or /etc/environment. Users can alter the 
$LIBPATH as they log in to the system. 

Setting the $LIBPATH variable correctly is necessary to ensure that the correct libraries are found by 
the system, and hackers can not use it to have malicious software executed first. Therefore the order 
of the paths in the $LIBPATH variable is important. Also ensure that no dots are present in $LIBPATH, 
as this may allow an attacker to trick a user run a library from a different directory.

Output:
------------

$LIBPATH is not set.

2017-05-26 07:40:22: Check checklibpathstatements.ksh completed successfully: returncode 0
2017-05-26 07:40:22: Runtime: 0 second(s)
2017-05-26 07:40:22: 39% complete - 135 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:22: Running check script 90 of 224: checklimits.ksh

Description:
------------

Displays the contents of /etc/security/limits.

Output:
------------

default:
	fsize = -1
	core = 2097151
	cpu = -1
	data = 262144
	rss = 65536
	stack =	65536
	nofiles = 65536 
root:
	stack = -1
	stack_hard = -1
	rss = -1
	nofiles = -1
	data = -1
	core = -1
daemon:
bin:
sys:
adm:
uucp:
guest:
nobody:
lpd:

2017-05-26 07:40:22: Check checklimits.ksh completed successfully: returncode 0
2017-05-26 07:40:22: Runtime: 0 second(s)
2017-05-26 07:40:22: 40% complete - 134 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:22: Running check script 91 of 224: checklinklocal.ksh

Description:
------------

Display any link-local network addresses configured.

In a computer network, a link-local address is a network address that is valid only for communications 
within the network segment (link) or the broadcast  domain that the host is connected to. Link-local 
addresses are usually not guaranteed to be unique beyond a single network segment. Routers therefore do 
not forward packets with link-local addresses. Link-local addresses for IPv4 are defined in the address 
block 169.254.0.0/16. Link-local addresses may be assigned manually by an administrator or by automatic 
operating system procedures. For Internet Protocol (IP) networks, they are assigned most often using 
stateless address autoconfiguration. In IPv4, they are normally only used to assign IP addresses to 
network interfaces when no external, stateful mechanism of address configuration exists, such as the 
Dynamic Host Configuration Protocol (DHCP), or when another primary configuration method has failed.

A known application using link-local IP addresses is Oracle RAC.

For more information, see: http://en.wikipedia.org/wiki/Link-local_address

2017-05-26 07:40:22: Check checklinklocal.ksh completed successfully: returncode 0
2017-05-26 07:40:22: Runtime: 0 second(s)
2017-05-26 07:40:22: 40% complete - 133 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:22: Running check script 92 of 224: checkloadaverage.ksh

Description:
------------

Checks the average load of the system.

The average load of the system is determined, by running the uptime command.

Output:
------------

3.49

2017-05-26 07:40:23: Check checkloadaverage.ksh completed successfully: returncode 0
2017-05-26 07:40:23: Runtime: 0 second(s)
2017-05-26 07:40:23: 41% complete - 132 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:23: Running check script 93 of 224: checkloginnamemax.ksh

Description:
------------

Shows the maximum login name length. 

Starting with AIX 5.3, the login name length is no longer limited to 8. For more information, please 
refer to:

http://www.unixhealthcheck.com/blog.php?id=299

To determine the maximum login name length, run:

# lsattr -El sys0 -a max_logname

Output:
------------

The max_logname attribute is set to default 9.

2017-05-26 07:40:23: Check checkloginnamemax.ksh completed successfully: returncode 0
2017-05-26 07:40:23: Runtime: 0 second(s)
2017-05-26 07:40:23: 41% complete - 131 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:23: Running check script 94 of 224: checklpar.ksh

Description:
------------

Check if this server is an LPAR.

Output:
------------

Yes

2017-05-26 07:40:23: Check checklpar.ksh completed successfully: returncode 0
2017-05-26 07:40:23: Runtime: 0 second(s)
2017-05-26 07:40:23: 41% complete - 130 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:23: Running check script 95 of 224: checklparcpusettings.ksh

Description:
------------

Check the LPAR CPU settings of an AIX system (minimum, desired and maximum CPU's).

This check script uses the lparstat command to determine the LPAR CPU settings:

# /usr/bin/lparstat -i

Output:
------------

Min: 1 Des: 24 Max: 24 SystemMAX: 24 SystemActive: 24

2017-05-26 07:40:23: Check checklparcpusettings.ksh completed successfully: returncode 0
2017-05-26 07:40:23: Runtime: 0 second(s)
2017-05-26 07:40:23: 42% complete - 129 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:23: Running check script 96 of 224: checklparmemory.ksh

Description:
------------

Displays the settings for memory of the AIX LPAR (minimum, desired, maximum) in megabytes.

Run the following commands to view the current settings:

To view the currently assigned memory:

# lsattr -El mem0

To view the LPAR settings:

# lparstat -i

To view memory in use by the Hypervisor, run on the HMC command line:

# lshwres -r mem -m <managed system name> --level sys

To determine the managed system name, run on the HMC command line:

# lssyscfg -r sys -F name

To view the memory settings for each LPAR on a managed frame, run on the HMC command line:

# lssyscfg -m <managed system name> -r prof -F lpar_name,name,min_mem,desired_mem,max_mem

Output:
------------

Minimum: 256 Desired: 255744 Maximum: 262144 Online: 255744

2017-05-26 07:40:23: Check checklparmemory.ksh completed successfully: returncode 0
2017-05-26 07:40:23: Runtime: 0 second(s)
2017-05-26 07:40:23: 42% complete - 128 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:23: Running check script 97 of 224: checklparmode.ksh

Description:
------------

Check the LPAR type and mode on AIX systems.

This check script runs the following command:

# /usr/bin/lparstat

Output:
------------

type=Dedicated mode=Capped

2017-05-26 07:40:24: Check checklparmode.ksh completed successfully: returncode 0
2017-05-26 07:40:24: Runtime: 0 second(s)
2017-05-26 07:40:24: 43% complete - 127 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:24: Running check script 98 of 224: checklparno.ksh

Description:
------------

Checks the number of the AIX LPAR.

This check script runs the following command:

# uname -L

Output:
------------

1 TSM0001

2017-05-26 07:40:24: Check checklparno.ksh completed successfully: returncode 0
2017-05-26 07:40:24: Runtime: 0 second(s)
2017-05-26 07:40:24: 43% complete - 126 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:24: Running check script 99 of 224: checklparstat.ksh

Description:
------------

This check script runs the lparstat -i command, in order to report logical partition (LPAR) related 
information and statistics.

Output:
------------

Node Name                                  : tsm0001
Partition Name                             : TSM0001
Partition Number                           : 1
Type                                       : Dedicated-SMT-8
Mode                                       : Capped
Entitled Capacity                          : 24.00
Partition Group-ID                         : 32769
Shared Pool ID                             : -
Online Virtual CPUs                        : 24
Maximum Virtual CPUs                       : 24
Minimum Virtual CPUs                       : 1
Online Memory                              : 255744 MB
Maximum Memory                             : 262144 MB
Minimum Memory                             : 256 MB
Variable Capacity Weight                   : -
Minimum Capacity                           : 1.00
Maximum Capacity                           : 24.00
Capacity Increment                         : 1.00
Maximum Physical CPUs in system            : 24
Active Physical CPUs in system             : 24
Active CPUs in Pool                        : -
Shared Physical CPUs in system             : 0
Maximum Capacity of Pool                   : 0
Entitled Capacity of Pool                  : 0
Unallocated Capacity                       : -
Physical CPU Percentage                    : 100.00%
Unallocated Weight                         : -
Memory Mode                                : Dedicated
Total I/O Memory Entitlement               : -
Variable Memory Capacity Weight            : -
Memory Pool ID                             : -
Physical Memory in the Pool                : -
Hypervisor Page Size                       : -
Unallocated Variable Memory Capacity Weight: -
Unallocated I/O Memory entitlement         : -
Memory Group ID of LPAR                    : -
Desired Virtual CPUs                       : 24
Desired Memory                             : 255744 MB
Desired Variable Capacity Weight           : -
Desired Capacity                           : 24.00
Target Memory Expansion Factor             : -
Target Memory Expansion Size               : -
Power Saving Mode                          : Disabled
Sub Processor Mode                         : -

2017-05-26 07:40:24: Check checklparstat.ksh completed successfully: returncode 0
2017-05-26 07:40:24: Runtime: 0 second(s)
2017-05-26 07:40:24: 44% complete - 125 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:24: Running check script 100 of 224: checklsauthent.ksh

Description:
------------

Run the lsauthent command to display the available authentication methods currently configured on the 
system.

This check script runs the following command:

# /usr/bin/lsauthent

Output:
------------

Standard Aix

2017-05-26 07:40:24: Check checklsauthent.ksh completed successfully: returncode 0
2017-05-26 07:40:24: Runtime: 0 second(s)
2017-05-26 07:40:24: 44% complete - 124 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:24: Running check script 101 of 224: checklscfg.ksh

Description:
------------

Displays configuration, diagnostic, and vital product data (VPD) information about the system by 
running lscfg.

Output:
------------

INSTALLED RESOURCE LIST

The following resources are installed on the machine.
+/- = Added or deleted from Resource List.
*   = Diagnostic support not available.
	
  Model Architecture: chrp
  Model Implementation: Multiple Processor, PCI bus
	
+ sys0                                                                           System Object
+ sysplanar0                                                                     System Planar
* vio0                                                                           Virtual I/O Bus
* vsa0             U8286.42A.21C096X-V1-C0                                       LPAR Virtual Serial 
Adapter
* vty0             U8286.42A.21C096X-V1-C0-L0                                    Asynchronous Terminal
* pci13            U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ fcs2             U78C9.001.WZS0TLH-P1-C3-T1                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)
* fscsi2           U78C9.001.WZS0TLH-P1-C3-T1                                    FC SCSI I/O Controller 
Protocol Device
* pdisk180         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk181         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk182         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk183         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk184         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk185         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk186         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk187         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk188         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk189         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk190         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk191         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk192         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk193         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk194         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk195         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk196         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk197         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk198         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk199         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk200         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk201         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk202         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk203         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk204         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk205         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk206         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk207         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk208         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk209         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk210         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk211         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk212         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk213         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk214         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk215         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk216         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk217         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk218         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk219         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk220         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk221         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk222         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk223         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk224         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk225         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk226         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk227         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk228         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk229         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk230         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk231         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk232         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk233         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk234         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk235         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk236         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk237         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk238         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk239         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk240         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk241         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk242         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk243         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk244         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk245         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk246         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk247         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk248         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk249         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk250         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk251         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk252         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk253         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk254         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk255         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk256         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk257         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk258         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk259         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk260         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk261         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk262         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk263         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk264         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk265         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk266         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk267         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk268         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk269         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk364         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk365         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* sfwcomm2         U78C9.001.WZS0TLH-P1-C3-T1-W0-L0                              Fibre Channel Storage 
Framework Comm
+ fcs3             U78C9.001.WZS0TLH-P1-C3-T2                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)
* fscsi3           U78C9.001.WZS0TLH-P1-C3-T2                                    FC SCSI I/O Controller 
Protocol Device
* pdisk270         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk271         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk272         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk273         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk274         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk275         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk276         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk277         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk278         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk279         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk280         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk281         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk282         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk283         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk284         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk285         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk286         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk287         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk288         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk289         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk290         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk291         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk292         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk293         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk294         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk295         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk296         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk297         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk298         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk299         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk300         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk301         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk302         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk303         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk304         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk305         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk306         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk307         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk308         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk309         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk310         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk311         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk312         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk313         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk314         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk315         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk316         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk317         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk318         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk319         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk320         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk321         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk322         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk323         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk324         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk325         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk326         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk327         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk328         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk329         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk330         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk331         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk332         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk333         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk334         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk335         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk336         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk337         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk338         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk339         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk340         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk341         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk342         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk343         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk344         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk345         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk346         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk347         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk348         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk349         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk350         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk351         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk352         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk353         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk354         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk355         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk356         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk357         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk358         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk359         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk366         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk367         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* sfwcomm3         U78C9.001.WZS0TLH-P1-C3-T2-W0-L0                              Fibre Channel Storage 
Framework Comm
* pci12            U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci11            U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci10            U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci9             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ sissas1          U78C9.001.WZS0TLH-P1-C15-T1                                   PCIe3 x8 SAS RAID 
Internal Adapter 6Gb
* sas1             U78C9.001.WZS0TLH-P1-C15-T1                                   Controller SAS 
Protocol
* sfwcomm5                                                                       SAS Storage Framework 
Comm
+ hdisk1           U78C9.001.WZS0TLH-P2-D1                                       SAS 4K Disk Drive 
(600000 MB)
+ ses1             U78C9.001.WZS0TLH-P2-Y1                                       SAS Enclosure Services 
Device
* sata1            U78C9.001.WZS0TLH-P1-C15-T1                                   Controller SATA 
Protocol
* pci8             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ ent4             U78C9.001.WZS0TLH-P1-C10-T1                                   PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)
+ ent5             U78C9.001.WZS0TLH-P1-C10-T2                                   PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)
+ ent6             U78C9.001.WZS0TLH-P1-C10-T3                                   PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)
+ ent7             U78C9.001.WZS0TLH-P1-C10-T4                                   PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)
* pci7             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci6             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci5             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ usbhc0           U78C9.001.WZS0TLH-P1                                          Integrated USB 3.0 
xHCI Adapter (4c1041821410b204)
* pci4             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ ent0             U78C9.001.WZS0TLH-P1-C6-T1                                    PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)
+ ent1             U78C9.001.WZS0TLH-P1-C6-T2                                    PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)
+ ent2             U78C9.001.WZS0TLH-P1-C6-T3                                    PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)
+ ent3             U78C9.001.WZS0TLH-P1-C6-T4                                    PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)
* pci3             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ sissas0          U78C9.001.WZS0TLH-P1-C14-T1                                   PCIe3 x8 SAS RAID 
Internal Adapter 6Gb
* sas0             U78C9.001.WZS0TLH-P1-C14-T1                                   Controller SAS 
Protocol
* sfwcomm4                                                                       SAS Storage Framework 
Comm
+ hdisk0           U78C9.001.WZS0TLH-P2-D7                                       SAS 4K Disk Drive 
(600000 MB)
+ ses0             U78C9.001.WZS0TLH-P2-Y1                                       SAS Enclosure Services 
Device
* sata0            U78C9.001.WZS0TLH-P1-C14-T1                                   Controller SATA 
Protocol
+ cd0              U78C9.001.WZS0TLH-P2-D27                                      SATA DVD-RAM Drive
* pci2             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci1             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci0             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ fcs0             U78C9.001.WZS0TLH-P1-C7-T1                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)
* fscsi0           U78C9.001.WZS0TLH-P1-C7-T1                                    FC SCSI I/O Controller 
Protocol Device
* pdisk0           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk2           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L20000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk1           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk3           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L10000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk2           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk4           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L22000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk3           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk5           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L12000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk4           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk6           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk5           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk7           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L24000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk6           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk8           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L14000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk7           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk9           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L4000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk8           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk10          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L26000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk9           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk11          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L16000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk10          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk12          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L6000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk11          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk13          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L28000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk12          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk14          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L18000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk13          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk15          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L8000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk14          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk16          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2A000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk15          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk17          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1A000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk16          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk18          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LA000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk17          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk19          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2C000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk18          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk20          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1C000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk19          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk21          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LC000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk20          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk22          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1E000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk21          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk23          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LE000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk22          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk23          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk24          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk25          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk26          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk27          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk28          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk29          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk30          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk31          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk32          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk33          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk34          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk35          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk36          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk37          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk38          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk39          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk40          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk41          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk42          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk43          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk44          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk24          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L21000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk45          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk25          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L11000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk46          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk26          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk47          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk27          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L23000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk48          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk28          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L13000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk49          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk29          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L3000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk50          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk30          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L25000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk51          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk31          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L15000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk52          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk32          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L5000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk53          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk33          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L27000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk54          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk34          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L17000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk55          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk35          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L7000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk56          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk36          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L29000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk57          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk37          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L19000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk58          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk38          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L9000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk59          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk39          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2B000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk60          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk40          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1B000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk61          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk41          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LB000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk62          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk42          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2D000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk63          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk43          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1D000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk64          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk44          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LD000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk65          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk45          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1F000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk66          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk46          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LF000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk67          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk68          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk69          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk70          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk71          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk72          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk73          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk74          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk75          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk76          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk77          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk78          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk79          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk80          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk81          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk82          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk83          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk84          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk85          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk86          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk87          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk88          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk89          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk360         U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk47          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2E000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk361         U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* sfwcomm0         U78C9.001.WZS0TLH-P1-C7-T1-W0-L0                              Fibre Channel Storage 
Framework Comm
+ fcs1             U78C9.001.WZS0TLH-P1-C7-T2                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)
* fscsi1           U78C9.001.WZS0TLH-P1-C7-T2                                    FC SCSI I/O Controller 
Protocol Device
* pdisk90          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk91          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk92          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk93          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk94          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk95          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk96          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk97          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk98          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk99          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk100         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk101         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk102         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk103         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk104         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk105         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk106         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk107         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk108         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk109         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk110         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk111         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk112         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk113         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk114         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk115         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk116         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk117         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk118         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk119         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk120         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk121         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk122         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk123         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk124         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk125         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk126         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk127         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk128         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk129         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk130         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk131         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk132         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk133         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk134         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk135         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk136         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk137         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk138         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk139         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk140         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk141         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk142         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk143         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk144         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk145         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk146         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk147         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk148         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk149         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk150         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk151         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk152         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk153         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk154         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk155         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk156         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk157         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk158         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk159         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk160         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk161         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk162         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk163         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk164         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk165         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk166         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk167         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk168         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk169         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk170         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk171         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk172         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk173         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk174         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk175         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk176         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk177         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk178         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk179         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk362         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk363         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* sfwcomm1         U78C9.001.WZS0TLH-P1-C7-T2-W0-L0                              Fibre Channel Storage 
Framework Comm
+ L2cache0                                                                       L2 Cache
+ mem0                                                                           Memory
+ proc0                                                                          Processor
+ proc8                                                                          Processor
+ proc104                                                                        Processor
+ proc112                                                                        Processor
+ proc120                                                                        Processor
+ proc128                                                                        Processor
+ proc136                                                                        Processor
+ proc144                                                                        Processor
+ proc152                                                                        Processor
+ proc16                                                                         Processor
+ proc160                                                                        Processor
+ proc168                                                                        Processor
+ proc176                                                                        Processor
+ proc184                                                                        Processor
+ proc24                                                                         Processor
+ proc32                                                                         Processor
+ proc40                                                                         Processor
+ proc48                                                                         Processor
+ proc56                                                                         Processor
+ proc64                                                                         Processor
+ proc72                                                                         Processor
+ proc80                                                                         Processor
+ proc88                                                                         Processor
+ proc96                                                                         Processor

2017-05-26 07:40:25: Check checklscfg.ksh completed successfully: returncode 0
2017-05-26 07:40:25: Runtime: 1 second(s)
2017-05-26 07:40:25: 45% complete - 123 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:25: Running check script 102 of 224: checklscfgvp.ksh

Description:
------------

Runs lscfg with the -v and -p options to display the platform and VPD information.

To run this yourself:

# lscfg -vp

Output:
------------

INSTALLED RESOURCE LIST WITH VPD

The following resources are installed on your machine.
	
  Model Architecture: chrp
  Model Implementation: Multiple Processor, PCI bus

  sys0                                                                           System Object
  sysplanar0                                                                     System Planar
  vio0                                                                           Virtual I/O Bus
  vsa0             U8286.42A.21C096X-V1-C0                                       LPAR Virtual Serial 
Adapter

        Hardware Location Code......U8286.42A.21C096X-V1-C0

  vty0             U8286.42A.21C096X-V1-C0-L0                                    Asynchronous Terminal
  pci13            U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  fcs2             U78C9.001.WZS0TLH-P1-C3-T1                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)

        Part Number.................00E3495
        EC Level....................D77535
        Customer Card ID Number.....577F
        Manufacturer................001A
        FRU Number..................00E3496
        Device Specific.(ZM)........3
        ROM Level.(alterable).......100300
        Network Address.............10000088ADF497D0
        Device Specific.(Z0)........0000000B
        Device Specific.(Z1)........00000030
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........08090000
        Device Specific.(Z4)........01000001
        Device Specific.(Z5)........2E323532
        Device Specific.(Z6)........2E323532
        Device Specific.(Z7)........C0022B40
        Device Specific.(Z8)........20000088ADF497D0
        Device Specific.(Z9)........10.2.252.1919
        Device Specific.(ZA)........10.2.252.1919
        Device Specific.(ZB)........00000000
        Device Specific.(ZC)........00040000
        Device Specific.(ZD)........000000FF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C3-T1

  fscsi2           U78C9.001.WZS0TLH-P1-C3-T1                                    FC SCSI I/O Controller 
Protocol Device
  pdisk180         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk181         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk182         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk183         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk184         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk185         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk186         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk187         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk188         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk189         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk190         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk191         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk192         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk193         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk194         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk195         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk196         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk197         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk198         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk199         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk200         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk201         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk202         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk203         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk204         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk205         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk206         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk207         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk208         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk209         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk210         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk211         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk212         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk213         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk214         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk215         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk216         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk217         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk218         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk219         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk220         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk221         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk222         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk223         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk224         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk225         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk226         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk227         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk228         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk229         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk230         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk231         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk232         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk233         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk234         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk235         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk236         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk237         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk238         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk239         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk240         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk241         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk242         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk243         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk244         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk245         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk246         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk247         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk248         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk249         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk250         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk251         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk252         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk253         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk254         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk255         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk256         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk257         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk258         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk259         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk260         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk261         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk262         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk263         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk264         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk265         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk266         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk267         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk268         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk269         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk364         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk365         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
  sfwcomm2         U78C9.001.WZS0TLH-P1-C3-T1-W0-L0                              Fibre Channel Storage 
Framework Comm
  fcs3             U78C9.001.WZS0TLH-P1-C3-T2                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)

        Part Number.................00E3495
        EC Level....................D77535
        Customer Card ID Number.....577F
        Manufacturer................001A
        FRU Number..................00E3496
        Device Specific.(ZM)........3
        ROM Level.(alterable).......100300
        Network Address.............10000088ADF497D1
        Device Specific.(Z0)........0000000B
        Device Specific.(Z1)........00000030
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........08090000
        Device Specific.(Z4)........01010001
        Device Specific.(Z5)........2E323532
        Device Specific.(Z6)........2E323532
        Device Specific.(Z7)........C0022B40
        Device Specific.(Z8)........20000088ADF497D1
        Device Specific.(Z9)........10.2.252.1919
        Device Specific.(ZA)........10.2.252.1919
        Device Specific.(ZB)........00000000
        Device Specific.(ZC)........00040000
        Device Specific.(ZD)........000000FF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C3-T2

  fscsi3           U78C9.001.WZS0TLH-P1-C3-T2                                    FC SCSI I/O Controller 
Protocol Device
  pdisk270         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk271         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk272         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk273         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk274         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk275         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk276         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk277         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk278         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk279         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk280         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk281         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk282         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk283         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk284         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk285         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk286         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk287         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk288         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk289         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk290         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk291         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk292         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk293         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk294         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk295         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk296         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk297         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk298         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk299         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk300         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk301         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk302         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk303         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk304         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk305         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk306         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk307         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk308         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk309         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk310         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk311         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk312         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk313         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk314         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk315         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk316         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk317         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk318         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk319         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk320         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk321         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk322         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk323         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk324         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk325         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk326         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk327         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk328         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk329         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk330         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk331         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk332         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk333         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk334         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk335         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk336         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk337         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk338         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk339         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk340         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk341         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk342         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk343         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk344         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk345         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk346         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk347         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk348         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk349         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk350         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk351         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk352         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk353         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk354         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk355         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk356         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk357         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk358         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk359         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk366         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk367         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
  sfwcomm3         U78C9.001.WZS0TLH-P1-C3-T2-W0-L0                              Fibre Channel Storage 
Framework Comm
  pci12            U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  pci11            U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  pci10            U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  pci9             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  sissas1          U78C9.001.WZS0TLH-P1-C15-T1                                   PCIe3 x8 SAS RAID 
Internal Adapter 6Gb

        Hardware Location Code......U78C9.001.WZS0TLH-P1-C15-T1

  sas1             U78C9.001.WZS0TLH-P1-C15-T1                                   Controller SAS 
Protocol
  sfwcomm5                                                                       SAS Storage Framework 
Comm
  hdisk1           U78C9.001.WZS0TLH-P2-D1                                       SAS 4K Disk Drive 
(600000 MB)

        Manufacturer................IBM     
        Machine Type and Model......HUC101860CS420  
        FRU Number..................00E9959     
        ROS Level and ID............4E393930
        EC Level....................N46243    
        Part Number.................00E9955     
        Device Specific.(Z0)........000006329F001002
        Device Specific.(Z1)........C4IPN990    
        Device Specific.(Z2)........0068
        Device Specific.(Z3)........16198
        Device Specific.(Z4)........
        Device Specific.(Z5)........22
        Device Specific.(Z6)........N46243    
        Hardware Location Code......U78C9.001.WZS0TLH-P2-D1

  ses1             U78C9.001.WZS0TLH-P2-Y1                                       SAS Enclosure Services 
Device

        ROM Level.(alterable).......  03
        Hardware Location Code......U78C9.001.WZS0TLH-P2-Y1

  sata1            U78C9.001.WZS0TLH-P1-C15-T1                                   Controller SATA 
Protocol
  pci8             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  ent4             U78C9.001.WZS0TLH-P1-C10-T1                                   PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)

      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94688C3C
        Network Address.............98BE94688C3C
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C10-T1

  ent5             U78C9.001.WZS0TLH-P1-C10-T2                                   PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)

      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94688C3C
        Network Address.............98BE94688C3D
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C10-T2

  ent6             U78C9.001.WZS0TLH-P1-C10-T3                                   PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)

      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94688C3C
        Network Address.............98BE94688C3E
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C10-T3

  ent7             U78C9.001.WZS0TLH-P1-C10-T4                                   PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)

      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94688C3C
        Network Address.............98BE94688C3F
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C10-T4

  pci7             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  pci6             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  pci5             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  usbhc0           U78C9.001.WZS0TLH-P1                                          Integrated USB 3.0 
xHCI Adapter (4c1041821410b204)

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  pci4             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  ent0             U78C9.001.WZS0TLH-P1-C6-T1                                    PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)

      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94689598
        Network Address.............98BE94689598
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C6-T1

  ent1             U78C9.001.WZS0TLH-P1-C6-T2                                    PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)

      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94689598
        Network Address.............98BE94689599
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C6-T2

  ent2             U78C9.001.WZS0TLH-P1-C6-T3                                    PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)

      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94689598
        Network Address.............98BE9468959A
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C6-T3

  ent3             U78C9.001.WZS0TLH-P1-C6-T4                                    PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)

      PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter:
        FRU Number..................00E2715
        EC Level....................D77452
        Customer Card ID Number.....2CC3
        Part Number.................00E2719
        Feature Code/Marketing ID...EN0S
        Manufacture ID..............98BE94689598
        Network Address.............98BE9468959B
        ROM Level.(alterable).......30100150
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C6-T4

  pci3             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  sissas0          U78C9.001.WZS0TLH-P1-C14-T1                                   PCIe3 x8 SAS RAID 
Internal Adapter 6Gb

        Hardware Location Code......U78C9.001.WZS0TLH-P1-C14-T1

  sas0             U78C9.001.WZS0TLH-P1-C14-T1                                   Controller SAS 
Protocol
  sfwcomm4                                                                       SAS Storage Framework 
Comm
  hdisk0           U78C9.001.WZS0TLH-P2-D7                                       SAS 4K Disk Drive 
(600000 MB)

        Manufacturer................IBM     
        Machine Type and Model......HUC101860CS420  
        FRU Number..................00E9959     
        ROS Level and ID............4E393930
        EC Level....................N46243    
        Part Number.................00E9955     
        Device Specific.(Z0)........000006329F001002
        Device Specific.(Z1)........C4IPN990    
        Device Specific.(Z2)........0068
        Device Specific.(Z3)........15003
        Device Specific.(Z4)........
        Device Specific.(Z5)........22
        Device Specific.(Z6)........N46243    
        Hardware Location Code......U78C9.001.WZS0TLH-P2-D7

  ses0             U78C9.001.WZS0TLH-P2-Y1                                       SAS Enclosure Services 
Device

        ROM Level.(alterable).......  03
        Hardware Location Code......U78C9.001.WZS0TLH-P2-Y1

  sata0            U78C9.001.WZS0TLH-P1-C14-T1                                   Controller SATA 
Protocol
  cd0              U78C9.001.WZS0TLH-P2-D27                                      SATA DVD-RAM Drive

        Manufacturer................IBM.    
        Machine Type and Model......RMBO0140572     
        ROS Level and ID............IP02
        Device Specific.(Z0)........058000325B000000
        Part Number.................00RW615     
        EC Level....................N99024    
        FRU Number..................00RW611     
        Hardware Location Code......U78C9.001.WZS0TLH-P2-D27

  pci2             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  pci1             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  pci0             U78C9.001.WZS0TLH-P1                                          PCI Express Bus

        Hardware Location Code......U78C9.001.WZS0TLH-P1

  fcs0             U78C9.001.WZS0TLH-P1-C7-T1                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)

        Part Number.................00E3495
        EC Level....................D77535
        Customer Card ID Number.....577F
        Manufacturer................001A
        FRU Number..................00E3496
        Device Specific.(ZM)........3
        ROM Level.(alterable).......100300
        Network Address.............10000088ADF49803
        Device Specific.(Z0)........0000000B
        Device Specific.(Z1)........00000030
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........08090000
        Device Specific.(Z4)........01000001
        Device Specific.(Z5)........2E323532
        Device Specific.(Z6)........2E323532
        Device Specific.(Z7)........C0022B40
        Device Specific.(Z8)........20000088ADF49803
        Device Specific.(Z9)........10.2.252.1919
        Device Specific.(ZA)........10.2.252.1919
        Device Specific.(ZB)........00000000
        Device Specific.(ZC)........00040000
        Device Specific.(ZD)........000000FF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C7-T1

  fscsi0           U78C9.001.WZS0TLH-P1-C7-T1                                    FC SCSI I/O Controller 
Protocol Device
  pdisk0           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk2           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L20000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000023
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:33
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS10

  pdisk1           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk3           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L10000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000013
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:17
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db10

  pdisk2           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk4           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L22000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000025
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:35
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS12

  pdisk3           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk5           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L12000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000015
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:19
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db12

  pdisk4           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk6           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000004
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:2
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:CLrep2

  pdisk5           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk7           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L24000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000027
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:37
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS14

  pdisk6           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk8           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L14000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000017
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:21
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_dbbkp02

  pdisk7           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk9           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L4000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000009
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:7
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_apps

  pdisk8           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk10          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L26000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000029
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:39
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS16

  pdisk9           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk11          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L16000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000019
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:23
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_dbbkp04

  pdisk10          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk12          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L6000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000006
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:4
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_archlog2

  pdisk11          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk13          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L28000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000002b
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:41
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS18

  pdisk12          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk14          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L18000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000001b
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:25
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS02

  pdisk13          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk15          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L8000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000000b
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:9
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db02

  pdisk14          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk16          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2A000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000002d
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:43
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS20

  pdisk15          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk17          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1A000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000001d
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:27
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS04

  pdisk16          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk18          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LA000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000000d
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:11
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db04

  pdisk17          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk19          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2C000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000002f
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:45
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS22

  pdisk18          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk20          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1C000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000001f
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:29
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS06

  pdisk19          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk21          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LC000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000000f
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:13
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db06

  pdisk20          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk22          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1E000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000021
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:31
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS08

  pdisk21          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk23          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LE000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000011
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:15
        Device Specific.(Z4)........CID:59637
        Device Specific.(Z5)........ETH0IP:ad180539
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db08

  pdisk22          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk23          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk24          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk25          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk26          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk27          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk28          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk29          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk30          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk31          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk32          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk33          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk34          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk35          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk36          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk37          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk38          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk39          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk40          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk41          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk42          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk43          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk44          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk24          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L21000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000024
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:34
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS11

  pdisk45          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk25          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L11000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000014
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:18
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db11

  pdisk46          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk26          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000003
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:1
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:CLrep1

  pdisk47          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk27          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L23000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000026
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:36
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS13

  pdisk48          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk28          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L13000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000016
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:20
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_dbbkp01

  pdisk49          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk29          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L3000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000000a
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:8
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_actlog

  pdisk50          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk30          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L25000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000028
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:38
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS15

  pdisk51          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk31          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L15000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000018
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:22
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_dbbkp03

  pdisk52          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk32          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L5000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000005
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:3
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_archlog1

  pdisk53          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk33          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L27000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000002a
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:40
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS17

  pdisk54          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk34          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L17000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000001a
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:24
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS01

  pdisk55          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk35          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L7000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000008
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:6
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db01

  pdisk56          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk36          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L29000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000002c
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:42
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS19

  pdisk57          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk37          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L19000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000001c
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:26
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS03

  pdisk58          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk38          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L9000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000000c
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:10
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db03

  pdisk59          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk39          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2B000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000002e
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:44
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS21

  pdisk60          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk40          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1B000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000001e
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:28
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS05

  pdisk61          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk41          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LB000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-0000000e
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:12
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db05

  pdisk62          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk42          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2D000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000007
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:5
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_recovery

  pdisk63          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk43          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1D000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000020
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:30
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS07

  pdisk64          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk44          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LD000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000010
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:14
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db07

  pdisk65          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk45          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1F000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000022
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:32
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_FS09

  pdisk66          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk46          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LF000000000000   MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000012
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:16
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:SP_db09

  pdisk67          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk68          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk69          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk70          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk71          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk72          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk73          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk74          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk75          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk76          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk77          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk78          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk79          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk80          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk81          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk82          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk83          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk84          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk85          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk86          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk87          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk88          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk89          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  pdisk360         U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  hdisk47          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2E000000000000  MPIO Compellent Fibre 
Channel Disk Drive

        Manufacturer................COMPELNT
        Machine Type and Model......Compellent Vol 
        ROS Level and ID............0607
        Device Specific.(Z0)........00000532FA181002
        Device Specific.(Z1)........0000e8f4-00000030
        Device Specific.(Z2)........SSN:87390
        Device Specific.(Z3)........IND:46
        Device Specific.(Z4)........CID:87390
        Device Specific.(Z5)........ETH0IP:ad18053a
        Device Specific.(Z6)........MIP:ad18053b
        Device Specific.(Z7)........SysName:DTC-GRT-CML01-87390
        Device Specific.(Z8)........VolName:tsmhome

  pdisk361         U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
  sfwcomm0         U78C9.001.WZS0TLH-P1-C7-T1-W0-L0                              Fibre Channel Storage 
Framework Comm
  fcs1             U78C9.001.WZS0TLH-P1-C7-T2                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)

        Part Number.................00E3495
        EC Level....................D77535
        Customer Card ID Number.....577F
        Manufacturer................001A
        FRU Number..................00E3496
        Device Specific.(ZM)........3
        ROM Level.(alterable).......100300
        Network Address.............10000088ADF49804
        Device Specific.(Z0)........0000000B
        Device Specific.(Z1)........00000030
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........08090000
        Device Specific.(Z4)........01010001
        Device Specific.(Z5)........2E323532
        Device Specific.(Z6)........2E323532
        Device Specific.(Z7)........C0022B40
        Device Specific.(Z8)........20000088ADF49804
        Device Specific.(Z9)........10.2.252.1919
        Device Specific.(ZA)........10.2.252.1919
        Device Specific.(ZB)........00000000
        Device Specific.(ZC)........00040000
        Device Specific.(ZD)........000000FF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C7-T2

  fscsi1           U78C9.001.WZS0TLH-P1-C7-T2                                    FC SCSI I/O Controller 
Protocol Device
  pdisk90          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk91          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk92          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk93          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk94          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk95          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk96          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk97          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk98          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk99          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk100         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk101         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk102         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk103         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk104         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk105         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk106         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk107         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk108         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk109         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk110         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk111         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk112         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk113         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk114         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk115         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk116         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk117         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk118         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk119         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk120         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk121         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk122         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk123         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk124         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk125         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk126         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk127         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk128         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk129         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk130         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk131         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk132         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk133         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk134         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk135         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk136         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk137         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk138         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk139         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk140         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk141         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk142         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk143         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk144         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk145         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk146         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk147         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk148         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk149         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk150         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk151         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk152         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk153         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk154         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk155         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk156         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk157         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk158         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk159         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk160         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk161         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk162         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk163         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk164         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk165         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk166         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk167         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk168         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk169         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk170         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk171         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk172         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk173         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk174         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk175         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk176         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk177         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk178         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk179         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk362         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  pdisk363         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
  sfwcomm1         U78C9.001.WZS0TLH-P1-C7-T2-W0-L0                              Fibre Channel Storage 
Framework Comm
  L2cache0                                                                       L2 Cache
  mem0                                                                           Memory
  proc0                                                                          Processor
  proc8                                                                          Processor
  proc104                                                                        Processor
  proc112                                                                        Processor
  proc120                                                                        Processor
  proc128                                                                        Processor
  proc136                                                                        Processor
  proc144                                                                        Processor
  proc152                                                                        Processor
  proc16                                                                         Processor
  proc160                                                                        Processor
  proc168                                                                        Processor
  proc176                                                                        Processor
  proc184                                                                        Processor
  proc24                                                                         Processor
  proc32                                                                         Processor
  proc40                                                                         Processor
  proc48                                                                         Processor
  proc56                                                                         Processor
  proc64                                                                         Processor
  proc72                                                                         Processor
  proc80                                                                         Processor
  proc88                                                                         Processor
  proc96                                                                         Processor

  PLATFORM SPECIFIC

  Name:  IBM,8286-42A
    Model:  IBM,8286-42A
    Node:  /
    Device Type:  chrp

      System VPD:
        Record Name.................VSYS
        Flag Field..................XXSV
        Brand.......................S0
        Hardware Location Code......U8286.42A.21C096X
        Machine/Cabinet Serial No...21C096X
        Machine Type and Model......8286-42A
        System Unique ID (SUID).....0004AC1D6A50
        World Wide Port Name........C05076763X3V
        Product Specific.(FV).......SV840_139
        Version.....................ipzSeries
      Physical Location: U8286.42A.21C096X

      CEC:
        Record Name.................VCEN
        Flag Field..................XXEV
        Brand.......................S0
        Hardware Location Code......U78C9.001.WZS0TLH
        Machine/Cabinet Serial No...WZG0SLH
        Machine Type and Model......78C9-001
        Controlling CEC ID..........8286-42A 21C096X
        Rack Serial Number..........0000000000000000
        Feature Code/Marketing ID...78C9-001
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH

      I/O BACKPLANE   :
        Record Name.................VINI
        Flag Field..................XXBP
        Hardware Location Code......U78C9.001.WZS0TLH-P1
        Customer Card ID Number.....2CD4
        CCIN Extender...............1
        Product Specific.(VZ).......01
        FRU Number..................01DH349
        Part Number.................01DH347
        Power.......................2100000000000000
        Product Specific.(HE).......0002
        Product Specific.(CT).......80F30026
        Product Specific.(HW).......0006
        Product Specific.(B3).......000000000001
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1

      NATIVE I/O CARD :
        Record Name.................VINI
        Flag Field..................XXBX
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C1
        Customer Card ID Number.....2B0B
        CCIN Extender...............1
        Product Specific.(VZ).......01
        FRU Number..................00E1960
        Part Number.................00E3809
        Product Specific.(HE).......0001
        Product Specific.(CT).......80B50000
        Product Specific.(HW).......0001
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C1

      ANCHOR          :
        Record Name.................VINI
        Flag Field..................XXAV
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C13
        Customer Card ID Number.....52FE
        CCIN Extender...............1
        Product Specific.(VZ).......01
        FRU Number..................00E2147
        Part Number.................00E2148
        Power.......................8100300000000000
        Product Specific.(HE).......0010
        Product Specific.(CT).......40B40000
        Product Specific.(HW).......0001
        Product Specific.(B3).......000000000001
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Product Specific.(B9).......435362851137062A2E485350FA3DEAB0D290BFCC4D
                                    3109B81194CFDCD1F14D32C602CFABA0D9F4114D33
                                    C4E294CE10C773794D342E54079E96FEDC6C
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C13

      Memory DIMM:
        Record Name.................VINI
        Flag Field..................XXMS
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C16
        Customer Card ID Number.....31E9
        CCIN Extender...............1
        Product Specific.(VZ).......17
        FRU Number..................00LP740
        Part Number.................00LP740
        Power.......................4900000000010000
        Size........................0032768
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0100
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C16

      Memory DIMM:
        Record Name.................VINI
        Flag Field..................XXMS
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C18
        Customer Card ID Number.....31E9
        CCIN Extender...............1
        Product Specific.(VZ).......17
        FRU Number..................00LP740
        Part Number.................00LP740
        Power.......................4900000000010000
        Size........................0032768
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0100
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C18

      Memory DIMM:
        Record Name.................VINI
        Flag Field..................XXMS
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C21
        Customer Card ID Number.....31E9
        CCIN Extender...............1
        Product Specific.(VZ).......17
        FRU Number..................00LP740
        Part Number.................00LP740
        Power.......................4900000000010000
        Size........................0032768
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0100
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C21

      Memory DIMM:
        Record Name.................VINI
        Flag Field..................XXMS
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C23
        Customer Card ID Number.....31E9
        CCIN Extender...............1
        Product Specific.(VZ).......17
        FRU Number..................00LP740
        Part Number.................00LP740
        Power.......................4900000000010000
        Size........................0032768
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0100
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C23

      Memory DIMM:
        Record Name.................VINI
        Flag Field..................XXMS
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C24
        Customer Card ID Number.....31E9
        CCIN Extender...............1
        Product Specific.(VZ).......17
        FRU Number..................00LP740
        Part Number.................00LP740
        Power.......................4900000000010000
        Size........................0032768
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0100
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C24

      Memory DIMM:
        Record Name.................VINI
        Flag Field..................XXMS
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C26
        Customer Card ID Number.....31E9
        CCIN Extender...............1
        Product Specific.(VZ).......17
        FRU Number..................00LP740
        Part Number.................00LP740
        Power.......................4900000000010000
        Size........................0032768
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0100
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C26

      Memory DIMM:
        Record Name.................VINI
        Flag Field..................XXMS
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C29
        Customer Card ID Number.....31E9
        CCIN Extender...............1
        Product Specific.(VZ).......17
        FRU Number..................00LP740
        Part Number.................00LP740
        Power.......................4900000000010000
        Size........................0032768
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0100
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C29

      Memory DIMM:
        Record Name.................VINI
        Flag Field..................XXMS
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C31
        Customer Card ID Number.....31E9
        CCIN Extender...............1
        Product Specific.(VZ).......17
        FRU Number..................00LP740
        Part Number.................00LP740
        Power.......................4900000000010000
        Size........................0032768
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0100
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C31

      12-WAY PROC CUOD:
        Record Name.................VINI
        Flag Field..................XXPF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C32
        Customer Card ID Number.....54E3
        FRU Number..................00FX516
        Part Number.................00FX736
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0001
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Power.......................3500600111008001
        Product Specific.(VZ).......01
        CCIN Extender...............1
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C32

      12-WAY PROC CUOD:
        Record Name.................VINI
        Flag Field..................XXPF
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C33
        Customer Card ID Number.....54E3
        FRU Number..................00FX516
        Part Number.................00FX736
        Product Specific.(HE).......0001
        Product Specific.(CT).......00000000
        Product Specific.(HW).......0001
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Power.......................3500600111008001
        Product Specific.(VZ).......01
        CCIN Extender...............1
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-P1-C33

      CEC OP PANEL    :
        Record Name.................VINI
        Flag Field..................XXOP
        Hardware Location Code......U78C9.001.WZS0TLH-D1
        Customer Card ID Number.....2B08
        CCIN Extender...............1
        Product Specific.(VZ).......02
        FRU Number..................00RR573
        Part Number.................00RR578
        Product Specific.(HE).......0001
        Product Specific.(CT).......80B50000
        Product Specific.(HW).......0003
        Product Specific.(B3).......000000000000
        Product Specific.(B4).......00
        Product Specific.(B7).......000000000000000000000000
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-D1

      IBM PS         :
        Record Name.................VINI
        Flag Field..................XXPS
        Hardware Location Code......U78C9.001.WZS0TLH-E1
        Customer Card ID Number.....2B1D
        Power Resource ID...........
        FRU Number.................. 01AF895
        Part Number.................01AF895
        FRU Label...................E1
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-E1

      IBM PS         :
        Record Name.................VINI
        Flag Field..................XXPS
        Hardware Location Code......U78C9.001.WZS0TLH-E2
        Customer Card ID Number.....2B1D
        Power Resource ID...........
        FRU Number.................. 01AF895
        Part Number.................01AF895
        FRU Label...................E2
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-E2

      IBM PS         :
        Record Name.................VINI
        Flag Field..................XXPS
        Hardware Location Code......U78C9.001.WZS0TLH-E3
        Customer Card ID Number.....2B1D
        Power Resource ID...........
        FRU Number.................. 01AF895
        Part Number.................01AF895
        FRU Label...................E3
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-E3

      IBM PS         :
        Record Name.................VINI
        Flag Field..................XXPS
        Hardware Location Code......U78C9.001.WZS0TLH-E4
        Customer Card ID Number.....2B1D
        Power Resource ID...........
        FRU Number.................. 01AF895
        Part Number.................01AF895
        FRU Label...................E4
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-E4

      4U 80MM CR FAN  :
        Record Name.................VINI
        Flag Field..................XXAM
        Hardware Location Code......U78C9.001.WZS0TLH-A1
        Customer Card ID Number.....2B1F
        Part Number.................00FV629
        Power Resource ID...........
        FRU Number..................00FV629
        FRU Label...................A1                  
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-A1

      4U 80MM CR FAN  :
        Record Name.................VINI
        Flag Field..................XXAM
        Hardware Location Code......U78C9.001.WZS0TLH-A2
        Customer Card ID Number.....2B1F
        Part Number.................00FV629
        Power Resource ID...........
        FRU Number..................00FV629
        FRU Label...................A2                  
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-A2

      4U 80MM CR FAN  :
        Record Name.................VINI
        Flag Field..................XXAM
        Hardware Location Code......U78C9.001.WZS0TLH-A3
        Customer Card ID Number.....2B1F
        Part Number.................00FV629
        Power Resource ID...........
        FRU Number..................00FV629
        FRU Label...................A3                  
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-A3

      4U 80MM CR FAN  :
        Record Name.................VINI
        Flag Field..................XXAM
        Hardware Location Code......U78C9.001.WZS0TLH-A4
        Customer Card ID Number.....2B1F
        Part Number.................00FV629
        Power Resource ID...........
        FRU Number..................00FV629
        FRU Label...................A4                  
        Version.....................ipzSeries
      Physical Location: U78C9.001.WZS0TLH-A4

      VSBPD12M1 6GSAS :
        Record Name.................VINI
        Flag Field..................XXDB
        Hardware Location Code......U78C9.001.WZS0TLH-P2
        Customer Card ID Number.....2B09
        FRU Number.................. 01DH345
        Part Number.................01DH343
        CCIN Extender...............3
        Product Specific.(VZ).......03
        Product Specific.(B2).......500507606BEBAE000000000000000100
        Product Specific.(WI).......
        Version.....................RS6K
      Physical Location: U78C9.001.WZS0TLH-P2

      System Firmware:
        Code Level, LID Keyword.....Phyp_1 14502017030180A00701
        Code Level, LID Keyword.....PFW 00302017030381CF0681
        Code Level, LID Keyword.....FSP_Fil 15082017031281E00109
        Code Level, LID Keyword.....FipS_BU 15082017031281E00208
        Microcode Image.............SV860_082 SV860_082 SV860_082
        Microcode Level.............FW860.20 FW860.20 FW860.20
        Microcode Build Date........20170317 20170317 20170317
        Microcode Entitlement Date..20191221
        Hardware Location Code......U8286.42A.21C096X-Y1
      Physical Location: U8286.42A.21C096X-Y1

  Name:  openprom
    Model:  IBM,FW860.20 (SV860_082)
    Node:  openprom

  Name:  interrupt-controller
    Model:  IBM, Logical PowerPC-PIC, 00
    Node:  interrupt-controller@0
    Device Type:  PowerPC-External-Interrupt-Presentation

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000010
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000013
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000014
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000015
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000018
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@80000002500001b
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@80000002500001c
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@80000002500001d
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@80000002500001e
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@80000002500001f
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000020
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000021
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000028
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  interrupt-controller
    Model:  IBM,Logical PHB
    Node:  interrupt-controller@800000025000029
    Device Type:  PowerPC-LSI-Source
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000010
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000013
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000014
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000015
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000018
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@80000002000001b
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@80000002000001c
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@80000002000001d
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@80000002000001e
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@80000002000001f
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000020
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000021
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000028
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  pci
    Model:  IBM,Logical_PHB
    Node:  pci@800000020000029
    Device Type:  pciex
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  vty
    Node:  vty@30000000
    Device Type:  serial
    Physical Location: U8286.42A.21C096X-V1-C0

  Name:  fibre-channel
    Model:  00E3495
    Node:  fibre-channel@0
    Device Type:  fcp
    Physical Location: U78C9.001.WZS0TLH-P1-C7-T1

  Name:  fibre-channel
    Model:  00E3495
    Node:  fibre-channel@0,1
    Device Type:  fcp
    Physical Location: U78C9.001.WZS0TLH-P1-C7-T2

  Name:  pci1014,034A
    Node:  pci1014,034A@0
    Physical Location: U78C9.001.WZS0TLH-P1-C14-T1

      PCIe3 x8 Internal SAS Adapter 6Gb               :
        Part Number.................01DH551
        FRU Number..................01DH550
        Manufacture ID..............00UE
        EC Level....................0
        ROM Level.(alterable).......15511800
        Customer Card ID Number.....57D7
        Product Specific.(Z1).......1
        Product Specific.(Z2).......2D35
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C14-T1

  Name:  ethernet
    Node:  ethernet@0
    Device Type:  network
    Physical Location: U78C9.001.WZS0TLH-P1-C6-T1

  Name:  ethernet
    Node:  ethernet@0,1
    Device Type:  network
    Physical Location: U78C9.001.WZS0TLH-P1-C6-T2

  Name:  ethernet
    Node:  ethernet@0,2
    Device Type:  network
    Physical Location: U78C9.001.WZS0TLH-P1-C6-T3

  Name:  ethernet
    Node:  ethernet@0,3
    Device Type:  network
    Physical Location: U78C9.001.WZS0TLH-P1-C6-T4

  Name:  usb
    Node:  usb@0
    Physical Location: U78C9.001.WZS0TLH-P1

  Name:  ethernet
    Node:  ethernet@0
    Device Type:  network
    Physical Location: U78C9.001.WZS0TLH-P1-C10-T1

  Name:  ethernet
    Node:  ethernet@0,1
    Device Type:  network
    Physical Location: U78C9.001.WZS0TLH-P1-C10-T2

  Name:  ethernet
    Node:  ethernet@0,2
    Device Type:  network
    Physical Location: U78C9.001.WZS0TLH-P1-C10-T3

  Name:  ethernet
    Node:  ethernet@0,3
    Device Type:  network
    Physical Location: U78C9.001.WZS0TLH-P1-C10-T4

  Name:  pci1014,034A
    Node:  pci1014,034A@0
    Physical Location: U78C9.001.WZS0TLH-P1-C15-T1

      PCIe3 x8 Internal SAS Adapter 6Gb               :
        Part Number.................01DH551
        FRU Number..................01DH550
        Manufacture ID..............00UE
        EC Level....................0
        ROM Level.(alterable).......15511800
        Customer Card ID Number.....57D7
        Product Specific.(Z1).......1
        Product Specific.(Z2).......2D35
        Hardware Location Code......U78C9.001.WZS0TLH-P1-C15-T1

  Name:  fibre-channel
    Model:  00E3495
    Node:  fibre-channel@0
    Device Type:  fcp
    Physical Location: U78C9.001.WZS0TLH-P1-C3-T1

  Name:  fibre-channel
    Model:  00E3495
    Node:  fibre-channel@0,1
    Device Type:  fcp
    Physical Location: U78C9.001.WZS0TLH-P1-C3-T2

  Name:  hub
    Node:  hub@1
    Physical Location: U78C9.001.WZS0TLH-P1

2017-05-26 07:40:26: Check checklscfgvp.ksh completed successfully: returncode 0
2017-05-26 07:40:26: Runtime: 1 second(s)
2017-05-26 07:40:27: 45% complete - 122 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:27: Running check script 103 of 224: checklsdev.ksh

Description:
------------

List all the configured devices on the system.

This check script runs the following command:

# /usr/sbin/lsdev -C

Output:
------------

L2cache0       Available             L2 Cache
caalv_private1 Defined               Logical volume
caalv_private2 Defined               Logical volume
caalv_private3 Defined               Logical volume
caavg_private  Defined               Volume group
cache0         Defined               SSD Cache virtual device
cd0            Available 03-00-00    SATA DVD-RAM Drive
cengine0       Defined               SSD Cache engine
cluster0       Available             Cluster Node
dumplv0        Defined               Logical volume
dumplv1        Defined               Logical volume
en0            Defined   04-00       Standard Ethernet Network Interface
en1            Defined   04-01       Standard Ethernet Network Interface
en2            Defined   04-02       Standard Ethernet Network Interface
en3            Defined   04-03       Standard Ethernet Network Interface
en4            Defined   08-00       Standard Ethernet Network Interface
en5            Defined   08-01       Standard Ethernet Network Interface
en6            Defined   08-02       Standard Ethernet Network Interface
en7            Defined   08-03       Standard Ethernet Network Interface
en8            Available             Standard Ethernet Network Interface
ent0           Available 04-00       PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
ent1           Available 04-01       PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
ent2           Available 04-02       PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
ent3           Available 04-03       PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
ent4           Available 08-00       PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
ent5           Available 08-01       PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
ent6           Available 08-02       PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
ent7           Available 08-03       PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
ent8           Available             EtherChannel / IEEE 802.3ad Link Aggregation
et0            Defined   04-00       IEEE 802.3 Ethernet Network Interface
et1            Defined   04-01       IEEE 802.3 Ethernet Network Interface
et2            Defined   04-02       IEEE 802.3 Ethernet Network Interface
et3            Defined   04-03       IEEE 802.3 Ethernet Network Interface
et4            Defined   08-00       IEEE 802.3 Ethernet Network Interface
et5            Defined   08-01       IEEE 802.3 Ethernet Network Interface
et6            Defined   08-02       IEEE 802.3 Ethernet Network Interface
et7            Defined   08-03       IEEE 802.3 Ethernet Network Interface
et8            Defined               IEEE 802.3 Ethernet Network Interface
exportlv       Available             Logical volume
fcs0           Available 00-00       PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
fcs1           Available 00-01       PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
fcs2           Available 0D-00       PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
fcs3           Available 0D-01       PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
fscsi0         Available 00-00-01    FC SCSI I/O Controller Protocol Device
fscsi1         Available 00-01-01    FC SCSI I/O Controller Protocol Device
fscsi2         Available 0D-00-01    FC SCSI I/O Controller Protocol Device
fscsi3         Available 0D-01-01    FC SCSI I/O Controller Protocol Device
hd1            Defined               Logical volume
hd2            Defined               Logical volume
hd3            Defined               Logical volume
hd4            Defined               Logical volume
hd5            Defined               Logical volume
hd6            Defined               Logical volume
hd8            Defined               Logical volume
hd10opt        Defined               Logical volume
hd11admin      Defined               Logical volume
hd9var         Defined               Logical volume
hdisk0         Available 03-00-00    SAS 4K Disk Drive
hdisk1         Available 09-00-00    SAS 4K Disk Drive
hdisk2         Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk3         Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk4         Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk5         Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk6         Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk7         Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk8         Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk9         Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk10        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk11        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk12        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk13        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk14        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk15        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk16        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk17        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk18        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk19        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk20        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk21        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk22        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk23        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk24        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk25        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk26        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk27        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk28        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk29        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk30        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk31        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk32        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk33        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk34        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk35        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk36        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk37        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk38        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk39        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk40        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk41        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk42        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk43        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk44        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk45        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk46        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
hdisk47        Available 00-00-01    MPIO Compellent Fibre Channel Disk Drive
inet0          Available             Internet Network Extension
iocp0          Available             I/O Completion Ports
iscsi0         Available             iSCSI Protocol Device
livedump       Defined               Logical volume
lo0            Available             Loopback Network Interface
loop0          Available             Loopback Device
loop1          Available             Loopback Device
lvdd           Available             LVM Device Driver
mem0           Available             Memory
mksysblv       Defined               Logical volume
pci0           Available             PCI Express Bus
pci1           Available             PCI Express Bus
pci2           Available             PCI Express Bus
pci3           Available             PCI Express Bus
pci4           Available             PCI Express Bus
pci5           Available             PCI Express Bus
pci6           Available             PCI Express Bus
pci7           Available             PCI Express Bus
pci8           Available             PCI Express Bus
pci9           Available             PCI Express Bus
pci10          Available             PCI Express Bus
pci11          Available             PCI Express Bus
pci12          Available             PCI Express Bus
pci13          Available             PCI Express Bus
pdisk0         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk1         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk2         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk3         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk4         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk5         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk6         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk7         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk8         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk9         Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk10        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk11        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk12        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk13        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk14        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk15        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk16        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk17        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk18        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk19        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk20        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk21        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk22        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk23        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk24        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk25        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk26        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk27        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk28        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk29        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk30        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk31        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk32        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk33        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk34        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk35        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk36        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk37        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk38        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk39        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk40        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk41        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk42        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk43        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk44        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk45        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk46        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk47        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk48        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk49        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk50        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk51        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk52        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk53        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk54        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk55        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk56        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk57        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk58        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk59        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk60        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk61        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk62        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk63        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk64        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk65        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk66        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk67        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk68        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk69        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk70        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk71        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk72        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk73        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk74        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk75        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk76        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk77        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk78        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk79        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk80        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk81        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk82        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk83        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk84        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk85        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk86        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk87        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk88        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk89        Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk90        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk91        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk92        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk93        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk94        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk95        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk96        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk97        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk98        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk99        Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk100       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk101       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk102       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk103       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk104       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk105       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk106       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk107       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk108       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk109       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk110       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk111       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk112       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk113       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk114       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk115       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk116       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk117       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk118       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk119       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk120       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk121       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk122       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk123       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk124       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk125       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk126       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk127       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk128       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk129       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk130       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk131       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk132       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk133       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk134       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk135       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk136       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk137       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk138       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk139       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk140       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk141       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk142       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk143       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk144       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk145       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk146       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk147       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk148       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk149       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk150       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk151       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk152       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk153       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk154       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk155       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk156       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk157       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk158       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk159       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk160       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk161       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk162       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk163       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk164       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk165       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk166       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk167       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk168       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk169       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk170       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk171       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk172       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk173       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk174       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk175       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk176       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk177       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk178       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk179       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk180       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk181       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk182       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk183       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk184       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk185       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk186       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk187       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk188       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk189       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk190       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk191       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk192       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk193       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk194       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk195       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk196       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk197       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk198       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk199       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk200       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk201       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk202       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk203       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk204       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk205       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk206       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk207       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk208       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk209       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk210       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk211       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk212       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk213       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk214       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk215       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk216       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk217       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk218       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk219       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk220       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk221       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk222       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk223       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk224       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk225       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk226       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk227       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk228       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk229       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk230       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk231       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk232       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk233       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk234       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk235       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk236       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk237       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk238       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk239       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk240       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk241       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk242       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk243       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk244       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk245       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk246       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk247       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk248       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk249       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk250       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk251       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk252       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk253       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk254       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk255       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk256       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk257       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk258       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk259       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk260       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk261       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk262       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk263       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk264       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk265       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk266       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk267       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk268       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk269       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk270       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk271       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk272       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk273       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk274       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk275       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk276       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk277       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk278       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk279       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk280       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk281       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk282       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk283       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk284       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk285       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk286       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk287       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk288       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk289       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk290       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk291       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk292       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk293       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk294       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk295       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk296       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk297       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk298       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk299       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk300       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk301       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk302       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk303       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk304       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk305       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk306       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk307       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk308       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk309       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk310       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk311       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk312       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk313       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk314       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk315       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk316       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk317       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk318       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk319       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk320       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk321       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk322       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk323       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk324       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk325       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk326       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk327       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk328       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk329       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk330       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk331       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk332       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk333       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk334       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk335       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk336       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk337       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk338       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk339       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk340       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk341       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk342       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk343       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk344       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk345       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk346       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk347       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk348       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk349       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk350       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk351       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk352       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk353       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk354       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk355       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk356       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk357       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk358       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk359       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk360       Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk361       Available 00-00-01    DELL Compellent Storage subsystem disk
pdisk362       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk363       Available 00-01-01    DELL Compellent Storage subsystem disk
pdisk364       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk365       Available 0D-00-01    DELL Compellent Storage subsystem disk
pdisk366       Available 0D-01-01    DELL Compellent Storage subsystem disk
pdisk367       Available 0D-01-01    DELL Compellent Storage subsystem disk
pkcs11         Available             ACF/PKCS#11 Device
powerha_crlv   Defined               Logical volume
proc0          Available 00-00       Processor
proc8          Available 00-08       Processor
proc16         Available 00-16       Processor
proc24         Available 00-24       Processor
proc32         Available 00-32       Processor
proc40         Available 00-40       Processor
proc48         Available 00-48       Processor
proc56         Available 00-56       Processor
proc64         Available 00-64       Processor
proc72         Available 00-72       Processor
proc80         Available 00-80       Processor
proc88         Available 00-88       Processor
proc96         Available 00-96       Processor
proc104        Available 00-104      Processor
proc112        Available 00-112      Processor
proc120        Available 00-120      Processor
proc128        Available 00-128      Processor
proc136        Available 00-136      Processor
proc144        Available 00-144      Processor
proc152        Available 00-152      Processor
proc160        Available 00-160      Processor
proc168        Available 00-168      Processor
proc176        Available 00-176      Processor
proc184        Available 00-184      Processor
pty0           Available             Asynchronous Pseudo-Terminal
rcm0           Defined               Rendering Context Manager Subsystem
rootvg         Defined               Volume group
sas0           Available 03-00-00    Controller SAS Protocol
sas1           Available 09-00-00    Controller SAS Protocol
sata0          Available 03-00-00    Controller SATA Protocol
sata1          Available 09-00-00    Controller SATA Protocol
ses0           Available 03-00-00    SAS Enclosure Services Device
ses1           Available 09-00-00    SAS Enclosure Services Device
sfw0           Available             Storage Framework Module
sfwcomm0       Available 00-00-01-FF Fibre Channel Storage Framework Comm
sfwcomm1       Available 00-01-01-FF Fibre Channel Storage Framework Comm
sfwcomm2       Available 0D-00-01-FF Fibre Channel Storage Framework Comm
sfwcomm3       Available 0D-01-01-FF Fibre Channel Storage Framework Comm
sfwcomm4       Available 03-00-00-FF SAS Storage Framework Comm
sfwcomm5       Available 09-00-00-FF SAS Storage Framework Comm
sissas0        Available 03-00       PCIe3 x8 SAS RAID Internal Adapter 6Gb
sissas1        Available 09-00       PCIe3 x8 SAS RAID Internal Adapter 6Gb
sys0           Available             System Object
sysplanar0     Available             System Planar
tsmactloglv    Available             Logical volume
tsmactlogvg    Defined               Volume group
tsmappslv      Available             Logical volume
tsmarchlog2lv  Available             Logical volume
tsmarchloglv   Available             Logical volume
tsmarchlogvg   Defined               Volume group
tsmdb01lv      Available             Logical volume
tsmdb02lv      Available             Logical volume
tsmdb03lv      Available             Logical volume
tsmdb04lv      Available             Logical volume
tsmdb05lv      Available             Logical volume
tsmdb06lv      Available             Logical volume
tsmdb07lv      Available             Logical volume
tsmdb08lv      Available             Logical volume
tsmdb09lv      Available             Logical volume
tsmdb10lv      Available             Logical volume
tsmdb11lv      Available             Logical volume
tsmdb12lv      Available             Logical volume
tsmdbbkp01lv   Available             Logical volume
tsmdbbkp02lv   Available             Logical volume
tsmdbbkp03lv   Available             Logical volume
tsmdbbkp04lv   Available             Logical volume
tsmdbbkpvg     Defined               Volume group
tsmdbvg        Defined               Volume group
tsmfs01lv      Available             Logical volume
tsmfs01vg      Defined               Volume group
tsmfs02lv      Available             Logical volume
tsmfs02vg      Defined               Volume group
tsmfs03lv      Available             Logical volume
tsmfs04lv      Available             Logical volume
tsmfs05lv      Available             Logical volume
tsmfs06lv      Available             Logical volume
tsmfs07lv      Available             Logical volume
tsmfs08lv      Available             Logical volume
tsmfs09lv      Available             Logical volume
tsmfs10lv      Available             Logical volume
tsmfs11lv      Available             Logical volume
tsmfs12lv      Available             Logical volume
tsmfs13lv      Available             Logical volume
tsmfs14lv      Available             Logical volume
tsmfs15lv      Available             Logical volume
tsmfs16lv      Available             Logical volume
tsmfs17lv      Available             Logical volume
tsmfs18lv      Available             Logical volume
tsmfs19lv      Available             Logical volume
tsmfs20lv      Available             Logical volume
tsmfs21lv      Available             Logical volume
tsmfs22lv      Available             Logical volume
tsmhomelv      Available             Logical volume
tsmhomevg      Defined               Volume group
tsmrecoverylv  Available             Logical volume
tsmrecoveryvg  Defined               Volume group
usb0           Available             USB System Software
usbhc0         Available 05-00       Integrated USB 3.0 xHCI Adapter (4c1041821410b204)
vio0           Available             Virtual I/O Bus
vsa0           Available             LPAR Virtual Serial Adapter
vty0           Available             Asynchronous Terminal

2017-05-26 07:40:27: Check checklsdev.ksh completed successfully: returncode 0
2017-05-26 07:40:27: Runtime: 0 second(s)
2017-05-26 07:40:27: 45% complete - 121 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:27: Running check script 104 of 224: checklsdisp.ksh

Description:
------------

Display any properties of display devices.

2017-05-26 07:40:27: Check checklsdisp.ksh completed successfully: returncode 0
2017-05-26 07:40:27: Runtime: 0 second(s)
2017-05-26 07:40:27: 46% complete - 120 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:27: Running check script 105 of 224: checklsfsq.ksh

Description:
------------

Lists detailed information on all file systems by running:

# lsfs -q

Output:
------------

Name            Nodename   Mount Pt               VFS   Size    Options    Auto Accounting
/dev/hd4        --         /                      jfs2  4194304 --         yes  no 
  (lv size: 524288, fs size: 4194304, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)
/dev/hd1        --         /home                  jfs2  20971520 --         yes  no 
  (lv size: 2621440, fs size: 20971520, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)
/dev/hd2        --         /usr                   jfs2  27262976 --         yes  no 
  (lv size: 3407872, fs size: 27262976, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)
/dev/hd9var     --         /var                   jfs2  20971520 --         yes  no 
  (lv size: 2621440, fs size: 20971520, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)
/dev/hd3        --         /tmp                   jfs2  20971520 --         yes  no 
  (lv size: 2621440, fs size: 20971520, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)
/dev/hd11admin  --         /admin                 jfs2  2097152 --         yes  no 
  (lv size: 262144, fs size: 2097152, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)
/proc           --         /proc                  procfs --      --         yes  no 
/dev/hd10opt    --         /opt                   jfs2  20971520 --         yes  no 
  (lv size: 2621440, fs size: 20971520, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)
/dev/livedump   --         /var/adm/ras/livedump  jfs2  2097152 --         yes  no 
  (lv size: 262144, fs size: 2097152, block size: 4096, sparse files: yes, inline log: no, inline log 
size: 0, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, MountGuard: 
no)
/dev/mksysblv   --         /mksysb                jfs2  209715200 noatime,rw yes  no 
  (lv size: 26214400, fs size: 209715200, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 400, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: no)
/dev/tsmhomelv  --         /tsmhome               jfs2  104595456 rbrw,noatime,rw no   no 
  (lv size: 104595456, fs size: 104595456, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 200, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs01lv  --         /tsmfs01/tsmfs01       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs02lv  --         /tsmfs01/tsmfs02       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmactloglv --         /tsmactlog             jfs2  628097024 rbrw,noatime,rw no   no 
  (lv size: 628097024, fs size: 628097024, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs03lv  --         /tsmfs01/tsmfs03       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmarchloglv --         /tsmarchlog            jfs2  4286578688 rbrw,noatime,rw no   no 
  (lv size: 4286578688, fs size: 4286578688, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2044, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmarchlog2lv --         /tsmarchlog2           jfs2  4286578688 rbrw,noatime,rw no   no 
  (lv size: 4286578688, fs size: 4286578688, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2044, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs04lv  --         /tsmfs01/tsmfs04       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs05lv  --         /tsmfs01/tsmfs05       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdbbkp01lv --         /tsmdbbkp/tsmdbbkp01   jfs2  15015608320 rbrw,noatime,rw no   no 
  (lv size: 15015608320, fs size: 15015608320, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs06lv  --         /tsmfs01/tsmfs06       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdbbkp02lv --         /tsmdbbkp/tsmdbbkp02   jfs2  15015608320 rbrw,noatime,rw no   no 
  (lv size: 15015608320, fs size: 15015608320, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb01lv  --         /tsmdb/tsmdb01         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdbbkp03lv --         /tsmdbbkp/tsmdbbkp03   jfs2  15015608320 rbrw,noatime,rw no   no 
  (lv size: 15015608320, fs size: 15015608320, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs07lv  --         /tsmfs01/tsmfs07       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdbbkp04lv --         /tsmdbbkp/tsmdbbkp04   jfs2  15015608320 rbrw,noatime,rw no   no 
  (lv size: 15015608320, fs size: 15015608320, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb02lv  --         /tsmdb/tsmdb02         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs08lv  --         /tsmfs01/tsmfs08       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb03lv  --         /tsmdb/tsmdb03         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs09lv  --         /tsmfs01/tsmfs09       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmrecoverylv --         /tsmrecovery           jfs2  837812224 rbrw,noatime,rw no   no 
  (lv size: 837812224, fs size: 837812224, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmappslv  --         /tsmapps               jfs2  61865984 rbrw,noatime,rw no   no 
  (lv size: 61865984, fs size: 61865984, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 118, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb04lv  --         /tsmdb/tsmdb04         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs10lv  --         /tsmfs01/tsmfs10       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb05lv  --         /tsmdb/tsmdb05         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs11lv  --         /tsmfs01/tsmfs11       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb06lv  --         /tsmdb/tsmdb06         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb07lv  --         /tsmdb/tsmdb07         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs12lv  --         /tsmfs02/tsmfs12       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb08lv  --         /tsmdb/tsmdb08         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs13lv  --         /tsmfs02/tsmfs13       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb09lv  --         /tsmdb/tsmdb09         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs14lv  --         /tsmfs02/tsmfs14       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb10lv  --         /tsmdb/tsmdb10         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs15lv  --         /tsmfs02/tsmfs15       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb11lv  --         /tsmdb/tsmdb11         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs16lv  --         /tsmfs02/tsmfs16       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmdb12lv  --         /tsmdb/tsmdb12         jfs2  524288000 rbrw,noatime,rw no   no 
  (lv size: 524288000, fs size: 524288000, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 512, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs17lv  --         /tsmfs02/tsmfs17       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs18lv  --         /tsmfs02/tsmfs18       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs19lv  --         /tsmfs02/tsmfs19       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs20lv  --         /tsmfs02/tsmfs20       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs21lv  --         /tsmfs02/tsmfs21       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/tsmfs22lv  --         /tsmfs02/tsmfs22       jfs2  34292629504 rbrw,noatime,rw no   no 
  (lv size: 34292629504, fs size: 34292629504, block size: 4096, sparse files: yes, inline log: yes, 
inline log size: 2047, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: yes)
/dev/exportlv   --         /export                jfs2  41943040 rw,noatime yes  no 
  (lv size: 5242880, fs size: 41943040, block size: 4096, sparse files: yes, inline log: yes, inline 
log size: 80, EAformat: v1, Quota: no, DMAPI: no, VIX: yes, EFS: no, ISNAPSHOT: no, MAXEXT: 0, 
MountGuard: no)

2017-05-26 07:40:28: Check checklsfsq.ksh completed successfully: returncode 0
2017-05-26 07:40:28: Runtime: 1 second(s)
2017-05-26 07:40:28: 46% complete - 119 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:28: Running check script 106 of 224: checklslppall.ksh

Description:
------------

List all installed software (lslpp) packages.

This check script runs the following command:

# /usr/bin/lslpp -cOu -l

Output:
------------

Level:PTF Id:State:Type:EFIX Locked
DellSC_MPAIX.dellsc:3.0.0.7::COMMITTED:Dell Storage Center Software Suite for AIX
DellSC_MPAIX.fcp:3.0.0.7::COMMITTED:Compellent FCP Disk
DellSC_MPAIX.iscsi:3.0.0.7::COMMITTED:Compellent iSCSI Disk
DellSC_MPAIX.pcm:3.0.0.7::COMMITTED:Compellent PCM module
GSKit8.gskcrypt64.ppc.rte:8.0.50.66::COMMITTED:IBM GSKit Cryptography Runtime
GSKit8.gskssl64.ppc.rte:8.0.50.66::COMMITTED:IBM GSKit SSL Runtime With Acme Toolkit
ICU4C.rte:7.1.4.0::COMMITTED:International Components for Unicode 
Java5.sdk:5.0.0.620::COMMITTED:Java SDK 32-bit 
Java5_64.sdk:5.0.0.620::COMMITTED:Java SDK 64-bit 
Java6.sdk:6.0.0.561::COMMITTED:Java SDK 32-bit 
X11.adt.bitmaps:7.1.0.0::COMMITTED:AIXwindows Application Development Toolkit Bitmap Files 
X11.adt.imake:7.1.0.0::COMMITTED:AIXwindows Application Development Toolkit imake 
X11.adt.include:7.1.4.0::COMMITTED:AIXwindows Application Development Toolkit Include Files 
X11.adt.lib:7.1.4.30::COMMITTED:AIXwindows Application Development Toolkit Libraries 
X11.apps.aixterm:7.1.4.0::COMMITTED:AIXwindows aixterm Application 
X11.apps.clients:7.1.0.15::COMMITTED:AIXwindows Client Applications 
X11.apps.config:7.1.3.0::COMMITTED:AIXwindows Configuration Applications 
X11.apps.custom:7.1.0.0::COMMITTED:AIXwindows Customizing Tool 
X11.apps.msmit:7.1.2.15::COMMITTED:AIXwindows msmit Application 
X11.apps.rte:7.1.4.30::COMMITTED:AIXwindows Runtime Configuration Applications 
X11.apps.util:7.1.0.0::COMMITTED:AIXwindows Utility Applications 
X11.apps.xdm:7.1.4.0::COMMITTED:AIXwindows xdm Application 
X11.apps.xterm:7.1.4.0::COMMITTED:AIXwindows xterm Application 
X11.base.common:7.1.0.0::COMMITTED:AIXwindows Runtime Common Directories 
X11.base.lib:7.1.4.30::COMMITTED:AIXwindows Runtime Libraries 
X11.base.rte:7.1.4.30::COMMITTED:AIXwindows Runtime Environment 
X11.base.smt:7.1.4.0::COMMITTED:AIXwindows Runtime Shared Memory Transport 
X11.base.xpconfig:7.1.0.0::COMMITTED:Xprint Configuration Files 
X11.compat.lib.X11R6:7.1.4.30::COMMITTED:AIXwindows X11R6 Compatibility Libraries 
X11.compat.lib.X11R6_motif:7.1.3.0::COMMITTED:AIXwindows X11R6 Motif 1.2 & 2.1 Compatibility 
X11.fnt.coreX:7.1.0.0::COMMITTED:AIXwindows X Consortium Fonts 
X11.fnt.defaultFonts:7.1.0.0::COMMITTED:AIXwindows Default Fonts 
X11.fnt.iso1:7.1.0.0::COMMITTED:AIXwindows Latin 1 Fonts 
X11.fnt.iso_T1:7.1.0.0::COMMITTED:AIXwindows Latin Type1 Fonts 
X11.loc.en_US.base.lib:7.1.0.0::COMMITTED:AIXwindows Client Locale Config - U.S. English
X11.loc.en_US.base.rte:7.1.0.0::COMMITTED:AIXwindows Locale Configuration - U.S. English
X11.motif.lib:7.1.3.0::COMMITTED:AIXwindows Motif Libraries 
X11.motif.mwm:7.1.1.0::COMMITTED:AIXwindows Motif Window Manager 
X11.msg.en_US.adt.imake:7.1.3.0::COMMITTED:AIXwindows imake Messages - U.S. English 
X11.msg.en_US.apps.aixterm:7.1.3.0::COMMITTED:AIXwindows aixterm Messages - U.S. English 
X11.msg.en_US.apps.clients:7.1.3.0::COMMITTED:AIXwindows Client Apps Msgs - U.S. English 
X11.msg.en_US.apps.config:7.1.3.0::COMMITTED:AIXwindows Config Apps Msgs - U.S. English 
X11.msg.en_US.apps.custom:7.1.3.0::COMMITTED:AIXwindows Custom Tool Msgs - U.S. English 
X11.msg.en_US.apps.rte:7.1.3.0::COMMITTED:AIXwindows Runtime Config Msgs - U.S. English 
X11.msg.en_US.apps.xdm:7.1.3.0::COMMITTED:AIXwindows xdm Messages - U.S. English 
X11.msg.en_US.base.common:7.1.3.0::COMMITTED:AIXwindows Common Messages - U.S. English 
X11.msg.en_US.base.rte:7.1.3.0::COMMITTED:AIXwindows Runtime Env. Msgs - U.S. English 
X11.msg.en_US.motif.lib:7.1.3.0::COMMITTED:AIXwindows Motif Lib. Msgs - U.S. English 
X11.msg.en_US.motif.mwm:7.1.3.0::COMMITTED:AIX Motif Window Mgr Msgs - U.S. English 
X11.msg.en_US.vsm.rte:7.1.3.0::COMMITTED:Visual Sys Mgmt. Helps & Msgs - U.S. English 
X11.samples.apps.clients:7.1.4.0::COMMITTED:AIXwindows Sample X Consortium Clients Binary/Source 
X11.samples.common:7.1.0.0::COMMITTED:AIXwindows Imakefile Structure for Samples 
X11.samples.lib.Core:7.1.4.0::COMMITTED:AIXwindows Sample X Consortium Core Libraries Binary/Source 
X11.vsm.lib:7.1.0.0::COMMITTED:Visual System Managment Library
adde.v2.common.rte:7.1.3.45::COMMITTED:ADDE Common Device Runtime Environment 
adde.v2.ethernet.rte:7.1.4.30::COMMITTED:ADDE Ethernet Device Runtime Environment 
adde.v2.rdma.rte:7.1.4.30::COMMITTED:ADDE RDMA Device Runtime Environment 
bos.64bit:7.1.4.30::COMMITTED:Base Operating System 64 bit Runtime 
bos.acct:7.1.4.30::COMMITTED:Accounting Services 
bos.adt.base:7.1.4.30::COMMITTED:Base Application Development Toolkit 
bos.adt.debug:7.1.4.30::COMMITTED:Base Application Development Debuggers 
bos.adt.include:7.1.4.30::COMMITTED:Base Application Development Include Files 
bos.adt.lib:7.1.2.15::COMMITTED:Base Application Development Libraries 
bos.adt.libm:7.1.4.30::COMMITTED:Base Application Development Math Library 
bos.ae:7.1.1.15::COMMITTED:Activation Engine 
bos.ahafs:7.1.4.30::COMMITTED:Aha File System 
bos.aixpert.cmds:7.1.4.30::COMMITTED:AIX Security Hardening 
bos.alt_disk_install.boot_images:7.1.4.30::COMMITTED:Alternate Disk Installation Disk Boot Images 
bos.alt_disk_install.rte:7.1.4.30::COMMITTED:Alternate Disk Installation Runtime 
bos.aso:7.1.4.30::COMMITTED:Active System Optimizer 
bos.cdat:7.1.0.15::COMMITTED:Cluster Data Aggregation Tool 
bos.cdmount:7.1.0.0::COMMITTED:CD/DVD Automount Facility
bos.cluster.rte:7.1.4.30::COMMITTED:Cluster Aware AIX 
bos.clvm.enh:7.1.4.30::COMMITTED:Enhanced Concurrent Logical Volume Manager 
bos.content_list:7.1.0.0::COMMITTED:AIX Release Content List
bos.diag.com:7.1.4.30::COMMITTED:Common Hardware Diagnostics 
bos.diag.ecc:7.1.4.30::COMMITTED:Inventory Scout ECC Client 
bos.diag.rte:7.1.4.30::COMMITTED:Hardware Diagnostics 
bos.diag.util:7.1.4.30::COMMITTED:Hardware Diagnostics Utilities 
bos.ecc_client.rte:7.1.4.30::COMMITTED:Electronic Customer Care Runtime 
bos.help.msg.en_US.com:7.1.1.15::COMMITTED:WebSM/SMIT Context Helps - U.S. English 
bos.help.msg.en_US.smit:7.1.4.30::COMMITTED:SMIT Context Helps - U.S. English
bos.iconv.com:7.1.4.30::COMMITTED:Common Language to Language Converters 
bos.iconv.ucs.com:7.1.4.0::COMMITTED:Unicode Base Converters for AIX Code Sets/Fonts 
bos.iocp.rte:7.1.4.0::COMMITTED:I/O Completion Ports API 
bos.loc.iso.en_US:7.1.1.0::COMMITTED:Base System Locale ISO Code Set - U.S. English 
bos.mh:7.1.3.0::COMMITTED:Mail Handler 
bos.mls.lib:7.1.0.0::COMMITTED:Trusted AIX Libraries 
bos.mp64:7.1.4.30::COMMITTED:Base Operating System 64-bit Multiprocessor Runtime 
bos.msg.en_US.alt_disk_install.rte:7.1.3.0::COMMITTED:Alternate Disk Install Msgs - U.S. English 
bos.msg.en_US.diag.rte:7.1.3.0::COMMITTED:Hardware Diagnostics Messages - U.S. English 
bos.msg.en_US.net.ipsec:7.1.3.0::COMMITTED:IP Security Messages - U.S. English 
bos.msg.en_US.net.tcp.client:7.1.3.0::COMMITTED:TCP/IP Messages - U.S. English 
bos.msg.en_US.rte:7.1.3.0::COMMITTED:Base OS Runtime Messages - U.S. English 
bos.msg.en_US.txt.tfs:7.1.3.0::COMMITTED:Text Formatting Services Msgs - U.S. English 
bos.net.ipsec.keymgt:7.1.4.30::COMMITTED:IP Security Key Management 
bos.net.ipsec.rte:7.1.4.30::COMMITTED:IP Security 
bos.net.ncs:7.1.2.15::COMMITTED:Network Computing System 1.5.1 
bos.net.nfs.client:7.1.4.30::COMMITTED:Network File System Client 
bos.net.nis.client:7.1.4.30::COMMITTED:Network Information Service Client 
bos.net.snapp:7.1.3.0::COMMITTED:System Networking Analysis and Performance Pilot 
bos.net.tcp.adt:7.1.4.30::COMMITTED:TCP/IP Application Toolkit 
bos.net.tcp.client:7.1.4.30::COMMITTED:TCP/IP Client Support 
bos.net.tcp.server:7.1.4.30::COMMITTED:TCP/IP Server 
bos.net.tcp.smit:7.1.4.0::COMMITTED:TCP/IP SMIT Support 
bos.net.uucp:7.1.3.0::COMMITTED:Unix to Unix Copy Program 
bos.perf.diag_tool:7.1.4.0::COMMITTED:Performance Diagnostic Tool 
bos.perf.fdpr:7.1.4.30::COMMITTED:Feedback Directed Program Restructuring performance tool 
bos.perf.libperfstat:7.1.4.30::COMMITTED:Performance Statistics Library Interface 
bos.perf.perfstat:7.1.4.30::COMMITTED:Performance Statistics Interface 
bos.perf.pmaix:7.1.4.0::COMMITTED:Performance Management 
bos.perf.proctools:7.1.4.30::COMMITTED:Proc Filesystem Tools 
bos.perf.tools:7.1.4.30::COMMITTED:Base Performance Tools 
bos.perf.tune:7.1.4.30::COMMITTED:Performance Tuning Support 
bos.pfcdd.rte:7.1.4.30::COMMITTED:Power Flash Cache 
bos.pmapi.events:7.1.4.30::COMMITTED:Performance Monitor API Event Codes 
bos.pmapi.lib:7.1.4.30::COMMITTED:Performance Monitor API Library 
bos.pmapi.pmsvcs:7.1.4.30::COMMITTED:Performance Monitor API Kernel Extension 
bos.pmapi.samples:7.1.4.0::COMMITTED:Performance Monitor API Samples 
bos.pmapi.tools:7.1.4.30::COMMITTED:Performance Monitor API Tools 
bos.rte:7.1.4.30::COMMITTED:Base Operating System Runtime
bos.rte.Dt:7.1.0.0::COMMITTED:Desktop Integrator
bos.rte.ILS:7.1.4.30::COMMITTED:International Language Support
bos.rte.SRC:7.1.4.30::COMMITTED:System Resource Controller
bos.rte.X11:7.1.0.0::COMMITTED:AIXwindows Device Support
bos.rte.aio:7.1.4.30::COMMITTED:Asynchronous I/O Extension
bos.rte.archive:7.1.4.30::COMMITTED:Archive Commands
bos.rte.bind_cmds:7.1.4.30::COMMITTED:Binder and Loader Commands
bos.rte.boot:7.1.4.30::COMMITTED:Boot Commands
bos.rte.bosinst:7.1.4.30::COMMITTED:Base OS Install Commands
bos.rte.commands:7.1.4.30::COMMITTED:Commands
bos.rte.compare:7.1.4.30::COMMITTED:File Compare Commands
bos.rte.console:7.1.1.0::COMMITTED:Console
bos.rte.control:7.1.4.30::COMMITTED:System Control Commands
bos.rte.cron:7.1.4.30::COMMITTED:Batch Operations
bos.rte.date:7.1.4.30::COMMITTED:Date Control Commands
bos.rte.devices:7.1.4.0::COMMITTED:Base Device Drivers
bos.rte.devices_msg:7.1.4.30::COMMITTED:Device Driver Messages
bos.rte.diag:7.1.4.30::COMMITTED:Diagnostics
bos.rte.edit:7.1.4.30::COMMITTED:Editors
bos.rte.filesystem:7.1.4.30::COMMITTED:Filesystem Administration
bos.rte.iconv:7.1.4.30::COMMITTED:Language Converters
bos.rte.ifor_ls:7.1.4.30::COMMITTED:iFOR/LS Libraries
bos.rte.im:7.1.4.0::COMMITTED:Input Methods
bos.rte.install:7.1.4.32::COMMITTED:LPP Install Commands
bos.rte.jfscomp:7.1.3.0::COMMITTED:JFS Compression
bos.rte.libc:7.1.4.30::COMMITTED:libc Library
bos.rte.libcfg:7.1.4.0::COMMITTED:libcfg Library
bos.rte.libcur:7.1.4.30::COMMITTED:libcurses Library
bos.rte.libdbm:7.1.0.0::COMMITTED:libdbm Library
bos.rte.libnetsvc:7.1.0.0::COMMITTED:Network Services Libraries
bos.rte.libpthreads:7.1.4.30::COMMITTED:pthreads Library
bos.rte.libqb:7.1.0.0::COMMITTED:libqb Library
bos.rte.libs:7.1.0.0::COMMITTED:libs Library
bos.rte.loc:7.1.2.15::COMMITTED:Base Locale Support
bos.rte.lvm:7.1.4.30::COMMITTED:Logical Volume Manager
bos.rte.man:7.1.4.0::COMMITTED:Man Commands
bos.rte.methods:7.1.4.30::COMMITTED:Device Config Methods
bos.rte.misc_cmds:7.1.4.0::COMMITTED:Miscellaneous Commands
bos.rte.mlslib:7.1.2.15::COMMITTED:Trusted AIX Libraries
bos.rte.net:7.1.3.0::COMMITTED:Network
bos.rte.odm:7.1.4.0::COMMITTED:Object Data Manager
bos.rte.printers:7.1.4.30::COMMITTED:Front End Printer Support
bos.rte.security:7.1.4.30::COMMITTED:Base Security Function
bos.rte.serv_aid:7.1.4.30::COMMITTED:Error Log Service Aids
bos.rte.shell:7.1.4.30::COMMITTED:Shells (bsh, ksh, csh)
bos.rte.streams:7.1.2.15::COMMITTED:Streams Libraries
bos.rte.tty:7.1.4.30::COMMITTED:Base TTY Support and Commands
bos.suma:7.1.4.30::COMMITTED:Service Update Management Assistant (SUMA) 
bos.swma:7.1.2.15::COMMITTED:Software Maintenance Agreement 
bos.sysmgt.loginlic:7.1.3.0::COMMITTED:License Management 
bos.sysmgt.nim.client:7.1.4.30::COMMITTED:Network Install Manager - Client Tools 
bos.sysmgt.nim.master:7.1.4.30::COMMITTED:Network Install Manager - Master Tools 
bos.sysmgt.nim.spot:7.1.4.30::COMMITTED:Network Install Manager - SPOT 
bos.sysmgt.quota:7.1.4.30::COMMITTED:Filesystem Quota Commands 
bos.sysmgt.serv_aid:7.1.4.30::COMMITTED:Software Error Logging and Dump Service Aids 
bos.sysmgt.smit:7.1.4.30::COMMITTED:System Management Interface Tool (SMIT) 
bos.sysmgt.sysbr:7.1.4.30::COMMITTED:System Backup and BOS Install Utilities 
bos.sysmgt.trace:7.1.4.30::COMMITTED:Software Trace Service Aids 
bos.terminfo.rte:7.1.0.0::COMMITTED:Run-time Environment for AIX Terminals
bos.txt.spell:7.1.0.0::COMMITTED:Writer's Tools Commands 
bos.txt.tfs:7.1.4.0::COMMITTED:Text Formatting Services Commands 
bos.wpars:7.1.4.30::COMMITTED:AIX Workload Partitions 
cache.mgt.rte:7.1.4.30::COMMITTED:AIX SSD Cache Device Management 
cdrtools.base:1.9.0.9::COMMITTED:CD/DVD recorder
cdrtools.man.en_US:1.9.0.9::COMMITTED:CD/DVD recorder man page documentation
clic.rte.kernext:4.10.0.1::COMMITTED:CryptoLite for C Kernel
clic.rte.lib:4.10.0.1::COMMITTED:CryptoLite for C Library
cluster.adt.es.client.include:7.1.3.1::COMMITTED:PowerHA SystemMirror Client Include Files
cluster.adt.es.client.samples.clinfo:7.1.3.0::COMMITTED:PowerHA SystemMirror Client CLINFO Samples 
cluster.adt.es.client.samples.clstat:7.1.3.0::COMMITTED:PowerHA SystemMirror Client Clstat Samples 
cluster.adt.es.client.samples.libcl:7.1.3.0::COMMITTED:PowerHA SystemMirror Client LIBCL Samples 
cluster.doc.en_US.assist.smartassists.pdf:7.1.3.0::COMMITTED:PowerHA SystemMirror Smart Assists PDF 
Documentation - U.S. English 
cluster.doc.en_US.es.pdf:7.1.3.0::COMMITTED:PowerHA SystemMirror PDF Documentation - U.S. English 
cluster.es.assist.common:7.1.3.5::COMMITTED:PowerHA SystemMirror Smart Assist Common Files
cluster.es.assist.db2:7.1.3.3::COMMITTED:PowerHA SystemMirror Smart Assist for DB2
cluster.es.assist.dhcp:7.1.3.0::COMMITTED:PowerHA SystemMirror Smart Assist for DHCP 
cluster.es.assist.dns:7.1.3.1::COMMITTED:PowerHA SystemMirror Smart Assist for DNS
cluster.es.assist.domino:7.1.3.2::COMMITTED:PowerHA SystemMirror SmartAssist for IBM Lotus domino 
server
cluster.es.assist.filenet:7.1.3.1::COMMITTED:PowerHA SystemMirror Smart Assist for FileNet P8
cluster.es.assist.ihs:7.1.3.0::COMMITTED:PowerHA SystemMirror Smart Assist for IBM HTTP Server 
cluster.es.assist.maxdb:7.1.3.2::COMMITTED:PowerHA SystemMirror Smart Assist for SAP MaxDB
cluster.es.assist.oraappsrv:7.1.3.0::COMMITTED:PowerHA SystemMirror Smart Assist for Oracle Application 
Server 
cluster.es.assist.oracle:7.1.3.4::COMMITTED:PowerHA SystemMirror Smart Assist for Oracle
cluster.es.assist.printServer:7.1.3.1::COMMITTED:PowerHA SystemMirror Smart Assist for Print Subsystem
cluster.es.assist.sap:7.1.3.5::COMMITTED:PowerHA SystemMirror Smart Assist for SAP
cluster.es.assist.tds:7.1.3.2::COMMITTED:PowerHA SystemMirror Smart Assist for IBM Tivoli Directory 
Server
cluster.es.assist.tsmadmin:7.1.3.3::COMMITTED:PowerHA SystemMirror SmartAssist for IBM TSM Admin center
cluster.es.assist.tsmclient:7.1.3.2::COMMITTED:PowerHA SystemMirror SmartAssist for IBM TSM Client
cluster.es.assist.tsmserver:7.1.3.1::COMMITTED:PowerHA SystemMirror SmartAssist for IBM TSM Server
cluster.es.assist.websphere:7.1.3.2::COMMITTED:PowerHA SystemMirror Smart Assist for WebSphere
cluster.es.assist.wmq:7.1.3.4::COMMITTED:PowerHA SystemMirror Smart Assist for MQ Series
cluster.es.client.clcomd:7.1.3.3::COMMITTED:Cluster Communication Infrastructure
cluster.es.client.lib:7.1.3.6::COMMITTED:PowerHA SystemMirror Client Libraries
cluster.es.client.rte:7.1.3.3::COMMITTED:PowerHA SystemMirror Client Runtime
cluster.es.client.utils:7.1.3.3::COMMITTED:PowerHA SystemMirror Client Utilities
cluster.es.cspoc.cmds:7.1.3.6::COMMITTED:CSPOC Commands
cluster.es.cspoc.rte:7.1.3.6::COMMITTED:CSPOC Runtime Commands
cluster.es.migcheck:7.1.3.0::COMMITTED:PowerHA SystemMirror Migration support 
cluster.es.nfs.rte:7.1.3.3::COMMITTED:NFS Support
cluster.es.server.diag:7.1.3.6::COMMITTED:Server Diags
cluster.es.server.events:7.1.3.6::COMMITTED:Server Events
cluster.es.server.rte:7.1.3.6::COMMITTED:Base Server Runtime
cluster.es.server.testtool:7.1.3.1::COMMITTED:Cluster Test Tool
cluster.es.server.utils:7.1.3.6::COMMITTED:Server Utilities
cluster.license:7.1.3.0::COMMITTED:PowerHA SystemMirror Electronic License 
cluster.msg.en_US.assist:7.1.3.3::COMMITTED:PowerHA SystemMirror Smart Assist Messages - U.S. English
cluster.msg.en_US.es.client:7.1.3.0::COMMITTED:PowerHA SystemMirror Client Messages - U.S. English 
cluster.msg.en_US.es.server:7.1.3.4::COMMITTED:Recovery Driver Messages - U.S. English
devices.artic960.diag:7.1.0.0::COMMITTED:IBM ARTIC960 Adapter Diagnostics 
devices.artic960.rte:7.1.4.0::COMMITTED:IBM ARTIC960 Runtime Support 
devices.artic960.ucode:7.1.0.0::COMMITTED:IBM ARTIC960 Adapter Software 
devices.chrp.AT97SC3201_r.rte:7.1.0.0::COMMITTED:Trusted Platform Module Device Software
devices.chrp.IBM.HFI.rte:1.1.1.0::COMMITTED:IBM Host Fabric Interface (HFI) Runtime
devices.chrp.IBM.lhca.rte:7.1.4.30::COMMITTED:Infiniband Logical HCA Runtime Environment 
devices.chrp.IBM.lhea.diag:7.1.0.0::COMMITTED:Host Ethernet Adapter Diagnostics 
devices.chrp.IBM.lhea.rte:7.1.4.0::COMMITTED:Host Ethernet Adapter (HEA) Runtime Environment 
devices.chrp.base.ServiceRM:2.5.1.1::COMMITTED:RSCT Service Resource Manager
devices.chrp.base.diag:7.1.4.30::COMMITTED:RISC CHRP Base System Device Diagnostics 
devices.chrp.base.rte:7.1.4.30::COMMITTED:RISC PC Base System Device Software (CHRP) 
devices.chrp.pci.rte:7.1.4.30::COMMITTED:PCI Bus Software (CHRP) 
devices.chrp.pciex.rte:7.1.0.0::COMMITTED:PCI Express Bus Software (CHRP)
devices.chrp.vdevice.rte:7.1.4.30::COMMITTED:Virtual I/O Bus Support 
devices.chrp_lpar.base.ras:7.1.3.0::COMMITTED:CHRP LPAR RAS Support 
devices.common.IBM.async.diag:7.1.0.0::COMMITTED:Common Serial Adapter Diagnostics
devices.common.IBM.atm.rte:7.1.4.30::COMMITTED:Common ATM Software 
devices.common.IBM.crypt.rte:7.1.0.0::COMMITTED:Cryptographic Common Runtime Environment
devices.common.IBM.cx.rte:7.1.3.0::COMMITTED:CX Common Adapter Software 
devices.common.IBM.disk.rte:7.1.4.30::COMMITTED:Common IBM Disk Software 
devices.common.IBM.ethernet.rte:7.1.4.30::COMMITTED:Common Ethernet Software 
devices.common.IBM.fc.hba-api:7.1.4.30::COMMITTED:Common HBA API Library 
devices.common.IBM.fc.rte:7.1.4.30::COMMITTED:Common IBM FC Software 
devices.common.IBM.fda.diag:7.1.0.0::COMMITTED:Common Diskette Adapter and Device Diagnostics 
devices.common.IBM.fda.rte:7.1.3.0::COMMITTED:Common Diskette Device Software 
devices.common.IBM.hdlc.rte:7.1.3.15::COMMITTED:Common HDLC Software 
devices.common.IBM.hdlc.sdlc:7.1.3.0::COMMITTED:SDLC COMIO Device Driver Emulation 
devices.common.IBM.hfi.rte:1.1.1.0::COMMITTED:IBM Host Fabric Interface (HFI) files
devices.common.IBM.ib.rte:7.1.4.30::COMMITTED:Infiniband Common Runtime Environment 
devices.common.IBM.ide.rte:7.1.0.0::COMMITTED:Common IDE I/O Controller Software
devices.common.IBM.iscsi.rte:7.1.3.15::COMMITTED:Common iSCSI Files 
devices.common.IBM.ktm_std.diag:7.1.0.0::COMMITTED:Common Keyboard, Mouse, and Tablet Device 
Diagnostics 
devices.common.IBM.ktm_std.rte:7.1.3.0::COMMITTED:Common Keyboard, Tablet, and Mouse Software 
devices.common.IBM.ml:1.5.1.3::COMMITTED:Multi Link Interface Runtime
devices.common.IBM.mpio.rte:7.1.4.30::COMMITTED:MPIO Disk Path Control Module 
devices.common.IBM.mpt2.diag:7.1.2.0::COMMITTED:MPT SAS Device Diagnostics 
devices.common.IBM.mpt2.rte:7.1.4.30::COMMITTED:MPT SAS Device Software 
devices.common.IBM.ppa.diag:7.1.0.0::COMMITTED:Common Parallel Printer Adapter Diagnostics 
devices.common.IBM.ppa.rte:7.1.3.0::COMMITTED:Common Parallel Printer Adapter Software 
devices.common.IBM.scsi.rte:7.1.4.30::COMMITTED:Common SCSI I/O Controller Software 
devices.common.IBM.sissas.rte:7.1.4.30::COMMITTED:Common IBM SAS RAID Software 
devices.common.IBM.son.diag:7.1.2.0::COMMITTED:GXT Common Graphics Adapter Diagnostics I 
devices.common.IBM.storfwork.rte:7.1.4.30::COMMITTED:Storage Framework Module 
devices.common.IBM.tokenring.rte:7.1.3.15::COMMITTED:Common Token Ring Software 
devices.common.IBM.usb.diag:7.1.3.15::COMMITTED:Common USB Adapter Diagnostics 
devices.common.IBM.usb.rte:7.1.4.30::COMMITTED:USB System Software 
devices.common.IBM.xhci.rte:7.1.4.30::COMMITTED:Common xHCI Adapter Device Software 
devices.common.base.diag:7.1.0.0::COMMITTED:Common Base System Diagnostics
devices.common.rspcbase.rte:7.1.3.0::COMMITTED:RISC PC Common Base System Device Software 
devices.ethernet.ct3.cdli:7.1.4.30::COMMITTED:10 Gigabit Ethernet Adapter Software 
devices.ethernet.ct3.rte:7.1.4.30::COMMITTED:10 Gigabit Ethernet PCI-Express Host Bus Adapter Software 
devices.ethernet.lnc.rte:7.1.4.30::COMMITTED:10 Gigabit Ethernet PCI-Express Adapter Software (lnc) 
devices.ethernet.lnc2.rte:7.1.4.30::COMMITTED:10 Gigabit Ethernet PCI-Express Adapter Software (lnc2) 
devices.ethernet.mlx.diag:7.1.4.0::COMMITTED:RoCE Converged Network Adapter Diagnostics 
devices.ethernet.mlx.rte:7.1.4.30::COMMITTED:RoCE Converged Network Adapter 
devices.ethernet.mlxc.rte:7.1.4.30::COMMITTED:MLXC RoCE Adapter Software 
devices.ethernet.shi.rte:7.1.4.30::COMMITTED:10 Gigabit Ethernet PCI-Express Adapter Software (shi) 
devices.fcp.disk.array.diag:7.1.0.0::COMMITTED:Fibre Channel RAID Device Diagnostics 
devices.fcp.disk.array.rte:7.1.4.0::COMMITTED:FC SCSI RAIDiant Array Device Support Software 
devices.fcp.disk.rte:7.1.4.30::COMMITTED:FC SCSI CD-ROM, Disk, Read/Write Optical Device Software 
devices.fcp.tape.rte:7.1.4.30::COMMITTED:FC SCSI Tape Device Software 
devices.graphics.com:7.1.4.0::COMMITTED:Graphics Adapter Common Software 
devices.graphics.voo:7.1.0.0::COMMITTED:Graphics Adapter VOO and Stereo Software 
devices.ide.cdrom.diag:7.1.4.30::COMMITTED:IDE CDROM, Cdrom Device Diagnostics 
devices.ide.cdrom.rte:7.1.4.0::COMMITTED:IDE CDROM Device Software 
devices.ide.disk.diag:7.1.0.0::COMMITTED:IDE Disk Device Diagnostics 
devices.ide.disk.rte:7.1.4.0::COMMITTED:IDE Disk Device Software 
devices.isa_sio.IBM0017.diag:7.1.0.0::COMMITTED:Audio Device Diagnostics 
devices.isa_sio.IBM0017.rte:7.1.3.0::COMMITTED:Audio Device 
devices.isa_sio.IBM0019.diag:7.1.0.0::COMMITTED:ISA Tablet Software (IBM0019) Diagnostics 
devices.isa_sio.IBM0019.rte:7.1.3.0::COMMITTED:ISA Tablet Software (IBM0019) 
devices.isa_sio.chrp.8042.diag:7.1.0.0::COMMITTED:ISA Keyboard & Mouse Diagnostics (CHRP) 
devices.isa_sio.chrp.8042.rte:7.1.3.0::COMMITTED:ISA Keyboard & Mouse Software (CHRP) 
devices.isa_sio.chrp.ecp.diag:7.1.0.0::COMMITTED:CHRP IEEE 1284 Parallel Port Adapter Diagnostics 
devices.isa_sio.chrp.ecp.rte:7.1.4.30::COMMITTED:CHRP IEEE1284 Parallel Port Adapter Software 
devices.isa_sio.pnpPNP.501.diag:7.1.0.0::COMMITTED:CHRP Serial Adapter Diagnostics (pnpPNP.501) 
devices.isa_sio.pnpPNP.501.rte:7.1.4.0::COMMITTED:CHRP Serial Adapter Software (pnpPNP.501) 
devices.isa_sio.pnpPNP.700.diag:7.1.0.0::COMMITTED:CHRP Diskette Adapter Diagnostic Software 
(pnpPNP.700) 
devices.isa_sio.pnpPNP.700.rte:7.1.3.0::COMMITTED:CHRP Diskette Adapter Software (pnpPNP.700) 
devices.iscsi.disk.rte:7.1.0.15::COMMITTED:iSCSI Disk Software 
devices.iscsi.tape.rte:7.1.0.0::COMMITTED:iSCSI Tape Software
devices.iscsi_sw.rte:7.1.4.0::COMMITTED:iSCSI Software Device Driver 
devices.loopback.rte:7.1.4.30::COMMITTED:Loopback Device Driver 
devices.msg.en_US.base.com:7.1.3.0::COMMITTED:Base Sys Device Software Msg - U.S. English 
devices.msg.en_US.chrp.IBM.HFI.rte:1.1.1.0::COMMITTED:HFI Rte Msgs - U.S. English
devices.msg.en_US.common.IBM.hfi.rte:1.1.1.0::COMMITTED:HFI Runtime Messages - U.S. English
devices.msg.en_US.common.IBM.ml:1.5.1.0::COMMITTED:Multi Link Interface Runtime - U.S. English
devices.msg.en_US.diag.rte:7.1.3.0::COMMITTED:Device Diagnostics Messages - U.S. English 
devices.msg.en_US.rspc.base.com:7.1.3.0::COMMITTED:RISC PC Software Messages - U.S. English 
devices.msg.en_US.sys.mca.rte:7.1.3.0::COMMITTED:Micro Channel Bus Software Msg - U.S. English 
devices.pci.00100100.com:7.1.3.0::COMMITTED:Common Symbios PCI SCSI I/O Controller Software 
devices.pci.00100b00.diag:7.1.0.0::COMMITTED:SYM53C896 Dual Channel PCI-2 Ultra2 SCSI Adapter 
Diagnostics
devices.pci.00100b00.rte:7.1.0.0::COMMITTED:SYM53C896 Dual Channel PCI SCSI I/O Controller
devices.pci.00100c00.diag:7.1.0.0::COMMITTED:SYM53C895 LVD PCI SCSI I/O Controller Diagnostics
devices.pci.00100c00.rte:7.1.0.0::COMMITTED:SYM53C895 PCI SCSI I/O Controller Software
devices.pci.00100f00.diag:7.1.3.0::COMMITTED:SYM53C8xxA PCI SCSI I/O Controller Diagnostics 
devices.pci.00100f00.rte:7.1.4.0::COMMITTED:SYM53C8xxA PCI SCSI I/O Controller Software 
devices.pci.00102100.diag:7.1.0.0::COMMITTED:SYM53C1010 Dual Channel PCI Ultra3 SCSI Adapter 
Diagnostics
devices.pci.00102100.rte:7.1.0.0::COMMITTED:SYM53C1010 PCI Ultra-3 SCSI I/O Controller Software
devices.pci.00105000.com:7.1.4.30::COMMITTED:Common SAS Expansion Card Device Software 
devices.pci.00105000.diag:7.1.2.0::COMMITTED:LSI SAS Adapter Diagnostics 
devices.pci.00105000.rte:7.1.0.0::COMMITTED:SAS Expansion Card Device Software (00105000) 
devices.pci.02105e51.X11:7.1.1.15::COMMITTED:AIXwindows Native Display Adapter Software 
devices.pci.02105e51.diag:7.1.2.15::COMMITTED:Native Display Graphics Adapter Diagnostics 
devices.pci.02105e51.rte:7.1.4.0::COMMITTED:Native Display Adapter Software 
devices.pci.13100560.diag:7.1.3.0::COMMITTED:PCI Audio Adapter Diagnostics 
devices.pci.13100560.rte:7.1.3.0::COMMITTED:PCI Audio Adapter (13100560) Runtime Software 
devices.pci.14100401.diag:7.1.4.0::COMMITTED:Gigabit Ethernet-SX PCI Adapter Diagnostics 
devices.pci.14100401.rte:7.1.3.0::COMMITTED:Gigabit Ethernet-SX PCI Adapter Software 
devices.pci.14100c03.diag:7.1.0.0::COMMITTED:PCI-XDDR Auxiliary Cache Adapter Diagnostics (14100c03)
devices.pci.14100c03.rte:7.1.0.0::COMMITTED:PCI-XDDR Auxiliary Cache Adapter Software (14100c03)
devices.pci.14100d03.diag:7.1.0.0::COMMITTED:PCI-XDDR Auxiliary Cache Adapter Diagnostics
devices.pci.14100d03.rte:7.1.0.0::COMMITTED:PCI-XDDR Auxiliary Cache Adapter Software
devices.pci.14101103.diag:7.1.0.0::COMMITTED:4-Port 10/100/1000 Base-TX PCI-X Adapter Diagnostics 
devices.pci.14101103.rte:7.1.3.0::COMMITTED:4-Port 10/100/1000 Base-TX PCI-X Adapter Software 
devices.pci.14101403.diag:7.1.0.0::COMMITTED:Gigabit Ethernet-SX Adapter Diagnostics 
devices.pci.14101403.rte:7.1.4.0::COMMITTED:Gigabit Ethernet-SX Adapter Software 
devices.pci.14101b02.X11:7.1.1.15::COMMITTED:AIXwindows GXT6500P Graphics Adapter Software 
devices.pci.14101b02.diag:7.1.0.0::COMMITTED:GXT6500P Graphics Adapter Diagnostics 
devices.pci.14101b02.rte:7.1.4.0::COMMITTED:GXT6500P Graphics Adapter Software 
devices.pci.14101c02.X11:7.1.1.15::COMMITTED:AIXwindows GXT4500P Graphics Adapter Software 
devices.pci.14101c02.diag:7.1.0.0::COMMITTED:GXT4500P Graphics Adapter Diagnostics 
devices.pci.14101c02.rte:7.1.4.0::COMMITTED:GXT4500P Graphics Adapter Software 
devices.pci.14102203.diag:7.1.0.0::COMMITTED:IBM 1 Gigabit-TX iSCSI TOE PCI-X Adapter Diagnostics
devices.pci.14102203.rte:7.1.0.0::COMMITTED:IBM 1 Gigabit-TX iSCSI TOE PCI-X Adapter
devices.pci.14102e00.diag:7.1.3.0::COMMITTED:IBM PCI SCSI RAID Adapter Diagnostics Support 
devices.pci.14102e00.rte:7.1.4.0::COMMITTED:IBM PCI SCSI RAID Adapter Device Software Support 
devices.pci.14103302.X11:7.1.1.0::COMMITTED:AIXwindows GXT135P Graphics Adapter Software 
devices.pci.14103302.diag:7.1.2.15::COMMITTED:GXT135P Graphics Adapter Diagnostics 
devices.pci.14103302.rte:7.1.4.0::COMMITTED:GXT135P Graphics Adapter Software 
devices.pci.14103e00.diag:7.1.3.0::COMMITTED:IBM PCI Tokenring Adapter (14103e00) Diagnostics 
devices.pci.14103e00.rte:7.1.3.0::COMMITTED:IBM PCI Token-Ring Adapter Software 
devices.pci.14104e00.diag:7.1.0.0::COMMITTED:PCI ATM Adapter (14104e00) Diagnostics
devices.pci.14104e00.rte:7.1.0.0::COMMITTED:PCI ATM Adapter (14104e00) Software
devices.pci.14104f00.diag:7.1.0.0::COMMITTED:PCI ATM Adapter (14104f00) Diagnostics
devices.pci.14104f00.rte:7.1.0.0::COMMITTED:PCI ATM Adapter (14104f00) Software
devices.pci.14105000.diag:7.1.0.0::COMMITTED:PCI ATM Adapter (14105000) Diagnostics
devices.pci.14105000.rte:7.1.0.0::COMMITTED:PCI ATM Adapter (14105000) Software
devices.pci.14105e01.com:7.1.4.30::COMMITTED:622Mbps ATM PCI Adapter Common Software 
devices.pci.14105e01.diag:7.1.3.0::COMMITTED:622Mbps ATM PCI Adapter Diagnostics 
devices.pci.14105e01.rte:7.1.0.0::COMMITTED:622Mbps ATM PCI Adapter Software 
devices.pci.14106001.diag:7.1.0.0::COMMITTED:64bit/66MHz PCI ATM 155 MMF Adapter Diagnostics
devices.pci.14106001.rte:7.1.0.0::COMMITTED:64bit/66MHz PCI ATM 155 MMF Adapter Software
devices.pci.14106402.diag:7.1.0.0::COMMITTED:PCI-X Quad Channel U320 SCSI RAID Adapter Diagnostics
devices.pci.14106402.rte:7.1.0.0::COMMITTED:PCI-X Quad Channel U320 SCSI RAID Adapter Software
devices.pci.14106402.ucode:7.1.0.0::COMMITTED:PCI-X Quad Channel U320 SCSI RAID Adapter Microcode
devices.pci.14106602.diag:7.1.0.0::COMMITTED:PCI-X Dual Channel SCSI Adapter Diagnostics 
devices.pci.14106602.rte:7.1.3.0::COMMITTED:PCI-X Dual Channel SCSI Adapter Device Software 
devices.pci.14106602.ucode:7.1.2.15::COMMITTED:PCI-X Dual Channel SCSI Adapter Microcode 
devices.pci.14106703.diag:7.1.0.0::COMMITTED:PCI-X Gigabit Ethernet-SX Adapter Diagnostics (14106703)
devices.pci.14106703.rte:7.1.0.0::COMMITTED:Gigabit Ethernet-SX PCI-X Adapter Software
devices.pci.14106802.diag:7.1.0.0::COMMITTED:Gigabit Ethernet-SX PCI-X Adapter Diagnostics 
devices.pci.14106802.rte:7.1.3.0::COMMITTED:Gigabit Ethernet-SX PCI-X Adapter Software 
devices.pci.14106902.diag:7.1.3.0::COMMITTED:10/100/1000 Base-TX PCI-X Adapter Diagnostics 
devices.pci.14106902.rte:7.1.4.30::COMMITTED:10/100/1000 Base-TX PCI-X Adapter Software 
devices.pci.14106e01.X11:7.1.1.15::COMMITTED:AIXwindows GXT4000P Graphics Adapter Software 
devices.pci.14106e01.diag:7.1.0.0::COMMITTED:GXT4000P Graphics Adapter Diagnostics 
devices.pci.14106e01.rte:7.1.4.0::COMMITTED:GXT4000P Graphics Adapter Software 
devices.pci.14107001.X11:7.1.1.15::COMMITTED:AIXwindows GXT6000P Graphics Adapter Software 
devices.pci.14107001.diag:7.1.0.0::COMMITTED:GXT6000P Graphics Adapter Diagnostics 
devices.pci.14107001.rte:7.1.4.0::COMMITTED:GXT6000P Graphics Adapter Software 
devices.pci.14107802.diag:7.1.0.0::COMMITTED:PCI-X Dual Channel Ultra320 SCSI RAID Adapter Diagnostics 
devices.pci.14107802.rte:7.1.4.0::COMMITTED:PCI-X Dual Channel Ultra320 SCSI RAID Adapter Software 
devices.pci.14107802.ucode:7.1.2.15::COMMITTED:PCI-X Dual Channel Ultra320 SCSI RAID Adapter Microcode 
devices.pci.14107c00.com:7.1.4.30::COMMITTED:Common ATM Adapter Software 
devices.pci.14107c00.diag:7.1.3.0::COMMITTED:PCI ATM Adapter (14107c00) Diagnostics 
devices.pci.14107c00.rte:7.1.0.0::COMMITTED:PCI ATM Adapter (14107c00) Software 
devices.pci.14108802.diag:7.1.0.0::COMMITTED:Gigabit-SX Ethernet PCI-X Adapter Diagnostics 
devices.pci.14108802.rte:7.1.3.0::COMMITTED:2-Port Gigabit Ethernet-SX PCI-X Adapter Software 
devices.pci.14108902.diag:7.1.0.0::COMMITTED:10/100/1000 Base-TX PCI-X Adapter Diagnostics 
devices.pci.14108902.rte:7.1.3.0::COMMITTED:2-Port 10/100/1000 Base-TX PCI-X Adapter Software 
devices.pci.14108c00.rte:7.1.4.30::COMMITTED:ARTIC960Hx 4-Port Selectable PCI Adapter Runtime Software 
devices.pci.14108d02.diag:7.1.0.0::COMMITTED:PCI-X DDR Dual Channel SAS RAID Adapter Diagnostics
devices.pci.14108d02.rte:7.1.0.0::COMMITTED:PCI-XDDR Dual Channel SAS RAID Adapter Software
devices.pci.14109f00.diag:7.1.4.0::COMMITTED:IBM PCI 4758 Cryptographic Coprocessor Card Diagnostics 
devices.pci.14109f00.rte:7.1.3.0::COMMITTED:IBM 4758 PCI Cryptographic Coprocessor 
devices.pci.1410a803.diag:7.1.0.0::COMMITTED:4-port Asynchronous EIA-232 PCI-E Adapter Diagnostics 
devices.pci.1410a803.rte:7.1.2.0::COMMITTED:4 Port Async EIA-232 PCIe Adapter Software 
devices.pci.1410ba02.diag:7.1.0.0::COMMITTED:10 Gigabit-SR Ethernet PCI-X Adapter Diagnostics
devices.pci.1410ba02.rte:7.1.0.0::COMMITTED:10 Gigabit-SR Ethernet PCI-X Adapter Software
devices.pci.1410bb02.diag:7.1.3.0::COMMITTED:10 Gigabit-LR Ethernet PCI-X Adapter Diagnostics 
devices.pci.1410bb02.rte:7.1.3.0::COMMITTED:10 Gigabit-LR Ethernet PCI-X Adapter Software 
devices.pci.1410bd02.diag:7.1.3.0::COMMITTED:PCI-X266 3GB SAS RAID Adapter Diagnostics 
devices.pci.1410bd02.rte:7.1.1.0::COMMITTED:PCI-X266 Dual-x4 3Gb SAS RAID Adapter Software 
devices.pci.1410be02.diag:7.1.0.0::COMMITTED:PCI-X DDR Dual Channel U320 SCSI RAID Adapter Diagnostics
devices.pci.1410be02.rte:7.1.0.0::COMMITTED:PCI-XDDR Dual Channel U320 SCSI RAID Adapter Software
devices.pci.1410bf02.diag:7.1.0.0::COMMITTED:PCI-X DDR Quad Channel U320 SCSI RAID Adapter Diagnostics
devices.pci.1410bf02.rte:7.1.0.0::COMMITTED:PCI-XDDR Quad Channel U320 SCSI RAID Adapter Software
devices.pci.1410c002.diag:7.1.0.0::COMMITTED:PCI-X DDR Dual Channel U320 SCSI Adapter Diagnostics
devices.pci.1410c002.rte:7.1.0.0::COMMITTED:PCI-XDDR Dual Channel U320 SCSI Adapter Software
devices.pci.1410c101.diag:7.1.0.0::COMMITTED:64bit/66MHz PCI ATM 155 UTP Adapter Diagnostics
devices.pci.1410c101.rte:7.1.0.0::COMMITTED:64bit/66MHz PCI ATM 155 UTP Adapter Software
devices.pci.1410c302.diag:7.1.0.0::COMMITTED:PCI-X266 Ext Tri-x4 3Gb SAS RAID Adapter Diagnostics 
devices.pci.1410c302.rte:7.1.1.0::COMMITTED:PCI-X266 Ext Tri-x4 3Gb SAS RAID Adapter Software 
devices.pci.1410cf02.diag:7.1.0.0::COMMITTED:1000 Base-SX PCI-X iSCSI TOE Adapter Device Diagnostics
devices.pci.1410cf02.rte:7.1.0.0::COMMITTED:1000 Base-SX PCI-X iSCSI TOE Adapter Device Software
devices.pci.1410d002.com:7.1.4.30::COMMITTED:Common PCI iSCSI TOE Adapter Device Software 
devices.pci.1410d002.diag:7.1.4.30::COMMITTED:1000 Base-TX PCI-X iSCSI TOE Adapter Device Diagnostics 
devices.pci.1410d002.rte:7.1.0.0::COMMITTED:1000 Base-TX PCI-X iSCSI TOE Adapter Device Software 
devices.pci.1410d302.diag:7.1.0.0::COMMITTED:PCI-X Dual Channel Ultra320 SCSI Adapter Diagnostics
devices.pci.1410d302.rte:7.1.0.0::COMMITTED:PCI-X Dual Channel U320 SCSI Adapter Software
devices.pci.1410d402.diag:7.1.0.0::COMMITTED:PCI-X Dual Channel U320 SCSI RAID Adapter Diagnostics
devices.pci.1410d402.rte:7.1.0.0::COMMITTED:PCI-X Dual Channel U320 SCSI RAID Adapter Software
devices.pci.1410d403.rte:7.1.1.15::COMMITTED:Native 1-Port Asynchronous EIA-232 PCI Adapter Software 
devices.pci.1410d502.diag:7.1.0.0::COMMITTED:PCI-X DDR Quad Channel U320 SCSI RAID Adapter Diagnostics
devices.pci.1410d502.rte:7.1.0.0::COMMITTED:PCI-XDDR Quad Channel U320 SCSI RAID Adapter Software
devices.pci.1410e202.diag:7.1.0.0::COMMITTED:IBM 1 Gigabit-SX iSCSI TOE PCI-X Adapter Diagnostics
devices.pci.1410e202.rte:7.1.0.0::COMMITTED:IBM 1 Gigabit-SX iSCSI TOE PCI-X Adapter
devices.pci.1410e501.diag:7.1.0.0::COMMITTED:IBM PCI-X 4764 Cryptographic Coprocessor Card Diagnostics 
devices.pci.1410e501.rte:7.1.3.0::COMMITTED:IBM PCI-X Cryptographic Coprocessor 
devices.pci.1410e601.diag:7.1.0.0::COMMITTED:IBM Cryptographic Accelerator Diagnostics 
devices.pci.1410e601.rte:7.1.3.0::COMMITTED:IBM Crypto Accelerator Adapter Software 
devices.pci.1410eb02.diag:7.1.3.0::COMMITTED:10 Gigabit Ethernet-SR PCI-X 2.0 DDR Adapter Diagnostics 
devices.pci.1410eb02.rte:7.1.0.15::COMMITTED:10 Gigabit Ethernet-SR PCI-X 2.0 DDR Adapter Software 
devices.pci.1410ec02.diag:7.1.0.0::COMMITTED:10 Gigabit Ethernet-LR PCI-X 2.0 DDR Adapter Diagnostics 
devices.pci.1410ec02.rte:7.1.4.0::COMMITTED:10 Gigabit Ethernet-LR PCI-X 2.0 DDR Adapter Software 
devices.pci.1410ff01.diag:7.1.3.0::COMMITTED:10/100 Mbps Ethernet PCI Adapter II Diagnostics 
devices.pci.1410ff01.rte:7.1.4.0::COMMITTED:10/100 Mbps Ethernet PCI Adapter II Software 
devices.pci.22106474.diag:7.1.0.0::COMMITTED:USB Host Controller (22106474) Diagnostics 
devices.pci.22106474.rte:7.1.4.0::COMMITTED:USB Host Controller (22106474) Software 
devices.pci.22106974.rte:7.1.0.0::COMMITTED:IDE Adapter Driver for AMD 8111 Chip Software
devices.pci.23100020.diag:7.1.3.0::COMMITTED:IBM PCI 10/100 Mb Ethernet Adapter (23100020) Diagnostics 
devices.pci.23100020.rte:7.1.4.0::COMMITTED:IBM PCI 10/100 Ethernet Adapter Software 
devices.pci.2b102725.X11:7.1.1.0::COMMITTED:AIXwindows GXT145 Graphics Adapter Software 
devices.pci.2b102725.diag:7.1.2.15::COMMITTED:GXT145 2D Graphics Adapter Diagnostics 
devices.pci.2b102725.rte:7.1.4.0::COMMITTED:GXT145 Graphics Adapter Software 
devices.pci.33103500.diag:7.1.0.0::COMMITTED:USB Host Controller (33103500) Diagnostics 
devices.pci.33103500.rte:7.1.4.0::COMMITTED:USB Host Controller (33103500) Software 
devices.pci.3310e000.diag:7.1.0.0::COMMITTED:USB Enhanced Host Controller (3310e000) Diagnostics 
devices.pci.3310e000.rte:7.1.4.0::COMMITTED:USB Enhanced Host Controller Adapter (3310e000) Software 
devices.pci.331121b9.com:7.1.3.0::COMMITTED:IBM PCI 2-Port Multiprotocol Common Software 
devices.pci.331121b9.diag:7.1.3.0::COMMITTED:PCI 2-Port Multiprotocol Adapter (331121b9) Diagnostics 
devices.pci.331121b9.rte:7.1.3.0::COMMITTED:IBM PCI 2-Port Multiprotocol Device Driver 
devices.pci.4f111100.asw:7.1.0.0::COMMITTED:PCI 8-Port Asynchronous Adapter Software 
devices.pci.4f111100.com:7.1.4.0::COMMITTED:Common PCI Asynchronous Adapter Software 
devices.pci.4f111100.diag:7.1.3.0::COMMITTED:RISC PC PCI Async 8 Port Adapter Diagnostics 
devices.pci.4f111100.rte:7.1.0.0::COMMITTED:PCI 8-Port Asynchronous Adapter Software 
devices.pci.4f111b00.asw:7.1.0.0::COMMITTED:PCI 128-Port Asynchronous Adapter Software
devices.pci.4f111b00.diag:7.1.0.0::COMMITTED:RISC PC PCI Async 128 Port Adapter Diagnostics
devices.pci.4f111b00.rte:7.1.0.0::COMMITTED:PCI 128-Port Asynchronous Adapter Software
devices.pci.4f11c800.diag:7.1.3.0::COMMITTED:2-port Asynchronous EIA-232 PCI Adapter Diagnostics 
devices.pci.4f11c800.rte:7.1.4.30::COMMITTED:2-Port Asynchronous EIA-232 PCI Adapter Software 
devices.pci.5a107512.rte:7.1.0.0::COMMITTED:IDE Adapter Driver for Promise 275 Chip Software
devices.pci.77101223.com:7.1.4.0::COMMITTED:PCI FC Adapter (77101223) Common Software 
devices.pci.77101223.diag:7.1.4.30::COMMITTED:PCI FC Adapter (77101223) Diagnostics 
devices.pci.77101223.rte:7.1.0.0::COMMITTED:PCI FC Adapter (77101223) Runtime Software 
devices.pci.77102224.com:7.1.4.30::COMMITTED:PCI-X FC Adapter (77102224) Common Software 
devices.pci.77102224.diag:7.1.2.0::COMMITTED:PCI-X FC Adapter (77102224) Diagnostics 
devices.pci.77102224.rte:7.1.4.0::COMMITTED:PCI-X FC Adapter (77102224) Runtime Software 
devices.pci.77102e01.diag:7.1.0.0::COMMITTED:1000 Base-TX PCI-X iSCSI TOE Adapter Device Diagnostics
devices.pci.77102e01.rte:7.1.0.0::COMMITTED:PCI-X 1000 Base-TX iSCSI TOE Adapter Device Software
devices.pci.99172604.diag:7.1.0.0::COMMITTED:USB Enhanced Host Controller (99172604) Diagnostics 
devices.pci.99172604.rte:7.1.3.15::COMMITTED:USB Enhanced Host Controller Adapter (99172604) Software 
devices.pci.99172704.diag:7.1.0.0::COMMITTED:USB Host Controller (99172704) Diagnostics 
devices.pci.99172704.rte:7.1.4.0::COMMITTED:USB Host Controller (99172704) Software 
devices.pci.a8135201.diag:7.1.0.0::COMMITTED:2-port Asynchronous EIA-232 PCI Adapter Diagnostics 
devices.pci.a8135201.rte:7.1.1.15::COMMITTED:Native 2-Port Asynchronous EIA-232 PCI Adapter Software 
devices.pci.ad100501.rte:7.1.4.0::COMMITTED:IDE Adapter Driver for Winbond 553F Chip Software 
devices.pci.c1110358.diag:7.1.0.0::COMMITTED:USB Open Host Controller Adapter Diagnostics 
devices.pci.c1110358.rte:7.1.4.0::COMMITTED:USB Host Controller (c1110358) Software 
devices.pci.df1000f7.com:7.1.4.30::COMMITTED:Common PCI FC Adapter Device Software 
devices.pci.df1000f7.diag:7.1.4.30::COMMITTED:PCI FC Adapter Device Diagnostics 
devices.pci.df1000f7.rte:7.1.0.0::COMMITTED:PCI FC Adapter Device Software 
devices.pci.df1000f9.diag:7.1.0.0::COMMITTED:64-bit PCI FC Adapter Device Diagnostics
devices.pci.df1000f9.rte:7.1.0.0::COMMITTED:64-bit PCI FC Adapter Device Software
devices.pci.df1000fa.diag:7.1.0.0::COMMITTED:FC PCI-X Adapter Device Diagnostics
devices.pci.df1000fa.rte:7.1.0.0::COMMITTED:FC PCI-X Adapter Device Software
devices.pci.df1000fd.diag:7.1.0.0::COMMITTED:FC PCI-X Adapter Device Diagnostics
devices.pci.df1000fd.rte:7.1.0.0::COMMITTED:4Gb PCI-X FC Adapter Device Software
devices.pci.df1023fd.diag:7.1.0.0::COMMITTED:4Gb PCI-X FC Adapter (df1023fd) Device Diagnostics
devices.pci.df1023fd.rte:7.1.0.0::COMMITTED:4Gb PCI-X FC Adapter (df1023fd) Device Software
devices.pci.df1080f9.diag:7.1.0.0::COMMITTED:PCI-X FC Adapter Device Diagnostics
devices.pci.df1080f9.rte:7.1.0.0::COMMITTED:PCI-X FC Adapter Device Software
devices.pci.e414a816.diag:7.1.3.0::COMMITTED:Gigabit Ethernet Adapter Diagnostics 
devices.pci.e414a816.rte:7.1.3.0::COMMITTED:Gigabit Ethernet-SX Adapter Software 
devices.pci.isa.rte:7.1.3.0::COMMITTED:ISA Bus Bridge Software (CHRP) 
devices.pci.pci.rte:7.1.0.0::COMMITTED:PCI Bus Bridge Software (CHRP)
devices.pciex.001072001410ea03.diag:7.1.2.15::COMMITTED:PCIe2 SAS Adapter Dual-port 6Gb Device 
Diagnostics 
devices.pciex.001072001410ea03.rte:7.1.2.15::COMMITTED:PCIe2 SAS Adapter Dual-port 6Gb Device Software 
devices.pciex.001072001410f603.diag:7.1.2.15::COMMITTED:PCIe2 SAS Adapter Quad-port 6Gb Device 
Diagnostics 
devices.pciex.001072001410f603.rte:7.1.2.15::COMMITTED:PCIe2 SAS Adapter Quad-port 6Gb Device Software 
devices.pciex.14103903.diag:7.1.3.0::COMMITTED:PCI Express 3Gb SAS RAID Adapter Diagnostics 
devices.pciex.14103903.rte:7.1.1.0::COMMITTED:PCI Express 3GB SAS RAID Adapter Software 
devices.pciex.14103d03.diag:7.1.4.30::COMMITTED:PCI Express 6GB SAS RAID Adapter Diagnostics 
devices.pciex.14103d03.rte:7.1.1.15::COMMITTED:PCI Express 6GB SAS RAID Adapter Software 
devices.pciex.14103f03.diag:7.1.4.30::COMMITTED:2-Port Gigabit Ethernet-SX PCI-Express Adapter 
Diagnostics 
devices.pciex.14103f03.rte:7.1.3.0::COMMITTED:2-Port Gigabit Ethernet-SX PCI-Express Adapter Software 
devices.pciex.14104003.diag:7.1.0.0::COMMITTED:2-Port 10/100/1000 Base-TX PCI-Express Adapter 
Diagnostics 
devices.pciex.14104003.rte:7.1.3.0::COMMITTED:2-Port 10/100/1000 Base-TX PCI-Express Adapter Software 
devices.pciex.14104a03.diag:7.1.4.0::COMMITTED:PCIe3 6GB SAS RAID Adapter Diagnostics 
devices.pciex.14104a03.rte:7.1.4.0::COMMITTED:PCIe3 6GB SAS RAID Adapter Software 
devices.pciex.14104b0414104b04.com:7.1.4.0::COMMITTED:Common PCIe FPGA Accelerator Adapter Device 
Software 
devices.pciex.14104b0414104b04.diag:7.1.4.0::COMMITTED:PCIe FPGA Accelrator Adapter Diagnostics 
devices.pciex.14104b0414104b04.rte:7.1.3.15::COMMITTED:PCIe FPGA Accelrator Adapter Device Software 
devices.pciex.1410660414100000.diag:7.1.4.30::COMMITTED:IBM 4767 PCIe3 Cryptographic Coprocessor 
(1410660414100000) Diagnostics Software 
devices.pciex.1410660414100000.rte:7.1.4.30::COMMITTED:IBM 4767 PCIe3 Cryptographic Coprocessor 
(1410660414100000) Device Software 
devices.pciex.14106803.diag:7.1.0.0::COMMITTED:4-Port 10/100/1000 Base-TX PCI Express Adapter 
Diagnostics 
devices.pciex.14106803.rte:7.1.3.0::COMMITTED:4-Port 10/100/1000 Base-TX PCI-Express Adapter Software 
devices.pciex.14107a0314107b03.diag:7.1.0.0::COMMITTED:IBM Y4 PCI-E Cryptographic CoProcessor Model 
4765 (14107a0314107b03) Diagnostics 
devices.pciex.14107a0314107b03.rte:7.1.4.30::COMMITTED:IBM Y4 PCI-E Cryptographic Coprocessor 
(14107a0314107b03) Device Software 
devices.pciex.151438c1.diag:7.1.4.0::COMMITTED:PCIe Async EIA-232 Controller Diagnostics 
devices.pciex.151438c1.rte:7.1.2.0::COMMITTED:PCIe Async EIA-232 Controller 
devices.pciex.2514300014108c03.diag:7.1.4.30::COMMITTED:10 Gigabit Ethernet-SR PCI Express Adapter 
Diagnostics Software (2514300014108c03) 
devices.pciex.2514300014108c03.rte:7.1.2.15::COMMITTED:10 Gigabit Ethernet-SR PCI-Express Host Bus 
Adapter 
devices.pciex.251430001410a303.diag:7.1.0.0::COMMITTED:10 Gigabit Ethernet-CX4 PCI Express Adapter 
Diagnostics Software (251430001410a303) 
devices.pciex.251430001410a303.rte:7.1.2.15::COMMITTED:10 Gigabit Ethernet-CX4 PCI-Express Host Bus 
Adapter 
devices.pciex.2514310025140100.diag:7.1.0.0::COMMITTED:10 Gigabit Ethernet PCI-Express Host Bus Adapter 
Diagnostics Software (2514310025140100) 
devices.pciex.2514310025140100.rte:7.1.2.15::COMMITTED:10 Gigabit Ethernet PCI-Express Host Bus Adapter 
devices.pciex.4c10418214109e04.diag:7.1.3.15::COMMITTED:PCIe2 USB 3.0 xHCI 4-Port Adapter Device 
Diagnostics 
devices.pciex.4c10418214109e04.rte:7.1.4.0::COMMITTED:PCIe2 USB 3.0 xHCI 4-Port Adapter Device Software 
devices.pciex.4c1041821410b204.diag:7.1.3.15::COMMITTED:Integrated PCIe2 USB 3.0 xHCI Controller Device 
Diagnostics 
devices.pciex.4c1041821410b204.rte:7.1.4.0::COMMITTED:Integrated PCIe2 USB 3.0 xHCI Controller Device 
Software 
devices.pciex.4f11f60014102204.diag:7.1.1.0::COMMITTED:PCIe 2-port Async EIA-232 Adapter Diagnostics 
devices.pciex.4f11f60014102204.rte:7.1.2.0::COMMITTED:PCIe 2-port Async EIA-232 Adapter 
devices.pciex.771000801410b003.diag:7.1.0.0::COMMITTED:10 Gb FCoE PCI Express Dual Port Adapter 
Diagnostics 
devices.pciex.771000801410b003.rte:7.1.4.0::COMMITTED:10 Gb Ethernet-SR PCI Express Dual Port Adapter 
Software 
devices.pciex.7710008077108001.diag:7.1.0.0::COMMITTED:10 Gb FCoE PCI Express Dual Port Adapter 
Diagnostics
devices.pciex.7710008077108001.rte:7.1.0.0::COMMITTED:10 Gb Ethernet PCI Express Dual Port Adapter 
Software
devices.pciex.771001801410af03.diag:7.1.4.30::COMMITTED:10 Gb FCoE PCI Express Dual Port Adapter 
(771001801410af03) Diagnostics 
devices.pciex.771001801410af03.rte:7.1.3.15::COMMITTED:10 Gb FCoE PCI Express Dual Port Adapter 
(771001801410af03) Device Software 
devices.pciex.7710018077107f01.diag:7.1.2.0::COMMITTED:10 Gb FCoE PCIe Blade Expansion Card 
(7710018077107f01) Diagnostics 
devices.pciex.7710018077107f01.rte:7.1.2.0::COMMITTED:10 Gb FCoE PCIe Blade Expansion Card 
(7710018077107f01) Device Software 
devices.pciex.77103224.diag:7.1.2.0::COMMITTED:PCI Express FC Adapter Diagnostics (77103224) 
devices.pciex.77103224.rte:7.1.4.0::COMMITTED:PCI Express 4Gb FC Adapter (77103224) Device Software 
devices.pciex.77103225141004f3.diag:7.1.4.30::COMMITTED:8Gb 2-Port PCIe2 FC (77103225141004f3) 
Diagnostics Software 
devices.pciex.77103225141004f3.rte:7.1.4.30::COMMITTED:8Gb 2-Port PCIe2 FC (77103225141004f3) Runtime 
Software 
devices.pciex.7710322514101e04.diag:7.1.1.15::COMMITTED:Low Profile 8Gb 4-Port PCIe2 FC 
(7710322514101e04) Diagnostic Software 
devices.pciex.7710322514101e04.rte:7.1.4.30::COMMITTED:Low Profile 8Gb 4-Port PCIe2 FC 
(7710322514101e04) Device Software 
devices.pciex.7710322577106501.diag:7.1.2.0::COMMITTED:4Gb PCIe FC Blade Expansion Card 
(7710322577106501) Diagnostics 
devices.pciex.7710322577106501.rte:7.1.2.0::COMMITTED:4Gb PCIe FC Blade Expansion Card 
(7710322577106501) Device Software 
devices.pciex.7710322577106601.diag:7.1.2.0::COMMITTED:8Gb PCIe FC Blade Expansion Card 
(7710322577106601) Diagnostic Software 
devices.pciex.7710322577106601.rte:7.1.2.0::COMMITTED:8Gb PCIe FC Blade Expansion Card 
(7710322577106601) Device Software 
devices.pciex.7710322577106801.diag:7.1.2.0::COMMITTED:8Gb PCIe FC Blade Expansion Card 
(7710322577106801) Diagnostics 
devices.pciex.7710322577106801.rte:7.1.2.0::COMMITTED:8Gb PCIe FC Blade Expansion Card 
(7710322577106801) Device Software 
devices.pciex.7710322577107501.diag:7.1.2.0::COMMITTED:Dual Port 8Gb FC Mezzanine Card 
(7710322577107501) Diagnostic Software 
devices.pciex.7710322577107501.rte:7.1.3.15::COMMITTED:Dual Port 8Gb FC Mezzanine Card 
(7710322577107501) Device Software 
devices.pciex.7710322577107601.diag:7.1.2.0::COMMITTED:8Gb PCIe FC Blade Expansion Card 
(7710322577107601) Diagnostics 
devices.pciex.7710322577107601.rte:7.1.2.0::COMMITTED:8Gb PCIe FC Blade Expansion Card 
(7710322577107601) Device Software 
devices.pciex.8680c71014108003.diag:7.1.4.30::COMMITTED:10 Gigabit Ethernet-LR PCI-Express Adapter 
Diagnostics 
devices.pciex.8680c71014108003.rte:7.1.4.30::COMMITTED:10 Gigabit Ethernet-LR PCI-Express Adapter 
Software 
devices.pciex.a219100714100904.diag:7.1.1.0::COMMITTED:Int Multifunction Card w/ SR Optical 10GbE 
Adapter Diagnostics 
devices.pciex.a219100714100904.rte:7.1.4.0::COMMITTED:Int Multifunction Card w/ SR Optical 10GbE 
Adapter Software 
devices.pciex.a219100714100a04.diag:7.1.1.0::COMMITTED:Int Multifunction Card w/ Copper SFP+ 10GbE 
Adapter Diagnostics 
devices.pciex.a219100714100a04.rte:7.1.4.0::COMMITTED:Int Multifunction Card w/ Copper SFP+ 10GbE 
Adapter Software 
devices.pciex.a21910071410d003.diag:7.1.4.30::COMMITTED:PCIe2 2-port 10GbE SR Adapter Diagnostics 
devices.pciex.a21910071410d003.rte:7.1.4.30::COMMITTED:PCIe2 2-port 10GbE SR Adapter Software 
devices.pciex.a21910071410d103.diag:7.1.0.0::COMMITTED:PCIe2 2-port 10GbE SFP Copper Adapter 
Diagnostics 
devices.pciex.a21910071410d103.rte:7.1.4.0::COMMITTED:PCIe2 2-port 10GbE SFP+Copper Adapter Software 
devices.pciex.a21910071410d203.diag:7.1.1.0::COMMITTED:Int Multifunction Card w/ Base-TX Adapter 
Diagnostics 
devices.pciex.a21910071410d203.rte:7.1.4.0::COMMITTED:Int Multifunction Card w/ Base-TX 10/100/1000 
1GbE Adapter Software 
devices.pciex.a2191007df1033e7.diag:7.1.1.0::COMMITTED:10GbE 4 port PCIe2 Mezz Adapter Diagnostics 
devices.pciex.a2191007df1033e7.rte:7.1.4.0::COMMITTED:10GbE 4-port PCIe2 Mezz Adapter Software 
devices.pciex.b31503101410b504.diag:7.1.4.0::COMMITTED:RoCE Host Bus Adapter Diagnostics 
(b31503101410b504) 
devices.pciex.b31503101410b504.rte:7.1.4.30::COMMITTED:RoCE Host Bus Adapter (b31503101410b504) 
devices.pciex.b31507101410e704.diag:7.1.4.0::COMMITTED:RoCE Host Bus Adapter Diagnostics 
(b31507101410e704) 
devices.pciex.b31507101410e704.rte:7.1.4.30::COMMITTED:RoCE Host Bus Adapter (b31507101410e704) 
devices.pciex.b31507101410eb04.diag:7.1.4.0::COMMITTED:RoCE Host Bus Adapter Diagnostics 
(b31507101410eb04) 
devices.pciex.b31507101410eb04.rte:7.1.4.30::COMMITTED:RoCE Host Bus Adapter (b31507101410eb04) 
devices.pciex.b31513101410f704.diag:7.1.4.30::COMMITTED:100Gbit RoCE PCIe3 Adapter Diagnostics 
(b31513101410f704) 
devices.pciex.b31513101410f704.rte:7.1.4.30::COMMITTED:PCIe3 100Gbit 2-port RoCE Adapter Software 
devices.pciex.b3153c67.diag:7.1.2.0::COMMITTED:PCIe Dual Port HCA QDR Infiniband Device Diagnostics 
devices.pciex.b3153c67.rte:7.1.4.0::COMMITTED:4X PCI-E QDR Infiniband Device Driver 
devices.pciex.b3154a63.diag:7.1.4.30::COMMITTED:PCI-E 4X DDR Infiniband Device Diagnostics 
devices.pciex.b3154a63.rte:7.1.4.30::COMMITTED:4X PCI-E DDR Infiniband Device Driver 
devices.pciex.b315506714101604.diag:7.1.4.0::COMMITTED:RoCE Host Bus Adapter Diagnostics 
(b315506714101604) 
devices.pciex.b315506714101604.rte:7.1.4.30::COMMITTED:RoCE Host Bus Adapter (b315506714101604) 
devices.pciex.b315506714106104.diag:7.1.4.0::COMMITTED:RoCE Host Bus Adapter Diagnostics 
(b315506714106104) 
devices.pciex.b315506714106104.rte:7.1.4.30::COMMITTED:RoCE Host Bus Adapter (b315506714106104) 
devices.pciex.b3155067b3157265.diag:7.1.4.0::COMMITTED:RoCE Host Bus Adapter Diagnostics 
(b3155067b3157265) 
devices.pciex.b3155067b3157265.rte:7.1.4.30::COMMITTED:RoCE Host Bus Adapter (b3155067b3157265) 
devices.pciex.b3155067b3157365.diag:7.1.4.0::COMMITTED:RoCE Host Bus Adapter Diagnostics 
(b3155067b3157365) 
devices.pciex.b3155067b3157365.rte:7.1.4.30::COMMITTED:RoCE Host Bus Adapter (b3155067b3157365) 
devices.pciex.df1000e214105e04.diag:7.1.2.0::COMMITTED:GX++ 16Gb FC 2 Port Adapter Diagnostics 
devices.pciex.df1000e214105e04.rte:7.1.3.0::COMMITTED:GX++ 16Gb FC 2 Port Adapter Device Software 
devices.pciex.df1000e21410f103.diag:7.1.2.0::COMMITTED:16Gb FC PCIe2 2 Port Adapter Diagnostics 
devices.pciex.df1000e21410f103.rte:7.1.4.30::COMMITTED:16Gb FC PCIe2 2 Port Adapter Device Software 
devices.pciex.df1000e2df1002e2.diag:7.1.2.0::COMMITTED:PCIe2 2-Port 16Gb FC Mezzanine Adapter 
Diagnostics 
devices.pciex.df1000e2df1002e2.rte:7.1.3.0::COMMITTED:PCIe2 2-Port 16Gb FC Mezzanine Adapter Device 
Software 
devices.pciex.df1000e2df1082e2.diag:7.1.2.15::COMMITTED:4-Port 16Gb FC Mezzanine Adapter Device 
Diagnostics 
devices.pciex.df1000e2df1082e2.rte:7.1.3.15::COMMITTED:4-Port 16Gb FC Mezzanine Adapter Device Software 
devices.pciex.df1000f114100104.diag:7.1.1.0::COMMITTED:8Gb FC PCI Express Quad Port Adapter Device 
Diagnostics 
devices.pciex.df1000f114100104.rte:7.1.3.15::COMMITTED:8Gb FC PCI Express Quad Port Adapter Device 
Software 
devices.pciex.df1000f114108a03.diag:7.1.0.0::COMMITTED:8Gb PCI-E FC Adapter (df1000f114108a03) Device 
Diagnostics 
devices.pciex.df1000f114108a03.rte:7.1.3.15::COMMITTED:8Gb FC PCI Express Dual Port Adapter Device 
Software 
devices.pciex.df1000f1df1024f1.diag:7.1.0.0::COMMITTED:8Gb PCI-E FC Adapter (df1000f1df1024f1) Device 
Diagnostics
devices.pciex.df1000f1df1024f1.rte:7.1.0.0::COMMITTED:8Gb PCIe FC Blade Expansion Card 
(df1000f1df1024f1) Device Software
devices.pciex.df1000fe.diag:7.1.0.0::COMMITTED:4Gb FC PCI Express Adapter Device Diagnostics 
devices.pciex.df1000fe.rte:7.1.3.15::COMMITTED:4Gb FC PCI Express Adapter Device Software 
devices.pciex.df1020e214100f04.diag:7.1.2.0::COMMITTED:PCIe2 10GbE SFP+ SR Adapter Diagnostics 
devices.pciex.df1020e214100f04.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ SR Adapter Software 
devices.pciex.df1020e214103604.diag:7.1.2.15::COMMITTED:PCIe2 10GbE SFP+ SR 4-port Adapter Diagnostics 
devices.pciex.df1020e214103604.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ SR 4-port Adapter Software 
devices.pciex.df1020e214103804.diag:7.1.2.15::COMMITTED:PCIe2 10GBaseT 4-port Adapter Diagnostics 
devices.pciex.df1020e214103804.rte:7.1.4.30::COMMITTED:PCIe2 10GBaseT 4-port Adapter Software 
devices.pciex.df1020e214103904.diag:7.1.2.15::COMMITTED:PCIe2 10GbE SFP+ Cu 4-port Adapter Diagnostics 
devices.pciex.df1020e214103904.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ Cu 4-port Adapter Software 
devices.pciex.df1020e214103b04.diag:7.1.2.15::COMMITTED:PCIe2 10GBaseT 4-port Adapter Diagnostics 
devices.pciex.df1020e214103b04.rte:7.1.4.30::COMMITTED:PCIe2 10GBaseT 4-port Adapter Software 
devices.pciex.df1020e214103c04.diag:7.1.2.0::COMMITTED:PCIe2 10/100/1000 Base-TX Adapter Diagnostics 
devices.pciex.df1020e214103c04.rte:7.1.4.30::COMMITTED:PCIe2 10/100/1000 Base-TX Adapter Software 
devices.pciex.df1020e214103d04.diag:7.1.3.0::COMMITTED:PCIe2 10GbE SFP+ Cu 4-port Adapter Diagnostics 
devices.pciex.df1020e214103d04.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ Cu Adapter Software 
devices.pciex.df1020e214103f04.diag:7.1.3.0::COMMITTED:PCIe2 1GbaseT SFP+ Cu 4-port Adapter Diagnostics 
devices.pciex.df1020e214103f04.rte:7.1.4.30::COMMITTED:PCIe2 100/1000 Base-TX Adapter Software 
devices.pciex.df1020e214104004.diag:7.1.3.15::COMMITTED:PCIe2 10GbE SFP+ LR 4-port Adapter Diagnostics 
devices.pciex.df1020e214104004.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ LR Adapter Software 
devices.pciex.df1020e214104204.diag:7.1.3.15::COMMITTED:PCIe2 100/1000 Base-TX Adapter Diagnostics 
devices.pciex.df1020e214104204.rte:7.1.4.30::COMMITTED:PCIe2 100/1000 Base-TX Adapter Software 
devices.pciex.df1020e214105104.diag:7.1.2.0::COMMITTED:PCIe2 10GbE Mezz Adapter Diagnostics 
devices.pciex.df1020e214105104.rte:7.1.4.30::COMMITTED:PCIe2 10GbE Mezz Adapter Software 
devices.pciex.df1020e214105d04.diag:7.1.2.0::COMMITTED:PCIe2 10GbE 2-port GX++ Gen2 Converged Network 
Adapter Diagnostics 
devices.pciex.df1020e214105d04.rte:7.1.4.30::COMMITTED:PCIe2 10GbE 2-port GX++ Gen2 Converged Network 
Adapter Software 
devices.pciex.df1020e21410e304.diag:7.1.4.0::COMMITTED:PCIe3 4-Port 10GbE SR Adapter Diagnostics 
devices.pciex.df1020e21410e304.rte:7.1.4.30::COMMITTED:PCIe3 4-Port 10GbE SR Adapter 
devices.pciex.df1020e21410e404.diag:7.1.4.0::COMMITTED:PCIe3 4-Port 10GbE CU Adapter Diagnostics 
devices.pciex.df1020e21410e404.rte:7.1.4.30::COMMITTED:PCIe3 4-Port 10GbE CU Adapter 
devices.pciex.df1028e214100f04.diag:7.1.3.0::COMMITTED:PCIe2 10GbE SFP+ SR VF Adapter Diagnostics 
devices.pciex.df1028e214100f04.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ SR VF Adapter Software 
devices.pciex.df1028e214103604.diag:7.1.3.0::COMMITTED:PCIe2 10GbE SFP+ SR 4-port VF Adapter 
Diagnostics 
devices.pciex.df1028e214103604.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ SR 4-port VF Adapter Software 
devices.pciex.df1028e214103804.diag:7.1.3.0::COMMITTED:PCIe2 10GBaseT 4-port VF Adapter Diagnostics 
devices.pciex.df1028e214103804.rte:7.1.4.30::COMMITTED:PCIe2 10GBaseT 4-port VF Adapter Software 
devices.pciex.df1028e214103904.diag:7.1.3.0::COMMITTED:PCIe2 10GbE SFP+ Cu 4-port VF Adapter 
Diagnostics 
devices.pciex.df1028e214103904.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ Cu 4-port VF Adapter Software 
devices.pciex.df1028e214103b04.diag:7.1.3.0::COMMITTED:PCIe2 10GBaseT 4-port VF Adapter Diagnostics 
devices.pciex.df1028e214103b04.rte:7.1.4.30::COMMITTED:PCIe2 10GBaseT 4-port VF Adapter Software 
devices.pciex.df1028e214103c04.diag:7.1.3.0::COMMITTED:PCIe2 10/100/1000 Base-TX VF Adapter Diagnostics 
devices.pciex.df1028e214103c04.rte:7.1.4.30::COMMITTED:PCIe2 10/100/1000 Base-TX VF Adapter Software 
devices.pciex.df1028e214103d04.diag:7.1.3.0::COMMITTED:PCIe2 10GbE SFP+ Cu 4-port VF Adapter 
Diagnostics 
devices.pciex.df1028e214103d04.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ Cu VF Adapter Software 
devices.pciex.df1028e214103f04.diag:7.1.3.0::COMMITTED:PCIe2 1GbaseT SFP+ Cu 4-port VF Adapter 
Diagnostics 
devices.pciex.df1028e214103f04.rte:7.1.4.30::COMMITTED:PCIe2 100/1000 Base-TX VF Adapter Software 
devices.pciex.df1028e214104004.diag:7.1.3.15::COMMITTED:PCIe2 10GbE SFP+ LR VF Adapter Diagnostics 
devices.pciex.df1028e214104004.rte:7.1.4.30::COMMITTED:PCIe2 10GbE SFP+ LR VF Adapter Software 
devices.pciex.df1028e214104204.diag:7.1.3.15::COMMITTED:PCIe2 100/1000 Base-TX VF Adapter Diagnostics 
devices.pciex.df1028e214104204.rte:7.1.4.30::COMMITTED:PCIe2 100/1000 Base-TX VF Adapter Software 
devices.pciex.df1028e21410e304.diag:7.1.4.0::COMMITTED:PCIe3 4-Port 10GbE SR VF Adapter Diagnostics 
devices.pciex.df1028e21410e304.rte:7.1.4.30::COMMITTED:PCIe3 4-Port 10GbE SR VF Adapter Software 
devices.pciex.df1028e21410e404.diag:7.1.4.0::COMMITTED:PCIe3 4-Port 10GbE CU VF Adapter Diagnostics 
devices.pciex.df1028e21410e404.rte:7.1.4.30::COMMITTED:PCIe3 4-Port 10GbE CU VF Adapter Software 
devices.pciex.df1060e214101004.diag:7.1.2.0::COMMITTED:PCIe2 10GbE FCoE 4 Port Adapter Diagnostics 
devices.pciex.df1060e214101004.rte:7.1.4.30::COMMITTED:10Gb FCoE PCIe2 4 Port Adapter Device Software 
devices.pciex.df1060e214103404.com:7.1.4.30::COMMITTED:Common PCIe2 FC Adapter Device Software 
devices.pciex.df1060e214103404.diag:7.1.4.30::COMMITTED:PCIe2 10Gb 4-Port FCoE Mezzanine Adapter Device 
Diagnostics 
devices.pciex.df1060e214103404.rte:7.1.2.0::COMMITTED:PCIe2 10Gb 4-Port FCoE Mezzanine Adapter Device 
Software 
devices.pciex.df1060e214103704.diag:7.1.3.0::COMMITTED:Integrated 10Gb 4-Port FCoE Adapter Device 
Diagnostics 
devices.pciex.df1060e214103704.rte:7.1.4.30::COMMITTED:Integrated 10Gb 4-Port FCoE Adapter Device 
Software 
devices.pciex.df1060e214103a04.diag:7.1.3.0::COMMITTED:Integrated 10Gb Cu 4-Port FCoE Adapter Device 
Diagnostics 
devices.pciex.df1060e214103a04.rte:7.1.4.30::COMMITTED:Integrated 10Gb Cu 4-Port FCoE Adapter Device 
Software 
devices.pciex.df1060e214103e04.diag:7.1.3.15::COMMITTED:PCIe2 10GbE Cu 4-port FCoE Adapter Diagnostics 
devices.pciex.df1060e214103e04.rte:7.1.4.30::COMMITTED:PCIe2 10Gb Cu 4-Port FCoE Adapter Device 
Software 
devices.pciex.df1060e214104104.diag:7.1.3.15::COMMITTED:PCIe2 10Gb LR 4-Port FCoE Adapter Device 
Diagnostics 
devices.pciex.df1060e214104104.rte:7.1.4.30::COMMITTED:PCIe2 10Gb LR 4-Port FCoE Adapter Device 
Software 
devices.pciex.df1060e214105204.diag:7.1.2.0::COMMITTED:PCIe2 10GbE FCoE Mezz Adapter Diagnostics 
devices.pciex.df1060e214105204.rte:7.1.3.0::COMMITTED:PCIe2 10Gb FCoE Mezzanine Adapter Device Software 
devices.pciex.df1060e214105f04.diag:7.1.2.0::COMMITTED:GX++ 10Gb FCoE Adapter Diagnostics 
devices.pciex.df1060e214105f04.rte:7.1.3.0::COMMITTED:GX++ 10Gb FCoE Adapter Device Software 
devices.pciex.e4143a161410a003.diag:7.1.0.0::COMMITTED:2-Port Gigabit Ethernet Combo PCI-Express 
Adapter Diagnostics 
devices.pciex.e4143a161410a003.rte:7.1.0.0::COMMITTED:2-Port Gigabit Ethernet Combo PCI-Express Adapter 
Software 
devices.pciex.e4143a161410ed03.diag:7.1.0.0::COMMITTED:2-Port Integrated Gigabit Ethernet PCI-Express 
Adapter Diagnostics 
devices.pciex.e4143a161410ed03.rte:7.1.0.0::COMMITTED:2-Port Integrated Gigabit Ethernet PCI-Express 
Adapter Software 
devices.pciex.e4143a16e4140909.diag:7.1.0.0::COMMITTED:2-Port Gigabit Ethernet PCI-Express Adapter 
Diagnostics
devices.pciex.e4143a16e4140909.rte:7.1.0.0::COMMITTED:2-Port Gigabit Ethernet PCI-Express Adapter 
Software
devices.pciex.e4143a16e4143009.diag:7.1.3.0::COMMITTED:4-Port Gigabit Ethernet PCI-Express Adapter 
Diagnostics 
devices.pciex.e4143a16e4143009.rte:7.1.4.30::COMMITTED:4-Port Gigabit Ethernet PCI-Express Adapter 
Software 
devices.pciex.e4145616e4140518.diag:7.1.4.30::COMMITTED:2-Port Gigabit Ethernet PCI-Express Adapter 
Diagnostics 
devices.pciex.e4145616e4140518.rte:7.1.4.30::COMMITTED:2-Port Gigabit Ethernet PCI-Express Adapter 
Software 
devices.pciex.e4145616e4140528.diag:7.1.2.0::COMMITTED:2-Port Gigabit Ethernet PCI-Express Adapter 
Diagnostics 
devices.pciex.e4145616e4140528.rte:7.1.4.0::COMMITTED:2-Port Gigabit Ethernet PCI-Express Adapter 
Software 
devices.pciex.e414571614102004.diag:7.1.1.15::COMMITTED:4-Port Gigabit Ethernet PCI-Express Adapter 
Diagnostics 
devices.pciex.e414571614102004.rte:7.1.4.30::COMMITTED:4-Port Gigabit Ethernet PCI-Express Adapter 
Software 
devices.pciex.e4148a1614109304.diag:7.1.4.0::COMMITTED:PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter 
Diagnostics 
devices.pciex.e4148a1614109304.rte:7.1.4.30::COMMITTED:PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter 
devices.pciex.e4148a1614109404.diag:7.1.4.0::COMMITTED:PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter 
Diagnostics 
devices.pciex.e4148a1614109404.rte:7.1.4.30::COMMITTED:PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter 
devices.pciex.e4148e1614109204.diag:7.1.4.30::COMMITTED:PCIe2 2-Port 10GbE Base-T Adapter Diagnostics 
devices.pciex.e4148e1614109204.rte:7.1.4.30::COMMITTED:PCIe2 2-Port 10GbE Base-T Adapter 
devices.sas.diag:7.1.4.30::COMMITTED:Serial Attached SCSI Device Diagnostics 
devices.sas.rte:7.1.4.30::COMMITTED:Serial Attached SCSI Device Software 
devices.sata.diag:7.1.2.0::COMMITTED:Serial ATA Device Diagnostics 
devices.sata.rte:7.1.0.15::COMMITTED:Serial ATA Device Software 
devices.scsi.disk.diag.com:7.1.4.30::COMMITTED:Common Disk Diagnostic Service Aid 
devices.scsi.disk.diag.rte:7.1.4.30::COMMITTED:SCSI CD_ROM, Disk Device Diagnostics 
devices.scsi.disk.rspc:7.1.0.0::COMMITTED:RISC PC SCSI CD-ROM, Disk, Read/Write Optical Software 
devices.scsi.disk.rte:7.1.4.30::COMMITTED:SCSI CD-ROM, Disk, Read/Write Optical Device Software 
devices.scsi.safte.diag:7.1.0.0::COMMITTED:SCSI Accessed Fault-Tolerant Enclosure Device Diagnostics
devices.scsi.safte.rte:7.1.0.0::COMMITTED:SCSI Accessed Fault-Tolerant Enclosure Device Software
devices.scsi.ses.diag:7.1.4.30::COMMITTED:SCSI Enclosure Services Device Diagnostics 
devices.scsi.ses.rte:7.1.4.0::COMMITTED:SCSI Enclosure Device Software 
devices.scsi.tape.diag:7.1.1.15::COMMITTED:SCSI Tape Device Diagnostics 
devices.scsi.tape.rspc:7.1.0.0::COMMITTED:RISC PC SCSI Tape Device Software 
devices.scsi.tape.rte:7.1.4.0::COMMITTED:SCSI Tape Device Software 
devices.scsi.tm.rte:7.1.3.0::COMMITTED:SCSI Target Mode Software 
devices.serial.sb1.X11:7.1.0.0::COMMITTED:AIXwindows 6094-030 Spaceball 3-D Input Device Software
devices.serial.tablet1.X11:7.1.0.0::COMMITTED:AIXwindows Serial Tablet Input Device Software
devices.tty.rte:7.1.4.0::COMMITTED:TTY Device Driver Support Software 
devices.usbif.010100.rte:7.1.4.0::COMMITTED:USB Audio Device Driver 
devices.usbif.03000008.rte:7.1.3.15::COMMITTED:USB 3D Mouse Client Driver 
devices.usbif.030101.rte:7.1.4.30::COMMITTED:USB Keyboard Client Driver 
devices.usbif.030102.rte:7.1.4.30::COMMITTED:USB Mouse Client Driver 
devices.usbif.08025002.diag:7.1.4.0::COMMITTED:USB Mass Storage Diagnostics 
devices.usbif.08025002.rte:7.1.4.30::COMMITTED:USB Mass Storage Device Software 
devices.usbif.080400.diag:7.1.0.0::COMMITTED:USB Diskette Diagnostics 
devices.usbif.080400.rte:7.1.3.15::COMMITTED:USB Diskette Client Driver 
devices.usbif.usblibke.rte:7.1.4.30::COMMITTED:LIBUSB Device Support Software 
devices.vdevice.IBM.l-lan.rte:7.1.4.30::COMMITTED:Virtual I/O Ethernet Software 
devices.vdevice.IBM.v-scsi.rte:7.1.4.30::COMMITTED:Virtual SCSI Client Support 
devices.vdevice.IBM.vfc-client.rte:7.1.4.30::COMMITTED:Virtual Fibre Channel Client Support 
devices.vdevice.IBM.vnic.rte:7.1.4.30::COMMITTED:Virtual NIC Client Software 
devices.vdevice.hvterm-protocol.rte:7.1.0.0::COMMITTED:Virtual Terminal Physical Support
devices.vdevice.hvterm1.rte:7.1.4.0::COMMITTED:Virtual Terminal Devices 
devices.vdevice.vty-server.rte:7.1.4.0::COMMITTED:Virtual Terminal Devices 
expect.base:5.42.1.0::COMMITTED:Binary executable files of Expect
expect.man.en_US:5.42.1.0::COMMITTED:Expect man page documentation
infocenter.man.EN_US.commands:7.1.4.30::COMMITTED:AIX manual commands - U.S. English
infocenter.man.EN_US.files:7.1.4.30::COMMITTED:AIX manual files - U.S. English
infocenter.man.EN_US.libs:7.1.4.30::COMMITTED:AIX manual libs - U.S. English
invscout.com:2.2.0.1::COMMITTED:Inventory Scout Microcode Catalog
invscout.ldb:2.2.0.2::COMMITTED:Inventory Scout Logic Database
invscout.msg.en_US.rte:2.1.0.2::COMMITTED:Inventory Scout Messages - U.S. English
invscout.rte:2.2.0.20::COMMITTED:Inventory Scout Runtime
lsof.base:6.1.0.4850::COMMITTED:List Of Open Files
lsof.license:6.1.0.4850::COMMITTED:List Of Open Files
lsof.man.en_US:6.1.0.4850::COMMITTED:List Of Open Files Documentation - U.S. English
mcr.rte:7.1.4.30::COMMITTED:Metacluster Checkpoint and Restart 
openssh.base.client:7.1.101.5000::COMMITTED:Open Secure Shell Commands
openssh.base.server:7.1.101.5000::COMMITTED:Open Secure Shell Server
openssh.man.en_US:7.1.101.5000::COMMITTED:Open Secure Shell Documentation - U.S. English
openssh.msg.en_US:7.1.101.5000::COMMITTED:Open Secure Shell Messages - U.S. English
openssl.base:1.0.2.1000::COMMITTED:Open Secure Socket Layer
openssl.license:1.0.2.1000::COMMITTED:Open Secure Socket License
openssl.man.en_US:1.0.2.1000::COMMITTED:Open Secure Socket Layer
perfagent.server:7.1.4.0::COMMITTED:Performance Agent Daemons & Utilities 
perfagent.tools:7.1.4.30::COMMITTED:Local Performance Analysis & Control Commands 
perl.libext:2.3.0.15::COMMITTED:Perl Library Extensions 
perl.rte:5.10.1.250::COMMITTED:Perl Version 5 Runtime Environment
printers.msg.en_US.rte:7.1.3.0::COMMITTED:Printer Backend Messages - U.S. English 
printers.rte:7.1.4.30::COMMITTED:Printer Backend 
rpm.rte:3.0.5.52::COMMITTED:RPM Package Manager
rsct.basic.hacmp:3.2.1.10::COMMITTED:RSCT Basic Function (HACMP/ES Support)
rsct.basic.rte:3.2.1.11::COMMITTED:RSCT Basic Function
rsct.basic.sp:3.2.1.10::COMMITTED:RSCT Basic Function (PSSP Support)
rsct.compat.basic.hacmp:3.2.1.10::COMMITTED:RSCT Event Management Basic Function (HACMP/ES Support)
rsct.compat.basic.rte:3.2.1.10::COMMITTED:RSCT Event Management Basic Function
rsct.compat.basic.sp:3.2.1.10::COMMITTED:RSCT Event Management Basic Function (PSSP Support)
rsct.compat.clients.hacmp:3.2.1.10::COMMITTED:RSCT Event Management Client Function (HACMP/ES Support)
rsct.compat.clients.rte:3.2.1.10::COMMITTED:RSCT Event Management Client Function
rsct.compat.clients.sp:3.2.1.10::COMMITTED:RSCT Event Management Client Function (PSSP Support)
rsct.core.auditrm:3.2.1.10::COMMITTED:RSCT Audit Log Resource Manager
rsct.core.errm:3.2.1.10::COMMITTED:RSCT Event Response Resource Manager
rsct.core.fsrm:3.2.1.10::COMMITTED:RSCT File System Resource Manager
rsct.core.gui:3.2.1.10::COMMITTED:RSCT Graphical User Interface
rsct.core.hostrm:3.2.1.11::COMMITTED:RSCT Host Resource Manager
rsct.core.lprm:3.2.1.10::COMMITTED:RSCT Least Privilege Resource Manager
rsct.core.microsensor:3.2.1.10::COMMITTED:RSCT MicroSensor Resource Manager
rsct.core.rmc:3.2.1.11::COMMITTED:RSCT Resource Monitoring and Control
rsct.core.sec:3.2.1.10::COMMITTED:RSCT Security
rsct.core.sensorrm:3.2.1.10::COMMITTED:RSCT Sensor Resource Manager
rsct.core.sr:3.2.1.10::COMMITTED:RSCT Registry
rsct.core.utils:3.2.1.11::COMMITTED:RSCT Utilities
rsct.msg.EN_US.core.auditrm:3.2.1.0::COMMITTED:RSCT Audit Log RM Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.errm:3.2.1.0::COMMITTED:RSCT Event Response RM Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.fsrm:3.2.1.0::COMMITTED:RSCT File System RM Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.gui:3.2.1.0::COMMITTED:RSCT GUI Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.hostrm:3.2.1.0::COMMITTED:RSCT Host RM Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.lprm:3.2.1.0::COMMITTED:RSCT LPRM Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.microsensorrm:3.2.1.0::COMMITTED:RSCT MicorSensor RM Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.rmc:3.2.1.0::COMMITTED:RSCT RMC Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.sec:3.2.1.0::COMMITTED:RSCT Security Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.sensorrm:3.2.1.0::COMMITTED:RSCT Sensor RM Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.sr:3.2.1.0::COMMITTED:RSCT Registry Msgs - U.S. English (UTF)
rsct.msg.EN_US.core.utils:3.2.1.0::COMMITTED:RSCT Utilities Msgs - U.S. English (UTF)
rsct.msg.EN_US.opt.storagerm:3.2.1.0::COMMITTED:RSCT Storage RM Msgs - U.S. English (UTF)
rsct.msg.en_US.basic.rte:3.2.1.0::COMMITTED:RSCT Basic Msgs - U.S. English
rsct.msg.en_US.core.auditrm:3.2.1.0::COMMITTED:RSCT Audit Log RM Msgs - U.S. English
rsct.msg.en_US.core.errm:3.2.1.0::COMMITTED:RSCT Event Response RM Msgs - U.S. English
rsct.msg.en_US.core.fsrm:3.2.1.0::COMMITTED:RSCT File System RM Msgs - U.S. English
rsct.msg.en_US.core.gui:3.2.1.0::COMMITTED:RSCT GUI Msgs - U.S. English
rsct.msg.en_US.core.gui.com:3.2.1.0::COMMITTED:RSCT GUI JAVA Msgs - U.S. English
rsct.msg.en_US.core.hostrm:3.2.1.0::COMMITTED:RSCT Host RM Msgs - U.S. English
rsct.msg.en_US.core.lprm:3.2.1.0::COMMITTED:RSCT LPRM Msgs - U.S. English
rsct.msg.en_US.core.microsensorrm:3.2.1.0::COMMITTED:RSCT MicorSensor RM Msgs - U.S. English
rsct.msg.en_US.core.rmc:3.2.1.0::COMMITTED:RSCT RMC Msgs - U.S. English
rsct.msg.en_US.core.rmc.com:3.2.1.0::COMMITTED:RSCT RMC JAVA Msgs - U.S. English
rsct.msg.en_US.core.sec:3.2.1.0::COMMITTED:RSCT Security Msgs - U.S. English
rsct.msg.en_US.core.sensorrm:3.2.1.0::COMMITTED:RSCT Sensor RM Msgs - U.S. English
rsct.msg.en_US.core.sr:3.2.1.0::COMMITTED:RSCT Registry Msgs - U.S. English
rsct.msg.en_US.core.utils:3.2.1.0::COMMITTED:RSCT Utilities Msgs - U.S. English
rsct.msg.en_US.opt.storagerm:3.2.1.0::COMMITTED:RSCT Storage RM Msgs - U.S. English
rsct.opt.stackdump:3.2.1.10::COMMITTED:RSCT Stackdump module
rsct.opt.storagerm:3.2.1.11::COMMITTED:RSCT Storage Resource Manager
security.acf:7.1.4.30::COMMITTED:ACF/PKCS11 Device Driver 
support.tools.zsnap:1.0.0.6::COMMITTED:Ztrans Support Tool
sysmgt.cfgassist:7.1.4.30::COMMITTED:Configuration Assistant 
sysmgtlib.framework.core:7.1.3.0::COMMITTED:System Management Service Libraries Common Code 
sysmgtlib.libraries.apps:7.1.3.0::COMMITTED:System Management Service Libraries Application Code 
tcl.base:8.4.7.0::COMMITTED:Binary executable files of Tcl
tcl.man.en_US:8.4.7.0::COMMITTED:Tcl man page documentation
tivoli.tsm.client.api.64bit:7.1.6.0::COMMITTED:TSM Client - 64bit Application Programming Interface
tivoli.tsm.client.ba.64bit.base:7.1.6.0::COMMITTED:TSM Client 64 - Backup/Archive Base Files
tivoli.tsm.client.ba.64bit.common:7.1.6.0::COMMITTED:TSM Client 64 - Backup/Archive Common Files
tivoli.tsm.client.ba.64bit.hdw:7.1.6.0::COMMITTED:TSM Client 64 - HDW Backup Client
tivoli.tsm.client.ba.64bit.image:7.1.6.0::COMMITTED:TSM Client 64 - IMAGE Backup Client
tivoli.tsm.client.ba.64bit.nas:7.1.6.0::COMMITTED:TSM Client 64 - NAS Backup Client
tivoli.tsm.client.ba.64bit.snphdw:7.1.6.0::COMMITTED:TSM Client 64 - Snap HDW Backup Client
tivoli.tsm.client.ba.64bit.web:7.1.6.0::COMMITTED:TSM Client 64 - Backup/Archive Java GUI & WEB Client
tk.base:8.4.7.0::COMMITTED:Binary executable files of Tk
tk.man.en_US:8.4.7.0::COMMITTED:Tk man page documentation
wio.common:7.1.4.0::COMMITTED:Common I/O Support for Workload Partitions 
wio.fcp:7.1.4.0::COMMITTED:FC I/O Support for Workload Partitions 
wio.vscsi:7.1.1.15::COMMITTED:VSCSI I/O Support for Workload Partitions 
xlC.aix61.rte:13.1.3.1::COMMITTED:IBM XL C++ Runtime for AIX 6.1 and later 
xlC.cpp:9.0.0.0::COMMITTED:C for AIX Preprocessor
xlC.msg.en_US.cpp:9.0.0.0::COMMITTED:C for AIX Preprocessor Messages--U.S. English
xlC.msg.en_US.rte:13.1.3.1::COMMITTED:IBM XL C++ Runtime Messages--U.S. English 
xlC.rte:13.1.3.1::COMMITTED:IBM XL C++ Runtime for AIX 
xlC.sup.aix50.rte:9.0.0.1::COMMITTED:XL C/C++ Runtime for AIX 5.2
xlsmp.aix43.rte:99.99.9999.9999::COMMITTED:Supersede entry, not installed
xlsmp.aix50.rte:99.99.9999.9999::COMMITTED:Supersede entry, not installed
xlsmp.aix52.rte:99.99.9999.9999::COMMITTED:Supersede entry, not installed
xlsmp.aix53.rte:99.99.9999.9999::COMMITTED:Supersede entry, not installed
xlsmp.aix61.rte:4.1.2.0::COMMITTED:SMP Runtime Libraries
xlsmp.msg.en_US.rte:4.1.2.0::COMMITTED:XL SMP Runtime Messages - U.S. English
xlsmp.rte:4.1.2.0::COMMITTED:SMP Runtime Library 

2017-05-26 07:40:28: Check checklslppall.ksh completed successfully: returncode 0
2017-05-26 07:40:28: Runtime: 0 second(s)
2017-05-26 07:40:28: 47% complete - 118 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:28: Running check script 107 of 224: checklsmcode.ksh

Description:
------------

Displays the microcode levels by running the lsmcode command.

Output:
------------

lsmcode -A

sys0!system:SV860_082 (t) SV860_082 (p) SV860_082 (t)
fcs0!df1000e21410f103.00010000020025201919
fcs1!df1000e21410f103.00010000020025201919
sissas0!53495351.16519400
ent0!e4148a1614109304.30100150
ent1!e4148a1614109304.30100150
ent2!e4148a1614109304.30100150
ent3!e4148a1614109304.30100150
ent4!e4148a1614109304.30100150
ent5!e4148a1614109304.30100150
ent6!e4148a1614109304.30100150
ent7!e4148a1614109304.30100150
sissas1!53495351.16519400
fcs2!df1000e21410f103.00010000020025201919
fcs3!df1000e21410f103.00010000020025201919
hdisk0!HUC1018.A1800005.4E393930
cd0!IBM-RMBO014057.IP02
hdisk1!HUC1018.A1800005.4E393930

lsmcode -c

The current permanent system firmware image is FW860.20 (SV860_082)
The current temporary system firmware image is FW860.20 (SV860_082)
The system is currently booted from the temporary firmware image.

2017-05-26 07:40:31: Check checklsmcode.ksh completed successfully: returncode 0
2017-05-26 07:40:31: Runtime: 3 second(s)
2017-05-26 07:40:31: 47% complete - 117 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:31: Running check script 108 of 224: checklsmpio.ksh

Description:
------------

Displays the output of the lsmpio command, if available.

You can use the "-S" option with the lsmpio command, to see more details on any MPIO paths. For 
example:

# lsmpio -l hdisk0 -S

This will show statistics (for example path selections and errors) for a specific path.

Output:
------------

name     path_id  status   path_status  parent    connection

hdisk0   0        Enabled  Sel          sas0      5000cca02f01358c,0
hdisk1   0        Enabled  Sel          sas1      5000cca02f233414,0
hdisk2   0        Enabled  Sel,Opt      pdisk0    5000d31000e8f431,20000000000000
hdisk2   1        Enabled  Sel,Opt      pdisk22   5000d31000e8f433,20000000000000
hdisk2   2        Enabled  Sel,Opt      pdisk90   5000d31000e8f432,20000000000000
hdisk2   3        Enabled  Sel,Opt      pdisk112  5000d31000e8f434,20000000000000
hdisk2   4        Enabled  Sel,Opt      pdisk180  5000d31000e8f431,20000000000000
hdisk2   5        Enabled  Sel,Opt      pdisk202  5000d31000e8f433,20000000000000
hdisk2   6        Enabled  Sel,Opt      pdisk270  5000d31000e8f432,20000000000000
hdisk2   7        Enabled  Sel,Opt      pdisk292  5000d31000e8f434,20000000000000
hdisk3   0        Enabled  Sel,Opt      pdisk1    5000d31000e8f431,10000000000000
hdisk3   1        Enabled  Sel,Opt      pdisk23   5000d31000e8f433,10000000000000
hdisk3   2        Enabled  Sel,Opt      pdisk91   5000d31000e8f432,10000000000000
hdisk3   3        Enabled  Sel,Opt      pdisk113  5000d31000e8f434,10000000000000
hdisk3   4        Enabled  Sel,Opt      pdisk181  5000d31000e8f431,10000000000000
hdisk3   5        Enabled  Sel,Opt      pdisk203  5000d31000e8f433,10000000000000
hdisk3   6        Enabled  Sel,Opt      pdisk271  5000d31000e8f432,10000000000000
hdisk3   7        Enabled  Sel,Opt      pdisk293  5000d31000e8f434,10000000000000
hdisk4   0        Enabled  Sel,Opt      pdisk2    5000d31000e8f431,22000000000000
hdisk4   1        Enabled  Sel,Opt      pdisk24   5000d31000e8f433,22000000000000
hdisk4   2        Enabled  Sel,Opt      pdisk92   5000d31000e8f432,22000000000000
hdisk4   3        Enabled  Sel,Opt      pdisk114  5000d31000e8f434,22000000000000
hdisk4   4        Enabled  Sel,Opt      pdisk182  5000d31000e8f431,22000000000000
hdisk4   5        Enabled  Sel,Opt      pdisk204  5000d31000e8f433,22000000000000
hdisk4   6        Enabled  Sel,Opt      pdisk272  5000d31000e8f432,22000000000000
hdisk4   7        Enabled  Sel,Opt      pdisk294  5000d31000e8f434,22000000000000
hdisk5   0        Enabled  Sel,Opt      pdisk3    5000d31000e8f431,12000000000000
hdisk5   1        Enabled  Sel,Opt      pdisk25   5000d31000e8f433,12000000000000
hdisk5   2        Enabled  Sel,Opt      pdisk93   5000d31000e8f432,12000000000000
hdisk5   3        Enabled  Sel,Opt      pdisk115  5000d31000e8f434,12000000000000
hdisk5   4        Enabled  Sel,Opt      pdisk183  5000d31000e8f431,12000000000000
hdisk5   5        Enabled  Sel,Opt      pdisk205  5000d31000e8f433,12000000000000
hdisk5   6        Enabled  Sel,Opt      pdisk273  5000d31000e8f432,12000000000000
hdisk5   7        Enabled  Sel,Opt      pdisk295  5000d31000e8f434,12000000000000
hdisk6   0        Enabled  Clo          pdisk4    5000d31000e8f431,2000000000000
hdisk6   1        Enabled  Clo          pdisk26   5000d31000e8f433,2000000000000
hdisk6   2        Enabled  Clo          pdisk94   5000d31000e8f432,2000000000000
hdisk6   3        Enabled  Clo          pdisk116  5000d31000e8f434,2000000000000
hdisk6   4        Enabled  Clo          pdisk184  5000d31000e8f431,2000000000000
hdisk6   5        Enabled  Clo          pdisk206  5000d31000e8f433,2000000000000
hdisk6   6        Enabled  Clo          pdisk274  5000d31000e8f432,2000000000000
hdisk6   7        Enabled  Clo          pdisk296  5000d31000e8f434,2000000000000
hdisk7   0        Enabled  Sel,Opt      pdisk5    5000d31000e8f431,24000000000000
hdisk7   1        Enabled  Sel,Opt      pdisk27   5000d31000e8f433,24000000000000
hdisk7   2        Enabled  Sel,Opt      pdisk95   5000d31000e8f432,24000000000000
hdisk7   3        Enabled  Sel,Opt      pdisk117  5000d31000e8f434,24000000000000
hdisk7   4        Enabled  Sel,Opt      pdisk185  5000d31000e8f431,24000000000000
hdisk7   5        Enabled  Sel,Opt      pdisk207  5000d31000e8f433,24000000000000
hdisk7   6        Enabled  Sel,Opt      pdisk275  5000d31000e8f432,24000000000000
hdisk7   7        Enabled  Sel,Opt      pdisk297  5000d31000e8f434,24000000000000
hdisk8   0        Enabled  Sel,Opt      pdisk6    5000d31000e8f431,14000000000000
hdisk8   1        Enabled  Sel,Opt      pdisk28   5000d31000e8f433,14000000000000
hdisk8   2        Enabled  Sel,Opt      pdisk96   5000d31000e8f432,14000000000000
hdisk8   3        Enabled  Sel,Opt      pdisk118  5000d31000e8f434,14000000000000
hdisk8   4        Enabled  Sel,Opt      pdisk186  5000d31000e8f431,14000000000000
hdisk8   5        Enabled  Sel,Opt      pdisk208  5000d31000e8f433,14000000000000
hdisk8   6        Enabled  Sel,Opt      pdisk276  5000d31000e8f432,14000000000000
hdisk8   7        Enabled  Sel,Opt      pdisk298  5000d31000e8f434,14000000000000
hdisk9   0        Enabled  Sel,Opt      pdisk7    5000d31000e8f431,4000000000000
hdisk9   1        Enabled  Sel,Opt      pdisk29   5000d31000e8f433,4000000000000
hdisk9   2        Enabled  Sel,Opt      pdisk97   5000d31000e8f432,4000000000000
hdisk9   3        Enabled  Sel,Opt      pdisk119  5000d31000e8f434,4000000000000
hdisk9   4        Enabled  Sel,Opt      pdisk187  5000d31000e8f431,4000000000000
hdisk9   5        Enabled  Sel,Opt      pdisk209  5000d31000e8f433,4000000000000
hdisk9   6        Enabled  Sel,Opt      pdisk277  5000d31000e8f432,4000000000000
hdisk9   7        Enabled  Sel,Opt      pdisk299  5000d31000e8f434,4000000000000
hdisk10  0        Enabled  Sel,Opt      pdisk8    5000d31000e8f431,26000000000000
hdisk10  1        Enabled  Sel,Opt      pdisk30   5000d31000e8f433,26000000000000
hdisk10  2        Enabled  Sel,Opt      pdisk98   5000d31000e8f432,26000000000000
hdisk10  3        Enabled  Sel,Opt      pdisk120  5000d31000e8f434,26000000000000
hdisk10  4        Enabled  Sel,Opt      pdisk188  5000d31000e8f431,26000000000000
hdisk10  5        Enabled  Sel,Opt      pdisk210  5000d31000e8f433,26000000000000
hdisk10  6        Enabled  Sel,Opt      pdisk278  5000d31000e8f432,26000000000000
hdisk10  7        Enabled  Sel,Opt      pdisk300  5000d31000e8f434,26000000000000
hdisk11  0        Enabled  Sel,Opt      pdisk9    5000d31000e8f431,16000000000000
hdisk11  1        Enabled  Sel,Opt      pdisk31   5000d31000e8f433,16000000000000
hdisk11  2        Enabled  Sel,Opt      pdisk99   5000d31000e8f432,16000000000000
hdisk11  3        Enabled  Sel,Opt      pdisk121  5000d31000e8f434,16000000000000
hdisk11  4        Enabled  Sel,Opt      pdisk189  5000d31000e8f431,16000000000000
hdisk11  5        Enabled  Sel,Opt      pdisk211  5000d31000e8f433,16000000000000
hdisk11  6        Enabled  Sel,Opt      pdisk279  5000d31000e8f432,16000000000000
hdisk11  7        Enabled  Sel,Opt      pdisk301  5000d31000e8f434,16000000000000
hdisk12  0        Enabled  Sel,Opt      pdisk10   5000d31000e8f431,6000000000000
hdisk12  1        Enabled  Sel,Opt      pdisk32   5000d31000e8f433,6000000000000
hdisk12  2        Enabled  Sel,Opt      pdisk100  5000d31000e8f432,6000000000000
hdisk12  3        Enabled  Sel,Opt      pdisk122  5000d31000e8f434,6000000000000
hdisk12  4        Enabled  Sel,Opt      pdisk190  5000d31000e8f431,6000000000000
hdisk12  5        Enabled  Sel,Opt      pdisk212  5000d31000e8f433,6000000000000
hdisk12  6        Enabled  Sel,Opt      pdisk280  5000d31000e8f432,6000000000000
hdisk12  7        Enabled  Sel,Opt      pdisk302  5000d31000e8f434,6000000000000
hdisk13  0        Enabled  Sel,Opt      pdisk11   5000d31000e8f431,28000000000000
hdisk13  1        Enabled  Sel,Opt      pdisk33   5000d31000e8f433,28000000000000
hdisk13  2        Enabled  Sel,Opt      pdisk101  5000d31000e8f432,28000000000000
hdisk13  3        Enabled  Sel,Opt      pdisk123  5000d31000e8f434,28000000000000
hdisk13  4        Enabled  Sel,Opt      pdisk191  5000d31000e8f431,28000000000000
hdisk13  5        Enabled  Sel,Opt      pdisk213  5000d31000e8f433,28000000000000
hdisk13  6        Enabled  Sel,Opt      pdisk281  5000d31000e8f432,28000000000000
hdisk13  7        Enabled  Sel,Opt      pdisk303  5000d31000e8f434,28000000000000
hdisk14  0        Enabled  Sel,Opt      pdisk12   5000d31000e8f431,18000000000000
hdisk14  1        Enabled  Sel,Opt      pdisk34   5000d31000e8f433,18000000000000
hdisk14  2        Enabled  Sel,Opt      pdisk102  5000d31000e8f432,18000000000000
hdisk14  3        Enabled  Sel,Opt      pdisk124  5000d31000e8f434,18000000000000
hdisk14  4        Enabled  Sel,Opt      pdisk192  5000d31000e8f431,18000000000000
hdisk14  5        Enabled  Sel,Opt      pdisk214  5000d31000e8f433,18000000000000
hdisk14  6        Enabled  Sel,Opt      pdisk282  5000d31000e8f432,18000000000000
hdisk14  7        Enabled  Sel,Opt      pdisk304  5000d31000e8f434,18000000000000
hdisk15  0        Enabled  Sel,Opt      pdisk13   5000d31000e8f431,8000000000000
hdisk15  1        Enabled  Sel,Opt      pdisk35   5000d31000e8f433,8000000000000
hdisk15  2        Enabled  Sel,Opt      pdisk103  5000d31000e8f432,8000000000000
hdisk15  3        Enabled  Sel,Opt      pdisk125  5000d31000e8f434,8000000000000
hdisk15  4        Enabled  Sel,Opt      pdisk193  5000d31000e8f431,8000000000000
hdisk15  5        Enabled  Sel,Opt      pdisk215  5000d31000e8f433,8000000000000
hdisk15  6        Enabled  Sel,Opt      pdisk283  5000d31000e8f432,8000000000000
hdisk15  7        Enabled  Sel,Opt      pdisk305  5000d31000e8f434,8000000000000
hdisk16  0        Enabled  Sel,Opt      pdisk14   5000d31000e8f431,2a000000000000
hdisk16  1        Enabled  Sel,Opt      pdisk36   5000d31000e8f433,2a000000000000
hdisk16  2        Enabled  Sel,Opt      pdisk104  5000d31000e8f432,2a000000000000
hdisk16  3        Enabled  Sel,Opt      pdisk126  5000d31000e8f434,2a000000000000
hdisk16  4        Enabled  Sel,Opt      pdisk194  5000d31000e8f431,2a000000000000
hdisk16  5        Enabled  Sel,Opt      pdisk216  5000d31000e8f433,2a000000000000
hdisk16  6        Enabled  Sel,Opt      pdisk284  5000d31000e8f432,2a000000000000
hdisk16  7        Enabled  Sel,Opt      pdisk306  5000d31000e8f434,2a000000000000
hdisk17  0        Enabled  Sel,Opt      pdisk15   5000d31000e8f431,1a000000000000
hdisk17  1        Enabled  Sel,Opt      pdisk37   5000d31000e8f433,1a000000000000
hdisk17  2        Enabled  Sel,Opt      pdisk105  5000d31000e8f432,1a000000000000
hdisk17  3        Enabled  Sel,Opt      pdisk127  5000d31000e8f434,1a000000000000
hdisk17  4        Enabled  Sel,Opt      pdisk195  5000d31000e8f431,1a000000000000
hdisk17  5        Enabled  Sel,Opt      pdisk217  5000d31000e8f433,1a000000000000
hdisk17  6        Enabled  Sel,Opt      pdisk285  5000d31000e8f432,1a000000000000
hdisk17  7        Enabled  Sel,Opt      pdisk307  5000d31000e8f434,1a000000000000
hdisk18  0        Enabled  Sel,Opt      pdisk16   5000d31000e8f431,a000000000000
hdisk18  1        Enabled  Sel,Opt      pdisk38   5000d31000e8f433,a000000000000
hdisk18  2        Enabled  Sel,Opt      pdisk106  5000d31000e8f432,a000000000000
hdisk18  3        Enabled  Sel,Opt      pdisk128  5000d31000e8f434,a000000000000
hdisk18  4        Enabled  Sel,Opt      pdisk196  5000d31000e8f431,a000000000000
hdisk18  5        Enabled  Sel,Opt      pdisk218  5000d31000e8f433,a000000000000
hdisk18  6        Enabled  Sel,Opt      pdisk286  5000d31000e8f432,a000000000000
hdisk18  7        Enabled  Sel,Opt      pdisk308  5000d31000e8f434,a000000000000
hdisk19  0        Enabled  Sel,Opt      pdisk17   5000d31000e8f431,2c000000000000
hdisk19  1        Enabled  Sel,Opt      pdisk39   5000d31000e8f433,2c000000000000
hdisk19  2        Enabled  Sel,Opt      pdisk107  5000d31000e8f432,2c000000000000
hdisk19  3        Enabled  Sel,Opt      pdisk129  5000d31000e8f434,2c000000000000
hdisk19  4        Enabled  Sel,Opt      pdisk197  5000d31000e8f431,2c000000000000
hdisk19  5        Enabled  Sel,Opt      pdisk219  5000d31000e8f433,2c000000000000
hdisk19  6        Enabled  Sel,Opt      pdisk287  5000d31000e8f432,2c000000000000
hdisk19  7        Enabled  Sel,Opt      pdisk309  5000d31000e8f434,2c000000000000
hdisk20  0        Enabled  Sel,Opt      pdisk18   5000d31000e8f431,1c000000000000
hdisk20  1        Enabled  Sel,Opt      pdisk40   5000d31000e8f433,1c000000000000
hdisk20  2        Enabled  Sel,Opt      pdisk108  5000d31000e8f432,1c000000000000
hdisk20  3        Enabled  Sel,Opt      pdisk130  5000d31000e8f434,1c000000000000
hdisk20  4        Enabled  Sel,Opt      pdisk198  5000d31000e8f431,1c000000000000
hdisk20  5        Enabled  Sel,Opt      pdisk220  5000d31000e8f433,1c000000000000
hdisk20  6        Enabled  Sel,Opt      pdisk288  5000d31000e8f432,1c000000000000
hdisk20  7        Enabled  Sel,Opt      pdisk310  5000d31000e8f434,1c000000000000
hdisk21  0        Enabled  Sel,Opt      pdisk19   5000d31000e8f431,c000000000000
hdisk21  1        Enabled  Sel,Opt      pdisk41   5000d31000e8f433,c000000000000
hdisk21  2        Enabled  Sel,Opt      pdisk109  5000d31000e8f432,c000000000000
hdisk21  3        Enabled  Sel,Opt      pdisk131  5000d31000e8f434,c000000000000
hdisk21  4        Enabled  Sel,Opt      pdisk199  5000d31000e8f431,c000000000000
hdisk21  5        Enabled  Sel,Opt      pdisk221  5000d31000e8f433,c000000000000
hdisk21  6        Enabled  Sel,Opt      pdisk289  5000d31000e8f432,c000000000000
hdisk21  7        Enabled  Sel,Opt      pdisk311  5000d31000e8f434,c000000000000
hdisk22  0        Enabled  Sel,Opt      pdisk20   5000d31000e8f431,1e000000000000
hdisk22  1        Enabled  Sel,Opt      pdisk42   5000d31000e8f433,1e000000000000
hdisk22  2        Enabled  Sel,Opt      pdisk110  5000d31000e8f432,1e000000000000
hdisk22  3        Enabled  Sel,Opt      pdisk132  5000d31000e8f434,1e000000000000
hdisk22  4        Enabled  Sel,Opt      pdisk200  5000d31000e8f431,1e000000000000
hdisk22  5        Enabled  Sel,Opt      pdisk222  5000d31000e8f433,1e000000000000
hdisk22  6        Enabled  Sel,Opt      pdisk290  5000d31000e8f432,1e000000000000
hdisk22  7        Enabled  Sel,Opt      pdisk312  5000d31000e8f434,1e000000000000
hdisk23  0        Enabled  Sel,Opt      pdisk21   5000d31000e8f431,e000000000000
hdisk23  1        Enabled  Sel,Opt      pdisk43   5000d31000e8f433,e000000000000
hdisk23  2        Enabled  Sel,Opt      pdisk111  5000d31000e8f432,e000000000000
hdisk23  3        Enabled  Sel,Opt      pdisk133  5000d31000e8f434,e000000000000
hdisk23  4        Enabled  Sel,Opt      pdisk201  5000d31000e8f431,e000000000000
hdisk23  5        Enabled  Sel,Opt      pdisk223  5000d31000e8f433,e000000000000
hdisk23  6        Enabled  Sel,Opt      pdisk291  5000d31000e8f432,e000000000000
hdisk23  7        Enabled  Sel,Opt      pdisk313  5000d31000e8f434,e000000000000
hdisk24  0        Enabled  Sel,Opt      pdisk44   5000d31000e8f42d,21000000000000
hdisk24  1        Enabled  Sel,Opt      pdisk67   5000d31000e8f42f,21000000000000
hdisk24  2        Enabled  Sel,Opt      pdisk134  5000d31000e8f42e,21000000000000
hdisk24  3        Enabled  Sel,Opt      pdisk157  5000d31000e8f430,21000000000000
hdisk24  4        Enabled  Sel,Opt      pdisk224  5000d31000e8f42d,21000000000000
hdisk24  5        Enabled  Sel,Opt      pdisk247  5000d31000e8f42f,21000000000000
hdisk24  6        Enabled  Sel,Opt      pdisk314  5000d31000e8f42e,21000000000000
hdisk24  7        Enabled  Sel,Opt      pdisk337  5000d31000e8f430,21000000000000
hdisk25  0        Enabled  Sel,Opt      pdisk45   5000d31000e8f42d,11000000000000
hdisk25  1        Enabled  Sel,Opt      pdisk68   5000d31000e8f42f,11000000000000
hdisk25  2        Enabled  Sel,Opt      pdisk135  5000d31000e8f42e,11000000000000
hdisk25  3        Enabled  Sel,Opt      pdisk158  5000d31000e8f430,11000000000000
hdisk25  4        Enabled  Sel,Opt      pdisk225  5000d31000e8f42d,11000000000000
hdisk25  5        Enabled  Sel,Opt      pdisk248  5000d31000e8f42f,11000000000000
hdisk25  6        Enabled  Sel,Opt      pdisk315  5000d31000e8f42e,11000000000000
hdisk25  7        Enabled  Sel,Opt      pdisk338  5000d31000e8f430,11000000000000
hdisk26  0        Enabled  Sel,Opt      pdisk46   5000d31000e8f42d,1000000000000
hdisk26  1        Enabled  Sel,Opt      pdisk69   5000d31000e8f42f,1000000000000
hdisk26  2        Enabled  Sel,Opt      pdisk136  5000d31000e8f42e,1000000000000
hdisk26  3        Enabled  Sel,Opt      pdisk159  5000d31000e8f430,1000000000000
hdisk26  4        Enabled  Sel,Opt      pdisk226  5000d31000e8f42d,1000000000000
hdisk26  5        Enabled  Sel,Opt      pdisk249  5000d31000e8f42f,1000000000000
hdisk26  6        Enabled  Sel,Opt      pdisk316  5000d31000e8f42e,1000000000000
hdisk26  7        Enabled  Sel,Opt      pdisk339  5000d31000e8f430,1000000000000
hdisk27  0        Enabled  Sel,Opt      pdisk47   5000d31000e8f42d,23000000000000
hdisk27  1        Enabled  Sel,Opt      pdisk70   5000d31000e8f42f,23000000000000
hdisk27  2        Enabled  Sel,Opt      pdisk137  5000d31000e8f42e,23000000000000
hdisk27  3        Enabled  Sel,Opt      pdisk160  5000d31000e8f430,23000000000000
hdisk27  4        Enabled  Sel,Opt      pdisk227  5000d31000e8f42d,23000000000000
hdisk27  5        Enabled  Sel,Opt      pdisk250  5000d31000e8f42f,23000000000000
hdisk27  6        Enabled  Sel,Opt      pdisk317  5000d31000e8f42e,23000000000000
hdisk27  7        Enabled  Sel,Opt      pdisk340  5000d31000e8f430,23000000000000
hdisk28  0        Enabled  Sel,Opt      pdisk48   5000d31000e8f42d,13000000000000
hdisk28  1        Enabled  Sel,Opt      pdisk71   5000d31000e8f42f,13000000000000
hdisk28  2        Enabled  Sel,Opt      pdisk138  5000d31000e8f42e,13000000000000
hdisk28  3        Enabled  Sel,Opt      pdisk161  5000d31000e8f430,13000000000000
hdisk28  4        Enabled  Sel,Opt      pdisk228  5000d31000e8f42d,13000000000000
hdisk28  5        Enabled  Sel,Opt      pdisk251  5000d31000e8f42f,13000000000000
hdisk28  6        Enabled  Sel,Opt      pdisk318  5000d31000e8f42e,13000000000000
hdisk28  7        Enabled  Sel,Opt      pdisk341  5000d31000e8f430,13000000000000
hdisk29  0        Enabled  Sel,Opt      pdisk49   5000d31000e8f42d,3000000000000
hdisk29  1        Enabled  Sel,Opt      pdisk72   5000d31000e8f42f,3000000000000
hdisk29  2        Enabled  Sel,Opt      pdisk139  5000d31000e8f42e,3000000000000
hdisk29  3        Enabled  Sel,Opt      pdisk162  5000d31000e8f430,3000000000000
hdisk29  4        Enabled  Sel,Opt      pdisk229  5000d31000e8f42d,3000000000000
hdisk29  5        Enabled  Sel,Opt      pdisk252  5000d31000e8f42f,3000000000000
hdisk29  6        Enabled  Sel,Opt      pdisk319  5000d31000e8f42e,3000000000000
hdisk29  7        Enabled  Sel,Opt      pdisk342  5000d31000e8f430,3000000000000
hdisk30  0        Enabled  Sel,Opt      pdisk50   5000d31000e8f42d,25000000000000
hdisk30  1        Enabled  Sel,Opt      pdisk73   5000d31000e8f42f,25000000000000
hdisk30  2        Enabled  Sel,Opt      pdisk140  5000d31000e8f42e,25000000000000
hdisk30  3        Enabled  Sel,Opt      pdisk163  5000d31000e8f430,25000000000000
hdisk30  4        Enabled  Sel,Opt      pdisk230  5000d31000e8f42d,25000000000000
hdisk30  5        Enabled  Sel,Opt      pdisk253  5000d31000e8f42f,25000000000000
hdisk30  6        Enabled  Sel,Opt      pdisk320  5000d31000e8f42e,25000000000000
hdisk30  7        Enabled  Sel,Opt      pdisk343  5000d31000e8f430,25000000000000
hdisk31  0        Enabled  Sel,Opt      pdisk51   5000d31000e8f42d,15000000000000
hdisk31  1        Enabled  Sel,Opt      pdisk74   5000d31000e8f42f,15000000000000
hdisk31  2        Enabled  Sel,Opt      pdisk141  5000d31000e8f42e,15000000000000
hdisk31  3        Enabled  Sel,Opt      pdisk164  5000d31000e8f430,15000000000000
hdisk31  4        Enabled  Sel,Opt      pdisk231  5000d31000e8f42d,15000000000000
hdisk31  5        Enabled  Sel,Opt      pdisk254  5000d31000e8f42f,15000000000000
hdisk31  6        Enabled  Sel,Opt      pdisk321  5000d31000e8f42e,15000000000000
hdisk31  7        Enabled  Sel,Opt      pdisk344  5000d31000e8f430,15000000000000
hdisk32  0        Enabled  Sel,Opt      pdisk52   5000d31000e8f42d,5000000000000
hdisk32  1        Enabled  Sel,Opt      pdisk75   5000d31000e8f42f,5000000000000
hdisk32  2        Enabled  Sel,Opt      pdisk142  5000d31000e8f42e,5000000000000
hdisk32  3        Enabled  Sel,Opt      pdisk165  5000d31000e8f430,5000000000000
hdisk32  4        Enabled  Sel,Opt      pdisk232  5000d31000e8f42d,5000000000000
hdisk32  5        Enabled  Sel,Opt      pdisk255  5000d31000e8f42f,5000000000000
hdisk32  6        Enabled  Sel,Opt      pdisk322  5000d31000e8f42e,5000000000000
hdisk32  7        Enabled  Sel,Opt      pdisk345  5000d31000e8f430,5000000000000
hdisk33  0        Enabled  Sel,Opt      pdisk53   5000d31000e8f42d,27000000000000
hdisk33  1        Enabled  Sel,Opt      pdisk76   5000d31000e8f42f,27000000000000
hdisk33  2        Enabled  Sel,Opt      pdisk143  5000d31000e8f42e,27000000000000
hdisk33  3        Enabled  Sel,Opt      pdisk166  5000d31000e8f430,27000000000000
hdisk33  4        Enabled  Sel,Opt      pdisk233  5000d31000e8f42d,27000000000000
hdisk33  5        Enabled  Sel,Opt      pdisk256  5000d31000e8f42f,27000000000000
hdisk33  6        Enabled  Sel,Opt      pdisk323  5000d31000e8f42e,27000000000000
hdisk33  7        Enabled  Sel,Opt      pdisk346  5000d31000e8f430,27000000000000
hdisk34  0        Enabled  Sel,Opt      pdisk54   5000d31000e8f42d,17000000000000
hdisk34  1        Enabled  Sel,Opt      pdisk77   5000d31000e8f42f,17000000000000
hdisk34  2        Enabled  Sel,Opt      pdisk144  5000d31000e8f42e,17000000000000
hdisk34  3        Enabled  Sel,Opt      pdisk167  5000d31000e8f430,17000000000000
hdisk34  4        Enabled  Sel,Opt      pdisk234  5000d31000e8f42d,17000000000000
hdisk34  5        Enabled  Sel,Opt      pdisk257  5000d31000e8f42f,17000000000000
hdisk34  6        Enabled  Sel,Opt      pdisk324  5000d31000e8f42e,17000000000000
hdisk34  7        Enabled  Sel,Opt      pdisk347  5000d31000e8f430,17000000000000
hdisk35  0        Enabled  Sel,Opt      pdisk55   5000d31000e8f42d,7000000000000
hdisk35  1        Enabled  Sel,Opt      pdisk78   5000d31000e8f42f,7000000000000
hdisk35  2        Enabled  Sel,Opt      pdisk145  5000d31000e8f42e,7000000000000
hdisk35  3        Enabled  Sel,Opt      pdisk168  5000d31000e8f430,7000000000000
hdisk35  4        Enabled  Sel,Opt      pdisk235  5000d31000e8f42d,7000000000000
hdisk35  5        Enabled  Sel,Opt      pdisk258  5000d31000e8f42f,7000000000000
hdisk35  6        Enabled  Sel,Opt      pdisk325  5000d31000e8f42e,7000000000000
hdisk35  7        Enabled  Sel,Opt      pdisk348  5000d31000e8f430,7000000000000
hdisk36  0        Enabled  Sel,Opt      pdisk56   5000d31000e8f42d,29000000000000
hdisk36  1        Enabled  Sel,Opt      pdisk79   5000d31000e8f42f,29000000000000
hdisk36  2        Enabled  Sel,Opt      pdisk146  5000d31000e8f42e,29000000000000
hdisk36  3        Enabled  Sel,Opt      pdisk169  5000d31000e8f430,29000000000000
hdisk36  4        Enabled  Sel,Opt      pdisk236  5000d31000e8f42d,29000000000000
hdisk36  5        Enabled  Sel,Opt      pdisk259  5000d31000e8f42f,29000000000000
hdisk36  6        Enabled  Sel,Opt      pdisk326  5000d31000e8f42e,29000000000000
hdisk36  7        Enabled  Sel,Opt      pdisk349  5000d31000e8f430,29000000000000
hdisk37  0        Enabled  Sel,Opt      pdisk57   5000d31000e8f42d,19000000000000
hdisk37  1        Enabled  Sel,Opt      pdisk80   5000d31000e8f42f,19000000000000
hdisk37  2        Enabled  Sel,Opt      pdisk147  5000d31000e8f42e,19000000000000
hdisk37  3        Enabled  Sel,Opt      pdisk170  5000d31000e8f430,19000000000000
hdisk37  4        Enabled  Sel,Opt      pdisk237  5000d31000e8f42d,19000000000000
hdisk37  5        Enabled  Sel,Opt      pdisk260  5000d31000e8f42f,19000000000000
hdisk37  6        Enabled  Sel,Opt      pdisk327  5000d31000e8f42e,19000000000000
hdisk37  7        Enabled  Sel,Opt      pdisk350  5000d31000e8f430,19000000000000
hdisk38  0        Enabled  Sel,Opt      pdisk58   5000d31000e8f42d,9000000000000
hdisk38  1        Enabled  Sel,Opt      pdisk81   5000d31000e8f42f,9000000000000
hdisk38  2        Enabled  Sel,Opt      pdisk148  5000d31000e8f42e,9000000000000
hdisk38  3        Enabled  Sel,Opt      pdisk171  5000d31000e8f430,9000000000000
hdisk38  4        Enabled  Sel,Opt      pdisk238  5000d31000e8f42d,9000000000000
hdisk38  5        Enabled  Sel,Opt      pdisk261  5000d31000e8f42f,9000000000000
hdisk38  6        Enabled  Sel,Opt      pdisk328  5000d31000e8f42e,9000000000000
hdisk38  7        Enabled  Sel,Opt      pdisk351  5000d31000e8f430,9000000000000
hdisk39  0        Enabled  Sel,Opt      pdisk59   5000d31000e8f42d,2b000000000000
hdisk39  1        Enabled  Sel,Opt      pdisk82   5000d31000e8f42f,2b000000000000
hdisk39  2        Enabled  Sel,Opt      pdisk149  5000d31000e8f42e,2b000000000000
hdisk39  3        Enabled  Sel,Opt      pdisk172  5000d31000e8f430,2b000000000000
hdisk39  4        Enabled  Sel,Opt      pdisk239  5000d31000e8f42d,2b000000000000
hdisk39  5        Enabled  Sel,Opt      pdisk262  5000d31000e8f42f,2b000000000000
hdisk39  6        Enabled  Sel,Opt      pdisk329  5000d31000e8f42e,2b000000000000
hdisk39  7        Enabled  Sel,Opt      pdisk352  5000d31000e8f430,2b000000000000
hdisk40  0        Enabled  Sel,Opt      pdisk60   5000d31000e8f42d,1b000000000000
hdisk40  1        Enabled  Sel,Opt      pdisk83   5000d31000e8f42f,1b000000000000
hdisk40  2        Enabled  Sel,Opt      pdisk150  5000d31000e8f42e,1b000000000000
hdisk40  3        Enabled  Sel,Opt      pdisk173  5000d31000e8f430,1b000000000000
hdisk40  4        Enabled  Sel,Opt      pdisk240  5000d31000e8f42d,1b000000000000
hdisk40  5        Enabled  Sel,Opt      pdisk263  5000d31000e8f42f,1b000000000000
hdisk40  6        Enabled  Sel,Opt      pdisk330  5000d31000e8f42e,1b000000000000
hdisk40  7        Enabled  Sel,Opt      pdisk353  5000d31000e8f430,1b000000000000
hdisk41  0        Enabled  Sel,Opt      pdisk61   5000d31000e8f42d,b000000000000
hdisk41  1        Enabled  Sel,Opt      pdisk84   5000d31000e8f42f,b000000000000
hdisk41  2        Enabled  Sel,Opt      pdisk151  5000d31000e8f42e,b000000000000
hdisk41  3        Enabled  Sel,Opt      pdisk174  5000d31000e8f430,b000000000000
hdisk41  4        Enabled  Sel,Opt      pdisk241  5000d31000e8f42d,b000000000000
hdisk41  5        Enabled  Sel,Opt      pdisk264  5000d31000e8f42f,b000000000000
hdisk41  6        Enabled  Sel,Opt      pdisk331  5000d31000e8f42e,b000000000000
hdisk41  7        Enabled  Sel,Opt      pdisk354  5000d31000e8f430,b000000000000
hdisk42  0        Enabled  Sel,Opt      pdisk62   5000d31000e8f42d,2d000000000000
hdisk42  1        Enabled  Sel,Opt      pdisk85   5000d31000e8f42f,2d000000000000
hdisk42  2        Enabled  Sel,Opt      pdisk152  5000d31000e8f42e,2d000000000000
hdisk42  3        Enabled  Sel,Opt      pdisk175  5000d31000e8f430,2d000000000000
hdisk42  4        Enabled  Sel,Opt      pdisk242  5000d31000e8f42d,2d000000000000
hdisk42  5        Enabled  Sel,Opt      pdisk265  5000d31000e8f42f,2d000000000000
hdisk42  6        Enabled  Sel,Opt      pdisk332  5000d31000e8f42e,2d000000000000
hdisk42  7        Enabled  Sel,Opt      pdisk355  5000d31000e8f430,2d000000000000
hdisk43  0        Enabled  Sel,Opt      pdisk63   5000d31000e8f42d,1d000000000000
hdisk43  1        Enabled  Sel,Opt      pdisk86   5000d31000e8f42f,1d000000000000
hdisk43  2        Enabled  Sel,Opt      pdisk153  5000d31000e8f42e,1d000000000000
hdisk43  3        Enabled  Sel,Opt      pdisk176  5000d31000e8f430,1d000000000000
hdisk43  4        Enabled  Sel,Opt      pdisk243  5000d31000e8f42d,1d000000000000
hdisk43  5        Enabled  Sel,Opt      pdisk266  5000d31000e8f42f,1d000000000000
hdisk43  6        Enabled  Sel,Opt      pdisk333  5000d31000e8f42e,1d000000000000
hdisk43  7        Enabled  Sel,Opt      pdisk356  5000d31000e8f430,1d000000000000
hdisk44  0        Enabled  Sel,Opt      pdisk64   5000d31000e8f42d,d000000000000
hdisk44  1        Enabled  Sel,Opt      pdisk87   5000d31000e8f42f,d000000000000
hdisk44  2        Enabled  Sel,Opt      pdisk154  5000d31000e8f42e,d000000000000
hdisk44  3        Enabled  Sel,Opt      pdisk177  5000d31000e8f430,d000000000000
hdisk44  4        Enabled  Sel,Opt      pdisk244  5000d31000e8f42d,d000000000000
hdisk44  5        Enabled  Sel,Opt      pdisk267  5000d31000e8f42f,d000000000000
hdisk44  6        Enabled  Sel,Opt      pdisk334  5000d31000e8f42e,d000000000000
hdisk44  7        Enabled  Sel,Opt      pdisk357  5000d31000e8f430,d000000000000
hdisk45  0        Enabled  Sel,Opt      pdisk65   5000d31000e8f42d,1f000000000000
hdisk45  1        Enabled  Sel,Opt      pdisk88   5000d31000e8f42f,1f000000000000
hdisk45  2        Enabled  Sel,Opt      pdisk155  5000d31000e8f42e,1f000000000000
hdisk45  3        Enabled  Sel,Opt      pdisk178  5000d31000e8f430,1f000000000000
hdisk45  4        Enabled  Sel,Opt      pdisk245  5000d31000e8f42d,1f000000000000
hdisk45  5        Enabled  Sel,Opt      pdisk268  5000d31000e8f42f,1f000000000000
hdisk45  6        Enabled  Sel,Opt      pdisk335  5000d31000e8f42e,1f000000000000
hdisk45  7        Enabled  Sel,Opt      pdisk358  5000d31000e8f430,1f000000000000
hdisk46  0        Enabled  Sel,Opt      pdisk66   5000d31000e8f42d,f000000000000
hdisk46  1        Enabled  Sel,Opt      pdisk89   5000d31000e8f42f,f000000000000
hdisk46  2        Enabled  Sel,Opt      pdisk156  5000d31000e8f42e,f000000000000
hdisk46  3        Enabled  Sel,Opt      pdisk179  5000d31000e8f430,f000000000000
hdisk46  4        Enabled  Sel,Opt      pdisk246  5000d31000e8f42d,f000000000000
hdisk46  5        Enabled  Sel,Opt      pdisk269  5000d31000e8f42f,f000000000000
hdisk46  6        Enabled  Sel,Opt      pdisk336  5000d31000e8f42e,f000000000000
hdisk46  7        Enabled  Sel,Opt      pdisk359  5000d31000e8f430,f000000000000
hdisk47  0        Enabled  Sel,Opt      pdisk360  5000d31000e8f42d,2e000000000000
hdisk47  1        Enabled  Sel,Opt      pdisk361  5000d31000e8f42f,2e000000000000
hdisk47  2        Enabled  Sel,Opt      pdisk362  5000d31000e8f42e,2e000000000000
hdisk47  3        Enabled  Sel,Opt      pdisk363  5000d31000e8f430,2e000000000000
hdisk47  4        Enabled  Sel,Opt      pdisk364  5000d31000e8f42d,2e000000000000
hdisk47  5        Enabled  Sel,Opt      pdisk365  5000d31000e8f42f,2e000000000000
hdisk47  6        Enabled  Sel,Opt      pdisk366  5000d31000e8f42e,2e000000000000
hdisk47  7        Enabled  Sel,Opt      pdisk367  5000d31000e8f430,2e000000000000

2017-05-26 07:40:31: Check checklsmpio.ksh completed successfully: returncode 0
2017-05-26 07:40:31: Runtime: 0 second(s)
2017-05-26 07:40:31: 48% complete - 116 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:31: Running check script 109 of 224: checklspv.ksh

Description:
------------

Lists all the physical volumes on the system by running the lspv command.

Output:
------------

hdisk0          00fab085b321dc73                    rootvg          active      
hdisk1          00fab085bd0bee89                    rootvg          active      
hdisk2          00fab085c266b60c                    tsmfs01vg       concurrent  
hdisk3          00fab085c266b01c                    tsmdbvg         concurrent  
hdisk4          00fab085c266a9d6                    tsmfs01vg       concurrent  
hdisk5          00fab085c266a59b                    tsmdbvg         concurrent  
hdisk7          00fab085c266a46c                    tsmfs01vg       concurrent  
hdisk8          00fab085c266a3de                    tsmdbbkpvg      concurrent  
hdisk9          00fab085c266a317                    tsmrecoveryvg   concurrent  
hdisk10         00fab085c266bb45                    tsmfs01vg       concurrent  
hdisk11         00fab085c266babc                    tsmdbbkpvg      concurrent  
hdisk12         00fab085c266ba3a                    tsmarchlogvg    concurrent  
hdisk13         00fab085c266b9b1                    tsmfs01vg       concurrent  
hdisk14         00fab085c266b930                    tsmfs01vg       concurrent  
hdisk15         00fab085c266b8a6                    tsmdbvg         concurrent  
hdisk16         00fab085c266b82b                    tsmfs01vg       concurrent  
hdisk17         00fab085c266b79d                    tsmfs01vg       concurrent  
hdisk18         00fab085c266b719                    tsmdbvg         concurrent  
hdisk19         00fab085c266b68d                    tsmfs01vg       concurrent  
hdisk20         00fab085c266b58a                    tsmfs01vg       concurrent  
hdisk21         00fab085c266b50d                    tsmdbvg         concurrent  
hdisk22         00fab085c266b480                    tsmfs01vg       concurrent  
hdisk23         00fab085c266b400                    tsmdbvg         concurrent  
hdisk24         00fab085c266b36b                    tsmfs02vg       concurrent  
hdisk25         00fab085c266b2ed                    tsmdbvg         concurrent  
hdisk26         00fab085c266b25a                    caavg_private   active      
hdisk27         00fab085c266b1cc                    tsmfs02vg       concurrent  
hdisk28         00fab085c266b135                    tsmdbbkpvg      concurrent  
hdisk29         00fab085c266b0a2                    tsmactlogvg     concurrent  
hdisk30         00fab085c266af8a                    tsmfs02vg       concurrent  
hdisk31         00fab085c266aefe                    tsmdbbkpvg      concurrent  
hdisk32         00fab085c266ae78                    tsmarchlogvg    concurrent  
hdisk33         00fab085c266adc9                    tsmfs02vg       concurrent  
hdisk34         00fab085c266ace7                    tsmfs02vg       concurrent  
hdisk35         00fab085c266ac66                    tsmdbvg         concurrent  
hdisk36         00fab085c266abe4                    tsmfs02vg       concurrent  
hdisk37         00fab085c266ab5a                    tsmfs02vg       concurrent  
hdisk38         00fab085c266aad7                    tsmdbvg         concurrent  
hdisk39         00fab085c266aa56                    tsmfs02vg       concurrent  
hdisk40         00fab085c266a94f                    tsmfs02vg       concurrent  
hdisk41         00fab085c266a8ca                    tsmdbvg         concurrent  
hdisk42         00fab085c266a838                    tsmrecoveryvg   concurrent  
hdisk43         00fab085c266a7a1                    tsmfs02vg       concurrent  
hdisk44         00fab085c266a724                    tsmdbvg         concurrent  
hdisk45         00fab085c266a69e                    tsmfs02vg       concurrent  
hdisk46         00fab085c266a621                    tsmdbvg         concurrent  
hdisk6          00fab085c266a4fe                    None                        
hdisk47         00fab085b5045df1                    tsmhomevg       concurrent  

2017-05-26 07:40:31: Check checklspv.ksh completed successfully: returncode 0
2017-05-26 07:40:31: Runtime: 0 second(s)
2017-05-26 07:40:31: 48% complete - 115 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:31: Running check script 110 of 224: checklspvl.ksh

Description:
------------

Lists the logical volumes per physical volume.

This check script runs the following command:

# lspv -l

Output:
------------

PHYSICAL VOLUME DETAILS FOR hdisk0  (/usr/sbin/lspv -L -l hdisk0)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
hd8                   1       1       00..00..01..00..00    N/A
hd4                   2       2       00..00..02..00..00    /
hd2                   13      13      00..00..13..00..00    /usr
hd9var                10      10      00..00..10..00..00    /var
hd5                   1       1       01..00..00..00..00    N/A
hd6                   32      32      30..01..01..00..00    N/A
hd3                   10      10      00..00..10..00..00    /tmp
hd1                   10      10      00..00..10..00..00    /home
hd10opt               10      10      00..00..10..00..00    /opt
mksysblv              100     100     00..91..09..00..00    /mksysb
livedump              1       1       00..01..00..00..00    /var/adm/ras/livedump
hd11admin             1       1       00..00..01..00..00    /admin
exportlv              20      20      20..00..00..00..00    /export
dumplv0               16      16      00..16..00..00..00    N/A

PHYSICAL VOLUME DETAILS FOR hdisk1  (/usr/sbin/lspv -L -l hdisk1)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
hd8                   1       1       00..00..01..00..00    N/A
hd4                   2       2       00..00..02..00..00    /
hd2                   13      13      00..00..13..00..00    /usr
hd9var                10      10      00..00..10..00..00    /var
hd5                   1       1       01..00..00..00..00    N/A
hd6                   32      32      00..00..32..00..00    N/A
hd3                   10      10      00..00..10..00..00    /tmp
hd1                   10      10      00..00..10..00..00    /home
hd10opt               10      10      00..00..10..00..00    /opt
mksysblv              100     100     00..91..09..00..00    /mksysb
livedump              1       1       00..01..00..00..00    /var/adm/ras/livedump
hd11admin             1       1       00..00..01..00..00    /admin
exportlv              20      20      16..04..00..00..00    /export
dumplv1               16      16      00..16..00..00..00    N/A

PHYSICAL VOLUME DETAILS FOR hdisk2  (/usr/sbin/lspv -L -l hdisk2)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs01lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs01

PHYSICAL VOLUME DETAILS FOR hdisk3  (/usr/sbin/lspv -L -l hdisk3)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb01lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb01

PHYSICAL VOLUME DETAILS FOR hdisk4  (/usr/sbin/lspv -L -l hdisk4)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs02lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs02

PHYSICAL VOLUME DETAILS FOR hdisk5  (/usr/sbin/lspv -L -l hdisk5)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb02lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb02

PHYSICAL VOLUME DETAILS FOR hdisk7  (/usr/sbin/lspv -L -l hdisk7)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs03lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs03

PHYSICAL VOLUME DETAILS FOR hdisk8  (/usr/sbin/lspv -L -l hdisk8)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdbbkp01lv          1790    1790    359..358..358..358..357 /tsmdbbkp/tsmdbbkp01

PHYSICAL VOLUME DETAILS FOR hdisk9  (/usr/sbin/lspv -L -l hdisk9)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmappslv             118     118     24..24..23..24..23    /tsmapps

PHYSICAL VOLUME DETAILS FOR hdisk10  (/usr/sbin/lspv -L -l hdisk10)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs04lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs04

PHYSICAL VOLUME DETAILS FOR hdisk11  (/usr/sbin/lspv -L -l hdisk11)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdbbkp02lv          1790    1790    359..358..358..358..357 /tsmdbbkp/tsmdbbkp02

PHYSICAL VOLUME DETAILS FOR hdisk12  (/usr/sbin/lspv -L -l hdisk12)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmarchloglv          1022    1022    205..205..204..204..204 /tsmarchlog

PHYSICAL VOLUME DETAILS FOR hdisk13  (/usr/sbin/lspv -L -l hdisk13)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs05lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs05

PHYSICAL VOLUME DETAILS FOR hdisk14  (/usr/sbin/lspv -L -l hdisk14)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs06lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs06

PHYSICAL VOLUME DETAILS FOR hdisk15  (/usr/sbin/lspv -L -l hdisk15)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb03lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb03

PHYSICAL VOLUME DETAILS FOR hdisk16  (/usr/sbin/lspv -L -l hdisk16)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs07lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs07

PHYSICAL VOLUME DETAILS FOR hdisk17  (/usr/sbin/lspv -L -l hdisk17)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs08lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs08

PHYSICAL VOLUME DETAILS FOR hdisk18  (/usr/sbin/lspv -L -l hdisk18)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb04lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb04

PHYSICAL VOLUME DETAILS FOR hdisk19  (/usr/sbin/lspv -L -l hdisk19)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs09lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs09

PHYSICAL VOLUME DETAILS FOR hdisk20  (/usr/sbin/lspv -L -l hdisk20)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs10lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs10

PHYSICAL VOLUME DETAILS FOR hdisk21  (/usr/sbin/lspv -L -l hdisk21)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb05lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb05

PHYSICAL VOLUME DETAILS FOR hdisk22  (/usr/sbin/lspv -L -l hdisk22)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs11lv             1022    1022    205..205..204..204..204 /tsmfs01/tsmfs11

PHYSICAL VOLUME DETAILS FOR hdisk23  (/usr/sbin/lspv -L -l hdisk23)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb06lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb06

PHYSICAL VOLUME DETAILS FOR hdisk24  (/usr/sbin/lspv -L -l hdisk24)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs12lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs12

PHYSICAL VOLUME DETAILS FOR hdisk25  (/usr/sbin/lspv -L -l hdisk25)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb07lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb07

PHYSICAL VOLUME DETAILS FOR hdisk26  (/usr/sbin/lspv -L -l hdisk26)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
caalv_private1        1       1       00..01..00..00..00    N/A
caalv_private2        1       1       00..01..00..00..00    N/A
caalv_private3        4       4       00..04..00..00..00    N/A
powerha_crlv          1       1       00..01..00..00..00    N/A

PHYSICAL VOLUME DETAILS FOR hdisk27  (/usr/sbin/lspv -L -l hdisk27)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs13lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs13

PHYSICAL VOLUME DETAILS FOR hdisk28  (/usr/sbin/lspv -L -l hdisk28)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdbbkp03lv          1790    1790    359..358..358..358..357 /tsmdbbkp/tsmdbbkp03

PHYSICAL VOLUME DETAILS FOR hdisk29  (/usr/sbin/lspv -L -l hdisk29)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmactloglv           1198    1198    240..240..239..240..239 /tsmactlog

PHYSICAL VOLUME DETAILS FOR hdisk30  (/usr/sbin/lspv -L -l hdisk30)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs14lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs14

PHYSICAL VOLUME DETAILS FOR hdisk31  (/usr/sbin/lspv -L -l hdisk31)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdbbkp04lv          1790    1790    359..358..358..358..357 /tsmdbbkp/tsmdbbkp04

PHYSICAL VOLUME DETAILS FOR hdisk32  (/usr/sbin/lspv -L -l hdisk32)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmarchlog2lv         1022    1022    205..205..204..204..204 /tsmarchlog2

PHYSICAL VOLUME DETAILS FOR hdisk33  (/usr/sbin/lspv -L -l hdisk33)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs15lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs15

PHYSICAL VOLUME DETAILS FOR hdisk34  (/usr/sbin/lspv -L -l hdisk34)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs16lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs16

PHYSICAL VOLUME DETAILS FOR hdisk35  (/usr/sbin/lspv -L -l hdisk35)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb08lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb08

PHYSICAL VOLUME DETAILS FOR hdisk36  (/usr/sbin/lspv -L -l hdisk36)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs17lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs17

PHYSICAL VOLUME DETAILS FOR hdisk37  (/usr/sbin/lspv -L -l hdisk37)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs18lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs18

PHYSICAL VOLUME DETAILS FOR hdisk38  (/usr/sbin/lspv -L -l hdisk38)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb09lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb09

PHYSICAL VOLUME DETAILS FOR hdisk39  (/usr/sbin/lspv -L -l hdisk39)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs19lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs19

PHYSICAL VOLUME DETAILS FOR hdisk40  (/usr/sbin/lspv -L -l hdisk40)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs20lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs20

PHYSICAL VOLUME DETAILS FOR hdisk41  (/usr/sbin/lspv -L -l hdisk41)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb10lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb10

PHYSICAL VOLUME DETAILS FOR hdisk42  (/usr/sbin/lspv -L -l hdisk42)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmrecoverylv         1598    1598    320..320..319..320..319 /tsmrecovery

PHYSICAL VOLUME DETAILS FOR hdisk43  (/usr/sbin/lspv -L -l hdisk43)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs21lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs21

PHYSICAL VOLUME DETAILS FOR hdisk44  (/usr/sbin/lspv -L -l hdisk44)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb11lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb11

PHYSICAL VOLUME DETAILS FOR hdisk45  (/usr/sbin/lspv -L -l hdisk45)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmfs22lv             1022    1022    205..205..204..204..204 /tsmfs02/tsmfs22

PHYSICAL VOLUME DETAILS FOR hdisk46  (/usr/sbin/lspv -L -l hdisk46)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmdb12lv             1000    1000    00..400..399..201..00 /tsmdb/tsmdb12

PHYSICAL VOLUME DETAILS FOR hdisk47  (/usr/sbin/lspv -L -l hdisk47)
-----------------------------------------------------------------------
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
tsmhomelv             1596    1596    320..319..319..319..319 /tsmhome

2017-05-26 07:40:36: Check checklspvl.ksh completed successfully: returncode 0
2017-05-26 07:40:36: Runtime: 5 second(s)
2017-05-26 07:40:37: 49% complete - 114 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:37: Running check script 111 of 224: checklspvlocked.ksh

Description:
------------

Check for any locked devices.

In AIX 7.1 and up it is possible to lock devices using the lkdev command. This means that general 
device commands, like chdev or rmdev will fail on the device, as no device characteristic changes are 
allowed. The lkdev command can also be used to unlock the device.

To view the locked devices, run:

# lspv | grep locked

2017-05-26 07:40:37: Check checklspvlocked.ksh completed successfully: returncode 0
2017-05-26 07:40:37: Runtime: 0 second(s)
2017-05-26 07:40:37: 49% complete - 113 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:37: Running check script 112 of 224: checklsslot.ksh

Description:
------------

Runs the lsslot -c slot command on the server in order to display the logical slots.

Output:
------------

# Slot                   Description       Device(s)
U8286.42A.21C096X-V1-C0  Virtual I/O Slot  vsa0 

2017-05-26 07:40:37: Check checklsslot.ksh completed successfully: returncode 0
2017-05-26 07:40:37: Runtime: 0 second(s)
2017-05-26 07:40:37: 50% complete - 112 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:37: Running check script 113 of 224: checklsslotpci.ksh

Description:
------------

Runs the lsslot -c pci command on the server in order to display the PCI adapter placement information.

Output:
------------

# Slot                    Description                                        Device(s)
U78C9.001.WZS0TLH-P1-C10  PCI-E capable, Rev 3 8x lane slot with 8x lanes    ent4 ent5 ent6 ent7 
U78C9.001.WZS0TLH-P1-C11  PCI-E capable, Rev 3 8x lane slot with 8x lanes    Empty	
U78C9.001.WZS0TLH-P1-C12  PCI-E capable, Rev 3 8x lane slot with 8x lanes    Empty	
U78C9.001.WZS0TLH-P1-C2   PCI-E capable, Rev 3 8x lane slot with 8x lanes    Empty	
U78C9.001.WZS0TLH-P1-C3   PCI-E capable, Rev 3 16x lane slot with 16x lanes  fcs2 fcs3 
U78C9.001.WZS0TLH-P1-C4   PCI-E capable, Rev 3 8x lane slot with 8x lanes    Empty	
U78C9.001.WZS0TLH-P1-C5   PCI-E capable, Rev 3 16x lane slot with 16x lanes  Empty	
U78C9.001.WZS0TLH-P1-C6   PCI-E capable, Rev 3 16x lane slot with 16x lanes  ent0 ent1 ent2 ent3 
U78C9.001.WZS0TLH-P1-C7   PCI-E capable, Rev 3 16x lane slot with 16x lanes  fcs0 fcs1 
U78C9.001.WZS0TLH-P1-C8   PCI-E capable, Rev 3 8x lane slot with 8x lanes    Empty	
U78C9.001.WZS0TLH-P1-C9   PCI-E capable, Rev 3 8x lane slot with 8x lanes    Empty	

2017-05-26 07:40:37: Check checklsslotpci.ksh completed successfully: returncode 0
2017-05-26 07:40:37: Runtime: 0 second(s)
2017-05-26 07:40:37: 50% complete - 111 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:37: Running check script 114 of 224: checklsslotphb.ksh

Description:
------------

Runs the lsslot -c phb command on the server in order to display the PCI Host Bridges.

Output:
------------

PHB Name  Description              Device(s)
PHB 16    Logical PCI Host Bridge  pci0 fcs0 fcs1 
PHB 19    Logical PCI Host Bridge  pci1 
PHB 20    Logical PCI Host Bridge  pci2 
PHB 21    Logical PCI Host Bridge  pci3 sissas0 
PHB 24    Logical PCI Host Bridge  pci4 ent0 ent1 ent2 ent3 
PHB 27    Logical PCI Host Bridge  pci5 usbhc0 
PHB 28    Logical PCI Host Bridge  pci6 
PHB 29    Logical PCI Host Bridge  pci7 
PHB 30    Logical PCI Host Bridge  pci8 ent4 ent5 ent6 ent7 
PHB 31    Logical PCI Host Bridge  pci9 sissas1 
PHB 32    Logical PCI Host Bridge  pci10 
PHB 33    Logical PCI Host Bridge  pci11 
PHB 40    Logical PCI Host Bridge  pci12 
PHB 41    Logical PCI Host Bridge  pci13 fcs2 fcs3 

2017-05-26 07:40:43: Check checklsslotphb.ksh completed successfully: returncode 0
2017-05-26 07:40:43: Runtime: 6 second(s)
2017-05-26 07:40:43: 50% complete - 110 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:43: Running check script 115 of 224: checklssrca.ksh

Description:
------------

Shows a list of daemons controlled by de Resource Controller.

Output:
------------

Subsystem         Group            PID          Status 
 syslogd          ras              5505670      active
 sendmail         mail             6030056      active
 portmap          portmap          4653902      active
 inetd            tcpip            5505224      active
 xntpd            tcpip            4981656      active
 snmpd            tcpip            5046756      active
 snmpmibd         tcpip            4063826      active
 aixmibd          tcpip            3998014      active
 hrd              hrd              6095612      active
 aso                               4391386      active
 biod             nfs              5898934      active
 rpc.statd        nfs              4980884      active
 rpc.lockd        nfs              5374900      active
 sshd             ssh              5767394      active
 clcomd           caa              4850310      active
 ctrmc            rsct             3802014      active
 pfcdaemon                         4522558      active
 pmperfrec                         5439688      active
 clstrmgrES       cluster          4784222      active
 IBM.HostRM       rsct_rm          9371676      active
 IBM.ConfigRM     rsct_rm          4456860      active
 IBM.DRM          rsct_rm          9240604      active
 IBM.MgmtDomainRM rsct_rm          6488380      active
 IBM.ServiceRM    rsct_rm          6422796      active
 clconfd          caa              6357292      active
 cthags           cthags           8913714      active
 IBM.StorageRM    rsct_rm          5177436      active
 clevmgrdES       cluster          7733650      active
 gsclvmd                           9175790      active
 clinfoES         cluster          4260220      active
 nimesis          nim              18547598     active
 nfsd             nfs              15794690     active
 rpc.mountd       nfs              8061252      active
 tftpd            tcpip            17957060     active
 qdaemon          spooler                       inoperative
 writesrv         spooler                       inoperative
 lpd              spooler                       inoperative
 keyserv          keyserv                       inoperative
 ypbind           yp                            inoperative
 llbd             iforncs                       inoperative
 glbd             iforncs                       inoperative
 cdromd                                         inoperative
 muxatmd          tcpip                         inoperative
 rwhod            tcpip                         inoperative
 hostmibd         tcpip                         inoperative
 dpid2            tcpip                         inoperative
 dhcpcd           tcpip                         inoperative
 dhcpcd6          tcpip                         inoperative
 ndpd-host        tcpip                         inoperative
 ndpd-router      tcpip                         inoperative
 netcd            netcd                         inoperative
 gated            tcpip                         inoperative
 named            tcpip                         inoperative
 routed           tcpip                         inoperative
 iptrace          tcpip                         inoperative
 timed            tcpip                         inoperative
 dhcpsd           tcpip                         inoperative
 dhcpsdv6         tcpip                         inoperative
 dhcprd           tcpip                         inoperative
 mrouted          tcpip                         inoperative
 rsvpd            qos                           inoperative
 policyd          qos                           inoperative
 pxed             tcpip                         inoperative
 binld            tcpip                         inoperative
 dfpd             tcpip                         inoperative
 automountd       autofs                        inoperative
 nfsrgyd          nfs                           inoperative
 gssd             nfs                           inoperative
 cpsd             ike                           inoperative
 tmd              ike                           inoperative
 isakmpd                                        inoperative
 ikev2d                                         inoperative
 iked             ike                           inoperative
 nimsh            nimclient                     inoperative
 IBM.SRVPROXY     ibmsrv                        inoperative
 ctcas            rsct                          inoperative
 IBM.ERRM         rsct_rm                       inoperative
 IBM.AuditRM      rsct_rm                       inoperative
 topsvcs          topsvcs                       inoperative
 grpsvcs          grpsvcs                       inoperative
 grpglsm          grpsvcs                       inoperative
 emsvcs           emsvcs                        inoperative
 emaixos          emsvcs                        inoperative
 IBM.LPRM         rsct_rm                       inoperative
 nimd                                           inoperative

2017-05-26 07:40:43: Check checklssrca.ksh completed successfully: returncode 0
2017-05-26 07:40:43: Runtime: 0 second(s)
2017-05-26 07:40:43: 51% complete - 109 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:43: Running check script 116 of 224: checklsvg.ksh

Description:
------------

Lists all the volume groups on the system, and also provides information on the volume groups that are 
online (varied on), and what their major numbers are.

Output:
------------

Known volume groups (lsvg -L):
---------------------------

rootvg
tsmdbvg
tsmactlogvg
tsmarchlogvg
tsmrecoveryvg
tsmdbbkpvg
tsmfs01vg
tsmfs02vg
caavg_private
tsmhomevg

Volume groups online (lsvg -Lo):
-------------------------------

tsmrecoveryvg
tsmhomevg
tsmfs02vg
tsmfs01vg
tsmdbvg
tsmdbbkpvg
tsmarchlogvg
tsmactlogvg
caavg_private
rootvg

Volume group major numbers (cd /dev; ls -als rootvg tsmdbvg tsmactlogvg tsmarchlogvg tsmrecoveryvg 
tsmdbbkpvg tsmfs01vg tsmfs02vg caavg_private tsmhomevg):
-------------------------------------------------------------

   0 crw-rw----    1 root     system       44,  0 Dec 06 13:23 caavg_private
   0 crw-rw----    1 root     system       10,  0 Nov 29 18:52 rootvg
   0 crw-rw----    1 root     system       46,  0 Dec 06 14:27 tsmactlogvg
   0 crw-rw----    1 root     system       47,  0 Dec 06 14:22 tsmarchlogvg
   0 crw-rw----    1 root     system       49,  0 Dec 06 14:19 tsmdbbkpvg
   0 crw-rw----    1 root     system       45,  0 Dec 06 14:18 tsmdbvg
   0 crw-rw----    1 root     system       50,  0 Dec 06 14:11 tsmfs01vg
   0 crw-rw----    1 root     system       51,  0 Dec 06 14:26 tsmfs02vg
   0 crw-rw----    1 root     system       52,  0 Jan 19 01:27 tsmhomevg
   0 crw-rw----    1 root     system       48,  0 Dec 06 14:21 tsmrecoveryvg

Detailed output for each volume group (lsvg -Lo | lsvg -Li):
--------------------------------------------------------

VOLUME GROUP:       tsmrecoveryvg            VG IDENTIFIER:  00fab08500004c0000000158c361d0a2
VG STATE:           active                   PP SIZE:        256 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      1718 (439808 megabytes)
MAX LVs:            256                      FREE PPs:       2 (512 megabytes)
LVs:                2                        USED PPs:       1716 (439296 megabytes)
OPEN LVs:           2                        QUORUM:         1 (Disabled)
TOTAL PVs:          2                        VG DESCRIPTORS: 3
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         2                        AUTO ON:        no
Concurrent:         Enhanced-Capable         Auto-Concurrent: Disabled
VG Mode:            Concurrent                               
Node ID:            1                        Active Nodes:       2 
MAX PPs per VG:     32768                    MAX PVs:        1024
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
MIRROR POOL STRICT: off                                       
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       tsmhomevg                VG IDENTIFIER:  00fab08500004c0000000159b5045e38
VG STATE:           active                   PP SIZE:        32 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      1597 (51104 megabytes)
MAX LVs:            256                      FREE PPs:       1 (32 megabytes)
LVs:                1                        USED PPs:       1596 (51072 megabytes)
OPEN LVs:           1                        QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        no
Concurrent:         Enhanced-Capable         Auto-Concurrent: Disabled
VG Mode:            Concurrent                               
Node ID:            1                        Active Nodes:       2 
MAX PPs per VG:     32768                    MAX PVs:        1024
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
MIRROR POOL STRICT: off                                       
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       tsmfs02vg                VG IDENTIFIER:  00fab08500004c0000000158c3624528
VG STATE:           active                   PP SIZE:        16384 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      11253 (184369152 megabytes)
MAX LVs:            256                      FREE PPs:       11 (180224 megabytes)
LVs:                11                       USED PPs:       11242 (184188928 megabytes)
OPEN LVs:           11                       QUORUM:         1 (Disabled)
TOTAL PVs:          11                       VG DESCRIPTORS: 11
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         11                       AUTO ON:        no
Concurrent:         Enhanced-Capable         Auto-Concurrent: Disabled
VG Mode:            Concurrent                               
Node ID:            1                        Active Nodes:       2 
MAX PPs per VG:     32768                    MAX PVs:        1024
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
MIRROR POOL STRICT: off                                       
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       tsmfs01vg                VG IDENTIFIER:  00fab08500004c0000000158c36221fd
VG STATE:           active                   PP SIZE:        16384 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      11253 (184369152 megabytes)
MAX LVs:            256                      FREE PPs:       11 (180224 megabytes)
LVs:                11                       USED PPs:       11242 (184188928 megabytes)
OPEN LVs:           11                       QUORUM:         1 (Disabled)
TOTAL PVs:          11                       VG DESCRIPTORS: 11
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         11                       AUTO ON:        no
Concurrent:         Enhanced-Capable         Auto-Concurrent: Disabled
VG Mode:            Concurrent                               
Node ID:            1                        Active Nodes:       2 
MAX PPs per VG:     32768                    MAX PVs:        1024
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
MIRROR POOL STRICT: off                                       
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       tsmdbvg                  VG IDENTIFIER:  00fab08500004c0000000158c36163ad
VG STATE:           active                   PP SIZE:        256 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      23988 (6140928 megabytes)
MAX LVs:            256                      FREE PPs:       11988 (3068928 megabytes)
LVs:                12                       USED PPs:       12000 (3072000 megabytes)
OPEN LVs:           12                       QUORUM:         1 (Disabled)
TOTAL PVs:          12                       VG DESCRIPTORS: 12
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         12                       AUTO ON:        no
Concurrent:         Enhanced-Capable         Auto-Concurrent: Disabled
VG Mode:            Concurrent                               
Node ID:            1                        Active Nodes:       2 
MAX PPs per VG:     32768                    MAX PVs:        1024
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
MIRROR POOL STRICT: off                                       
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       tsmdbbkpvg               VG IDENTIFIER:  00fab08500004c0000000158c361f7c0
VG STATE:           active                   PP SIZE:        4096 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      7164 (29343744 megabytes)
MAX LVs:            256                      FREE PPs:       4 (16384 megabytes)
LVs:                4                        USED PPs:       7160 (29327360 megabytes)
OPEN LVs:           4                        QUORUM:         1 (Disabled)
TOTAL PVs:          4                        VG DESCRIPTORS: 4
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         4                        AUTO ON:        no
Concurrent:         Enhanced-Capable         Auto-Concurrent: Disabled
VG Mode:            Concurrent                               
Node ID:            1                        Active Nodes:       2 
MAX PPs per VG:     32768                    MAX PVs:        1024
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
MIRROR POOL STRICT: off                                       
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       tsmarchlogvg             VG IDENTIFIER:  00fab08500004c0000000158c361ac58
VG STATE:           active                   PP SIZE:        2048 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      2046 (4190208 megabytes)
MAX LVs:            256                      FREE PPs:       2 (4096 megabytes)
LVs:                2                        USED PPs:       2044 (4186112 megabytes)
OPEN LVs:           2                        QUORUM:         1 (Disabled)
TOTAL PVs:          2                        VG DESCRIPTORS: 3
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         2                        AUTO ON:        no
Concurrent:         Enhanced-Capable         Auto-Concurrent: Disabled
VG Mode:            Concurrent                               
Node ID:            1                        Active Nodes:       2 
MAX PPs per VG:     32768                    MAX PVs:        1024
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
MIRROR POOL STRICT: off                                       
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       tsmactlogvg              VG IDENTIFIER:  00fab08500004c0000000158c36189e8
VG STATE:           active                   PP SIZE:        256 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      1199 (306944 megabytes)
MAX LVs:            256                      FREE PPs:       1 (256 megabytes)
LVs:                1                        USED PPs:       1198 (306688 megabytes)
OPEN LVs:           1                        QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        no
Concurrent:         Enhanced-Capable         Auto-Concurrent: Disabled
VG Mode:            Concurrent                               
Node ID:            1                        Active Nodes:       2 
MAX PPs per VG:     32768                    MAX PVs:        1024
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
MIRROR POOL STRICT: off                                       
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       caavg_private            VG IDENTIFIER:  00fab08500004c0000000158d6050c54
VG STATE:           active                   PP SIZE:        64 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      79 (5056 megabytes)
MAX LVs:            256                      FREE PPs:       72 (4608 megabytes)
LVs:                4                        USED PPs:       7 (448 megabytes)
OPEN LVs:           1                        QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        yes
MAX PPs per VG:     32512                                     
MAX PPs per PV:     1016                     MAX PVs:        32
LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    512                      CRITICAL VG:    no
FS SYNC OPTION:     no                                        

VOLUME GROUP:       rootvg                   VG IDENTIFIER:  00fab08500004c0000000158b321f488
VG STATE:           active                   PP SIZE:        1024 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      1116 (1142784 megabytes)
MAX LVs:            256                      FREE PPs:       662 (677888 megabytes)
LVs:                15                       USED PPs:       454 (464896 megabytes)
OPEN LVs:           14                       QUORUM:         1 (Disabled)
TOTAL PVs:          2                        VG DESCRIPTORS: 3
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         2                        AUTO ON:        yes
MAX PPs per VG:     32512                                     
MAX PPs per PV:     1016                     MAX PVs:        32
LTG size (Dynamic): 1024 kilobyte(s)         AUTO SYNC:      yes 
HOT SPARE:          no                       BB POLICY:      non-relocatable
PV RESTRICTION:     none                     INFINITE RETRY: no
DISK BLOCK SIZE:    4096                     CRITICAL VG:    no
FS SYNC OPTION:     no                                        

Disk distribution per volume group (lsvg -Lo | lsvg -Li -p):
----------------------------------------------------------

tsmrecoveryvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk42           active            1599        1           00..00..00..00..01
hdisk9            active            119         1           00..00..00..00..01
tsmhomevg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk47           active            1597        1           00..00..00..00..01
tsmfs02vg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk24           active            1023        1           00..00..00..00..01
hdisk27           active            1023        1           00..00..00..00..01
hdisk30           active            1023        1           00..00..00..00..01
hdisk33           active            1023        1           00..00..00..00..01
hdisk34           active            1023        1           00..00..00..00..01
hdisk36           active            1023        1           00..00..00..00..01
hdisk37           active            1023        1           00..00..00..00..01
hdisk39           active            1023        1           00..00..00..00..01
hdisk40           active            1023        1           00..00..00..00..01
hdisk43           active            1023        1           00..00..00..00..01
hdisk45           active            1023        1           00..00..00..00..01
tsmfs01vg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk2            active            1023        1           00..00..00..00..01
hdisk4            active            1023        1           00..00..00..00..01
hdisk7            active            1023        1           00..00..00..00..01
hdisk10           active            1023        1           00..00..00..00..01
hdisk13           active            1023        1           00..00..00..00..01
hdisk14           active            1023        1           00..00..00..00..01
hdisk16           active            1023        1           00..00..00..00..01
hdisk17           active            1023        1           00..00..00..00..01
hdisk19           active            1023        1           00..00..00..00..01
hdisk20           active            1023        1           00..00..00..00..01
hdisk22           active            1023        1           00..00..00..00..01
tsmdbvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk3            active            1999        999         400..00..00..199..400
hdisk5            active            1999        999         400..00..00..199..400
hdisk15           active            1999        999         400..00..00..199..400
hdisk18           active            1999        999         400..00..00..199..400
hdisk21           active            1999        999         400..00..00..199..400
hdisk23           active            1999        999         400..00..00..199..400
hdisk25           active            1999        999         400..00..00..199..400
hdisk35           active            1999        999         400..00..00..199..400
hdisk38           active            1999        999         400..00..00..199..400
hdisk41           active            1999        999         400..00..00..199..400
hdisk44           active            1999        999         400..00..00..199..400
hdisk46           active            1999        999         400..00..00..199..400
tsmdbbkpvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk8            active            1791        1           00..00..00..00..01
hdisk11           active            1791        1           00..00..00..00..01
hdisk28           active            1791        1           00..00..00..00..01
hdisk31           active            1791        1           00..00..00..00..01
tsmarchlogvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk12           active            1023        1           00..00..00..00..01
hdisk32           active            1023        1           00..00..00..00..01
tsmactlogvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk29           active            1199        1           00..00..00..00..01
caavg_private:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk26           active            79          72          16..09..15..16..16
rootvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk0            active            558         331         61..03..44..111..112
hdisk1            active            558         331         95..00..13..111..112

Logical volumes per volume group (lsvg -Lo | lsvg -Li -l):
--------------------------------------------------------

tsmrecoveryvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmrecoverylv       jfs2       1598    1598    1    open/syncd    /tsmrecovery
tsmappslv           jfs2       118     118     1    open/syncd    /tsmapps
tsmhomevg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmhomelv           jfs2       1596    1596    1    open/syncd    /tsmhome
tsmfs02vg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmfs12lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs12
tsmfs13lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs13
tsmfs14lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs14
tsmfs15lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs15
tsmfs16lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs16
tsmfs17lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs17
tsmfs18lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs18
tsmfs19lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs19
tsmfs20lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs20
tsmfs21lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs21
tsmfs22lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs22
tsmfs01vg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmfs01lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs01
tsmfs02lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs02
tsmfs03lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs03
tsmfs04lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs04
tsmfs05lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs05
tsmfs06lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs06
tsmfs07lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs07
tsmfs08lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs08
tsmfs09lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs09
tsmfs10lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs10
tsmfs11lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs11
tsmdbvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmdb01lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb01
tsmdb02lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb02
tsmdb03lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb03
tsmdb04lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb04
tsmdb05lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb05
tsmdb06lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb06
tsmdb07lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb07
tsmdb08lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb08
tsmdb09lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb09
tsmdb10lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb10
tsmdb11lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb11
tsmdb12lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb12
tsmdbbkpvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmdbbkp01lv        jfs2       1790    1790    1    open/syncd    /tsmdbbkp/tsmdbbkp01
tsmdbbkp02lv        jfs2       1790    1790    1    open/syncd    /tsmdbbkp/tsmdbbkp02
tsmdbbkp03lv        jfs2       1790    1790    1    open/syncd    /tsmdbbkp/tsmdbbkp03
tsmdbbkp04lv        jfs2       1790    1790    1    open/syncd    /tsmdbbkp/tsmdbbkp04
tsmarchlogvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmarchloglv        jfs2       1022    1022    1    open/syncd    /tsmarchlog
tsmarchlog2lv       jfs2       1022    1022    1    open/syncd    /tsmarchlog2
tsmactlogvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmactloglv         jfs2       1198    1198    1    open/syncd    /tsmactlog
caavg_private:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
caalv_private1      boot       1       1       1    closed/syncd  N/A
caalv_private2      boot       1       1       1    closed/syncd  N/A
caalv_private3      boot       4       4       1    open/syncd    N/A
powerha_crlv        boot       1       1       1    closed/syncd  N/A
rootvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
hd5                 boot       1       2       2    closed/syncd  N/A
hd6                 paging     32      64      2    open/syncd    N/A
hd8                 jfs2log    1       2       2    open/syncd    N/A
hd4                 jfs2       2       4       2    open/syncd    /
hd2                 jfs2       13      26      2    open/syncd    /usr
hd9var              jfs2       10      20      2    open/syncd    /var
hd3                 jfs2       10      20      2    open/syncd    /tmp
hd1                 jfs2       10      20      2    open/syncd    /home
hd10opt             jfs2       10      20      2    open/syncd    /opt
hd11admin           jfs2       1       2       2    open/syncd    /admin
mksysblv            jfs2       100     200     2    open/syncd    /mksysb
livedump            jfs2       1       2       2    open/syncd    /var/adm/ras/livedump
dumplv0             sysdump    16      16      1    open/syncd    N/A
dumplv1             sysdump    16      16      1    open/syncd    N/A
exportlv            jfs2       20      40      2    open/syncd    /export

Volume group types:
-------------------

tsmrecoveryvg  vg_type
tsmhomevg  vg_type
tsmfs02vg  vg_type
tsmfs01vg  vg_type
tsmdbvg  vg_type
tsmdbbkpvg  vg_type
tsmarchlogvg  vg_type
tsmactlogvg  vg_type
caavg_private  Regular VG
rootvg  vg_type

2017-05-26 07:40:45: Check checklsvg.ksh completed successfully: returncode 0
2017-05-26 07:40:45: Runtime: 2 second(s)
2017-05-26 07:40:45: 51% complete - 108 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:45: Running check script 117 of 224: checklsvpcfg.ksh

Description:
------------

This will run the lsvpcfg command, if possible. The lsvpcfg command is part of the SDD software, and 
thus will only work if SDD (not SDDPCM) is installed.

2017-05-26 07:40:46: Check checklsvpcfg.ksh completed successfully: returncode 0
2017-05-26 07:40:46: Runtime: 0 second(s)
2017-05-26 07:40:46: 52% complete - 107 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:46: Running check script 118 of 224: checklsvpd.ksh

Description:
------------

Runs lsvpd to list the vital product data.

# /usr/sbin/lsvpd

Output:
------------

*VC 5.0
*TM IBM,8286-42A
*SE IBM,0221C096X
*PI 00FAB085
*N5 828621-B085W  52FE00-06AB00C62851137062A2E4854C400240041C3004800            
                                    00                                          
      00000000000000000P5555000000402EFFFF    00000000              0000
*N6 828621-B085W52FE00-06AB00C62851137062A2E488212000000403C
*OS AIX 7.1.0.0
*FC ????????
*DS System VPD
*YL U8286.42A.21C096X
*RT VSYS
*FG XXSV
*BR S0
*SE 21C096X
*TM 8286-42A
*SU 0004AC1C6A50
*WN C05076099BCD
*FV SV840_139
*VK ipzSeries
*FC ????????
*DS CEC
*YL U78C9.001.WZS0TLH
*RT VCEN
*FG XXEV
*BR S0
*SE WZS0TLH
*TM 78C9-001
*CI 8286-42A 21C096X
*RK 0000000000000000
*FC 78C9-001
*VK ipzSeries
*FC ????????
*DS I/O BACKPLANE   
*YL U78C9.001.WZS0TLH-P1
*RT VINI
*FG XXBP
*CC 2CD4
*SN YL10UF66M032
*CE 1
*VZ 01
*FN 01DH349
*PN 01DH347
*PR 2100000000000000
*HE 0002
*CT 80F30026
*HW 0006
*B3 000000000001
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS NATIVE I/O CARD 
*YL U78C9.001.WZS0TLH-P1-C1
*RT VINI
*FG XXBX
*CC 2B0B
*SN YL10UF66A0L0
*CE 1
*VZ 01
*FN 00E1960
*PN 00E3809
*HE 0001
*CT 80B50000
*HW 0001
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS ANCHOR          
*YL U78C9.001.WZS0TLH-P1-C13
*RT VINI
*FG XXAV
*CC 52FE
*SN YL10006AB00C
*CE 1
*VZ 01
*FN 00E2147
*PN 00E2148
*PR 8100300000000000
*HE 0010
*CT 40B40000
*HW 0001
*B3 000000000001
*B4 00
*B7 000000000000000000000000
*B9 435362851137062A2E485350FA3DEAB0D290BFCC4D3109B81194CFDCD1F14D32C602CFABA0D9
F4114D33C4E294CE10C773794D342E54079E96FEDC6C
*VK ipzSeries
*FC ????????
*DS Memory DIMM
*YL U78C9.001.WZS0TLH-P1-C16
*RT VINI
*FG XXMS
*CC 31E9
*SN YH10M168Z0G2
*CE 1
*VZ 17
*FN 00LP740
*PN 00LP740
*PR 4900000000010000
*SZ 0032768
*HE 0001
*CT 00000000
*HW 0100
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS Memory DIMM
*YL U78C9.001.WZS0TLH-P1-C18
*RT VINI
*FG XXMS
*CC 31E9
*SN YH10M168Z0G1
*CE 1
*VZ 17
*FN 00LP740
*PN 00LP740
*PR 4900000000010000
*SZ 0032768
*HE 0001
*CT 00000000
*HW 0100
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS Memory DIMM
*YL U78C9.001.WZS0TLH-P1-C21
*RT VINI
*FG XXMS
*CC 31E9
*SN YH10M16BH1JH
*CE 1
*VZ 17
*FN 00LP740
*PN 00LP740
*PR 4900000000010000
*SZ 0032768
*HE 0001
*CT 00000000
*HW 0100
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS Memory DIMM
*YL U78C9.001.WZS0TLH-P1-C23
*RT VINI
*FG XXMS
*CC 31E9
*SN YH10M16BA1W3
*CE 1
*VZ 17
*FN 00LP740
*PN 00LP740
*PR 4900000000010000
*SZ 0032768
*HE 0001
*CT 00000000
*HW 0100
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS Memory DIMM
*YL U78C9.001.WZS0TLH-P1-C24
*RT VINI
*FG XXMS
*CC 31E9
*SN YH10M168Z0G3
*CE 1
*VZ 17
*FN 00LP740
*PN 00LP740
*PR 4900000000010000
*SZ 0032768
*HE 0001
*CT 00000000
*HW 0100
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS Memory DIMM
*YL U78C9.001.WZS0TLH-P1-C26
*RT VINI
*FG XXMS
*CC 31E9
*SN YH10M168Z0FZ
*CE 1
*VZ 17
*FN 00LP740
*PN 00LP740
*PR 4900000000010000
*SZ 0032768
*HE 0001
*CT 00000000
*HW 0100
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS Memory DIMM
*YL U78C9.001.WZS0TLH-P1-C29
*RT VINI
*FG XXMS
*CC 31E9
*SN YH10M16BG1BF
*CE 1
*VZ 17
*FN 00LP740
*PN 00LP740
*PR 4900000000010000
*SZ 0032768
*HE 0001
*CT 00000000
*HW 0100
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS Memory DIMM
*YL U78C9.001.WZS0TLH-P1-C31
*RT VINI
*FG XXMS
*CC 31E9
*SN YH10M16BH1HW
*CE 1
*VZ 17
*FN 00LP740
*PN 00LP740
*PR 4900000000010000
*SZ 0032768
*HE 0001
*CT 00000000
*HW 0100
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS 12-WAY PROC CUOD
*YL U78C9.001.WZS0TLH-P1-C32
*RT VINI
*FG XXPF
*CC 54E3
*SN YA1933574201
*FN 00FX516
*PN 00FX736
*HE 0001
*CT 00000000
*HW 0001
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*PR 3500600111008001
*VZ 01
*CE 1
*VK ipzSeries
*FC ????????
*DS 12-WAY PROC CUOD
*YL U78C9.001.WZS0TLH-P1-C33
*RT VINI
*FG XXPF
*CC 54E3
*SN YA1933450356
*FN 00FX516
*PN 00FX736
*HE 0001
*CT 00000000
*HW 0001
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*PR 3500600111008001
*VZ 01
*CE 1
*VK ipzSeries
*FC ????????
*DS CEC OP PANEL    
*YL U78C9.001.WZS0TLH-D1
*RT VINI
*FG XXOP
*CC 2B08
*SN YL12UF69203P
*CE 1
*VZ 02
*FN 00RR573
*PN 00RR578
*HE 0001
*CT 80B50000
*HW 0003
*B3 000000000000
*B4 00
*B7 000000000000000000000000
*VK ipzSeries
*FC ????????
*DS IBM PS         
*YL U78C9.001.WZS0TLH-E1
*RT VINI
*FG XXPS
*CC 2B1D
*SN YL10KY684858
*FN  01AF895
*PN 01AF895
*FL E1
*VK ipzSeries
*FC ????????
*DS IBM PS         
*YL U78C9.001.WZS0TLH-E2
*RT VINI
*FG XXPS
*CC 2B1D
*SN YL10KY68485A
*FN  01AF895
*PN 01AF895
*FL E2
*VK ipzSeries
*FC ????????
*DS IBM PS         
*YL U78C9.001.WZS0TLH-E3
*RT VINI
*FG XXPS
*CC 2B1D
*SN YL10KY68487D
*FN  01AF895
*PN 01AF895
*FL E3
*VK ipzSeries
*FC ????????
*DS IBM PS         
*YL U78C9.001.WZS0TLH-E4
*RT VINI
*FG XXPS
*CC 2B1D
*SN YL10KY68487E
*FN  01AF895
*PN 01AF895
*FL E4
*VK ipzSeries
*FC ????????
*DS 4U 80MM CR FAN  
*YL U78C9.001.WZS0TLH-A1
*RT VINI
*FG XXAM
*CC 2B1F
*SN YL12WY4600A1
*PN 00FV629
*FN 00FV629
*FL A1                  
*VK ipzSeries
*FC ????????
*DS 4U 80MM CR FAN  
*YL U78C9.001.WZS0TLH-A2
*RT VINI
*FG XXAM
*CC 2B1F
*SN YL12WY4600A2
*PN 00FV629
*FN 00FV629
*FL A2                  
*VK ipzSeries
*FC ????????
*DS 4U 80MM CR FAN  
*YL U78C9.001.WZS0TLH-A3
*RT VINI
*FG XXAM
*CC 2B1F
*SN YL12WY4600A3
*PN 00FV629
*FN 00FV629
*FL A3                  
*VK ipzSeries
*FC ????????
*DS 4U 80MM CR FAN  
*YL U78C9.001.WZS0TLH-A4
*RT VINI
*FG XXAM
*CC 2B1F
*SN YL12WY4600A4
*PN 00FV629
*FN 00FV629
*FL A4                  
*VK ipzSeries
*FC ????????
*DS VSBPD12M1 6GSAS 
*YL U78C9.001.WZS0TLH-P2
*RT VINI
*FG XXDB
*CC 2B09
*SN YL10UF6880GR
*FN  01DH345
*PN 01DH343
*CE 3
*VZ 03
*B2 500507606BEBAE000000000000000100
*WI 
*VK RS6K
*FC ????????
*DS System Firmware
*YL U8286.42A.21C096X-Y1
*CL Phyp_1 14502017030180A00701
*CL PFW 00302017030381CF0681
*CL FSP_Fil 15082017031281E00109
*CL FipS_BU 15082017031281E00208
*MI SV860_082 SV860_082 SV860_082
*ML FW860.20 FW860.20 FW860.20
*MG 20170317 20170317 20170317
*ME 20191221
*FC ????????
*DS PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
*AX fcs0
*PL 00-00
*CD 101403f1
*PN 00E3495
*SN 1A63000934
*EC D77535
*CC 577F
*MF 001A
*FN 00E3496
*ZM 3
*RM 100300
*Z0 0000000B
*Z1 00000030
*Z2 00000000
*Z3 08090000
*Z4 01000001
*Z5 2E323532
*Z6 2E323532
*Z7 C0022B40
*Z8 20000088ADF49803
*Z9 10.2.252.1919
*ZA 10.2.252.1919
*ZB 00000000
*ZC 00040000
*ZD 000000FF
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
*AX fcs1
*PL 00-01
*CD 101403f1
*PN 00E3495
*SN 1A63000934
*EC D77535
*CC 577F
*MF 001A
*FN 00E3496
*ZM 3
*RM 100300
*Z0 0000000B
*Z1 00000030
*Z2 00000000
*Z3 08090000
*Z4 01010001
*Z5 2E323532
*Z6 2E323532
*Z7 C0022B40
*Z8 20000088ADF49804
*Z9 10.2.252.1919
*ZA 10.2.252.1919
*ZB 00000000
*ZC 00040000
*ZD 000000FF
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS PCIe3 x8 SAS RAID Internal Adapter 6Gb
*CD 101403ff
*YL U78C9.001.WZS0TLH-P1-C14-T1
*PN 01DH551
*FN 01DH550
*SN YL10UE68Y169
*MN 00UE
*EC 0
*RM 15511800
*CC 57D7
*Z1 1
*Z2 2D35
*FC ????????
*DS PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
*AX ent0
*PL 04-00
*CD 10140493
*FN 00E2715
*EC D77452
*CC 2CC3
*PN 00E2719
*FC EN0S
*SN Y250NY66PJ81
*MN 98BE94689598
*RM 30100150
*YL U78C9.001.WZS0TLH-P1-C6-T1
*FC ????????
*DS PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
*AX ent1
*PL 04-01
*CD 10140493
*FN 00E2715
*EC D77452
*CC 2CC3
*PN 00E2719
*FC EN0S
*SN Y250NY66PJ81
*MN 98BE94689598
*RM 30100150
*YL U78C9.001.WZS0TLH-P1-C6-T2
*FC ????????
*DS PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
*AX ent2
*PL 04-02
*CD 10140494
*FN 00E2715
*EC D77452
*CC 2CC3
*PN 00E2719
*FC EN0S
*SN Y250NY66PJ81
*MN 98BE94689598
*RM 30100150
*YL U78C9.001.WZS0TLH-P1-C6-T3
*FC ????????
*DS PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
*AX ent3
*PL 04-03
*CD 10140494
*FN 00E2715
*EC D77452
*CC 2CC3
*PN 00E2719
*FC EN0S
*SN Y250NY66PJ81
*MN 98BE94689598
*RM 30100150
*YL U78C9.001.WZS0TLH-P1-C6-T4
*FC ????????
*DS PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
*AX ent4
*PL 08-00
*CD 10140493
*FN 00E2715
*EC D77452
*CC 2CC3
*PN 00E2719
*FC EN0S
*SN Y250NY66NJ9E
*MN 98BE94688C3C
*RM 30100150
*YL U78C9.001.WZS0TLH-P1-C10-T1
*FC ????????
*DS PCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304)
*AX ent5
*PL 08-01
*CD 10140493
*FN 00E2715
*EC D77452
*CC 2CC3
*PN 00E2719
*FC EN0S
*SN Y250NY66NJ9E
*MN 98BE94688C3C
*RM 30100150
*YL U78C9.001.WZS0TLH-P1-C10-T2
*FC ????????
*DS PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
*AX ent6
*PL 08-02
*CD 10140494
*FN 00E2715
*EC D77452
*CC 2CC3
*PN 00E2719
*FC EN0S
*SN Y250NY66NJ9E
*MN 98BE94688C3C
*RM 30100150
*YL U78C9.001.WZS0TLH-P1-C10-T3
*FC ????????
*DS PCIe2 4-Port Adapter (1GbE RJ45) (e4148a1614109404)
*AX ent7
*PL 08-03
*CD 10140494
*FN 00E2715
*EC D77452
*CC 2CC3
*PN 00E2719
*FC EN0S
*SN Y250NY66NJ9E
*MN 98BE94688C3C
*RM 30100150
*YL U78C9.001.WZS0TLH-P1-C10-T4
*FC ????????
*DS PCIe3 x8 SAS RAID Internal Adapter 6Gb
*CD 101403ff
*YL U78C9.001.WZS0TLH-P1-C15-T1
*PN 01DH551
*FN 01DH550
*SN YL10UE689145
*MN 00UE
*EC 0
*RM 15511800
*CC 57D7
*Z1 1
*Z2 2D35
*FC ????????
*DS PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
*AX fcs2
*PL 0D-00
*CD 101403f1
*PN 00E3495
*SN 1A63000923
*EC D77535
*CC 577F
*MF 001A
*FN 00E3496
*ZM 3
*RM 100300
*Z0 0000000B
*Z1 00000030
*Z2 00000000
*Z3 08090000
*Z4 01000001
*Z5 2E323532
*Z6 2E323532
*Z7 C0022B40
*Z8 20000088ADF497D0
*Z9 10.2.252.1919
*ZA 10.2.252.1919
*ZB 00000000
*ZC 00040000
*ZD 000000FF
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS PCIe2 2-Port 16Gb FC Adapter (df1000e21410f103)
*AX fcs3
*PL 0D-01
*CD 101403f1
*PN 00E3495
*SN 1A63000923
*EC D77535
*CC 577F
*MF 001A
*FN 00E3496
*ZM 3
*RM 100300
*Z0 0000000B
*Z1 00000030
*Z2 00000000
*Z3 08090000
*Z4 01010001
*Z5 2E323532
*Z6 2E323532
*Z7 C0022B40
*Z8 20000088ADF497D1
*Z9 10.2.252.1919
*ZA 10.2.252.1919
*ZB 00000000
*ZC 00040000
*ZD 000000FF
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS Controller SAS Protocol
*AX sas0
*PL 03-00-00
*YL U78C9.001.WZS0TLH-P1-C14-T1
*FC ????????
*DS Controller SATA Protocol
*AX sata0
*PL 03-00-00
*YL U78C9.001.WZS0TLH-P1-C14-T1
*FC ????????
*DS Controller SAS Protocol
*AX sas1
*PL 09-00-00
*YL U78C9.001.WZS0TLH-P1-C15-T1
*FC ????????
*DS Controller SATA Protocol
*AX sata1
*PL 09-00-00
*YL U78C9.001.WZS0TLH-P1-C15-T1
*FC ????????
*DS SAS 4K Disk Drive
*AX hdisk0
*PL 03-00-00
*MF IBM     
*TM HUC101860CS420  
*FN 00E9959     
*RL 4E393930
*SN 03G0NM2H
*EC N46243    
*PN 00E9955     
*Z0 000006329F001002
*Z1 C4IPN990    
*Z2 0068
*Z3 15003
*Z4 
*Z5 22
*Z6 N46243    
*YL U78C9.001.WZS0TLH-P2-D7
*FC ????????
*DS SAS Enclosure Services Device
*AX ses0
*PL 03-00-00
*RM   03
*YL U78C9.001.WZS0TLH-P2-Y1
*FC ????????
*DS SATA DVD-RAM Drive
*AX cd0
*PL 03-00-00
*MF IBM.    
*TM RMBO0140572     
*RL IP02
*Z0 058000325B000000
*PN 00RW615     
*EC N99024    
*FN 00RW611     
*YL U78C9.001.WZS0TLH-P2-D27
*FC ????????
*DS SAS 4K Disk Drive
*AX hdisk1
*PL 09-00-00
*MF IBM     
*TM HUC101860CS420  
*FN 00E9959     
*RL 4E393930
*SN 03GMB5LA
*EC N46243    
*PN 00E9955     
*Z0 000006329F001002
*Z1 C4IPN990    
*Z2 0068
*Z3 16198
*Z4 
*Z5 22
*Z6 N46243    
*YL U78C9.001.WZS0TLH-P2-D1
*FC ????????
*DS SAS Enclosure Services Device
*AX ses1
*PL 09-00-00
*RM   03
*YL U78C9.001.WZS0TLH-P2-Y1
*FC ????????
*DS FC SCSI I/O Controller Protocol Device
*AX fscsi0
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS FC SCSI I/O Controller Protocol Device
*AX fscsi1
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS FC SCSI I/O Controller Protocol Device
*AX fscsi2
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS FC SCSI I/O Controller Protocol Device
*AX fscsi3
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk0
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk1
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk2
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk3
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk4
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk5
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk6
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk7
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk8
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk9
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk10
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk11
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk12
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk13
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk14
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk15
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk16
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk17
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk18
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk19
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk20
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk21
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk22
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk23
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk24
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk25
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk26
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk27
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk28
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk29
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk30
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk31
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk32
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk33
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk34
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk35
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk36
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk37
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk38
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk39
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk40
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk41
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk42
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk43
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk44
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk45
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk46
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk47
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk48
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk49
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk50
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk51
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk52
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk53
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk54
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk55
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk56
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk57
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk58
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk59
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk60
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk61
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk62
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk63
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk64
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk65
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk66
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk67
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk68
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk69
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk70
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk71
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk72
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk73
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk74
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk75
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk76
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk77
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk78
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk79
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk80
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk81
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk82
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk83
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk84
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk85
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk86
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk87
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk88
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk89
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk90
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk91
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk92
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk93
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk94
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk95
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk96
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk97
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk98
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk99
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk100
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk101
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk102
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk103
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk104
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk105
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk106
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk107
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk108
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk109
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk110
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk111
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk112
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk113
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk114
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk115
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk116
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk117
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk118
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk119
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk120
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk121
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk122
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk123
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk124
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk125
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk126
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk127
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk128
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk129
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk130
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk131
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk132
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk133
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk134
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk135
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk136
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk137
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk138
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk139
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk140
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk141
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk142
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk143
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk144
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk145
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk146
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk147
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk148
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk149
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk150
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk151
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk152
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk153
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk154
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk155
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk156
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk157
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk158
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk159
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk160
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk161
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk162
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk163
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk164
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk165
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk166
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk167
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk168
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk169
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk170
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk171
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk172
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk173
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk174
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk175
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk176
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk177
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk178
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk179
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk180
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk181
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk182
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk183
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk184
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk185
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk186
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk187
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk188
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk189
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk190
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk191
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk192
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk193
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk194
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk195
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk196
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk197
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk198
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk199
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk200
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk201
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk202
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk203
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk204
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk205
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk206
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk207
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk208
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk209
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk210
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk211
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk212
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk213
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk214
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk215
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk216
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk217
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk218
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk219
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk220
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk221
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk222
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk223
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk224
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk225
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk226
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk227
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk228
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk229
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk230
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk231
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk232
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk233
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk234
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk235
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk236
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk237
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk238
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk239
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk240
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk241
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk242
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk243
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk244
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk245
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk246
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk247
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk248
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk249
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk250
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk251
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk252
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk253
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk254
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk255
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk256
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk257
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk258
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk259
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk260
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk261
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk262
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk263
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk264
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk265
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk266
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk267
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk268
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk269
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk270
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk271
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk272
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk273
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk274
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk275
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk276
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk277
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk278
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk279
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk280
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk281
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk282
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk283
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk284
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk285
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk286
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk287
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk288
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk289
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk290
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk291
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk292
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk293
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk294
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk295
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk296
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk297
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk298
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk299
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk300
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk301
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk302
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk303
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk304
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk305
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk306
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk307
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk308
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk309
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk310
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk311
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk312
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk313
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk314
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk315
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk316
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk317
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk318
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk319
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk320
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk321
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk322
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk323
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk324
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk325
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk326
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk327
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk328
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk329
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk330
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk331
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk332
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk333
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk334
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk335
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk336
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk337
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk338
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk339
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk340
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk341
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk342
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk343
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk344
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk345
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk346
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk347
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk348
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk349
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk350
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk351
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk352
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk353
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk354
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk355
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk356
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk357
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk358
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk359
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk2
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000023
*Z2 SSN:87390
*Z3 IND:33
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS10
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L20000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk3
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000013
*Z2 SSN:87390
*Z3 IND:17
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db10
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L10000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk4
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000025
*Z2 SSN:87390
*Z3 IND:35
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS12
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L22000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk5
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000015
*Z2 SSN:87390
*Z3 IND:19
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db12
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L12000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk7
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000027
*Z2 SSN:87390
*Z3 IND:37
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS14
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L24000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk8
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000017
*Z2 SSN:87390
*Z3 IND:21
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_dbbkp02
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L14000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk9
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000009
*Z2 SSN:87390
*Z3 IND:7
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_apps
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L4000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk10
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000029
*Z2 SSN:87390
*Z3 IND:39
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS16
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L26000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk11
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000019
*Z2 SSN:87390
*Z3 IND:23
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_dbbkp04
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L16000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk12
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000006
*Z2 SSN:87390
*Z3 IND:4
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_archlog2
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L6000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk13
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000002b
*Z2 SSN:87390
*Z3 IND:41
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS18
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L28000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk14
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000001b
*Z2 SSN:87390
*Z3 IND:25
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS02
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L18000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk15
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000000b
*Z2 SSN:87390
*Z3 IND:9
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db02
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L8000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk16
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000002d
*Z2 SSN:87390
*Z3 IND:43
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS20
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2A000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk17
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000001d
*Z2 SSN:87390
*Z3 IND:27
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS04
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1A000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk18
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000000d
*Z2 SSN:87390
*Z3 IND:11
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db04
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LA000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk19
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000002f
*Z2 SSN:87390
*Z3 IND:45
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS22
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2C000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk20
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000001f
*Z2 SSN:87390
*Z3 IND:29
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS06
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1C000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk21
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000000f
*Z2 SSN:87390
*Z3 IND:13
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db06
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LC000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk22
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000021
*Z2 SSN:87390
*Z3 IND:31
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS08
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1E000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk23
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000011
*Z2 SSN:87390
*Z3 IND:15
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db08
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LE000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk24
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000024
*Z2 SSN:87390
*Z3 IND:34
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS11
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L21000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk25
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000014
*Z2 SSN:87390
*Z3 IND:18
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db11
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L11000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk26
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000003
*Z2 SSN:87390
*Z3 IND:1
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:CLrep1
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk27
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000026
*Z2 SSN:87390
*Z3 IND:36
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS13
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L23000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk28
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000016
*Z2 SSN:87390
*Z3 IND:20
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_dbbkp01
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L13000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk29
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000000a
*Z2 SSN:87390
*Z3 IND:8
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_actlog
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L3000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk30
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000028
*Z2 SSN:87390
*Z3 IND:38
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS15
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L25000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk31
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000018
*Z2 SSN:87390
*Z3 IND:22
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_dbbkp03
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L15000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk32
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000005
*Z2 SSN:87390
*Z3 IND:3
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_archlog1
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L5000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk33
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000002a
*Z2 SSN:87390
*Z3 IND:40
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS17
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L27000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk34
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000001a
*Z2 SSN:87390
*Z3 IND:24
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS01
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L17000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk35
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000008
*Z2 SSN:87390
*Z3 IND:6
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db01
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L7000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk36
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000002c
*Z2 SSN:87390
*Z3 IND:42
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS19
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L29000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk37
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000001c
*Z2 SSN:87390
*Z3 IND:26
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS03
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L19000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk38
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000000c
*Z2 SSN:87390
*Z3 IND:10
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db03
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L9000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk39
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000002e
*Z2 SSN:87390
*Z3 IND:44
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS21
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2B000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk40
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000001e
*Z2 SSN:87390
*Z3 IND:28
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS05
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1B000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk41
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-0000000e
*Z2 SSN:87390
*Z3 IND:12
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db05
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LB000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk42
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000007
*Z2 SSN:87390
*Z3 IND:5
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_recovery
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2D000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk43
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000020
*Z2 SSN:87390
*Z3 IND:30
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS07
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1D000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk44
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000010
*Z2 SSN:87390
*Z3 IND:14
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db07
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LD000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk45
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000022
*Z2 SSN:87390
*Z3 IND:32
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_FS09
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1F000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk46
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000012
*Z2 SSN:87390
*Z3 IND:16
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:SP_db09
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LF000000000000
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk6
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000004
*Z2 SSN:87390
*Z3 IND:2
*Z4 CID:59637
*Z5 ETH0IP:ad180539
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:CLrep2
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2000000000000
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk360
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk361
*PL 00-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk362
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk363
*PL 00-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C7-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk364
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk365
*PL 0D-00-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T1
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk366
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS DELL Compellent Storage subsystem disk
*AX pdisk367
*PL 0D-01-01
*CD 101403f1
*YL U78C9.001.WZS0TLH-P1-C3-T2
*FC ????????
*DS MPIO Compellent Fibre Channel Disk Drive
*AX hdisk47
*PL 00-00-01
*MF COMPELNT
*TM Compellent Vol 
*RL 0607
*Z0 00000532FA181002
*Z1 0000e8f4-00000030
*Z2 SSN:87390
*Z3 IND:46
*Z4 CID:87390
*Z5 ETH0IP:ad18053a
*Z6 MIP:ad18053b
*Z7 SysName:DTC-GRT-CML01-87390
*Z8 VolName:tsmhome
*YL U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2E000000000000

2017-05-26 07:40:47: Check checklsvpd.ksh completed successfully: returncode 0
2017-05-26 07:40:47: Runtime: 1 second(s)
2017-05-26 07:40:47: 52% complete - 106 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:47: Running check script 119 of 224: checklv.ksh

Description:
------------

Shows the logical volumes within each volume group.

Output:
------------

tsmrecoveryvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmrecoverylv       jfs2       1598    1598    1    open/syncd    /tsmrecovery
tsmappslv           jfs2       118     118     1    open/syncd    /tsmapps

tsmhomevg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmhomelv           jfs2       1596    1596    1    open/syncd    /tsmhome

tsmfs02vg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmfs12lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs12
tsmfs13lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs13
tsmfs14lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs14
tsmfs15lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs15
tsmfs16lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs16
tsmfs17lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs17
tsmfs18lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs18
tsmfs19lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs19
tsmfs20lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs20
tsmfs21lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs21
tsmfs22lv           jfs2       1022    1022    1    open/syncd    /tsmfs02/tsmfs22

tsmfs01vg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmfs01lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs01
tsmfs02lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs02
tsmfs03lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs03
tsmfs04lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs04
tsmfs05lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs05
tsmfs06lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs06
tsmfs07lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs07
tsmfs08lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs08
tsmfs09lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs09
tsmfs10lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs10
tsmfs11lv           jfs2       1022    1022    1    open/syncd    /tsmfs01/tsmfs11

tsmdbvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmdb01lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb01
tsmdb02lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb02
tsmdb03lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb03
tsmdb04lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb04
tsmdb05lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb05
tsmdb06lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb06
tsmdb07lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb07
tsmdb08lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb08
tsmdb09lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb09
tsmdb10lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb10
tsmdb11lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb11
tsmdb12lv           jfs2       1000    1000    1    open/syncd    /tsmdb/tsmdb12

tsmdbbkpvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmdbbkp01lv        jfs2       1790    1790    1    open/syncd    /tsmdbbkp/tsmdbbkp01
tsmdbbkp02lv        jfs2       1790    1790    1    open/syncd    /tsmdbbkp/tsmdbbkp02
tsmdbbkp03lv        jfs2       1790    1790    1    open/syncd    /tsmdbbkp/tsmdbbkp03
tsmdbbkp04lv        jfs2       1790    1790    1    open/syncd    /tsmdbbkp/tsmdbbkp04

tsmarchlogvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmarchloglv        jfs2       1022    1022    1    open/syncd    /tsmarchlog
tsmarchlog2lv       jfs2       1022    1022    1    open/syncd    /tsmarchlog2

tsmactlogvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
tsmactloglv         jfs2       1198    1198    1    open/syncd    /tsmactlog

caavg_private:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
caalv_private1      boot       1       1       1    closed/syncd  N/A
caalv_private2      boot       1       1       1    closed/syncd  N/A
caalv_private3      boot       4       4       1    open/syncd    N/A
powerha_crlv        boot       1       1       1    closed/syncd  N/A

rootvg:
LV NAME             TYPE       LPs     PPs     PVs  LV STATE      MOUNT POINT
hd5                 boot       1       2       2    closed/syncd  N/A
hd6                 paging     32      64      2    open/syncd    N/A
hd8                 jfs2log    1       2       2    open/syncd    N/A
hd4                 jfs2       2       4       2    open/syncd    /
hd2                 jfs2       13      26      2    open/syncd    /usr
hd9var              jfs2       10      20      2    open/syncd    /var
hd3                 jfs2       10      20      2    open/syncd    /tmp
hd1                 jfs2       10      20      2    open/syncd    /home
hd10opt             jfs2       10      20      2    open/syncd    /opt
hd11admin           jfs2       1       2       2    open/syncd    /admin
mksysblv            jfs2       100     200     2    open/syncd    /mksysb
livedump            jfs2       1       2       2    open/syncd    /var/adm/ras/livedump
dumplv0             sysdump    16      16      1    open/syncd    N/A
dumplv1             sysdump    16      16      1    open/syncd    N/A
exportlv            jfs2       20      40      2    open/syncd    /export

2017-05-26 07:40:48: Check checklv.ksh completed successfully: returncode 0
2017-05-26 07:40:48: Runtime: 1 second(s)
2017-05-26 07:40:48: 53% complete - 105 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:48: Running check script 120 of 224: checklvfscreate.ksh

Description:
------------

Generates the commands needed to re-create all the non-rootvg logical volumes and file systems. This 
can be very useful when having to do a full recovery of a server.

Please note that this script generates the commands needed, assuming the volume groups already exist. 
It will not provide the commands needed to recreate the volume groups. This is, because when recovering 
a server, a different physical machine may be used, with different disks. In that case, it makes more 
sense to create a new volume group, including all the necessary disks. In that case, the commands 
generated by this script, need to be updated to match any new volume group name.

The mklv commands generated by this script, automatically spreads all the PPs over the available disks 
in the volume group by using the "-e x" option, in order to best use all the disk for high disk 
performance.

Output:
------------

mklv -e x -y tsmappslv -t jfs2 tsmrecoveryvg 30208M
chlv -U root -G system -P 660 tsmappslv
mklv -e x -y tsmrecoverylv -t jfs2 tsmrecoveryvg 409088M
chlv -U root -G system -P 660 tsmrecoverylv
mklv -e x -y tsmhomelv -t jfs2 tsmhomevg 51072M
chlv -U root -G system -P 660 tsmhomelv
mklv -e x -y tsmfs12lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs12lv
mklv -e x -y tsmfs13lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs13lv
mklv -e x -y tsmfs14lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs14lv
mklv -e x -y tsmfs15lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs15lv
mklv -e x -y tsmfs16lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs16lv
mklv -e x -y tsmfs17lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs17lv
mklv -e x -y tsmfs18lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs18lv
mklv -e x -y tsmfs19lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs19lv
mklv -e x -y tsmfs20lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs20lv
mklv -e x -y tsmfs21lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs21lv
mklv -e x -y tsmfs22lv -t jfs2 tsmfs02vg 16744448M
chlv -U root -G system -P 660 tsmfs22lv
mklv -e x -y tsmfs01lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs01lv
mklv -e x -y tsmfs02lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs02lv
mklv -e x -y tsmfs03lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs03lv
mklv -e x -y tsmfs04lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs04lv
mklv -e x -y tsmfs05lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs05lv
mklv -e x -y tsmfs06lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs06lv
mklv -e x -y tsmfs07lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs07lv
mklv -e x -y tsmfs08lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs08lv
mklv -e x -y tsmfs09lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs09lv
mklv -e x -y tsmfs10lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs10lv
mklv -e x -y tsmfs11lv -t jfs2 tsmfs01vg 16744448M
chlv -U root -G system -P 660 tsmfs11lv
mklv -e x -y tsmdb01lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb01lv
mklv -e x -y tsmdb02lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb02lv
mklv -e x -y tsmdb03lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb03lv
mklv -e x -y tsmdb04lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb04lv
mklv -e x -y tsmdb05lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb05lv
mklv -e x -y tsmdb06lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb06lv
mklv -e x -y tsmdb07lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb07lv
mklv -e x -y tsmdb08lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb08lv
mklv -e x -y tsmdb09lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb09lv
mklv -e x -y tsmdb10lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb10lv
mklv -e x -y tsmdb11lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb11lv
mklv -e x -y tsmdb12lv -t jfs2 tsmdbvg 256000M
chlv -U root -G system -P 660 tsmdb12lv
mklv -e x -y tsmdbbkp01lv -t jfs2 tsmdbbkpvg 7331840M
chlv -U root -G system -P 660 tsmdbbkp01lv
mklv -e x -y tsmdbbkp02lv -t jfs2 tsmdbbkpvg 7331840M
chlv -U root -G system -P 660 tsmdbbkp02lv
mklv -e x -y tsmdbbkp03lv -t jfs2 tsmdbbkpvg 7331840M
chlv -U root -G system -P 660 tsmdbbkp03lv
mklv -e x -y tsmdbbkp04lv -t jfs2 tsmdbbkpvg 7331840M
chlv -U root -G system -P 660 tsmdbbkp04lv
mklv -e x -y tsmarchloglv -t jfs2 tsmarchlogvg 2093056M
chlv -U root -G system -P 660 tsmarchloglv
mklv -e x -y tsmarchlog2lv -t jfs2 tsmarchlogvg 2093056M
chlv -U root -G system -P 660 tsmarchlog2lv
mklv -e x -y tsmactloglv -t jfs2 tsmactlogvg 306688M
chlv -U root -G system -P 660 tsmactloglv
mklv -e x -y caalv_private3 -t boot caavg_private 256M
chlv -U root -G system -P 660 caalv_private3
mklv -e x -y caalv_private1 -t boot caavg_private 64M
chlv -U root -G system -P 660 caalv_private1
mklv -e x -y caalv_private2 -t boot caavg_private 64M
chlv -U root -G system -P 660 caalv_private2
mklv -e x -y powerha_crlv -t boot caavg_private 64M
chlv -U root -G system -P 660 powerha_crlv
if [ ! -d /tsmdb ] ; 
then
     mkdir /tsmdb
     chmod 755 /tsmdb
     chown tsmadmin:tsmsrvrs /tsmdb
fi
if [ ! -d /tsmdbbkp ] ; 
then
     mkdir /tsmdbbkp
     chmod 755 /tsmdbbkp
     chown tsmadmin:tsmsrvrs /tsmdbbkp
fi
if [ ! -d /tsmfs01 ] ; 
then
     mkdir /tsmfs01
     chmod 755 /tsmfs01
     chown tsmadmin:tsmsrvrs /tsmfs01
fi
if [ ! -d /tsmfs02 ] ; 
then
     mkdir /tsmfs02
     chmod 755 /tsmfs02
     chown tsmadmin:tsmsrvrs /tsmfs02
fi
crfs -v jfs2 -m /tsmapps -d tsmappslv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmapps 2>/dev/null
crfs -v jfs2 -m /tsmrecovery -d tsmrecoverylv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmrecovery 2>/dev/null
crfs -v jfs2 -m /tsmhome -d tsmhomelv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmhome 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs12 -d tsmfs12lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs12 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs13 -d tsmfs13lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs13 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs14 -d tsmfs14lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs14 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs15 -d tsmfs15lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs15 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs16 -d tsmfs16lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs16 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs17 -d tsmfs17lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs17 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs18 -d tsmfs18lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs18 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs19 -d tsmfs19lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs19 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs20 -d tsmfs20lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs20 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs21 -d tsmfs21lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs21 2>/dev/null
crfs -v jfs2 -m /tsmfs02/tsmfs22 -d tsmfs22lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs02/tsmfs22 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs01 -d tsmfs01lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs01 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs02 -d tsmfs02lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs02 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs03 -d tsmfs03lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs03 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs04 -d tsmfs04lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs04 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs05 -d tsmfs05lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs05 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs06 -d tsmfs06lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs06 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs07 -d tsmfs07lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs07 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs08 -d tsmfs08lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs08 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs09 -d tsmfs09lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs09 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs10 -d tsmfs10lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs10 2>/dev/null
crfs -v jfs2 -m /tsmfs01/tsmfs11 -d tsmfs11lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmfs01/tsmfs11 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb01 -d tsmdb01lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb01 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb02 -d tsmdb02lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb02 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb03 -d tsmdb03lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb03 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb04 -d tsmdb04lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb04 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb05 -d tsmdb05lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb05 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb06 -d tsmdb06lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb06 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb07 -d tsmdb07lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb07 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb08 -d tsmdb08lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb08 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb09 -d tsmdb09lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb09 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb10 -d tsmdb10lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb10 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb11 -d tsmdb11lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb11 2>/dev/null
crfs -v jfs2 -m /tsmdb/tsmdb12 -d tsmdb12lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdb/tsmdb12 2>/dev/null
crfs -v jfs2 -m /tsmdbbkp/tsmdbbkp01 -d tsmdbbkp01lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdbbkp/tsmdbbkp01 2>/dev/null
crfs -v jfs2 -m /tsmdbbkp/tsmdbbkp02 -d tsmdbbkp02lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdbbkp/tsmdbbkp02 2>/dev/null
crfs -v jfs2 -m /tsmdbbkp/tsmdbbkp03 -d tsmdbbkp03lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdbbkp/tsmdbbkp03 2>/dev/null
crfs -v jfs2 -m /tsmdbbkp/tsmdbbkp04 -d tsmdbbkp04lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmdbbkp/tsmdbbkp04 2>/dev/null
crfs -v jfs2 -m /tsmarchlog -d tsmarchloglv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmarchlog 2>/dev/null
crfs -v jfs2 -m /tsmarchlog2 -d tsmarchlog2lv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmarchlog2 2>/dev/null
crfs -v jfs2 -m /tsmactlog -d tsmactloglv -a logname=INLINE -A no
yes -a options=rbrw,noatime,rw
mount /tsmactlog 2>/dev/null
chmod 755 /tsmactlog
chown tsmadmin:tsmsrvrs /tsmactlog
chmod 755 /tsmapps
chown root:system /tsmapps
chmod 755 /tsmarchlog
chown tsmadmin:tsmsrvrs /tsmarchlog
chmod 755 /tsmarchlog2
chown tsmadmin:tsmsrvrs /tsmarchlog2
chmod 755 /tsmdb/tsmdb01
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb01
chmod 755 /tsmdb/tsmdb02
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb02
chmod 755 /tsmdb/tsmdb03
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb03
chmod 755 /tsmdb/tsmdb04
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb04
chmod 755 /tsmdb/tsmdb05
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb05
chmod 755 /tsmdb/tsmdb06
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb06
chmod 755 /tsmdb/tsmdb07
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb07
chmod 755 /tsmdb/tsmdb08
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb08
chmod 755 /tsmdb/tsmdb09
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb09
chmod 755 /tsmdb/tsmdb10
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb10
chmod 755 /tsmdb/tsmdb11
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb11
chmod 755 /tsmdb/tsmdb12
chown tsmadmin:tsmsrvrs /tsmdb/tsmdb12
chmod 755 /tsmdbbkp/tsmdbbkp01
chown tsmadmin:tsmsrvrs /tsmdbbkp/tsmdbbkp01
chmod 755 /tsmdbbkp/tsmdbbkp02
chown tsmadmin:tsmsrvrs /tsmdbbkp/tsmdbbkp02
chmod 755 /tsmdbbkp/tsmdbbkp03
chown tsmadmin:tsmsrvrs /tsmdbbkp/tsmdbbkp03
chmod 755 /tsmdbbkp/tsmdbbkp04
chown tsmadmin:tsmsrvrs /tsmdbbkp/tsmdbbkp04
chmod 755 /tsmfs01/tsmfs01
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs01
chmod 755 /tsmfs01/tsmfs02
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs02
chmod 755 /tsmfs01/tsmfs03
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs03
chmod 755 /tsmfs01/tsmfs04
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs04
chmod 755 /tsmfs01/tsmfs05
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs05
chmod 755 /tsmfs01/tsmfs06
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs06
chmod 755 /tsmfs01/tsmfs07
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs07
chmod 755 /tsmfs01/tsmfs08
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs08
chmod 755 /tsmfs01/tsmfs09
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs09
chmod 755 /tsmfs01/tsmfs10
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs10
chmod 755 /tsmfs01/tsmfs11
chown tsmadmin:tsmsrvrs /tsmfs01/tsmfs11
chmod 755 /tsmfs02/tsmfs12
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs12
chmod 755 /tsmfs02/tsmfs13
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs13
chmod 755 /tsmfs02/tsmfs14
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs14
chmod 755 /tsmfs02/tsmfs15
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs15
chmod 755 /tsmfs02/tsmfs16
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs16
chmod 755 /tsmfs02/tsmfs17
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs17
chmod 755 /tsmfs02/tsmfs18
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs18
chmod 755 /tsmfs02/tsmfs19
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs19
chmod 755 /tsmfs02/tsmfs20
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs20
chmod 755 /tsmfs02/tsmfs21
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs21
chmod 755 /tsmfs02/tsmfs22
chown tsmadmin:tsmsrvrs /tsmfs02/tsmfs22
chmod 755 /tsmhome
chown root:system /tsmhome
chmod 755 /tsmrecovery
chown tsmadmin:tsmsrvrs /tsmrecovery

2017-05-26 07:40:57: Check checklvfscreate.ksh completed successfully: returncode 0
2017-05-26 07:40:57: Runtime: 8 second(s)
2017-05-26 07:40:57: 53% complete - 104 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:57: Running check script 121 of 224: checklvmcfg.ksh

Description:
------------

Displays the most recent LVM commands run on the system.

To display the list of most recent LVM commands, run:

# /usr/bin/alog -o -t lvmcfg | grep -v -E "workdir|exited|tellclvmd"

Output:
------------

[S 9568580 16450180 05/24/17-08:57:16:639 mklv.sh 676] mklv -yexportlv -tjfs2 -u2 -c2 rootvg 20 hdisk0 
hdisk1 
[S 16450210 18088344 05/24/17-08:58:33:311 chlv.sh 541] chlv -L /export exportlv 
[S 8716794 13500926 05/26/17-06:31:27:156 lvmo.c 950] /usr/sbin/lvmo -v caavg_private -a 
[S 12125016 13500926 05/26/17-06:31:27:159 lvmo.c 950] /usr/sbin/lvmo -v rootvg -a 
[S 12387018 13500926 05/26/17-06:31:27:162 lvmo.c 950] /usr/sbin/lvmo -v tsmactlogvg -a 
[S 8716796 13500926 05/26/17-06:31:27:166 lvmo.c 950] /usr/sbin/lvmo -v tsmarchlogvg -a 
[S 8716798 13500926 05/26/17-06:31:27:169 lvmo.c 950] /usr/sbin/lvmo -v tsmdbbkpvg -a 
[S 12387020 13500926 05/26/17-06:31:27:172 lvmo.c 950] /usr/sbin/lvmo -v tsmdbvg -a 
[S 12125018 13500926 05/26/17-06:31:27:175 lvmo.c 950] /usr/sbin/lvmo -v tsmfs01vg -a 
[S 12387022 13500926 05/26/17-06:31:27:178 lvmo.c 950] /usr/sbin/lvmo -v tsmfs02vg -a 
[S 12387024 13500926 05/26/17-06:31:27:181 lvmo.c 950] /usr/sbin/lvmo -v tsmhomevg -a 
[S 8716544 13500926 05/26/17-06:31:27:184 lvmo.c 950] /usr/sbin/lvmo -v tsmrecoveryvg -a 
[S 16974776 11272496 05/26/17-06:35:16:846 lvmo.c 950] /usr/sbin/lvmo -v caavg_private -a 
[S 16974778 11272496 05/26/17-06:35:16:849 lvmo.c 950] /usr/sbin/lvmo -v rootvg -a 
[S 16974780 11272496 05/26/17-06:35:16:852 lvmo.c 950] /usr/sbin/lvmo -v tsmactlogvg -a 
[S 16974782 11272496 05/26/17-06:35:16:856 lvmo.c 950] /usr/sbin/lvmo -v tsmarchlogvg -a 
[S 19923016 11272496 05/26/17-06:35:16:859 lvmo.c 950] /usr/sbin/lvmo -v tsmdbbkpvg -a 
[S 16974784 11272496 05/26/17-06:35:16:862 lvmo.c 950] /usr/sbin/lvmo -v tsmdbvg -a 
[S 16974786 11272496 05/26/17-06:35:16:865 lvmo.c 950] /usr/sbin/lvmo -v tsmfs01vg -a 
[S 19923018 11272496 05/26/17-06:35:16:868 lvmo.c 950] /usr/sbin/lvmo -v tsmfs02vg -a 
[S 13500842 11272496 05/26/17-06:35:16:872 lvmo.c 950] /usr/sbin/lvmo -v tsmhomevg -a 
[S 16974788 11272496 05/26/17-06:35:16:877 lvmo.c 950] /usr/sbin/lvmo -v tsmrecoveryvg -a 

2017-05-26 07:40:57: Check checklvmcfg.ksh completed successfully: returncode 0
2017-05-26 07:40:57: Runtime: 0 second(s)
2017-05-26 07:40:57: 54% complete - 103 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:57: Running check script 122 of 224: checklvmoa.ksh

Description:
------------

Shows the pbuf tunable parameters for each online volume group.

To display this information, for example for the rootvg volume group, run:

# /usr/sbin/lvmo -v rootvg -a

Output:
------------

vgname = caavg_private
pv_pbuf_count = 512
total_vg_pbufs = 512
max_vg_pbufs = 16384
pervg_blocked_io_count = 0
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = rootvg
pv_pbuf_count = 512
total_vg_pbufs = 1024
max_vg_pbufs = 16384
pervg_blocked_io_count = 36
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = tsmactlogvg
pv_pbuf_count = 512
total_vg_pbufs = 512
max_vg_pbufs = 524288
pervg_blocked_io_count = 0
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = tsmarchlogvg
pv_pbuf_count = 512
total_vg_pbufs = 1024
max_vg_pbufs = 524288
pervg_blocked_io_count = 925452
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = tsmdbbkpvg
pv_pbuf_count = 512
total_vg_pbufs = 2048
max_vg_pbufs = 524288
pervg_blocked_io_count = 13869
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = tsmdbvg
pv_pbuf_count = 512
total_vg_pbufs = 6144
max_vg_pbufs = 524288
pervg_blocked_io_count = 0
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = tsmfs01vg
pv_pbuf_count = 512
total_vg_pbufs = 5632
max_vg_pbufs = 524288
pervg_blocked_io_count = 0
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = tsmfs02vg
pv_pbuf_count = 512
total_vg_pbufs = 5632
max_vg_pbufs = 524288
pervg_blocked_io_count = 217
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = tsmhomevg
pv_pbuf_count = 512
total_vg_pbufs = 512
max_vg_pbufs = 524288
pervg_blocked_io_count = 0
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

vgname = tsmrecoveryvg
pv_pbuf_count = 512
total_vg_pbufs = 1024
max_vg_pbufs = 524288
pervg_blocked_io_count = 0
pv_min_pbuf = 512
max_vg_pbuf_count = 0
global_blocked_io_count = 939574
aio_cache_pbuf_count = 0
workQ_size = 256

2017-05-26 07:40:57: Check checklvmoa.ksh completed successfully: returncode 0
2017-05-26 07:40:57: Runtime: 0 second(s)
2017-05-26 07:40:57: 54% complete - 102 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:57: Running check script 123 of 224: checkmachineid.ksh

Description:
------------

Show the machine id (uname -m) of the AIX server.

The machine ID number contains 12 characters in the following digit format: xxyyyyyymmss. The xx 
positions indicate the system and is always 00. The yyyyyy positions contain the unique ID number for 
the entire system. The mm position represents the model ID. The ss position is the submodel number and 
is always 00. The model ID describes the ID of the CPU Planar, not the model of the system as a whole. 
Most machines share a common model ID of 4C.

Output:
------------

00FAB0773D00

2017-05-26 07:40:57: Check checkmachineid.ksh completed successfully: returncode 0
2017-05-26 07:40:57: Runtime: 0 second(s)
2017-05-26 07:40:57: 54% complete - 101 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:57: Running check script 124 of 224: checkmajor.ksh

Description:
------------

List the available major numbers, and list the major numbers in use for all the volume groups on the 
system.

Output:
------------

Major numbers in use for volume groups:

rootvg: 10
tsmdbvg: 45
tsmactlogvg: 46
tsmarchlogvg: 47
tsmrecoveryvg: 48
tsmdbbkpvg: 49
tsmfs01vg: 50
tsmfs02vg: 51
caavg_private: 44
tsmhomevg: 52

Available major numbers (lvlstmajor):

54...

2017-05-26 07:40:57: Check checkmajor.ksh completed successfully: returncode 0
2017-05-26 07:40:57: Runtime: 0 second(s)
2017-05-26 07:40:57: 55% complete - 100 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:57: Running check script 125 of 224: checkmanagediskdrivers.ksh

Description:
------------

Display the output of the manage_disk_drivers command to list all the storage families and their 
supported drivers.

The command run is:

# /usr/bin/manage_disk_drivers -l

This command displays information about storage families and the driver that manages each family.

Output:
------------

Device              Present Driver        Driver Options     
2810XIV             AIX_AAPCM             AIX_AAPCM,AIX_non_MPIO
DS4100              AIX_APPCM             AIX_APPCM,AIX_fcparray
DS4200              AIX_APPCM             AIX_APPCM,AIX_fcparray
DS4300              AIX_APPCM             AIX_APPCM,AIX_fcparray
DS4500              AIX_APPCM             AIX_APPCM,AIX_fcparray
DS4700              AIX_APPCM             AIX_APPCM,AIX_fcparray
DS4800              AIX_APPCM             AIX_APPCM,AIX_fcparray
DS3950              AIX_APPCM             AIX_APPCM
DS5020              AIX_APPCM             AIX_APPCM
DCS3700             AIX_APPCM             AIX_APPCM
DS5100/DS5300       AIX_APPCM             AIX_APPCM
DS3500              AIX_APPCM             AIX_APPCM
XIVCTRL             MPIO_XIVCTRL          MPIO_XIVCTRL,nonMPIO_XIVCTRL
2107DS8K            NO_OVERRIDE           NO_OVERRIDE,AIX_AAPCM,AIX_non_MPIO
IBMFlash            NO_OVERRIDE           NO_OVERRIDE,AIX_AAPCM,AIX_non_MPIO
IBMSVC              NO_OVERRIDE           NO_OVERRIDE,AIX_AAPCM,AIX_non_MPIO

2017-05-26 07:40:57: Check checkmanagediskdrivers.ksh completed successfully: returncode 0
2017-05-26 07:40:57: Runtime: 0 second(s)
2017-05-26 07:40:57: 55% complete - 99 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:40:57: Running check script 126 of 224: checkmemoryactive.ksh

Description:
------------

Check the active memory size.

This will show you how much memory the system is really using. 

Please note that AIX is designed to use as much memory as possible for caching data, in order to 
improve performance. Just looking at the available memory on the system, is NOT a good indicator of 
memory use.

Output:
------------

124085 MB

2017-05-26 07:41:00: Check checkmemoryactive.ksh completed successfully: returncode 0
2017-05-26 07:41:00: Runtime: 3 second(s)
2017-05-26 07:41:00: 56% complete - 98 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:00: Running check script 127 of 224: checkmemorypools.ksh

Description:
------------

Displays the number of memory pools.


Output:
------------

24

2017-05-26 07:41:00: Check checkmemorypools.ksh completed successfully: returncode 0
2017-05-26 07:41:00: Runtime: 0 second(s)
2017-05-26 07:41:00: 56% complete - 97 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:00: Running check script 128 of 224: checkmemorysize.ksh

Description:
------------

Displays the size of memory in megabytes.

Output:
------------

255744

2017-05-26 07:41:00: Check checkmemorysize.ksh completed successfully: returncode 0
2017-05-26 07:41:00: Runtime: 0 second(s)
2017-05-26 07:41:00: 57% complete - 96 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:00: Running check script 129 of 224: checkmodelname.ksh

Description:
------------

Checks the model name of the server.

Output:
------------

8286-42A

2017-05-26 07:41:00: Check checkmodelname.ksh completed successfully: returncode 0
2017-05-26 07:41:00: Runtime: 0 second(s)
2017-05-26 07:41:00: 57% complete - 95 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:00: Running check script 130 of 224: checkmount.ksh

Description:
------------

Display the output of the mount command, which shows all the mounted file systems.

Output:
------------

  node       mounted        mounted over    vfs       date        options      
-------- ---------------  ---------------  ------ ------------ --------------- 
         /dev/hd4         /                jfs2   May 15 11:59 rw,log=/dev/hd8 
         /dev/hd2         /usr             jfs2   May 15 11:59 rw,log=/dev/hd8 
         /dev/hd9var      /var             jfs2   May 15 11:59 rw,log=/dev/hd8 
         /dev/hd3         /tmp             jfs2   May 15 11:59 rw,log=/dev/hd8 
         /dev/hd1         /home            jfs2   May 15 12:00 rw,log=/dev/hd8 
         /dev/hd11admin   /admin           jfs2   May 15 12:00 rw,log=/dev/hd8 
         /proc            /proc            procfs May 15 12:00 rw              
         /dev/hd10opt     /opt             jfs2   May 15 12:00 rw,log=/dev/hd8 
         /dev/livedump    /var/adm/ras/livedump jfs2   May 15 12:00 rw,log=/dev/hd8 
         /dev/mksysblv    /mksysb          jfs2   May 15 12:00 rw,noatime,log=INLINE
         /aha             /aha             ahafs  May 15 12:00 rw              
         /dev/tsmactloglv /tsmactlog       jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmappslv   /tsmapps         jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmarchloglv /tsmarchlog      jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmarchlog2lv /tsmarchlog2     jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb01lv   /tsmdb/tsmdb01   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb02lv   /tsmdb/tsmdb02   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb03lv   /tsmdb/tsmdb03   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb04lv   /tsmdb/tsmdb04   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb05lv   /tsmdb/tsmdb05   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb06lv   /tsmdb/tsmdb06   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb07lv   /tsmdb/tsmdb07   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb08lv   /tsmdb/tsmdb08   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb09lv   /tsmdb/tsmdb09   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb10lv   /tsmdb/tsmdb10   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb11lv   /tsmdb/tsmdb11   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdb12lv   /tsmdb/tsmdb12   jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdbbkp01lv /tsmdbbkp/tsmdbbkp01 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdbbkp02lv /tsmdbbkp/tsmdbbkp02 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdbbkp03lv /tsmdbbkp/tsmdbbkp03 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmdbbkp04lv /tsmdbbkp/tsmdbbkp04 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs01lv   /tsmfs01/tsmfs01 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs02lv   /tsmfs01/tsmfs02 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs03lv   /tsmfs01/tsmfs03 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs04lv   /tsmfs01/tsmfs04 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs05lv   /tsmfs01/tsmfs05 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs06lv   /tsmfs01/tsmfs06 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs07lv   /tsmfs01/tsmfs07 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs08lv   /tsmfs01/tsmfs08 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs09lv   /tsmfs01/tsmfs09 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs10lv   /tsmfs01/tsmfs10 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs11lv   /tsmfs01/tsmfs11 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs12lv   /tsmfs02/tsmfs12 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs13lv   /tsmfs02/tsmfs13 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs14lv   /tsmfs02/tsmfs14 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs15lv   /tsmfs02/tsmfs15 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs16lv   /tsmfs02/tsmfs16 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs17lv   /tsmfs02/tsmfs17 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs18lv   /tsmfs02/tsmfs18 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs19lv   /tsmfs02/tsmfs19 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs20lv   /tsmfs02/tsmfs20 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs21lv   /tsmfs02/tsmfs21 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmfs22lv   /tsmfs02/tsmfs22 jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmhomelv   /tsmhome         jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/tsmrecoverylv /tsmrecovery     jfs2   May 15 12:14 rw,rbw,rbr,noatime,log=INLINE
         /dev/exportlv    /export          jfs2   May 24 08:58 rw,noatime,log=INLINE

2017-05-26 07:41:00: Check checkmount.ksh completed successfully: returncode 0
2017-05-26 07:41:00: Runtime: 0 second(s)
2017-05-26 07:41:00: 58% complete - 94 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:00: Running check script 131 of 224: checkmpiogetconfig.ksh

Description:
------------

Display subsystem specific information for the DS3k/DS4k/DS5k disks (if any).

2017-05-26 07:41:00: Check checkmpiogetconfig.ksh completed successfully: returncode 0
2017-05-26 07:41:00: Runtime: 0 second(s)
2017-05-26 07:41:00: 58% complete - 93 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:00: Running check script 132 of 224: checkmqini.ksh

Description:
------------

Displays the contents of the WebSphere MQ system wide ini file.

The /var/mqm/mqs.ini file is a configuration file for WebSphere MQ and defines various system wide 
settings, along with any Queue Managers.


2017-05-26 07:41:01: Check checkmqini.ksh completed successfully: returncode 0
2017-05-26 07:41:01: Runtime: 0 second(s)
2017-05-26 07:41:01: 58% complete - 92 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:01: Running check script 133 of 224: checkmqqueuemanager.ksh

Description:
------------

Displays the status of the WebSphere MQ queue manager, if installed.

To display the status of the WebSphere MQ queue manager, run the following command as user mqm:

# /usr/mqm/bin/dspmq -o status -o def

The /usr/mqm/bin/dspmq command displays the status of all the queue managers defined in the 
/var/mqm/mqs.ini file.

2017-05-26 07:41:01: Check checkmqqueuemanager.ksh completed successfully: returncode 0
2017-05-26 07:41:01: Runtime: 0 second(s)
2017-05-26 07:41:01: 59% complete - 91 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:01: Running check script 134 of 224: checkmqversion.ksh

Description:
------------

Checks the level of WebSphere MQ installed.

2017-05-26 07:41:01: Check checkmqversion.ksh completed successfully: returncode 0
2017-05-26 07:41:01: Runtime: 0 second(s)
2017-05-26 07:41:01: 59% complete - 90 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:01: Running check script 135 of 224: checkmultiprocessor.ksh

Description:
------------

Checks if the system is multi-processor capable.

Output:
------------

System is multi-processor capable.

2017-05-26 07:41:01: Check checkmultiprocessor.ksh completed successfully: returncode 0
2017-05-26 07:41:01: Runtime: 0 second(s)
2017-05-26 07:41:01: 60% complete - 89 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:01: Running check script 136 of 224: checknamedconf.ksh

Description:
------------

Check the contents of /etc/named.conf, if it exists.

2017-05-26 07:41:01: Check checknamedconf.ksh completed successfully: returncode 0
2017-05-26 07:41:01: Runtime: 0 second(s)
2017-05-26 07:41:01: 60% complete - 88 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:01: Running check script 137 of 224: checknameservers.ksh

Description:
------------

Shows the contents of /etc/resolv.conf.

Output:
------------

nameserver	192.18.42.52
nameserver 	192.18.42.53
search	unixhealthcheck.com

2017-05-26 07:41:01: Check checknameservers.ksh completed successfully: returncode 0
2017-05-26 07:41:01: Runtime: 0 second(s)
2017-05-26 07:41:01: 61% complete - 87 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:01: Running check script 138 of 224: checknetstat.ksh

Description:
------------

Shows the output of netstat -rn and netstat -i. This will display the routing table and the network 
interfaces.

Output:
------------

netstat -rn

Routing tables
Destination        Gateway           Flags   Refs     Use  If   Exp  Groups

Route Tree for Protocol Family 2 (Internet):
default            192.18.42.1       UG        1 2956322448 en8      -      -   
127/8              127.0.0.1         U         9 2069753949 lo0      -      -   
192.18.42.0        192.18.42.45      UHSb      0         0 en8      -      -   =>
192.18.42/24       192.18.42.45      U         7 559528111 en8      -      -   
192.18.42.43       127.0.0.1         UGHS      1    133636 lo0      -      -   
192.18.42.45       127.0.0.1         UGHS      2    132117 lo0      -      -   
192.18.42.255      192.18.42.45      UHSb      0         4 en8      -      -   

Route Tree for Protocol Family 24 (Internet v6):
::1%1              ::1%1             UH        0      6783 lo0      -      -   

netstat -i

Name  Mtu   Network     Address            Ipkts Ierrs    Opkts Oerrs  Coll
en8   1500  link#2      98.be.94.68.95.98 3055541944     0 3506952299     0     0
en8   1500  192.18.42   tsm0000         3055541944     0 3506952299     0     0
en8   1500  192.18.42   tsm0001         3055541944     0 3506952299     0     0
lo0   16896 link#1                       2069863260     0 2069868821     0     0
lo0   16896 127         loopback         2069863260     0 2069868821     0     0
lo0   16896 ::1%1                        2069863260     0 2069868821     0     0

netstat -s

icmp:
	43 calls to icmp_error
	0 errors not generated because old message was icmp
	Output histogram:
		echo reply: 156279
		destination unreachable: 43
		echo: 7603
	0 messages with bad code fields
	0 messages < minimum length
	0 bad checksums
	0 messages with bad length
	Input histogram:
		echo reply: 91882
		destination unreachable: 41
		echo: 156279
	156279 message responses generated
igmp:
	0 messages received
	0 messages received with too few bytes
	0 messages received with bad checksum
	0 membership queries received
	0 membership queries received with invalid field(s)
	0 membership reports received
	0 membership reports received with invalid field(s)
	0 membership reports received for groups to which we belong
	4 membership reports sent
tcp:
	18471852375 packets sent
		4781109637 data packets (78380255813336 bytes)
		352328 data packets (1723764320 bytes) retransmitted
		7766932813 ack-only packets (3043597 delayed)
		0 URG only packets
		1 window probe packet
		5923163334 window update packets
		607466 control packets
		10748092 large send
		205835120924 byte sent using largesend
		65160 byte is the biggest largesend
	22055030196 packets received
		4793430880 acks (for 78380258900541 bytes)
		1208549 duplicate acks
		0 acks for unsent data
		15990659882 packets (178560154446296 bytes) received in-sequence
		29445434 completely duplicate packets (121471854812 bytes)
		1277683 old duplicate packets
		4207195 packets with some dup. data (17743637071 bytes duped)
		113729024 out-of-order packets (467022412471 bytes)
		18 packets (18 bytes) of data after window
		18 window probes
		1127480566 window update packets
		1760 packets received after close
		0 packets with bad hardware assisted checksum
		0 discarded for bad checksums
		0 discarded for bad header offset fields
		0 discarded because packet too short
		323 discarded by listeners
		0 discarded due to listener's queue full
		15297696 ack packet headers correctly predicted
		14177054251 data packet headers correctly predicted
	107911 connection requests
	44471 connection accepts
	61855 connections established (including accepts)
	152450 connections closed (including 1339 drops)
	0 connections with ECN capability
	0 times responded to ECN
	22 embryonic connections dropped
	4778383109 segments updated rtt (of 2045770544 attempts)
	0 segments with congestion window reduced bit set
	0 segments with congestion experienced bit set
	0 resends due to path MTU discovery
	45257 path MTU discovery terminations due to retransmits
	179097 retransmit timeouts
		0 connections dropped by rexmit timeout
	120162 fast retransmits
		60588 when congestion window less than 4 segments
	188420 newreno retransmits
	0 times avoided false fast retransmits
	900 persist timeouts
		0 connections dropped due to persist timeout
	13 keepalive timeouts
		10 keepalive probes sent
		3 connections dropped by keepalive
	0 times SACK blocks array is extended
	0 times SACK holes array is extended
	0 packets dropped due to memory allocation failure
	0 connections in timewait reused
	0 delayed ACKs for SYN
	0 delayed ACKs for FIN
	0 send_and_disconnects
	0 spliced connections
	0 spliced connections closed
	0 spliced connections reset
	0 spliced connections timeout
	0 spliced connections persist timeout
	0 spliced connections keepalive timeout
	0 TCP checksum offload disabled during retransmit
	7309514 Connections dropped due to bad ACKs
	16 Connections dropped due to duplicate SYN packets
	0 fastpath loopback connections
	0 fastpath loopback sent packets (0 bytes)
	0 fastpath loopback received packets (0 bytes)
udp:
	285916 datagrams received
	0 incomplete headers
	0 bad data length fields
	0 bad checksums
	4457 dropped due to no socket
	1044 broadcast/multicast datagrams dropped due to no socket
	0 socket buffer overflows
	280415 delivered
	353716 datagrams output
ip:
	829199000 total packets received
	0 bad header checksums
	0 with size smaller than minimum
	0 with data size < data length
	0 with header length < data size
	0 with data length < header length
	0 with bad options
	0 with incorrect version number
	14 fragments received
	0 fragments dropped (dup or out of space)
	0 fragments dropped after timeout
	7 packets reassembled ok
	580724214 packets for this host
	41 packets for unknown/unsupported protocol
	0 packets forwarded
	248403232 packets not forwardable
	0 redirects sent
	1292508264 packets sent from this host
	0 packets sent with fabricated ip header
	0 output packets dropped due to no bufs, etc.
	0 output packets discarded due to no route
	219 output datagrams fragmented
	996 fragments created
	0 datagrams that can't be fragmented
	0 IP Multicast packets dropped due to no receiver
	0 successful path MTU discovery cycles
	0 path MTU rediscovery cycles attempted
	0 path MTU discovery no-response estimates
	0 path MTU discovery response timeouts
	0 path MTU discovery decreases detected
	0 path MTU discovery packets sent
	0 path MTU discovery memory allocation failures
	0 ipintrq overflows
	0 with illegal source
	0 packets processed by threads
	0 packets dropped by threads
	48 packets dropped due to the full socket receive buffer
	0 dead gateway detection packets sent
	0 dead gateway detection packet allocation failures
	0 dead gateway detection gateway allocation failures
	0 incoming packets dropped due to MLS filters
	0 packets not sent due to MLS filters

ipv6:
	6783 total packets received
	Input histogram:
		UDP: 4414
		ICMP v6: 2369
	0 with size smaller than minimum
	0 with data size < data length
	0 with incorrect version number
	0 with illegal source
	0 input packets without enough memory
	0 fragments received
	0 fragments dropped (dup or out of space)
	0 fragments dropped after timeout
	0 packets reassembled ok
	6783 packets for this host
	0 packets for unknown/unsupported protocol
	0 packets forwarded
	0 packets not forwardable
	0 too big packets not forwarded
	6783 packets sent from this host
	0 packets sent with fabricated ipv6 header
	0 output packets dropped due to no bufs, etc.
	0 output packets without enough memory
	0 output packets discarded due to no route
	0 output datagrams fragmented
	0 fragments created
	0 packets dropped due to the full socket receive buffer
	0 packets not delivered due to bad raw IPv6 checksum
	0 incoming packets dropped due to MLS filters
	0 packets not sent due to MLS filters
icmpv6:
	4414 calls to icmp6_error
	0 errors not generated because old message was icmpv6
	Output histogram:
		unreachable: 2369
		packets too big: 0
		time exceeded: 0
		parameter problems: 0
		redirects: 0
		echo requests: 0
		echo replies: 0
		group queries: 0
		group reports: 0
		group terminations: 0
		router solicitations: 0
		router advertisements: 0
		neighbor solicitations: 0
		neighbor advertisements: 0
	0 messages with bad code fields
	0 messages < minimum length
	0 bad checksums
	0 messages with bad length
	Input histogram:
		unreachable: 2369
		packets too big: 0
		time exceeded: 0
		parameter problems: 0
		echo requests: 0
		echo replies: 0
		group queries: 0
			bad group queries: 0
		group reports: 0
			bad group reports: 0
			our groups' reports: 0
		group terminations: 0
		bad group terminations: 0
		router solicitations: 0
		bad router solicitations: 0
		router advertisements: 0
		bad router advertisements: 0
		neighbor solicitations: 0
		bad neighbor solicitations: 0
		neighbor advertisements: 0
		bad neighbor advertisements: 0
		redirects: 0
		bad redirects: 0
		mobility calls when not started: 0
		home agent address discovery requests: 0
		bad home agent address discovery requests: 0
		home agent address discovery replies: 0
		bad home agent address discovery replies: 0
		prefix solicitations: 0
		bad prefix solicitations: 0
		prefix advertisements: 0
		bad prefix advertisements: 0
	0 message responses generated

ifconfig -a

en8: 
flags=1e084863,118c0<UP,BROADCAST,NOTRAILERS,RUNNING,SIMPLEX,MULTICAST,GROUPRT,64BIT,CHECKSUM_OFFLOAD(AC
TIVE),LARGESEND,CHAIN>
	inet 192.18.42.45 netmask 0xffffff00 broadcast 192.18.42.255
	inet 192.18.42.43 netmask 0xffffff00 broadcast 192.18.42.255
	 tcp_sendspace 262144 tcp_recvspace 262144 rfc1323 1
lo0: flags=e08084b,c0<UP,BROADCAST,LOOPBACK,RUNNING,SIMPLEX,MULTICAST,GROUPRT,64BIT,LARGESEND,CHAIN>
	inet 127.0.0.1 netmask 0xff000000 broadcast 127.255.255.255
	inet6 ::1%1/0
	 tcp_sendspace 131072 tcp_recvspace 131072 rfc1323 1

2017-05-26 07:41:01: Check checknetstat.ksh completed successfully: returncode 0
2017-05-26 07:41:01: Runtime: 0 second(s)
2017-05-26 07:41:01: 61% complete - 86 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:02: Running check script 139 of 224: checknfsconfig.ksh

Description:
------------

Shows the NFS configuration (the exported and mounted NFS file systems).

2017-05-26 07:41:02: Check checknfsconfig.ksh completed successfully: returncode 0
2017-05-26 07:41:02: Runtime: 0 second(s)
2017-05-26 07:41:02: 62% complete - 85 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:02: Running check script 140 of 224: checknfsoa.ksh

Description:
------------

List the NFS options by running:

# nfso -a

Output:
------------

           client_delegation = 1
           nfs_max_read_size = 65536
          nfs_max_write_size = 65536
                 nfs_rfc1323 = 1
   nfs_securenfs_authtimeout = 0
    nfs_server_base_priority = 0
           nfs_server_clread = 1
      nfs_use_reserved_ports = 0
   nfs_v3_server_readdirplus = 1
    nfs_v4_fail_over_timeout = 0
                   portcheck = 0
           server_delegation = 1
             utf8_validation = 1
      nfs_server_close_delay = 0
                nfs_hang_log = 6

2017-05-26 07:41:02: Check checknfsoa.ksh completed successfully: returncode 0
2017-05-26 07:41:02: Runtime: 0 second(s)
2017-05-26 07:41:02: 62% complete - 84 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:02: Running check script 141 of 224: checknfsstat.ksh

Description:
------------

Shows the output of nfsstat, which shows the NFS statistics.

Output:
------------


Server rpc:
Connection oriented
calls      badcalls   nullrecv   badlen     xdrcall    dupchecks  dupreqs    
0          0          0          0          0          0          0          
Connectionless
calls      badcalls   nullrecv   badlen     xdrcall    dupchecks  dupreqs    
0          0          0          0          0          0          0          

Server nfs:
calls      badcalls   public_v2  public_v3  
0          0          0          0          
Version 2: (0 calls)
null       getattr    setattr    root       lookup     readlink   read       
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
wrcache    write      create     remove     rename     link       symlink    
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
mkdir      rmdir      readdir    statfs     
0 0%       0 0%       0 0%       0 0%       
Version 3: (0 calls)
null       getattr    setattr    lookup     access     readlink   read       
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
write      create     mkdir      symlink    mknod      remove     rmdir      
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
rename     link       readdir    readdir+   fsstat     fsinfo     pathconf   
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
commit     
0 0%       

Client rpc:
Connection oriented
calls      badcalls   badxids    timeouts   newcreds   badverfs   timers     
0          0          0          0          0          0          0          
nomem      cantconn   interrupts 
0          0          0          
Connectionless
calls      badcalls   retrans    badxids    timeouts   newcreds   badverfs   
23         0          0          0          0          0          0          
timers     nomem      cantsend   
0          0          0          

Client nfs:
calls      badcalls   clgets     cltoomany  
0          0          0          0          
Version 2: (0 calls)
null       getattr    setattr    root       lookup     readlink   read       
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
wrcache    write      create     remove     rename     link       symlink    
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
mkdir      rmdir      readdir    statfs     
0 0%       0 0%       0 0%       0 0%       
Version 3: (0 calls)
null       getattr    setattr    lookup     access     readlink   read       
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
write      create     mkdir      symlink    mknod      remove     rmdir      
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
rename     link       readdir    readdir+   fsstat     fsinfo     pathconf   
0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       0 0%       
commit     
0 0%       

2017-05-26 07:41:02: Check checknfsstat.ksh completed successfully: returncode 0
2017-05-26 07:41:02: Runtime: 0 second(s)
2017-05-26 07:41:02: 62% complete - 83 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:02: Running check script 142 of 224: checkniminfo.ksh

Description:
------------

Display the contents of /etc/niminfo. 

File /etc/niminfo is used by NIM (Network Installation Manager), and is not supposed to be edited 
manually. This check script will display the contents of this file for inventory purposes.

Output:
------------

export NIM_NAME=master
export NIM_CONFIGURATION=master
export NIM_MASTER_PORT=1058
export NIM_REGISTRATION_PORT=1059
export NIM_MASTER_HOSTNAME=tsm0000

2017-05-26 07:41:02: Check checkniminfo.ksh completed successfully: returncode 0
2017-05-26 07:41:02: Runtime: 0 second(s)
2017-05-26 07:41:02: 63% complete - 82 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:02: Running check script 143 of 224: checknoa.ksh

Description:
------------

Lists the network options by running:

# no -a

Output:
------------

                 arpqsize = 1024
               arpt_killc = 20
              arptab_bsiz = 7
                arptab_nb = 149
                bcastping = 0
             bsd_loglevel = 3
      clean_partial_conns = 0
                 delayack = 0
            delayackports = {}
   dgd_flush_cached_route = 0
         dgd_packets_lost = 3
            dgd_ping_time = 5
           dgd_retry_time = 5
       directed_broadcast = 0
                 fasttimo = 200
                    hstcp = 0
        icmp6_errmsg_rate = 10
          icmpaddressmask = 0
            icmptimestamp = 1
ie5_old_multicast_mapping = 0
                   ifsize = 256
           igmpv2_deliver = 0
            init_high_wat = 0
               ip6_defttl = 64
                ip6_prune = 1
            ip6forwarding = 0
       ip6srcrouteforward = 1
       ip_ifdelete_notify = 0
                 ip_nfrag = 200
             ipforwarding = 0
                ipfragttl = 2
        ipignoreredirects = 0
                ipqmaxlen = 100
          ipsendredirects = 1
        ipsrcrouteforward = 1
           ipsrcrouterecv = 0
           ipsrcroutesend = 1
               limited_ss = 0
          llsleep_timeout = 3
                  lo_perf = 1
                lowthresh = 90
                 main_if6 = 0
               main_site6 = 0
                 maxnip6q = 20
                   maxttl = 255
                medthresh = 95
               mpr_policy = 1
              multi_homed = 1
                nbc_limit = 32735232
            nbc_max_cache = 131072
            nbc_min_cache = 1
         nbc_ofile_hashsz = 12841
                 nbc_pseg = 0
           nbc_pseg_limit = 65470464
           ndd_event_name = {all}
        ndd_event_tracing = 0
              ndogthreads = 0
            ndp_mmaxtries = 3
            ndp_umaxtries = 3
                 ndpqsize = 50
                ndpt_down = 3
                ndpt_keep = 120
               ndpt_probe = 5
           ndpt_reachable = 30
             ndpt_retrans = 1
             net_buf_size = {all}
             net_buf_type = {all}
     net_malloc_frag_mask = {0}
        netm_page_promote = 1
           nonlocsrcroute = 0
                 nstrpush = 8
              passive_dgd = 0
         pmtu_default_age = 10
              pmtu_expire = 10
 pmtu_rediscover_interval = 30
              psebufcalls = 20
                 psecache = 1
                psetimers = 20
           rfc1122addrchk = 0
                  rfc1323 = 0
                  rfc2414 = 1
             route_expire = 1
          routerevalidate = 1
     rtentry_lock_complex = 1
                 rto_high = 64
               rto_length = 13
                rto_limit = 7
                  rto_low = 1
                     sack = 0
                   sb_max = 1048576
       send_file_duration = 300
              site6_index = 0
               sockthresh = 85
                  sodebug = 0
              sodebug_env = 0
                somaxconn = 1024
                 strctlsz = 1024
                 strmsgsz = 0
                strthresh = 85
               strturncnt = 15
          subnetsarelocal = 1
       tcp_bad_port_limit = 0
        tcp_cwnd_modified = 0
                  tcp_ecn = 0
       tcp_ephemeral_high = 65535
        tcp_ephemeral_low = 32768
               tcp_fastlo = 0
     tcp_fastlo_crosswpar = 0
             tcp_finwait2 = 1200
           tcp_icmpsecure = 0
          tcp_init_window = 0
    tcp_inpcb_hashtab_siz = 24499
              tcp_keepcnt = 8
             tcp_keepidle = 14400
             tcp_keepinit = 150
            tcp_keepintvl = 150
     tcp_limited_transmit = 1
              tcp_low_rto = 0
             tcp_maxburst = 0
              tcp_mssdflt = 1460
          tcp_nagle_limit = 65535
        tcp_nagleoverride = 0
               tcp_ndebug = 100
              tcp_newreno = 1
           tcp_nodelayack = 1
        tcp_pmtu_discover = 1
            tcp_recvspace = 16384
            tcp_sendspace = 16384
              tcp_syn_rto = 0
            tcp_tcpsecure = 0
             tcp_timewait = 1
                  tcp_ttl = 60
           tcprexmtthresh = 3
             tcptr_enable = 0
                  thewall = 130940928
         timer_wheel_tick = 0
                tn_filter = 1
       udp_bad_port_limit = 0
       udp_ephemeral_high = 65535
        udp_ephemeral_low = 32768
    udp_inpcb_hashtab_siz = 24499
        udp_pmtu_discover = 1
            udp_recv_perf = 0
            udp_recvspace = 42080
            udp_sendspace = 9216
                  udp_ttl = 30
                 udpcksum = 1
           use_sndbufpool = 1

2017-05-26 07:41:02: Check checknoa.ksh completed successfully: returncode 0
2017-05-26 07:41:02: Runtime: 0 second(s)
2017-05-26 07:41:02: 63% complete - 81 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:02: Running check script 144 of 224: checkoratab.ksh

Description:
------------

Outputs the contents of /etc/oratab, if it exists.

2017-05-26 07:41:02: Check checkoratab.ksh completed successfully: returncode 0
2017-05-26 07:41:02: Runtime: 0 second(s)
2017-05-26 07:41:02: 64% complete - 80 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:02: Running check script 145 of 224: checkossvstatus.ksh

Description:
------------

Check the status of NetApp Open Systems SnapVault if the client is installed.

This will list the file systems backed up by OSSV and their status.

2017-05-26 07:41:03: Check checkossvstatus.ksh completed successfully: returncode 0
2017-05-26 07:41:03: Runtime: 0 second(s)
2017-05-26 07:41:03: 64% complete - 79 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:03: Running check script 146 of 224: checkossvstatusl.ksh

Description:
------------

Check the extended status of NetApp Open Systems SnapVault if the client is installed.

This will list a detailed status of file systems backed up by OSSV.

2017-05-26 07:41:03: Check checkossvstatusl.ksh completed successfully: returncode 0
2017-05-26 07:41:03: Runtime: 0 second(s)
2017-05-26 07:41:03: 65% complete - 78 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:03: Running check script 147 of 224: checkossvversion.ksh

Description:
------------

Check the version of NetApp Open Systems SnapVault client if installed.

2017-05-26 07:41:03: Check checkossvversion.ksh completed successfully: returncode 0
2017-05-26 07:41:03: Runtime: 0 second(s)
2017-05-26 07:41:03: 65% complete - 77 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:03: Running check script 148 of 224: checkostype.ksh

Description:
------------

Checks the type of operating system (AIX, Linux, HP-UX, SUN, etcetera). This script runs the uname 
command.

Output:
------------

AIX

2017-05-26 07:41:03: Check checkostype.ksh completed successfully: returncode 0
2017-05-26 07:41:03: Runtime: 0 second(s)
2017-05-26 07:41:03: 66% complete - 76 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:03: Running check script 149 of 224: checkpagesize.ksh

Description:
------------

Determines the page sizes supported by AIX.

AIX is capable of using different page sizes. It has been introduced in AIX 5.3 TL4. Using larger 
virtual memory page sizes for an application’s memory can significantly improve an application's 
performance and throughput due to hardware efficiencies associated with larger page sizes.

The following example displays per-page size information for all of the page sizes with page frames on 
a system:

# vmstat -P all

The svmon command can also be used to display page size usage across the system:

# svmon -G

Output:
------------

4K 64K 16M 16G

2017-05-26 07:41:03: Check checkpagesize.ksh completed successfully: returncode 0
2017-05-26 07:41:03: Runtime: 0 second(s)
2017-05-26 07:41:03: 66% complete - 75 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:03: Running check script 150 of 224: checkpathorder.ksh

Description:
------------

Check the order of the path statements in the $PATH variable.

For security purposes, and for the correct working of many commands, it is important that folders 
within rootvg are mentioned in $PATH before any folders that are outside of rootvg, for example folders 
for application or database purposes. A hacker might place commands that are common to the operating 
system into a less secure folders outside the rootvg, and this way circumvent security. Hence, the 
order of statements in the $PATH variable is important.

2017-05-26 07:41:03: Check checkpathorder.ksh completed successfully: returncode 0
2017-05-26 07:41:03: Runtime: 0 second(s)
2017-05-26 07:41:03: 66% complete - 74 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:03: Running check script 151 of 224: checkpathstatements.ksh

Description:
------------

Display the $PATH statements in /etc/profile and /etc/environment.

The system variable $PATH is set in either /etc/profile and/or /etc/environment. Users can alter the 
PATH as they log in to the system. 

Setting the $PATH variable correctly is necessary to ensure that the correct binaries are found by the 
system, and hackers can not use it to have malicious software executed first. Therefore the order of 
the paths in the $PATH variable is important. Also ensure that no dots are present in $PATH, as this 
may allow an attacker to trick a user run a binary from a different directory.

Output:
------------

Current $PATH setting:

/usr/bin:/etc:/usr/sbin:/usr/ucb:/usr/bin/X11:/sbin:/usr/java6/jre/bin:/usr/java6/bin:/usr/es/sbin/clust
er:/usr/es/sbin/cluster/utilities

$PATH statements in /etc/environment:

PATH=/usr/bin:/etc:/usr/sbin:/usr/ucb:/usr/bin/X11:/sbin:/usr/java6/jre/bin:/usr/java6/bin:/usr/es/sbin/
cluster:/usr/es/sbin/cluster/utilities
LOCPATH=/usr/lib/nls/loc
NLSPATH=/usr/lib/nls/msg/%L/%N:/usr/lib/nls/msg/%L/%N.cat:/usr/lib/nls/msg/%l.%c/%N:/usr/lib/nls/msg/%l.
%c/%N.cat

2017-05-26 07:41:04: Check checkpathstatements.ksh completed successfully: returncode 0
2017-05-26 07:41:04: Runtime: 1 second(s)
2017-05-26 07:41:04: 67% complete - 73 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:04: Running check script 152 of 224: checkpgsplist.ksh

Description:
------------

Lists the paging spaces.

Output:
------------

Page Space      Physical Volume   Volume Group    Size %Used Active  Auto  Type Chksum
hd6             hdisk1            rootvg       32768MB     1   yes   yes    lv     0

2017-05-26 07:41:04: Check checkpgsplist.ksh completed successfully: returncode 0
2017-05-26 07:41:04: Runtime: 0 second(s)
2017-05-26 07:41:04: 67% complete - 72 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:04: Running check script 153 of 224: checkpgspsize.ksh

Description:
------------

Checks the size in MB of the paging space.

Output:
------------

32768 MB

2017-05-26 07:41:04: Check checkpgspsize.ksh completed successfully: returncode 0
2017-05-26 07:41:04: Runtime: 0 second(s)
2017-05-26 07:41:04: 68% complete - 71 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:04: Running check script 154 of 224: checkpgspswapspaces.ksh

Description:
------------

Lists the paging spaces by displaying /etc/swapspaces.

This file is modified by the chps, mkps and rmps commands and referenced by the lsps and swapon 
commands.

Output:
------------

hd6:
	dev = /dev/hd6
	auto = yes
	checksum_size = 0

2017-05-26 07:41:04: Check checkpgspswapspaces.ksh completed successfully: returncode 0
2017-05-26 07:41:04: Runtime: 0 second(s)
2017-05-26 07:41:04: 68% complete - 70 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:04: Running check script 155 of 224: checkpiolsvp.ksh

Description:
------------

Displays the configured printers and their printer types.

2017-05-26 07:41:04: Check checkpiolsvp.ksh completed successfully: returncode 0
2017-05-26 07:41:04: Runtime: 0 second(s)
2017-05-26 07:41:04: 69% complete - 69 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:04: Running check script 156 of 224: checkpowerhacllscf.ksh

Description:
------------

Check script to run the PowerHA/HACMP command cllscf, to display the cluster configuration information.

Output:
------------

Cluster Name:	 tsm0000_cluster
Cluster Type:	 Standard
Heartbeat Type:	 Unicast
Repository Disk: hdisk26 (00fab085c266b25a)

There were 1 networks defined : net_ether_01
There are 2 nodes in this cluster.

NODE tsm0001:
	This node has 1 service IP label(s):

	Service IP Label tsm0000:
		IP address:	192.18.42.45
		Hardware Address: 	
		Network:	net_ether_01
		Attribute:	public
		Aliased Address?:	Enable

	Service IP Label tsm0000 has 1 communication interfaces.
		(Alternate Service) Communication Interface 1: tsm0001
		IP address:	192.18.42.43
		Network:	net_ether_01
		Attribute:	public
			Alias address for heartbeat:	
	Service IP Label tsm0000 has no communication interfaces for recovery.


NODE tsm0002:
	This node has 1 service IP label(s):

	Service IP Label tsm0000:
		IP address:	192.18.42.45
		Hardware Address: 	
		Network:	net_ether_01
		Attribute:	public
		Aliased Address?:	Enable

	Service IP Label tsm0000 has 1 communication interfaces.
		(Alternate Service) Communication Interface 1: tsm0002
		IP address:	192.18.42.44
		Network:	net_ether_01
		Attribute:	public
			Alias address for heartbeat:	
	Service IP Label tsm0000 has no communication interfaces for recovery.




Breakdown of network connections:

Connections to network net_ether_01
	Node tsm0001 is connected to network net_ether_01 by these interfaces: 
		tsm0001
		tsm0000

	Node tsm0002 is connected to network net_ether_01 by these interfaces: 
		tsm0002
		tsm0000


2017-05-26 07:41:04: Check checkpowerhacllscf.ksh completed successfully: returncode 0
2017-05-26 07:41:04: Runtime: 0 second(s)
2017-05-26 07:41:04: 69% complete - 68 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:05: Running check script 157 of 224: checkpowerhacllsif.ksh

Description:
------------

Check script to display the network information of a PowerHA/HACMP cluster, using the cllsif command.

Output:
------------

Adapter              Type       Network    Net Type   Attribute  Node       IP Address       Hardware 
Address Interface Name   Global Name      Netmask          Alias for HB Prefix Length

tsm0001             boot       net_ether_01 ether      public     tsm0001   192.18.42.43              
        en8                         255.255.255.0               24
tsm0000             service    net_ether_01 ether      public     tsm0001   192.18.42.45              
                                    255.255.255.0               24
tsm0002             boot       net_ether_01 ether      public     tsm0002   192.18.42.44              
        en8                         255.255.255.0               24
tsm0000             service    net_ether_01 ether      public     tsm0002   192.18.42.45              
                                    255.255.255.0               24

2017-05-26 07:41:05: Check checkpowerhacllsif.ksh completed successfully: returncode 0
2017-05-26 07:41:05: Runtime: 0 second(s)
2017-05-26 07:41:05: 70% complete - 67 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:05: Running check script 158 of 224: checkpowerhaclrginfo.ksh

Description:
------------

Display the output of the PowerHA/HACMP command clRGinfo, to show the resource group status in the 
cluster.

This check script only applies to AIX systems that have PowerHA or HACMP software installed.

Output:
------------

-----------------------------------------------------------------------------
Group Name                   State            Node                                                      
       
-----------------------------------------------------------------------------
tsm00_rg                    ONLINE           tsm0001                                                  
       
                             OFFLINE          tsm0002                                                  
       


2017-05-26 07:41:05: Check checkpowerhaclrginfo.ksh completed successfully: returncode 0
2017-05-26 07:41:05: Runtime: 0 second(s)
2017-05-26 07:41:05: 70% complete - 66 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:05: Running check script 159 of 224: checkpowerhaclstato.ksh

Description:
------------

Display the PowerHA/HACMP cluster status, using the clstat -o command.

Output:
------------



		clstat - PowerHA SystemMirror Cluster Status Monitor
		-------------------------------------

Cluster: tsm0000_cluster	(1472663071)
Fri May 26 07:41:05 PDT 2017
		State: UP		Nodes: 2
		SubState: STABLE

	Node: tsm0001		State: UP
	   Interface: tsm0001 (0)    		Address: 192.18.42.43
						State:   UP
	   Interface: tsm0000 (0)    		Address: 192.18.42.45
						State:   UP
	   Resource Group: tsm00_rg			State:	On line

	Node: tsm0002		State: UP
	   Interface: tsm0002 (0)    		Address: 192.18.42.44
						State:   UP


2017-05-26 07:41:05: Check checkpowerhaclstato.ksh completed successfully: returncode 0
2017-05-26 07:41:05: Runtime: 0 second(s)
2017-05-26 07:41:05: 70% complete - 65 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:05: Running check script 160 of 224: checkpowerhaclustertopology.ksh

Description:
------------

Display the PowerHA/HACMP cluster topology.

Output:
------------

Command: cltopinfo

Cluster Name:	 tsm0000_cluster
Cluster Type:	 Standard
Heartbeat Type:	 Unicast
Repository Disk: hdisk26 (00fab085c266b25a)

There are 2 node(s) and 1 network(s) defined

NODE tsm0001:
	Network net_ether_01
		tsm0000	192.18.42.45
		tsm0001	192.18.42.43

NODE tsm0002:
	Network net_ether_01
		tsm0000	192.18.42.45
		tsm0002	192.18.42.44

Resource Group tsm00_rg
	Startup Policy	 Online On Home Node Only
	Fallover Policy	 Fallover To Next Priority Node In The List
	Fallback Policy	 Never Fallback
	Participating Nodes	 tsm0001 tsm0002
	Service IP Label		 tsm0000

Command: cltopinfo -w (shows configured networks in the cluster)


Network net_ether_01
	NODE tsm0001:
		tsm0000	192.18.42.45
		tsm0001	192.18.42.43
	NODE tsm0002:
		tsm0000	192.18.42.45
		tsm0002	192.18.42.44

Command: cltopinfo -i (shows configured interfaces in the cluster)

IP Label                         Network          Type     Node             Address                     
             If      Netmask          Prefix Length 
=========                        =======          ====     ====             =======                     
             ====    =======          ============= 
tsm0000                         net_ether_01     ether    tsm0001         192.18.42.45                
                     255.255.255.0    24
tsm0001                         net_ether_01     ether    tsm0001         192.18.42.43                
             en8     255.255.255.0    24
tsm0000                         net_ether_01     ether    tsm0002         192.18.42.45                
                     255.255.255.0    24
tsm0002                         net_ether_01     ether    tsm0002         192.18.42.44                
             en8     255.255.255.0    24

2017-05-26 07:41:05: Check checkpowerhaclustertopology.ksh completed successfully: returncode 0
2017-05-26 07:41:05: Runtime: 0 second(s)
2017-05-26 07:41:05: 71% complete - 64 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:05: Running check script 161 of 224: checkpowerhatopsvcs.ksh

Description:
------------

Run the lssrc -ls topsvcs command to display the cluster heartbeats.

Output:
------------

0513-036 The request could not be passed to the topsvcs subsystem.
Start the subsystem and try your command again.

2017-05-26 07:41:06: Check checkpowerhatopsvcs.ksh completed successfully: returncode 0
2017-05-26 07:41:06: Runtime: 1 second(s)
2017-05-26 07:41:06: 71% complete - 63 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:06: Running check script 162 of 224: checkprinters.ksh

Description:
------------

Shows a list of printers.

2017-05-26 07:41:06: Check checkprinters.ksh completed successfully: returncode 0
2017-05-26 07:41:06: Runtime: 0 second(s)
2017-05-26 07:41:06: 72% complete - 62 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:06: Running check script 163 of 224: checkprocesslist.ksh

Description:
------------

Lists all running processes.

Output:
------------

     UID      PID     PPID   C    STIME    TTY  TIME CMD
    root        1        0   0   May 15      -  0:02 /etc/init
    root   720902        1   0   May 15      -  0:00 /usr/ccs/bin/shlap64
    root  4784222  5767856   0   May 15      -  1:58 /usr/es/sbin/cluster/clstrmgr
  daemon  4980884  5767856   0   May 15      -  0:00 /usr/sbin/rpc.statd -d 0 -t 50
tsmadmin  5111984  9502820   0   May 15      -  0:00 db2vend (PD Vendor Process - 258)
    root  5177436  5767856   0   May 15      -  0:29 /usr/sbin/rsct/bin/IBM.StorageRMd
    root  5439688  5767856   0   May 15      -  0:01 /var/perf/pm/bin/pmperfrec
    root  5505224  5767856   0   May 15      -  0:00 /usr/sbin/inetd
    root  5767394  5767856   0   May 15      -  0:00 /usr/sbin/sshd
    root  9240604  5767856   0   May 15      -  0:00 /usr/sbin/rsct/bin/IBM.DRMd
    root  9371676  5767856   0   May 15      -  0:28 /usr/sbin/rsct/bin/IBM.HostRMd
tsmadmin  9437298        1  10   May 15      - 12741:53 /opt/tivoli/tsm/server/bin/dsmserv -i 
/tsmhome/tsmadmin -q
    root  9502820        1   0   May 15      -  0:00 db2wdog 0 [tsmadmin]
    root  9568270  9175790   0   May 15      -  0:00 /usr/sbin/gsclvmd -r 30 -i 300 -t 300 -c 
00fab08500004c0000000158c36163ad -v 0
    root  9699506  9175790   0   May 15      -  0:01 /usr/sbin/gsclvmd -r 30 -i 300 -t 300 -c 
00fab08500004c0000000158c361f7c0 -v 0
    root  9961644  9175790   0   May 15      -  0:00 /usr/sbin/gsclvmd -r 30 -i 300 -t 300 -c 
00fab08500004c0000000158c36189e8 -v 0
    root 10027214  9175790   0   May 15      -  0:01 /usr/sbin/gsclvmd -r 30 -i 300 -t 300 -c 
00fab08500004c0000000158c361ac58 -v 0
tsmadmin 10092746  9502820   0   May 15      -  1:29 db2acd
    root 10354892  9502820   0   May 15      -  0:00 db2ckpwd 0
    root 10485964  9502820   0   May 15      -  0:00 db2ckpwd 0
    root 17957060  5767856   0   May 24      -  0:00 /usr/sbin/tftpd -n
    root  3801598        1   0   May 15      - 13:32 /usr/sbin/syncd 60
    root  3998014  5767856   0   May 15      -  0:01 /usr/sbin/aixmibd
    root  4260220  5767856   0   May 15      -  0:37 /usr/es/sbin/cluster/clinfo
    root  4391386  5767856   0   May 15      -  0:09 /usr/sbin/aso
    root  4456860  5767856   0   May 15      -  0:15 /usr/sbin/rsct/bin/IBM.ConfigRMd
    root  5046756  5767856   0   May 15      -  0:04 /usr/sbin/snmpd
    root  6357292  5767856   0   May 15      -  0:13 /usr/sbin/clconfd
    root  6422796  5767856   0   May 15      -  0:00 /usr/sbin/rsct/bin/IBM.ServiceRMd
    root  6488380  5767856   0   May 15      -  1:34 /usr/sbin/rsct/bin/IBM.MgmtDomainRMd
    root  6553884  3802014   0   May 15      -  0:00 [trspoolm]
    root  6685010  9175790   0   May 15      -  0:00 /usr/sbin/gsclvmd -r 30 -i 300 -t 300 -c 
00fab08500004c0000000158c361d0a2 -v 0
tsmadmin  6750498  9502820   0   May 15      -  1:27 db2fmp
    root  7668166  9175790   0   May 15      -  0:00 /usr/sbin/gsclvmd -r 30 -i 300 -t 300 -c 
00fab08500004c0000000159b5045e38 -v 0
    root  7733650  5767856   0   May 15      -  0:01 /usr/es/sbin/cluster/clevmgrd
    root  7930236  9502820   0   May 15      -  0:00 db2ckpwd 0
    root  7995868        1   0   May 15      - 65:01 /opt/tivoli/tsm/ui/utils/../jre/bin/java 
-javaagent:/opt/tivoli/tsm/ui/Liberty/bin/tools/ws-javaagent.jar -Djava.awt.headless=true 
-Dcom.ibm.jsse2.sp800-131=transition -Xms512m -Xmx2048m -DKC_HOME=kcci_usr -jar 
/opt/tivoli/tsm/ui/Liberty/bin/tools/ws-server.jar guiServer
    root  8061252  5767856   0   May 24      -  0:00 /usr/sbin/rpc.mountd
    root 12517638        1   0 00:00:02      -  0:02 /usr/bin/topas_nmon  -fTNAdKLMOPVY^ -w 4 -s 300 -c 
288 -m /var/adm/nmon -youtput_dir=/var/adm/nmon/tsm0001 -ystart_time=00:00:01,May26,2017
    root  4063826  5767856   0   May 15      -  0:00 /usr/sbin/snmpmibd
    root  4522558  5767856   0   May 15      -  0:00 /usr/sbin/pfcdaemon
    root  4784744        1   0   May 15      -  1:45 /usr/bin/topasrec  -L -s 300 -R 1 -r 6 -o 
/var/perf/daily/ -ypersistent=1 -O type=bin -ystart_time=12:00:39,May15,2017
    root  4850310  5767856   1   May 15      -  1:49 /usr/sbin/clcomd -d
    root  5177990        1   0   May 15      -  0:04 /usr/sbin/cron
    root  5505670  5767856   0   May 15      -  0:03 /usr/sbin/syslogd -R
    root  5767856        1   0   May 15      -  0:00 /usr/sbin/srcmstr
    root  5898934  5767856   0   May 15      -  0:00 /usr/sbin/biod 6
    root  6030056  5767856   0   May 15      -  0:07 sendmail: accepting connections
    root  6095612  5767856   0   May 15      -  0:00 /usr/sbin/hrd
    root  9175790  5767856   0   May 15      -  0:00 /usr/sbin/gsclvmd
tsmadmin  9306848  9502820 115   May 15      - 12127:14 db2sysc 0
    root  9831110  9175790   0   May 15      -  0:01 /usr/sbin/gsclvmd -r 30 -i 300 -t 300 -c 
00fab08500004c0000000158c3624528 -v 0
tsmadmin 10289878  9502820   0   May 15      -  0:18 db2fmp
    root 12714646        1   0   May 17      -  2:00 /usr/sbin/getty /dev/console
    root 15008260 19465054   0 06:29:03  pts/0  0:00 -ksh
    root 15794690  5767856   0   May 24      -  0:00 /usr/sbin/nfsd 3891
    root 16450292 18743408   1 07:41:06  pts/0  0:00 ps -ef
    root 20513436  5767394   0 06:28:54      -  0:00 sshd: root [priv]
    root  3802014  5767856   0   May 15      -  2:04 /opt/rsct/bin/rmcd -a IBM.LPCommands -r -S 1500
    root  4260728  9175790   0   May 15      -  0:01 /usr/sbin/gsclvmd -r 30 -i 300 -t 300 -c 
00fab08500004c0000000158c36221fd -v 0
    root  4326188        1   0   May 15      -  2:03 /opt/tivoli/tsm/db2/bin/db2fmcd
    root  4457438 15008260   0 06:29:11  pts/0  0:00 -ksh
    root  4653902  5767856   0   May 15      -  0:00 /usr/sbin/portmap
  nobody  4784996 17957060   0   May 24      -  0:00 /usr/sbin/tftpd -n
    root  4850538        1   0   May 15      -  0:00 /usr/lib/errdemon
    root  4981656  5767856   0   May 15      -  0:34 /usr/sbin/xntpd -x
    root  5047084  4784222   0   May 15      -  0:00 run_rcovcmd
    root  5374900  5767856   0   May 15      -  0:00 /usr/sbin/rpc.lockd -d 0
    root  8913714  5767856   0   May 15      -  1:01 /opt/rsct/bin/hagsd cthags
    root 17761040  4457438  13 07:39:41  pts/0  0:02 /usr/bin/ksh ./checkall.ksh -C inventory -v -d
    root 18547598  5767856   0   May 24      -  0:00 /usr/sbin/nimesis -s
    root 19465054 20513436   0 06:29:03      -  0:00 sshd: root@pts/0

2017-05-26 07:41:06: Check checkprocesslist.ksh completed successfully: returncode 0
2017-05-26 07:41:06: Runtime: 0 second(s)
2017-05-26 07:41:06: 72% complete - 61 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:06: Running check script 164 of 224: checkprocessnumber.ksh

Description:
------------

Check the number of processes active.

Output:
------------

1108

2017-05-26 07:41:06: Check checkprocessnumber.ksh completed successfully: returncode 0
2017-05-26 07:41:06: Runtime: 0 second(s)
2017-05-26 07:41:06: 73% complete - 60 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:06: Running check script 165 of 224: checkprtconf.ksh

Description:
------------

Displays the output of the prtconf command.

Output:
------------

System Model: IBM,8286-42A
Machine Serial Number: 21C096X
Processor Type: PowerPC_POWER8
Processor Implementation Mode: POWER 8
Processor Version: PV_8_Compat
Number Of Processors: 24
Processor Clock Speed: 3525 MHz
CPU Type: 64-bit
Kernel Type: 64-bit
LPAR Info: 1 TSM0001
Memory Size: 255744 MB
Good Memory Size: 255744 MB
Platform Firmware level: SV860_082
Firmware Version: IBM,FW860.20 (SV860_082)
Console Login: enable
Auto Restart: true
Full Core: false
NX Crypto Acceleration: Capable and Enabled
 
Network Information
	Host Name: tsm0001
	IP Address: 192.18.42.43
	Sub Netmask: 255.255.255.0
	Gateway: 192.18.42.1
	Name Server: 
	Domain Name: 
 
Paging Space Information
	Total Paging Space: 32768MB
	Percent Used: 1%
 
Volume Groups Information
============================================================================== 
Active VGs
============================================================================== 
tsmrecoveryvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk42           active            1599        1           00..00..00..00..01
hdisk9            active            119         1           00..00..00..00..01
============================================================================== 
 
tsmhomevg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk47           active            1597        1           00..00..00..00..01
============================================================================== 
 
tsmfs02vg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk24           active            1023        1           00..00..00..00..01
hdisk27           active            1023        1           00..00..00..00..01
hdisk30           active            1023        1           00..00..00..00..01
hdisk33           active            1023        1           00..00..00..00..01
hdisk34           active            1023        1           00..00..00..00..01
hdisk36           active            1023        1           00..00..00..00..01
hdisk37           active            1023        1           00..00..00..00..01
hdisk39           active            1023        1           00..00..00..00..01
hdisk40           active            1023        1           00..00..00..00..01
hdisk43           active            1023        1           00..00..00..00..01
hdisk45           active            1023        1           00..00..00..00..01
============================================================================== 
 
tsmfs01vg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk2            active            1023        1           00..00..00..00..01
hdisk4            active            1023        1           00..00..00..00..01
hdisk7            active            1023        1           00..00..00..00..01
hdisk10           active            1023        1           00..00..00..00..01
hdisk13           active            1023        1           00..00..00..00..01
hdisk14           active            1023        1           00..00..00..00..01
hdisk16           active            1023        1           00..00..00..00..01
hdisk17           active            1023        1           00..00..00..00..01
hdisk19           active            1023        1           00..00..00..00..01
hdisk20           active            1023        1           00..00..00..00..01
hdisk22           active            1023        1           00..00..00..00..01
============================================================================== 
 
tsmdbvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk3            active            1999        999         400..00..00..199..400
hdisk5            active            1999        999         400..00..00..199..400
hdisk15           active            1999        999         400..00..00..199..400
hdisk18           active            1999        999         400..00..00..199..400
hdisk21           active            1999        999         400..00..00..199..400
hdisk23           active            1999        999         400..00..00..199..400
hdisk25           active            1999        999         400..00..00..199..400
hdisk35           active            1999        999         400..00..00..199..400
hdisk38           active            1999        999         400..00..00..199..400
hdisk41           active            1999        999         400..00..00..199..400
hdisk44           active            1999        999         400..00..00..199..400
hdisk46           active            1999        999         400..00..00..199..400
============================================================================== 
 
tsmdbbkpvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk8            active            1791        1           00..00..00..00..01
hdisk11           active            1791        1           00..00..00..00..01
hdisk28           active            1791        1           00..00..00..00..01
hdisk31           active            1791        1           00..00..00..00..01
============================================================================== 
 
tsmarchlogvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk12           active            1023        1           00..00..00..00..01
hdisk32           active            1023        1           00..00..00..00..01
============================================================================== 
 
tsmactlogvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk29           active            1199        1           00..00..00..00..01
============================================================================== 
 
caavg_private:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk26           active            79          72          16..09..15..16..16
============================================================================== 
 
rootvg:
PV_NAME           PV STATE          TOTAL PPs   FREE PPs    FREE DISTRIBUTION
hdisk0            active            558         331         61..03..44..111..112
hdisk1            active            558         331         95..00..13..111..112
============================================================================== 
 
INSTALLED RESOURCE LIST

The following resources are installed on the machine.
+/- = Added or deleted from Resource List.
*   = Diagnostic support not available.
	
  Model Architecture: chrp
  Model Implementation: Multiple Processor, PCI bus
	
+ sys0                                                                           System Object
+ sysplanar0                                                                     System Planar
* vio0                                                                           Virtual I/O Bus
* vsa0             U8286.42A.21C096X-V1-C0                                       LPAR Virtual Serial 
Adapter
* vty0             U8286.42A.21C096X-V1-C0-L0                                    Asynchronous Terminal
* pci13            U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ fcs2             U78C9.001.WZS0TLH-P1-C3-T1                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)
* fscsi2           U78C9.001.WZS0TLH-P1-C3-T1                                    FC SCSI I/O Controller 
Protocol Device
* pdisk180         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk181         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk182         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk183         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk184         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk185         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk186         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk187         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk188         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk189         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk190         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk191         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk192         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk193         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk194         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk195         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk196         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk197         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk198         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk199         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk200         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk201         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk202         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk203         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk204         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk205         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk206         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk207         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk208         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk209         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk210         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk211         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk212         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk213         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk214         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk215         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk216         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk217         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk218         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk219         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk220         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk221         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk222         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk223         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk224         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk225         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk226         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk227         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk228         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk229         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk230         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk231         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk232         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk233         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk234         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk235         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk236         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk237         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk238         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk239         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk240         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk241         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk242         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk243         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk244         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk245         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk246         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk247         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk248         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk249         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk250         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk251         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk252         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk253         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk254         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk255         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk256         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk257         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk258         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk259         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk260         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk261         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk262         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk263         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk264         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk265         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk266         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk267         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk268         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk269         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk364         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk365         U78C9.001.WZS0TLH-P1-C3-T1                                    DELL Compellent 
Storage subsystem disk
* sfwcomm2         U78C9.001.WZS0TLH-P1-C3-T1-W0-L0                              Fibre Channel Storage 
Framework Comm
+ fcs3             U78C9.001.WZS0TLH-P1-C3-T2                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)
* fscsi3           U78C9.001.WZS0TLH-P1-C3-T2                                    FC SCSI I/O Controller 
Protocol Device
* pdisk270         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk271         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk272         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk273         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk274         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk275         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk276         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk277         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk278         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk279         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk280         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk281         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk282         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk283         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk284         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk285         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk286         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk287         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk288         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk289         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk290         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk291         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk292         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk293         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk294         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk295         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk296         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk297         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk298         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk299         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk300         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk301         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk302         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk303         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk304         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk305         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk306         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk307         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk308         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk309         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk310         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk311         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk312         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk313         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk314         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk315         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk316         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk317         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk318         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk319         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk320         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk321         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk322         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk323         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk324         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk325         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk326         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk327         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk328         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk329         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk330         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk331         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk332         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk333         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk334         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk335         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk336         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk337         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk338         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk339         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk340         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk341         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk342         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk343         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk344         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk345         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk346         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk347         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk348         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk349         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk350         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk351         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk352         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk353         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk354         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk355         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk356         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk357         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk358         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk359         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk366         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk367         U78C9.001.WZS0TLH-P1-C3-T2                                    DELL Compellent 
Storage subsystem disk
* sfwcomm3         U78C9.001.WZS0TLH-P1-C3-T2-W0-L0                              Fibre Channel Storage 
Framework Comm
* pci12            U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci11            U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci10            U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci9             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ sissas1          U78C9.001.WZS0TLH-P1-C15-T1                                   PCIe3 x8 SAS RAID 
Internal Adapter 6Gb
* sas1             U78C9.001.WZS0TLH-P1-C15-T1                                   Controller SAS 
Protocol
* sfwcomm5                                                                       SAS Storage Framework 
Comm
+ hdisk1           U78C9.001.WZS0TLH-P2-D1                                       SAS 4K Disk Drive 
(600000 MB)
+ ses1             U78C9.001.WZS0TLH-P2-Y1                                       SAS Enclosure Services 
Device
* sata1            U78C9.001.WZS0TLH-P1-C15-T1                                   Controller SATA 
Protocol
* pci8             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ ent4             U78C9.001.WZS0TLH-P1-C10-T1                                   PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)
+ ent5             U78C9.001.WZS0TLH-P1-C10-T2                                   PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)
+ ent6             U78C9.001.WZS0TLH-P1-C10-T3                                   PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)
+ ent7             U78C9.001.WZS0TLH-P1-C10-T4                                   PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)
* pci7             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci6             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci5             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ usbhc0           U78C9.001.WZS0TLH-P1                                          Integrated USB 3.0 
xHCI Adapter (4c1041821410b204)
* pci4             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ ent0             U78C9.001.WZS0TLH-P1-C6-T1                                    PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)
+ ent1             U78C9.001.WZS0TLH-P1-C6-T2                                    PCIe2 4-Port Adapter 
(10GbE SFP+) (e4148a1614109304)
+ ent2             U78C9.001.WZS0TLH-P1-C6-T3                                    PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)
+ ent3             U78C9.001.WZS0TLH-P1-C6-T4                                    PCIe2 4-Port Adapter 
(1GbE RJ45) (e4148a1614109404)
* pci3             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ sissas0          U78C9.001.WZS0TLH-P1-C14-T1                                   PCIe3 x8 SAS RAID 
Internal Adapter 6Gb
* sas0             U78C9.001.WZS0TLH-P1-C14-T1                                   Controller SAS 
Protocol
* sfwcomm4                                                                       SAS Storage Framework 
Comm
+ hdisk0           U78C9.001.WZS0TLH-P2-D7                                       SAS 4K Disk Drive 
(600000 MB)
+ ses0             U78C9.001.WZS0TLH-P2-Y1                                       SAS Enclosure Services 
Device
* sata0            U78C9.001.WZS0TLH-P1-C14-T1                                   Controller SATA 
Protocol
+ cd0              U78C9.001.WZS0TLH-P2-D27                                      SATA DVD-RAM Drive
* pci2             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci1             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
* pci0             U78C9.001.WZS0TLH-P1                                          PCI Express Bus
+ fcs0             U78C9.001.WZS0TLH-P1-C7-T1                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)
* fscsi0           U78C9.001.WZS0TLH-P1-C7-T1                                    FC SCSI I/O Controller 
Protocol Device
* pdisk0           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk2           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L20000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk1           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk3           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L10000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk2           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk4           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L22000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk3           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk5           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L12000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk4           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk6           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk5           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk7           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L24000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk6           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk8           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L14000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk7           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk9           U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L4000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk8           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk10          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L26000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk9           U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk11          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L16000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk10          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk12          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L6000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk11          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk13          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L28000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk12          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk14          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L18000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk13          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk15          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L8000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk14          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk16          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2A000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk15          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk17          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1A000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk16          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk18          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LA000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk17          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk19          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L2C000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk18          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk20          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1C000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk19          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk21          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LC000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk20          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk22          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-L1E000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk21          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk23          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000F7E245-LE000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk22          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk23          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk24          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk25          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk26          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk27          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk28          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk29          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk30          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk31          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk32          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk33          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk34          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk35          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk36          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk37          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk38          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk39          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk40          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk41          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk42          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk43          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk44          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk24          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L21000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk45          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk25          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L11000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk46          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk26          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk47          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk27          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L23000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk48          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk28          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L13000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk49          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk29          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L3000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk50          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk30          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L25000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk51          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk31          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L15000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk52          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk32          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L5000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk53          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk33          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L27000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk54          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk34          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L17000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk55          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk35          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L7000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk56          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk36          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L29000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk57          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk37          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L19000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk58          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk38          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L9000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk59          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk39          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2B000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk60          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk40          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1B000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk61          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk41          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LB000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk62          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk42          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2D000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk63          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk43          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1D000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk64          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk44          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LD000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk65          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk45          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L1F000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk66          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk46          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-LF000000000000   MPIO Compellent Fibre 
Channel Disk Drive
* pdisk67          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk68          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk69          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk70          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk71          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk72          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk73          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk74          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk75          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk76          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk77          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk78          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk79          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk80          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk81          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk82          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk83          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk84          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk85          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk86          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk87          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk88          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk89          U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* pdisk360         U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* hdisk47          U78C9.001.WZS0TLH-P1-C7-T1-W5000D31000E8F42D-L2E000000000000  MPIO Compellent Fibre 
Channel Disk Drive
* pdisk361         U78C9.001.WZS0TLH-P1-C7-T1                                    DELL Compellent 
Storage subsystem disk
* sfwcomm0         U78C9.001.WZS0TLH-P1-C7-T1-W0-L0                              Fibre Channel Storage 
Framework Comm
+ fcs1             U78C9.001.WZS0TLH-P1-C7-T2                                    PCIe2 2-Port 16Gb FC 
Adapter (df1000e21410f103)
* fscsi1           U78C9.001.WZS0TLH-P1-C7-T2                                    FC SCSI I/O Controller 
Protocol Device
* pdisk90          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk91          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk92          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk93          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk94          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk95          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk96          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk97          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk98          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk99          U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk100         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk101         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk102         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk103         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk104         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk105         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk106         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk107         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk108         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk109         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk110         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk111         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk112         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk113         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk114         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk115         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk116         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk117         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk118         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk119         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk120         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk121         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk122         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk123         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk124         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk125         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk126         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk127         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk128         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk129         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk130         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk131         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk132         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk133         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk134         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk135         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk136         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk137         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk138         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk139         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk140         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk141         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk142         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk143         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk144         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk145         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk146         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk147         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk148         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk149         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk150         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk151         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk152         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk153         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk154         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk155         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk156         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk157         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk158         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk159         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk160         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk161         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk162         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk163         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk164         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk165         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk166         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk167         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk168         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk169         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk170         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk171         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk172         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk173         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk174         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk175         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk176         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk177         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk178         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk179         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk362         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* pdisk363         U78C9.001.WZS0TLH-P1-C7-T2                                    DELL Compellent 
Storage subsystem disk
* sfwcomm1         U78C9.001.WZS0TLH-P1-C7-T2-W0-L0                              Fibre Channel Storage 
Framework Comm
+ L2cache0                                                                       L2 Cache
+ mem0                                                                           Memory
+ proc0                                                                          Processor
+ proc8                                                                          Processor
+ proc104                                                                        Processor
+ proc112                                                                        Processor
+ proc120                                                                        Processor
+ proc128                                                                        Processor
+ proc136                                                                        Processor
+ proc144                                                                        Processor
+ proc152                                                                        Processor
+ proc16                                                                         Processor
+ proc160                                                                        Processor
+ proc168                                                                        Processor
+ proc176                                                                        Processor
+ proc184                                                                        Processor
+ proc24                                                                         Processor
+ proc32                                                                         Processor
+ proc40                                                                         Processor
+ proc48                                                                         Processor
+ proc56                                                                         Processor
+ proc64                                                                         Processor
+ proc72                                                                         Processor
+ proc80                                                                         Processor
+ proc88                                                                         Processor
+ proc96                                                                         Processor

2017-05-26 07:41:11: Check checkprtconf.ksh completed successfully: returncode 0
2017-05-26 07:41:11: Runtime: 5 second(s)
2017-05-26 07:41:11: 73% complete - 59 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:11: Running check script 166 of 224: checkrawlvperms.ksh

Description:
------------

Lists the permissions of raw logical volumes.

Output:
------------

crw-rw----    1 root     system       44,  1 May 15 12:01 /dev/rcaalv_private1
crw-rw----    1 root     system       44,  2 Dec 06 13:23 /dev/rcaalv_private2
crw-rw----    1 root     system       44,  3 Dec 06 13:23 /dev/rcaalv_private3
crw-rw----    1 root     system       44,  4 Dec 06 13:23 /dev/rpowerha_crlv
crw-rw----    2 root     system       10,  1 Nov 29 18:52 /dev/rhd5
crw-rw----    1 root     system       10,  2 May 12 12:25 /dev/rhd6
crw-rw----    1 root     system       10,  3 Nov 29 18:52 /dev/rhd8
crw-rw----    1 root     system       10, 13 Mar 22 13:17 /dev/rdumplv0
crw-rw----    1 root     system       10, 14 Mar 22 13:17 /dev/rdumplv1

2017-05-26 07:41:12: Check checkrawlvperms.ksh completed successfully: returncode 0
2017-05-26 07:41:12: Runtime: 1 second(s)
2017-05-26 07:41:12: 74% complete - 58 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:12: Running check script 167 of 224: checkrcd.ksh

Description:
------------

Displays the contents of /etc/rc.d folder. This folder contains scripts that are run during system 
start up.

Output:
------------

-r-xr--r--    1 root     system         1610 Jun 27 2010  /etc/rc.d/rc
drwxr-xr-x    2 root     system         4096 May 11 12:04 /etc/rc.d/rc2.d
-r-xr--r--    1 root     system         1194 Dec 05 10:40 /etc/rc.d/rc2.d/Kcluster
-r-xr-xr-x    1 root     system         1502 Aug 24 2016  /etc/rc.d/rc2.d/KrsctPHA
-r-xr-xr-x    1 root     system          325 May 11 12:04 /etc/rc.d/rc2.d/Ksshd
-r-x------    1 root     system         2545 Nov 29 19:02 /etc/rc.d/rc2.d/Kwpars
-rwxr-xr-x    1 root     system          165 Nov 29 19:25 /etc/rc.d/rc2.d/S00ct_boot
lrwxrwxrwx    1 root     system           21 May 11 08:17 /etc/rc.d/rc2.d/S90sudo -> 
/etc/rc.d/init.d/sudo
-r-xr--r--    1 root     system         1477 Dec 05 10:40 /etc/rc.d/rc2.d/Scluster
-r-xr-xr-x    1 root     system          616 Aug 24 2016  /etc/rc.d/rc2.d/SrsctPHA
-r-xr-xr-x    1 root     system          326 May 11 12:04 /etc/rc.d/rc2.d/Ssshd
drwxr-xr-x    2 root     system          256 Oct 10 2016  /etc/rc.d/rc3.d
drwxr-xr-x    2 root     system          256 Oct 10 2016  /etc/rc.d/rc4.d
drwxr-xr-x    2 root     system          256 Oct 10 2016  /etc/rc.d/rc5.d
drwxr-xr-x    2 root     system          256 Oct 10 2016  /etc/rc.d/rc6.d
drwxr-xr-x    2 root     system          256 Oct 10 2016  /etc/rc.d/rc7.d
drwxr-xr-x    2 root     system          256 Oct 10 2016  /etc/rc.d/rc8.d
drwxr-xr-x    2 root     system          256 Oct 10 2016  /etc/rc.d/rc9.d

2017-05-26 07:41:12: Check checkrcd.ksh completed successfully: returncode 0
2017-05-26 07:41:12: Runtime: 0 second(s)
2017-05-26 07:41:12: 74% complete - 57 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:12: Running check script 168 of 224: checkrpcinfo.ksh

Description:
------------

Shows the output of rpcinfo.

Output:
------------

   program vers proto   port  service
    100000    4   udp    111  portmapper
    100000    3   udp    111  portmapper
    100000    2   udp    111  portmapper
    100000    4   tcp    111  portmapper
    100000    3   tcp    111  portmapper
    100000    2   tcp    111  portmapper
    100021    1   udp  32774  nlockmgr
    100021    2   udp  32774  nlockmgr
    100021    3   udp  32774  nlockmgr
    100021    4   udp  32774  nlockmgr
    100021    1   tcp  32770  nlockmgr
    100021    2   tcp  32770  nlockmgr
    100021    3   tcp  32770  nlockmgr
    100021    4   tcp  32770  nlockmgr
    100024    1   tcp  32776  status
    100024    1   udp  32797  status
    100133    1   tcp  32776
    100133    1   udp  32797
    200001    1   tcp  32776
    200001    1   udp  32797
    200001    2   tcp  32776
    200001    2   udp  32797
    100003    2   udp   2049  nfs
    100003    3   udp   2049  nfs
    100003    2   tcp   2049  nfs
    100003    3   tcp   2049  nfs
    100003    4   tcp   2049  nfs
    200006    1   udp   2049
    200006    4   udp   2049
    200006    1   tcp   2049
    200006    4   tcp   2049
    100005    1   tcp  52194  mountd
    100005    2   tcp  52194  mountd
    100005    3   tcp  52194  mountd
    100005    1   udp  64819  mountd
    100005    2   udp  64819  mountd
    100005    3   udp  64819  mountd
    400005    1   udp  64820

2017-05-26 07:41:13: Check checkrpcinfo.ksh completed successfully: returncode 0
2017-05-26 07:41:13: Runtime: 0 second(s)
2017-05-26 07:41:13: 75% complete - 56 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:13: Running check script 169 of 224: checkrperf.ksh

Description:
------------

Displays the rPerf value. This script is created by Nigel Griffiths from IBM and was downloaded from 
http://www.ibm.com/developerworks/wikis/display/WikiPtype/rperf.

For verbose output, run: 

# ./checkrperf.ksh -v

For more information about the use of this script, please refer to the URL provided above.

Output:
------------

421.90 rPerf  based on 24.00 Virtual CPU cores

2017-05-26 07:41:13: Check checkrperf.ksh completed successfully: returncode 0
2017-05-26 07:41:13: Runtime: 0 second(s)
2017-05-26 07:41:13: 75% complete - 55 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:13: Running check script 170 of 224: checkrpm.ksh

Description:
------------

Lists all installed RPM packages.

Output:
------------

AIX-rpm-7.1.4.30-1
tcl-8.4.7-3
tk-8.4.7-3
expect-5.42.1-3
wget-1.17.1-1
pci.1014034a.51-15511800-1
db-4.8.24-3
openldap-2.4.40-1
sudo-1.8.15-2
unzip-6.0-3
pci.1014034a.51-16519400-1
pci.1014034a.51-16519400-1
curl-7.52.1-1
ca-certificates-2016.10.7-1

2017-05-26 07:41:13: Check checkrpm.ksh completed successfully: returncode 0
2017-05-26 07:41:13: Runtime: 0 second(s)
2017-05-26 07:41:13: 75% complete - 54 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:13: Running check script 171 of 224: checksambasmbconf.ksh

Description:
------------

Shows the smb.conf file of Samba, if Samba is installed.

The configuration file for Samba is usually located in /etc/smb.conf or /usr/lib/smb.conf.

2017-05-26 07:41:14: Check checksambasmbconf.ksh completed successfully: returncode 0
2017-05-26 07:41:14: Runtime: 1 second(s)
2017-05-26 07:41:14: 76% complete - 53 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:14: Running check script 172 of 224: checksambastatus.ksh

Description:
------------

Shows the status of Samba, if Samba is installed.

You can run this yourself:

# /usr/bin/smbstatus

2017-05-26 07:41:14: Check checksambastatus.ksh completed successfully: returncode 0
2017-05-26 07:41:14: Runtime: 0 second(s)
2017-05-26 07:41:14: 76% complete - 52 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:14: Running check script 173 of 224: checksar.ksh

Description:
------------

Reports the system unit activity by running sar. 

This script will only show output, if the proper system activity entries in the crontab of user adm are 
uncommented.

2017-05-26 07:41:14: Check checksar.ksh completed successfully: returncode 0
2017-05-26 07:41:14: Runtime: 0 second(s)
2017-05-26 07:41:14: 77% complete - 51 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:14: Running check script 174 of 224: checksarb.ksh

Description:
------------

Reports the system buffer activity by running sar -b.

This script will only show output, if the proper system activity entries in the crontab of user adm are 
uncommented.

2017-05-26 07:41:14: Check checksarb.ksh completed successfully: returncode 0
2017-05-26 07:41:14: Runtime: 0 second(s)
2017-05-26 07:41:14: 77% complete - 50 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:14: Running check script 175 of 224: checksdddatapath.ksh

Description:
------------

Runs the datapath commands to show SVC / IBM storage.

2017-05-26 07:41:14: Check checksdddatapath.ksh completed successfully: returncode 0
2017-05-26 07:41:14: Runtime: 0 second(s)
2017-05-26 07:41:14: 78% complete - 49 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:14: Running check script 176 of 224: checksddpcmpath.ksh

Description:
------------

Runs the pcmpath command to show SVC / IBM storage.

2017-05-26 07:41:14: Check checksddpcmpath.ksh completed successfully: returncode 0
2017-05-26 07:41:14: Runtime: 0 second(s)
2017-05-26 07:41:14: 78% complete - 48 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:14: Running check script 177 of 224: checksendmailaliasesfile.ksh

Description:
------------

Check if the aliases file, as referred to in /etc/mail/sendmail.cf, exists.

The aliases file is an important file for the Sendmail mail system. If it does not exist, mail probably 
can't be delivered. Also, make sure that a symbolic link from /etc/aliases to the aliases file exists, 
for example:

# ln -s /etc/mail/aliases /etc/aliases

After making modifications to the aliases file for Sendmail, ensure to run the newaliases command to 
recreate the aliases database:

# newaliases

2017-05-26 07:41:14: Check checksendmailaliasesfile.ksh completed successfully: returncode 0
2017-05-26 07:41:14: Runtime: 0 second(s)
2017-05-26 07:41:14: 79% complete - 47 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:14: Running check script 178 of 224: checksendmailversion.ksh

Description:
------------

Check the sendmail version. This script will merely display the version of sendmail in use.

Output:
------------

Version AIX7.1/8.14.4

2017-05-26 07:41:15: Check checksendmailversion.ksh completed successfully: returncode 0
2017-05-26 07:41:15: Runtime: 1 second(s)
2017-05-26 07:41:15: 79% complete - 46 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:15: Running check script 179 of 224: checkserialno.ksh

Description:
------------

Check the serial number on an AIX system.

Output:
------------

21C096X

2017-05-26 07:41:15: Check checkserialno.ksh completed successfully: returncode 0
2017-05-26 07:41:15: Runtime: 0 second(s)
2017-05-26 07:41:15: 79% complete - 45 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:15: Running check script 180 of 224: checkserials.ksh

Description:
------------

Check the serial numbers of all machine cabinets.

Output:
------------

Machine/Cabinet Serial No...21D096X
Machine/Cabinet Serial No...WXQ05XZ

2017-05-26 07:41:15: Check checkserials.ksh completed successfully: returncode 0
2017-05-26 07:41:15: Runtime: 0 second(s)
2017-05-26 07:41:15: 80% complete - 44 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:15: Running check script 181 of 224: checkshowmount.ksh

Description:
------------

Run showmount to display a list of all clients that have remotely mounted file systems, by running:

# showmount -a

2017-05-26 07:41:16: Check checkshowmount.ksh completed successfully: returncode 0
2017-05-26 07:41:16: Runtime: 1 second(s)
2017-05-26 07:41:16: 80% complete - 43 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:16: Running check script 182 of 224: checksimpanalevel.ksh

Description:
------------

Shows the level of the CommVault Simpana client.

2017-05-26 07:41:16: Check checksimpanalevel.ksh completed successfully: returncode 0
2017-05-26 07:41:16: Runtime: 0 second(s)
2017-05-26 07:41:16: 81% complete - 42 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:16: Running check script 183 of 224: checksimpanastatus.ksh

Description:
------------

Shows the status of the CommVault Simpana client, if installed.

2017-05-26 07:41:16: Check checksimpanastatus.ksh completed successfully: returncode 0
2017-05-26 07:41:16: Runtime: 0 second(s)
2017-05-26 07:41:16: 81% complete - 41 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:16: Running check script 184 of 224: checksisraidmgr.ksh

Description:
------------

Checks the settings for any RAID arrays using the sisraidmgr command. For a full syntax for this 
command, run:

# sisraidmgr -h

2017-05-26 07:41:16: Check checksisraidmgr.ksh completed successfully: returncode 0
2017-05-26 07:41:16: Runtime: 0 second(s)
2017-05-26 07:41:16: 82% complete - 40 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:16: Running check script 185 of 224: checksissasraidmgr.ksh

Description:
------------

Checks the settings for any RAID arrays.

2017-05-26 07:41:16: Check checksissasraidmgr.ksh completed successfully: returncode 0
2017-05-26 07:41:16: Runtime: 0 second(s)
2017-05-26 07:41:16: 82% complete - 39 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:16: Running check script 186 of 224: checkssadevices.ksh

Description:
------------

This check script will check for any existing SSA devices in the system and display them if found.

2017-05-26 07:41:18: Check checkssadevices.ksh completed successfully: returncode 0
2017-05-26 07:41:18: Runtime: 2 second(s)
2017-05-26 07:41:18: 83% complete - 38 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:18: Running check script 187 of 224: checkssaraid.ksh

Description:
------------

Check the status of any SSA RAID arrays.

2017-05-26 07:41:18: Check checkssaraid.ksh completed successfully: returncode 0
2017-05-26 07:41:18: Runtime: 0 second(s)
2017-05-26 07:41:18: 83% complete - 37 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:18: Running check script 188 of 224: checkssaraidarrays.ksh

Description:
------------

Check the status of any SSA RAID arrays and its disks.

2017-05-26 07:41:18: Check checkssaraidarrays.ksh completed successfully: returncode 0
2017-05-26 07:41:18: Runtime: 0 second(s)
2017-05-26 07:41:18: 83% complete - 36 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:18: Running check script 189 of 224: checksudoers.ksh

Description:
------------

Does a cat of the /etc/sudoers file.

Output:
------------

## sudoers file.
##
## This file MUST be edited with the 'visudo' command as root.
## Failure to use 'visudo' may result in syntax or file permission errors
## that prevent sudo from running.
##
## See the sudoers man page for the details on how to write a sudoers file.
##

##
## Host alias specification
##
## Groups of machines. These may include host names (optionally with wildcards),
## IP addresses, network numbers or netgroups.
# Host_Alias	WEBSERVERS = www1, www2, www3

##
## User alias specification
##
## Groups of users.  These may consist of user names, uids, Unix groups,
## or netgroups.
# User_Alias	ADMINS = millert, dowdy, mikef

##
## Cmnd alias specification
##
## Groups of commands.  Often used to group related commands together.
# Cmnd_Alias	PROCESSES = /usr/bin/nice, /bin/kill, /usr/bin/renice, \
# 			    /usr/bin/pkill, /usr/bin/top
# Cmnd_Alias	REBOOT = /sbin/halt, /sbin/reboot, /sbin/poweroff

##
## Defaults specification
##
## You may wish to keep some of the following environment variables
## when running commands via sudo.
##
## Locale settings
# Defaults env_keep += "LANG LANGUAGE LINGUAS LC_* _XKB_CHARSET"
##
## Run X applications through sudo; HOME is used to find the
## .Xauthority file.  Note that other programs use HOME to find   
## configuration files and this may lead to privilege escalation!
# Defaults env_keep += "HOME"
##
## X11 resource path settings
# Defaults env_keep += "XAPPLRESDIR XFILESEARCHPATH XUSERFILESEARCHPATH"
##
## Desktop path settings
# Defaults env_keep += "QTDIR KDEDIR"
##
## Allow sudo-run commands to inherit the callers' ConsoleKit session
# Defaults env_keep += "XDG_SESSION_COOKIE"
##
## Uncomment to enable special input methods.  Care should be taken as
## this may allow users to subvert the command being run via sudo.
# Defaults env_keep += "XMODIFIERS GTK_IM_MODULE QT_IM_MODULE QT_IM_SWITCHER"
##
## Uncomment to use a hard-coded PATH instead of the user's to find commands
# Defaults secure_path="/usr/local/sbin:/usr/local/bin:/usr/sbin:/usr/bin:/sbin:
/bin"
##
## Uncomment to send mail if the user does not enter the correct password.
# Defaults mail_badpass
##
## Uncomment to enable logging of a command's output, except for
## sudoreplay and reboot.  Use sudoreplay to play back logged sessions.
# Defaults log_output
# Defaults!/usr/bin/sudoreplay !log_output
# Defaults!/usr/local/bin/sudoreplay !log_output
# Defaults!REBOOT !log_output
Defaults        logfile=/var/log/sudo.log, log_year, loglinelen=0

##
## Runas alias specification
##

##
## User privilege specification
##
root ALL=(ALL) ALL

## Uncomment to allow members of group wheel to execute any command
# %wheel ALL=(ALL) ALL

## Same thing without a password
# %wheel ALL=(ALL) NOPASSWD: ALL
%sysadm ALL=(ALL) NOPASSWD: ALL

## Uncomment to allow members of group sudo to execute any command
# %sudo	ALL=(ALL) ALL

## Uncomment to allow any user to run sudo if they know the password
## of the user they are running the command as (root by default).
# Defaults targetpw  # Ask for the password of the target user
# ALL ALL=(ALL) ALL  # WARNING: only use this together with 'Defaults targetpw'

## Read drop-in files from /etc/sudoers.d
## (the '#' here does not indicate a comment)
##includedir /etc/sudoers.d

2017-05-26 07:41:18: Check checksudoers.ksh completed successfully: returncode 0
2017-05-26 07:41:18: Runtime: 0 second(s)
2017-05-26 07:41:18: 84% complete - 35 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:18: Running check script 190 of 224: checksystemattr.ksh

Description:
------------

Shows the system attributes. To check this yourself, you can run:

# lsattr -El sys0

Output:
------------

SW_dist_intr    false                                Enable SW distribution of interrupts               
 True
autorestart     true                                 Automatically REBOOT OS after a crash              
 True
boottype        disk                                 N/A                                                
 False
capacity_inc    1.00                                 Processor capacity increment                       
 False
capped          true                                 Partition is capped                                
 False
chown_restrict  true                                 Chown Restriction Mode                             
 True
clouddev        0                                    Recreate ODM devices on next boot                  
 True
conslogin       enable                               System Console Login                               
 False
cpuguard        enable                               CPU Guard                                          
 True
dedicated       true                                 Partition is dedicated                             
 False
enhanced_RBAC   true                                 Enhanced RBAC Mode                                 
 True
ent_capacity    24.00                                Entitled processor capacity                        
 False
frequency       0                                    System Bus Frequency                               
 False
fullcore        false                                Enable full CORE dump                              
 True
fwversion       IBM,FW860.20 (SV860_082)             Firmware version and revision levels               
 False
ghostdev        0                                    Recreate ODM devices on system change / modify 
PVID True
id_to_partition 0X800011A145400001                   Partition ID                                       
 False
id_to_system    0X800011A145400000                   System ID                                          
 False
iostat          false                                Continuously maintain DISK I/O history             
 True
keylock         normal                               State of system keylock at boot time               
 False
log_pg_dealloc  false                                Log predictive memory page deallocation events     
 True
max_capacity    24.00                                Maximum potential processor capacity               
 False
max_logname     9                                    Maximum login name length at boot time             
 True
maxbuf          20                                   Maximum number of pages in block I/O BUFFER CACHE  
 True
maxmbuf         0                                    Maximum Kbytes of real memory allowed for MBUFS    
 True
maxpout         8193                                 HIGH water mark for pending write I/Os per file    
 True
maxuproc        2048                                 Maximum number of PROCESSES allowed per user       
 True
min_capacity    1.00                                 Minimum potential processor capacity               
 False
minpout         4096                                 LOW water mark for pending write I/Os per file     
 True
modelname       IBM,8286-42A                         Machine name                                       
 False
ncargs          256                                  ARG/ENV list size in 4K byte blocks                
 True
nfs4_acl_compat secure                               NFS4 ACL Compatibility Mode                        
 True
ngroups_allowed 128                                  Number of Groups Allowed                           
 True
os_uuid         15004cc5-c661-4e78-b6df-2649e45f8a6b N/A                                                
 True
pre430core      false                                Use pre-430 style CORE dump                        
 True
pre520tune      disable                              Pre-520 tuning compatibility mode                  
 True
realmem         261881856                            Amount of usable physical memory in Kbytes         
 False
rtasversion     1                                    Open Firmware RTAS version                         
 False
sed_config      select                               Stack Execution Disable (SED) Mode                 
 True
systemid        IBM,0221C096X                        Hardware system identifier                         
 False
variable_weight 0                                    Variable processor capacity weight                 
 False

2017-05-26 07:41:18: Check checksystemattr.ksh completed successfully: returncode 0
2017-05-26 07:41:18: Runtime: 0 second(s)
2017-05-26 07:41:18: 84% complete - 34 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:18: Running check script 191 of 224: checksystemboottime.ksh

Description:
------------

Check when the system was booted.

Output:
------------

system boot May 15 12:00                     

2017-05-26 07:41:18: Check checksystemboottime.ksh completed successfully: returncode 0
2017-05-26 07:41:18: Runtime: 0 second(s)
2017-05-26 07:41:18: 85% complete - 33 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:18: Running check script 192 of 224: checksysteminstall.ksh

Description:
------------

Check when the system was installed or upgraded.

Output:
------------

#Path:Fileset:Level:PTF Id:Action:Status:Date:Time
/etc/objrepos:bos.rte:7.1.4.30::COMMIT:COMPLETE:11/29/16:18;53;56
/usr/lib/objrepos:bos.rte:7.1.4.30::COMMIT:COMPLETE:11/29/16:18;53;56

2017-05-26 07:41:19: Check checksysteminstall.ksh completed successfully: returncode 0
2017-05-26 07:41:19: Runtime: 0 second(s)
2017-05-26 07:41:19: 85% complete - 32 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:19: Running check script 193 of 224: checktapedrives.ksh

Description:
------------

List the tape drives on the system.

2017-05-26 07:41:19: Check checktapedrives.ksh completed successfully: returncode 0
2017-05-26 07:41:19: Runtime: 0 second(s)
2017-05-26 07:41:19: 86% complete - 31 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:19: Running check script 194 of 224: checktcbinstalled.ksh

Description:
------------

Checks if the Trusted Computing Base is installed.

Output:
------------

The Trusted Computing Base is not enabled on this machine.

2017-05-26 07:41:19: Check checktcbinstalled.ksh completed successfully: returncode 0
2017-05-26 07:41:19: Runtime: 0 second(s)
2017-05-26 07:41:19: 86% complete - 30 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:19: Running check script 195 of 224: checkterminaltype.ksh

Description:
------------

Check the terminal type.

Output:
------------

vty0 vt220

2017-05-26 07:41:19: Check checkterminaltype.ksh completed successfully: returncode 0
2017-05-26 07:41:19: Runtime: 0 second(s)
2017-05-26 07:41:19: 87% complete - 29 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:19: Running check script 196 of 224: checktimezone.ksh

Description:
------------

Collect the time zone.

Output:
------------

America/Los_Angeles

2017-05-26 07:41:19: Check checktimezone.ksh completed successfully: returncode 0
2017-05-26 07:41:19: Runtime: 0 second(s)
2017-05-26 07:41:19: 87% complete - 28 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:19: Running check script 197 of 224: checktopmemoryusers.ksh

Description:
------------

Lists the top memory using users.

Output:
------------

Unit: auto                                                   Timestamp: 07:41:19
===============================================================================
User                                 Inuse      Pin     Pgsp  Virtual
tsmadmin                             99.5G  200.37M       0K    99.5G
root                                 2.17G  395.57M       0K    1.90G
daemon                               97.2M    73.6M       0K    97.1M
nobody                               94.6M    73.6M       0K    94.4M

2017-05-26 07:41:20: Check checktopmemoryusers.ksh completed successfully: returncode 0
2017-05-26 07:41:20: Runtime: 0 second(s)
2017-05-26 07:41:20: 87% complete - 27 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:20: Running check script 198 of 224: checktotalsan.ksh

Description:
------------

Check the total size of IBM and/or EMC SAN storage in use on the server in gigabytes.

Output:
------------

Dell EMC SC / Compellent: 400006 GB

2017-05-26 07:41:20: Check checktotalsan.ksh completed successfully: returncode 0
2017-05-26 07:41:20: Runtime: 0 second(s)
2017-05-26 07:41:20: 88% complete - 26 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:20: Running check script 199 of 224: checktsmconfig.ksh

Description:
------------

Displays the contents of the dsm.opt and dsm.sys files, if those are available on the system.

This check only applies to systems that are backed up by TSM / IBM Spectrum Protect.

Output:
------------

Contents of /usr/tivoli/tsm/client/ba/bin64/dsm.opt:

************************************************************************
* Tivoli Storage Manager                                               *
*                                                                      *
* Sample Client User Options file for AIX and SunOS (dsm.opt.smp)      *
************************************************************************

*  This file contains an option you can use to specify the TSM
*  server to contact if more than one is defined in your client
*  system options file (dsm.sys).  Copy dsm.opt.smp to dsm.opt.
*  If you enter a server name for the option below, remove the
*  leading asterisk (*).

************************************************************************

* SErvername       A server name defined in the dsm.sys file
SE	TSMWTC

Contents of /usr/tivoli/tsm/client/ba/bin64/dsm.sys:

************************************************************************
* Tivoli Storage Manager                                               *
*                                                                      *
* Sample Client System Options file for AIX and SunOS (dsm.sys.smp)    *
************************************************************************

*  This file contains the minimum options required to get started
*  using TSM.  Copy dsm.sys.smp to dsm.sys.  In the dsm.sys file,
*  enter the appropriate values for each option listed below and
*  remove the leading asterisk (*) for each one.

*  If your client node communicates with multiple TSM servers, be
*  sure to add a stanza, beginning with the SERVERNAME option, for
*  each additional server.

************************************************************************

SErvername                      TSMWTC
    COMMmethod                  TCPip
    TCPServeraddress            192.18.42.45
    TCPPort                     1500
    NODename                    TSM0001
    TCPWINDOWSIZE               64
    TXNBYTELIMIT                25600
    PASSWORDACCESS              generate
    CHANGINGRETRIES             1
    INCLEXCL                    /usr/tivoli/tsm/client/ba/bin64/inclexcl.opt
    SCHEDLOGNAME                /var/log/backup/dsmsched.log
    ERRORLOGNAME                /var/log/backup/dsmerror.log
    SCHEDLOGRET                 1 S
    ERRORLOGRET                 1 S
    SCHEDMODE                   polling
    COMPRESSION                 no
    PASSWORDACCESS              generate
    RESOURCEUtilization         6


2017-05-26 07:41:20: Check checktsmconfig.ksh completed successfully: returncode 0
2017-05-26 07:41:20: Runtime: 0 second(s)
2017-05-26 07:41:20: 88% complete - 25 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:20: Running check script 200 of 224: checktsmfilesystems.ksh

Description:
------------

Displays the last backup dates of file systems in TSM / IBM Spectrum Protect.

Make sure to review the output of this check script. It may list file systems that no longer exist on 
the server, but have once been backed up to TSM / IBM Spectrum Protect, and thus use up storage space. 
If necessary, make sure to delete any backups of old file spaces in TSM / IBM Spectrum Protect to free 
up storage space.

Output:
------------

Unable to retrieve TSM / IBM Spectrum Protect file systems.

2017-05-26 07:41:21: Check checktsmfilesystems.ksh reported ERROR(s): returncode 0
2017-05-26 07:41:21: Runtime: 0 second(s)
2017-05-26 07:41:21: 89% complete - 24 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:21: Running check script 201 of 224: checktsminclexcl.ksh

Description:
------------

Displays the included and excluded file systems and files for the TSM / IBM Spectrum Protect backup.

Be sure to review the output of this check script carefully, and ensure the correct file systems are 
included and/or excluded from the backup.

Backing up the correct file systems is vital for being able to recover (a part of) a system. Also, make 
sure that you're not backing up open files, such as database files, as this will not yield a valid 
backup. For such items as open database files, a valid database specific backup or export should be 
made to a separate location, which in turn then can be backed up to TSM / IBM Spectrum Protect.

Output:
------------

Unable to retrieve TSM / IBM Spectrum Protect include/exclude list.

2017-05-26 07:41:21: Check checktsminclexcl.ksh reported ERROR(s): returncode 0
2017-05-26 07:41:21: Runtime: 0 second(s)
2017-05-26 07:41:21: 89% complete - 23 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:21: Running check script 202 of 224: checktsmtdpoconf.ksh

Description:
------------

This will run tdpoconf showenv, to show the TSM TDP for Oracle / Spectrum Protect for Databases for 
Oracle configuration, if installed.

2017-05-26 07:41:21: Check checktsmtdpoconf.ksh completed successfully: returncode 0
2017-05-26 07:41:21: Runtime: 0 second(s)
2017-05-26 07:41:21: 90% complete - 22 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:21: Running check script 203 of 224: checktty.ksh

Description:
------------

Shows a list of TTYs.

Output:
------------

vty0 Available  Asynchronous Terminal

2017-05-26 07:41:21: Check checktty.ksh completed successfully: returncode 0
2017-05-26 07:41:21: Runtime: 0 second(s)
2017-05-26 07:41:21: 90% complete - 21 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:21: Running check script 204 of 224: checkunamea.ksh

Description:
------------

Display the system information by running the uname -a command.

This will display the operating system, the level, the release number, the hostname and the machine ID 
number.

Output:
------------

AIX tsm0001 1 7 00FAB0773D00

2017-05-26 07:41:21: Check checkunamea.ksh completed successfully: returncode 0
2017-05-26 07:41:21: Runtime: 0 second(s)
2017-05-26 07:41:21: 91% complete - 20 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:21: Running check script 205 of 224: checkusernumber.ksh

Description:
------------

Check the number of users logged in.

Output:
------------

1

2017-05-26 07:41:22: Check checkusernumber.ksh completed successfully: returncode 0
2017-05-26 07:41:22: Runtime: 1 second(s)
2017-05-26 07:41:22: 91% complete - 19 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:22: Running check script 206 of 224: checkusersloggedon.ksh

Description:
------------

Display the users that are currently logged on.

Output:
------------

Name        Line           Time              Hostname
root        pts/0       May 26 06:29     (172.22.0.250)  

2017-05-26 07:41:22: Check checkusersloggedon.ksh completed successfully: returncode 0
2017-05-26 07:41:22: Runtime: 0 second(s)
2017-05-26 07:41:22: 91% complete - 18 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:22: Running check script 207 of 224: checkvaclevel.ksh

Description:
------------

Checks the level of XL C/C++ (VisualAge C/C++) compiler.

For support documentation, please visit:

http://ibm.com/support/entry/portal/Documentation/Software/Rational/XL_C_for_AIX

2017-05-26 07:41:22: Check checkvaclevel.ksh completed successfully: returncode 0
2017-05-26 07:41:22: Runtime: 0 second(s)
2017-05-26 07:41:22: 92% complete - 17 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:22: Running check script 208 of 224: checkvcshastatus.ksh

Description:
------------

Check the status of Veritas Cluster Server, if installed.

2017-05-26 07:41:22: Check checkvcshastatus.ksh completed successfully: returncode 0
2017-05-26 07:41:22: Runtime: 0 second(s)
2017-05-26 07:41:22: 92% complete - 16 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:22: Running check script 209 of 224: checkvgsize.ksh

Description:
------------

Shows the volume groups that are online on the server and the size of each volume group in megabytes.

This information can be very useful, in case the server is lost, and needs to be rebuild, and a 
determination is required of how much disk space was assigned to each volume group.

Output:
------------

tsmrecoveryvg 439808 MB
tsmhomevg 51104 MB
tsmfs02vg 184369152 MB
tsmfs01vg 184369152 MB
tsmdbvg 6140928 MB
tsmdbbkpvg 29343744 MB
tsmarchlogvg 4190208 MB
tsmactlogvg 306944 MB
caavg_private 5056 MB
rootvg 1142784 MB

2017-05-26 07:41:24: Check checkvgsize.ksh completed successfully: returncode 0
2017-05-26 07:41:24: Runtime: 2 second(s)
2017-05-26 07:41:24: 93% complete - 15 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:25: Running check script 210 of 224: checkvgsummary.ksh

Description:
------------

Shows a summary of volume group space allocated, used and available in gigabytes.

Output:
------------

             VG     Total (GB)      Free (GB)      USED (GB)     Disks
  tsmrecoveryvg            429              0            429         2
      tsmhomevg             49              0             49         1
      tsmfs02vg         180048            176         179872        11
      tsmfs01vg         180048            176         179872        11
        tsmdbvg           5997           2997           3000        12
     tsmdbbkpvg          28656             16          28640         4
   tsmarchlogvg           4092              4           4088         2
    tsmactlogvg            299              0            299         1
  caavg_private              4              4              0         1
         rootvg           1116            662            454         2

2017-05-26 07:41:26: Check checkvgsummary.ksh completed successfully: returncode 0
2017-05-26 07:41:26: Runtime: 2 second(s)
2017-05-26 07:41:26: 93% complete - 14 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:26: Running check script 211 of 224: checkvmo.ksh

Description:
------------

Check the vmo settings. 

If an error message "Cannot access tunable parameters because /unix does not match the running kernel." 
can be seen, this means the server should be rebooted after doing a technology level and/or service 
pack upgrade, before this script can be run properly.

When changing a certain tunable, you may get an error message regarding a restricted tunable. If that 
happens, don't change the tunable, unless it is really necessary. If the tunable is restricted, but 
this script still alerts about it, you may need to look at /etc/tunables/nextboot. Most likely, the 
tunable is set in this file, and you may need to remove the tunable from this file.

2017-05-26 07:41:26: Check checkvmo.ksh completed successfully: returncode 0
2017-05-26 07:41:26: Runtime: 0 second(s)
2017-05-26 07:41:26: 94% complete - 13 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:26: Running check script 212 of 224: checkvmoa.ksh

Description:
------------

Lists the virtual memory (VM) options by running:

# vmo -a

Output:
------------

             ame_cpus_per_pool = n/a
               ame_maxfree_mem = n/a
           ame_min_ucpool_size = n/a
               ame_minfree_mem = n/a
               ams_loan_policy = n/a
  enhanced_affinity_affin_time = 1
enhanced_affinity_vmpool_limit = 10
                esid_allocator = 1
           force_relalias_lite = 0
             kernel_heap_psize = 65536
                  lgpg_regions = 0
                     lgpg_size = 0
               low_ps_handling = 1
                       maxfree = 1088
                       maxperm = 57157883
                        maxpin = 59117992
                       maxpin% = 90
                 memory_frames = 65470464
                 memplace_data = 0
          memplace_mapped_file = 0
        memplace_shm_anonymous = 0
            memplace_shm_named = 0
                memplace_stack = 0
                 memplace_text = 0
        memplace_unmapped_file = 0
                       minfree = 960
                       minperm = 1905255
                      minperm% = 3
                   msem_nlocks = 0
                     nokilluid = 0
                       npskill = 65536
                   npsscrubmax = 524288
                   npsscrubmin = 393216
                       npswarn = 262144
           num_locks_per_semid = 1
                     numpsblks = 8388608
                    pgz_lpgrow = 1
                      pgz_mode = 1
               pinnable_frames = 59966920
           relalias_percentage = 0
                         scrub = 0
                    scrubclean = 0
                 thrpgio_inval = 1024
                thrpgio_npages = 1024
                      v_pinshm = 0
                 vm_cpu_thresh = 0
                  vm_mmap_bmap = 1
              vmm_default_pspa = 0
                vmm_klock_mode = 2
            wlm_memlimit_nonpg = 1

2017-05-26 07:41:26: Check checkvmoa.ksh completed successfully: returncode 0
2017-05-26 07:41:26: Runtime: 0 second(s)
2017-05-26 07:41:26: 94% complete - 12 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:27: Running check script 213 of 224: checkvmstat.ksh

Description:
------------

Checks if vmstat is available on the server. If not installed, please install the lpp fileset 
containing vmstat, usually bos.acct.

If vmstat is available, this script will run it to display Virtual Memory Manager statistics since 
boot.

Output:
------------

Since system boot:

System configuration: lcpu=192 mem=255744MB

 kthr          memory                         page                       faults           cpu    
------- --------------------- ------------------------------------ ------------------ -----------
  r   b        avm        fre    re    pi    po    fr     sr    cy    in     sy    cs us sy id wa
  4   1   31763119   11658583     0     0     0     0      0     0 19231  69046 57165  5  4 88  3

Currently (measured over 10 seconds):

 kthr          memory                         page                       faults           cpu    
------- --------------------- ------------------------------------ ------------------ -----------
  r   b        avm        fre    re    pi    po    fr     sr    cy    in     sy    cs us sy id wa
  3   1   31765935   11655760     0     0     0     0      0     0  4562  46466 44723  5  2 93  1

2017-05-26 07:41:37: Check checkvmstat.ksh completed successfully: returncode 0
2017-05-26 07:41:37: Runtime: 10 second(s)
2017-05-26 07:41:37: 95% complete - 11 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:37: Running check script 214 of 224: checkvmstats.ksh

Description:
------------

This script runs vmstat -s if the vmstat command is available. This will show paging statistics since 
boot.

Output:
------------

            382613659 total address trans. faults
           1671100718 page ins
          19879000654 page outs
                    0 paging space page ins
                    0 paging space page outs
                    0 total reclaims
            131284975 zero filled pages faults
                30628 executable filled pages faults
                    0 pages examined by clock
                    0 revolutions of the clock hand
                    0 pages freed by the clock
              4129027 backtracks
                    0 free frame waits
                    0 extend XPT waits
              2055639 pending I/O waits
          21550055293 start I/Os
            447981620 iodones
          53489632835 cpu context switches
          17994235937 device interrupts
          25441492760 software interrupts
           3704714120 decrementer interrupts
              1947653 mpc-sent interrupts
              1947624 mpc-receive interrupts
            181081364 phantom interrupts
                    0 traps
          64606440014 syscalls

2017-05-26 07:41:37: Check checkvmstats.ksh completed successfully: returncode 0
2017-05-26 07:41:37: Runtime: 0 second(s)
2017-05-26 07:41:37: 95% complete - 10 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:37: Running check script 215 of 224: checkvmstatv.ksh

Description:
------------

This check will run the following command: 

# vmstat -v

This shows the various statistics maintained by the Virtual Memory Manager (VMM).

Output:
------------

             65470464 memory pages
             63504672 lruable pages
             11655878 free pages
                   24 memory pools
              5503561 pinned pages
                 90.0 maxpin percentage
                  3.0 minperm percentage
                 90.0 maxperm percentage
                 34.6 numperm percentage
             22012985 file pages
                  0.0 compressed percentage
                    0 compressed pages
                 34.6 numclient percentage
                 90.0 maxclient percentage
             22012985 client pages
                    0 remote pageouts scheduled
               939574 pending disk I/Os blocked with no pbuf
                    0 paging space I/Os blocked with no psbuf
                 2228 filesystem I/Os blocked with no fsbuf
                 2135 client filesystem I/Os blocked with no fsbuf
                57747 external pager filesystem I/Os blocked with no fsbuf
                 48.6 percentage of memory used for computational pages

2017-05-26 07:41:37: Check checkvmstatv.ksh completed successfully: returncode 0
2017-05-26 07:41:37: Runtime: 0 second(s)
2017-05-26 07:41:37: 95% complete - 9 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:37: Running check script 216 of 224: checkvnbexclude.ksh

Description:
------------

Check the exclude_list for Veritas NetBackup, if this server is being backed up by Veritas NetBackup. 
This file is located in /usr/openv/netbackup/exclude_list.

2017-05-26 07:41:37: Check checkvnbexclude.ksh completed successfully: returncode 0
2017-05-26 07:41:37: Runtime: 0 second(s)
2017-05-26 07:41:37: 96% complete - 8 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:37: Running check script 217 of 224: checkvnbversion.ksh

Description:
------------

Check the version of Veritas NetBackup, if installed.

2017-05-26 07:41:37: Check checkvnbversion.ksh completed successfully: returncode 0
2017-05-26 07:41:37: Runtime: 0 second(s)
2017-05-26 07:41:37: 96% complete - 7 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:37: Running check script 218 of 224: checkvscsivhostmapping.ksh

Description:
------------

Display the mapping of any vscsi adapters to vhost adapters on VIOS servers.

This script will display the mapping of any vscsi adapters to the vhost adapters on VIOS servers, if 
any vscsi adapters are present on the system.

2017-05-26 07:41:37: Check checkvscsivhostmapping.ksh completed successfully: returncode 0
2017-05-26 07:41:37: Runtime: 0 second(s)
2017-05-26 07:41:37: 97% complete - 6 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:37: Running check script 219 of 224: checkwebsphereversion.ksh

Description:
------------

Check the version of WebSphere Application Server, if installed.

2017-05-26 07:41:38: Check checkwebsphereversion.ksh completed successfully: returncode 0
2017-05-26 07:41:38: Runtime: 1 second(s)
2017-05-26 07:41:38: 97% complete - 5 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:38: Running check script 220 of 224: checkwpar.ksh

Description:
------------

Check if there are any WPARs, and display their definitions.

2017-05-26 07:41:38: Check checkwpar.ksh completed successfully: returncode 0
2017-05-26 07:41:38: Runtime: 0 second(s)
2017-05-26 07:41:38: 98% complete - 4 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:38: Running check script 221 of 224: checkxivdevlist.ksh

Description:
------------

Display the output of the xiv_devlist command.

This check script will provide the output of the xiv_devlist command. The xiv_devlist command is part 
of the IBM XIV Host Attachment Kit (HAK), and is required for using XIV storage on the system.

2017-05-26 07:41:38: Check checkxivdevlist.ksh completed successfully: returncode 0
2017-05-26 07:41:38: Runtime: 0 second(s)
2017-05-26 07:41:38: 98% complete - 3 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:38: Running check script 222 of 224: checkxivfcadminstoragesystem.ksh

Description:
------------

Display the details of the XIV storage systems that are currently attached via Fibre Channel through 
the XIV Host Attachment Kit.

This check script will run the xiv_fc_admin command. This command is part of the IBM XIV Host 
Attachment Kit (HAK), and can be used to provide details of the XIV storage systems of an LUNs 
connected to the system via Fibre Channel.

The command that will display this information is:

# /usr/bin/xiv_fc_admin -L

2017-05-26 07:41:38: Check checkxivfcadminstoragesystem.ksh completed successfully: returncode 0
2017-05-26 07:41:38: Runtime: 0 second(s)
2017-05-26 07:41:38: 99% complete - 2 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:38: Running check script 223 of 224: checkxivfcadminwwpn.ksh

Description:
------------

Display the world-wide port number (WWPN) of host bus adapters (HBAs) installed on this host and 
recognized by the XIV Host Attachment Kit.

The xiv_fc_admin command can be used to display the world-wide port number (WWPN) of the host bus 
adapters (HBAs) installed on the system, and used by the IBM XIV Host Attachment Kit (HAK).

The command used for this purpose is:

# /usr/bin/xiv_fc_admin -P

2017-05-26 07:41:38: Check checkxivfcadminwwpn.ksh completed successfully: returncode 0
2017-05-26 07:41:38: Runtime: 0 second(s)
2017-05-26 07:41:38: 99% complete - 1 checks to go.
--------------------------------------------------------------------------------------------------------
2017-05-26 07:41:38: Running check script 224 of 224: checkxivsyslist.ksh

Description:
------------

Display the output of the xiv_syslist command.

The xiv_syslist command is part of the IBM XIV Host Attachment Kit, and can be used to provide system 
information of the XIV storage used on the system:

# /usr/bin/xiv_syslist

2017-05-26 07:41:38: Check checkxivsyslist.ksh completed successfully: returncode 0
2017-05-26 07:41:38: Runtime: 0 second(s)
2017-05-26 07:41:38: 100% complete - 0 checks to go.
--------------------------------------------------------------------------------------------------------

########################################################################################################

2017-05-26 07:41:39: RESULTS

2017-05-26 07:41:39: Run time for all checks              : 118 seconds
2017-05-26 07:41:39: Total number of checks               : 224
2017-05-26 07:41:39: # Checks with result OK              : 224
2017-05-26 07:41:39: # Checks with result WARNING         : 0
2017-05-26 07:41:39: # Checks with result ERROR           : 0
2017-05-26 07:41:39: Score [Percentage OK/WARNING]        : 100 %

2017-05-26 07:41:39: For details see logfile              : /uhc/checkall_tsm0001.log

########################################################################################################

